• Title/Summary/Keyword: Total suspended particulate (TSP)

Search Result 67, Processing Time 0.026 seconds

Residence Times and Chemical Composition of Atmospheric Aerosols I. Concentration of Major Ions and Heavy Metals in Pusan (대기 에어로졸의 체류시간과 화학조성 I. 부산지역에서 주요이온과 중금속의 농도)

  • Yang, Han-Sub;Jeon, Eun-Ju;Kim, Young-Il;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 1999
  • Chemical composition of atmospheric aerosols was measured at 4 sites in Pusan. All the samples were collected with a high volume air sampler from January to October 1996, to analyze major ions and heavy metals. Dominant ions of aerosols were S $O_4$$^{2-}$ in anion and N $a^{+}$ in cation. Sulfate, nitrate and ammonium ions in aerosols showed high enrichment factor to soil and seawater composition. The concentrations of heavy metals in aerosols was lowest at the site PI near the coast. The lowest concentrations of major ions and heavy metals mainly appeared in August, probably due to scavenging by frequent rains. Especially, the concentrations of total suspended particulate matter(TSP) and heavy metals in aerosols showed good correlations in Pusan. Based on crustal Al, enrichment factors for some metals(Zn, Cu, Pb, Cd) in aerosols were significantly greater than unity, and the order was Cd > Pb > Zn > Cu. This evidence suggests that Cd and Pb are derived predominantly from non-crustal sources.s.

  • PDF

Characteristics of Particle Size Distributions Generated in the Vicinity of Building Blasting Demolition Sites (발파해체현장에서 발생하는 순간분진의 입경분포 특성)

  • Lee, Kyoung-Hee;Kim, Hyo-Jin;Park, Chan-Gyu;Ko, Kwang-Baik
    • Journal of Environmental Science International
    • /
    • v.18 no.1
    • /
    • pp.41-47
    • /
    • 2009
  • In building demolition work, major dust-generating activities are blasting concrete and rock. The aim of this study was to find the characteristic of particle size of dusts which were generated during building demolition work using explosion. The DustMate of the Turnkey-Instruments Ltd. was used for particulate size-selective sampling of the four sites. TSP(Total Suspended Particle), PM10(Particle Matter $10{\mu}m$), PM2.5(Particle Matter $2.5{\mu}m$), and PM1.0(Particle Matter $1.0{\mu}m$) were measured during building demolition work using explosion. The large particulate (higher than the diameter $10{\mu}m$) showed to be higher than 50%. The particulate ranged from $10{\mu}m\;to\;2.5{\mu}m$ showed about 30-40%. PM2.5 was not scarcely detected in the samples collected for building demolition work using explosion. We conclude that the dust generated during building demolition work using explosion has not most respirable particulate.

Heavy Metals in Ambient Air at Shinchon Area in Seoul (도시 대기중 중금속에 관한 연구 -서울시 신촌지역을 중심으로-)

  • Chung, Yong;Jang, Jae-Yeon;Chu, Ui-Jo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.3 no.2
    • /
    • pp.18-26
    • /
    • 1987
  • In order to investigate the character of air pollution by heavy metals and to elucidate the possible sources in Seoul city, this study was performed to measure the concentrations of heavy metals of total suspended particulate and air pollutants such as $SO_2, NO_2, CO, CH_4$, Non-methane hydrocarbon, ozone at the residential-traffic area (shinchon dong) in January and February, 1986. The results are as follows: 1. $SO_2$ and TSP concentration were 135ppb and 167 $\mug/m^3$ in average, respectively. 2. While concentrations of heavy metals such as Fe, Cu, Pb in the ambient air seems gradually decreasing annually, Ni compound has been shown the tendency of increasing. 3. Among heavy metals in TSP analysed, the iron was detected at the highest level, 0.905% and the cadimium was the lowest 0.004% in average, respectively. 4. V, Fe and Zn compounds in air were observed to be highly correlated with their correlation coefficients(r) higher than 0.7. Pb compound was highly correlated to the levels of Zn and Fe, however relatively less correlated to V compound. 5. Among concentrations of heavy metals in the particulates, V and Ni compounds were highly correlated with coefficient(r) of 0.8587; the cause might be imagined by the fact of releasing from combustion of fuel oil. Fe, Pb and Zn compounds were highly correlated $SO_2$ concentration. It might be explained that they were released by combustion of coal. 6. The level of $SO_2$ was highly correlated to most of heavy metals: especially correlation coefficient(r) to Pb compound was 0.9081. Pb compound was also highly correlated to NO, CO and TSP. TSP showed higher correlation to Pb and Cd compounds than to V and Ni compounds. It might be assumed that particulate was mainly produced by combusting coal from space heating and by exhausting gasoline and diesel oil from transportation rather than by burning fuel oil.

