• Title/Summary/Keyword: Total radiation

Search Result 2,228, Processing Time 0.035 seconds

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

Effect of the Storage Temperature, Duration and Gamma Irradiation on the Respiration Rate and Sugar Content of Minituber 'Superior'

  • Lim, Ji-Hyeok;HwangBo, Jun-Kwon;Baek, Myung-Hwa;Kim, Jin-Hong;Kim, Jae-Sung;Lee, Myung-Chul
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.1
    • /
    • pp.61-65
    • /
    • 2005
  • This study was to evaluate whether ionizing gamma radiation could be applied to break the dormancy of a potato minituber. The respiration rate of the minitubers was significantly affected by the storage temperature and a low dose gamma radiation. Ionizing radiation of 8 Gy enhanced the respiration rate of the potato tuber stored at $10^{\circ}C$ for 20 days. The potato tuber subjected to 4 and 8 Gy after 40 days storage at 10 and $20^{\circ}C$ exhibited higher respiration rates compared to the control (non-irradiated), but not at st. However, the ionizing radiation did not exhibit on significant effect on the respiration rate of the potato tuber stored for 60 days. It was observed that minitubers stored for 20 days had significant response to the storage temperature in terms of the total sugar content the higher the storage temperature, the lower the total sugar content. It was measured that the reducing sugar content was increased under the storage conditions both 5 and $10^{\circ}C$ for 40 days, but not to $20^{\circ}C$. The total sugar contents in the minituber stored for 60 days were similar to those stored for 40 days. The data was discussed on the relationships among the storage duration, temperature and ionizing radiation.

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

A Study on recognition for Medical radiation of health and non-health for radiation safety (방사선안전을 위한 보건/비보건계열의 의료방사선 인식도 분석)

  • Choi, Sung-Oog;Lee, Myung-Sun
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.2
    • /
    • pp.93-100
    • /
    • 2016
  • This study implemented the survey and analysis of the exposure to radiation by using the questionnaire targeting H Health College, located in Daejeon from September 1st, 2014 to October 15th. A total of 400 copies of the questionnaire was distributed and among them, 385 copies, excluding 15 omitted ones (total collection ratio: 96.3%), were used for the analysis. The analysis results are as follows. For the harmfulness of radiation for diagnosis, the average of the health-related was 3.15 and the average of the health-unrelated was 2.82, which the health-related students recognized the harmfulness of radiation for diagnosis higher (p<.001). The necessity of radiation for diagnosis was appeared higher from the health-related students as the average of the health-related was 3.07 and 2.52 for the average of the health-unrelated (p<.001). The recognition on the prevention of the exposure to radiation was higher from the health-related students as the average of the health-related was 3.13 and 1.84 for the average of the health-unrelated (p<.001). From this study, the necessity of using radiation from the medical field and the recognition on its harmfulness appeared to have a big difference between the health-related and health-unrelated. For such, the accurate understanding of the recognition on radiation and the education to improve recognition on radiation are considered to be required.

Microbiological and Sensory Characteristics of Gamma-irradiated Frozen Bibimbap (감마선 조사 냉동비빔밥의 미생물 및 관능적 품질특성)

  • Park, Jae-Nam;Song, Beom-Seok;Yoon, Young-Min;Choi, Soo-Jeong;Park, Jong-Heum;Kim, Jae-Kyung;Byun, Eui-Baek;Lee, Ju-Woon;Han, In-Jun;Sohn, Hee-Sook;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.93-99
    • /
    • 2013
  • This study was conducted to evaluate the effect of gamma irradiation on the microbiological and sensory characteristics of frozen Bibimbap. Frozen Bibimbap vegetables were contaminated by microbial levels of $2.70{\sim}6.67log\;CFU\;g^{-1}$ in total aerobic bacteria. Frozen Bibimbap was contaminated by microbial levels of $4.8log\;CFU\;g^{-1}$ in total aerobic bacteria, but microorganisms in gamma-irradiated samples at above 25 kGy were not found at detection limit less then $1log\;CFUg^{-1}$. Sensory characteristics of the gamma-irradiated Bibimbap were decreased depending upon the irradiation dose, and sensory scores of the samples irradiated with doses higher than 10 kGy were significantly decreased. Therefore, the application of combination of the various food processing technology should be considered for the sterilization of Bibimbap, without any deterioration of quality occurred by high dose irradiation.

Factors predicting radiation pneumonitis in locally advanced non-small cell lung cancer

  • Kim, Myung-Soo;Lee, Ji-Hae;Ha, Bo-Ram;Lee, Re-Na;Lee, Kyung-Ja;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.181-190
    • /
    • 2011
  • Purpose: Thoracic radiotherapy is a major treatment modality of stage III non-small cell lung cancer. The normal lung tissue is sensitive to radiation and radiation pneumonitis is the most important dose-limiting complication of thoracic radiation therapy. This study was performed to identify the clinical and dosimetric parameters related to the risk of radiation pneumonitis after definitive radiotherapy in stage III non-small cell cancer patients. Materials and Methods: The medical records were reviewed for 49 patients who completed definitive radiation therapy for locally advanced non-small cell lung cancer from August 2000 to February 2010. Radiation therapy was delivered with the daily dose of 1.8 Gy to 2.0 Gy and the total radiation dose ranged from 50.0 Gy to 70.2 Gy (median, 61.2 Gy). Elective nodal irradiation was delivered at a dose of 45.0 Gy to 50.0 Gy. Seven patients (14.3%) were treated with radiation therapy alone and forty two patients (85.7%) were treated with chemotherapy either sequentially or concurrently. Results: Twenty-five cases (51.0%) out of 49 cases experienced radiation pneumonitis. According to the radiation pneumonitis grade, 10 (20.4%) were grade 1, 9 (18.4%) were grade 2, 4 (8.2%) were grade 3, and 2 (4.1%) were grade 4. In the univariate analyses, no clinical factors including age, sex, performance status, smoking history, underlying lung disease, tumor location, total radiation dose and chemotherapy were associated with grade ${\geq}2$ radiation pneumonitis. In the subgroup analysis of the chemotherapy group, concurrent rather than sequential chemotherapy was significantly related to grade ${\geq}2$ radiation pneumonitis comparing sequential chemotherapy. In the univariate analysis with dosimetric factors, mean lung dose (MLD), $V_{20}$, $V_{30}$, $V_{40}