  • PDF

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation (대기경계층과 연안순환에 의한 부유입자의 재순환)

  • Choe, Hyo
    • Journal of Environmental Science International
    • /
    • v.13 no.8
    • /
    • pp.721-731
    • /
    • 2004
  • The dispersion of suspended particulates in the coastal complex terrain of mountain-inland basin (city)-sea, considering their recycling was investigated using three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). Convective boundary layer under synoptic scale westerly wind is developed with a thickness of about I km over the ground in the west of the mountain, while a thickness of thermal internal boundary layer (TIBL) is only confined to less than 200m along the eastern slope of the mountain, below an easterly sea breeze circulation. At the mid of the eastern slop of the mountain, westerly wind confronts easterly sea breeze, which goes to the height of 1700 m above sea level and is finally eastward return flow toward the sea. At this time, particulates floated from the ground surface of the city to the top of TIBL go along the eastern slope of the mountain in the passage of sea breeze, being away the TIBL and reach near the top of the mountain. Then those particulates disperse eastward below the height of sea-breeze circulation and widely spread out over the coastal sea. Total suspended particulate concentration near the ground surface of the city is very low. On the other hand, nighttime radiative cooling produces a shallow nocturnal surface inversion layer (NSIL) of 200 m thickness over the inland surface, but relatively thin thickness less than 100m is found near the mountain surface. As synoptic scale westerly wind should be intensified under the association of mountain wind along the eastern slope of mountain to inland plain and further combine with land-breeze from inland plain toward sea, resulting in strong wind as internal gravity waves with a hydraulic jump motion bounding up to about 1km upper level in the atmosphere in the west of the city and becoming a eastward return flow. Simultaneously, wind near the eastern coastal side of the city was moderate. Since the downward strong wind penetrated into the city, the particulate matters floated near the top of the mountain in the day also moved down along the eastern slope of the mountain, reaching the. downtown and merging in the ground surface inside the NSIL with a maximum ground level concentration of total suspended particulates (TSP) at 0300 LST. Some of them were bounded up from the ground surface to the 1km upper level and the others were forward to the coastal sea surface, showing their dispersions from the coastal NSIL toward the propagation area of internal gravity waves. On the next day at 0600 LST and 0900 LST, the dispersed particulates into the coastal sea could return to the coastal inland area under the influence of sea breeze and the recycled particulates combine with emitted ones from the ground surface, resulting in relatively high TSP concentration. Later, they float again up to the thermal internal boundary layer, following sea breeze circulation.

The influence on air quality of the surroundings by the facility of the district heating (집단 에너지 시설에 의한 주변 대기질 영향)

  • 연익준;주소영;이민희;손종렬;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.18-25
    • /
    • 2002
  • The comparison of the air quality with the evaluation of the environmental assessment before and after operations of the heat source and of the flue-gas desulfurization facilities were studied. First of all, several sites were selected for the representative sample points, and then they were examined air quality of the surroundings. The results were that TSP(total suspended particulate) analysis after an operation of the heat source facility was $74~81{\mu}g/m^3$, PM-10 was $31~94{\mu}g/m^3$, and $SO_2$concentration was 0.002~0.009ppm, respectively. As the result of examination to the concentrations of diffused pollutants, there was no relations between TSP concentration of sample points and the effect of air quality according to the heating source. When we compared the neighbored area of the heating source with the other area, the concentration of air pollutants after an operation of the facility of the heating source was similar to the heating source, the neighbored area, and the other area. So we concluded that there was no the effect of the air pollution by producted pollutants from the heating source.

Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel (고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석)

  • You, Han-Jo;Jung, Yeon-Hoon;Kim, Jin-guil;Shin, Hyung-Soon;Lim, Yoon-Jung;Lee, Sang-Soo;Son, Hae-Jun;Lim, Sam-Hwa;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.

Scavenging Properties of Atmospheric Carbon by Precipitation

  • Hwang, Kyung-Chul;Ma, Chang-Jin;Cho, Ki-Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.77-85
    • /
    • 2004
  • In order to investigate the scavenging property of airborne carbonaceous particles by precipitations, rainwater, snow sample, and total suspended particulate matter (TSP) were collected at a heavily industrialized urban site. Elemental carbon (EC) contents of both rainwater and snow water were deter-mined using elemental analysis system. EC concentrations in rain samples varied from 33.6 to 166.6 $\mu\textrm{g}$ L$^{-1}$ with an average 47.2 $\mu\textrm{g}$ L$^{-1}$ . On the other hand, those of snow samples in three times snow events were ranged from 122.4 to 293.3 $\mu\textrm{g}$ L$^{-1}$ . As might be expected, EC showed the significantly high scavenging rate at the initial rainfall. The average total carbon (TC) scavenging rate by washout mechanisms was 57.6% for five rainfall events. The scavenging rate of EC gradually increased in proportion to the increasing rainfall intensity and rainfall amount.

On the Origin of Visibility Degradation in Seoul (서울지역의 시정 장애 요인에 관한 연구)

  • 윤순창;이강웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.229-236
    • /
    • 1998
  • Visibility is a good indicator of comprehensive alto quality. The prevailing visibility in Seoul is no better than the past although the average concentration of SO2 and TSP (total suspended particulate) has decreased quite significantly in the past decade, owing to the government efforts to reduce the emission. Then, a question arises why visibility has not been improved. In order to answer this question we have investigated which components of air pollutants are most responsible for the visibility degradation in Seoul. Analysis on the visibility vs the aerosol sixte distribution measured by an optical particle counter shows that the particles of the size interval between 0.5mm and 2.5mm are most responsible for the visibility degradation. Among the criteria air Pollutants, NOB concentration is found to be moot responsible, rather than PM10. ton analysis of the particulate collected by a high volume sampler shows that the nitrate component increases more significantly than other ions when visibility becomes very poor. Therefore, we conclude that the major causes of visibility degradation in Seoul are the increase of NOB, nitrates and the particles of the size range between 0.5mm and 2.5mm.

  • PDF

Atmospheric concentration and mutagenicity of organic pollutants of suspended particulate in Seoul (서울시 대기중 유기오염물질의 농도와 돌연변이원성에 대한 연구)

  • Shin, Dong-Chun;Chung, Yong;Moon, Young-Hahn;Roh, Jae-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.1 s.29
    • /
    • pp.43-56
    • /
    • 1990
  • To evaluate the difference of concentration and mutagenicity of organic pollutants between residential and traffic area of Seoul, air samples were collected in Bulkwang (residential) and Shinchon (traffic) area. Samples were analyzed to measure the concentration of extractable organic matters (EOM) and their subfractions and mutagenicities were tested using Salmonella typhimurium TA 98. The concentrations of polycyclic aromatic hydrocarbons (PAHs) were also measured by gas-chromatography and compared between two areas. The results were as follows ; 1. While the concentration of total suspended particulate (TSP) in residential area was below the environmental standard in annual average, the concentration in traffic area was above the standard and was up to its maximum $256{\mu}g/m^3$ in November. The difference of TSP concentrations in both areas of each month was statistically significant (P<0.05). 2. The concentration of fine particle in traffic area was significantly higher compare to that in residential area and showed statistically significant monthly difference in both areas (P<0.05). The proportion of concentration of fine particle to TSP was 55-68%. 3. Mean concentrations of EOM in residential and traffic areas were $4.3{\mu}g/m^3\;and\;5.3{\mu}g/m^3$ respectively. The proportion of amount of EOM from fine particle to EOM from TSP was 70-88%. 4. While the percentage of polar neutral organic compounds (POCN) of fine particle in Bulkwang's sample was higher compare to Shinchon's sample, the percentage of aliphatic compounds of fine particle in Shinchon's sample was higher compare to Bulkwang's sample. The percentages of PAH fraction were as low as 6-10% in both areas. 5. The mutagenic activity of nit concentration of organic matters extracted from fine particle was higher compare to that of coarse particle and was increased when metabolically activated with S9. Mutagenicities with metabolic activation calculated by unit air volume were significantly different between residential and traffic area, $17\;revertants/m^3$\;and\;22\;revertants/m^3$ respectively. 6. The concentrations of benzo(a)pyrene in fine particle of traffic and residential areas were $3.10ng/m^3\;and\;2.02ng/m^3$ respectively. Sixteen PAHs were higher in samples of traffic area compare to residential area and also concentrations of PAHs in fine particle were higher compare to coarse particle.

  • PDF

Monitoring of Dust Concentration Generated during Peach Sorting Operations (복숭아 선별작업장의 미세먼지의 발생특성 모니터링)

  • Seo, Hyo-Jae;Seo, Il-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.237-245
    • /
    • 2022
  • Peach is a typical summer fruit which can be used for various food, processed food, and fragrance ingredients in Korea. Peach is also known as one of serious allergens which make difficulty for farm workers during peach sorting operations. After peach harvesting, it moves to the sorting operations for removing cover material, removing fuzz on peach surface, sorting by size, and packing. The air-samplers and optical particle counters were used to analyze the characteristics of fine dust generation by location and operation characteristics in the experimental peach farms. During removing peach fuzz, the dust concentrations were increased by 6.89 times on total suspended particulate (TSP), 2.13 times on PM-10 (particulate matter), and 1.30 times on PM-2.5 compared to non-working periods, respectively. During removing peach covering materials, the dust concentrations were increased by 3.14 times on TSP, 1.91 times on PM-10, and 1.43 times on PM-2.5 compared to non-working periods, respectively. This represents peach fuzz can be affected to farm workers during peach sorting operations.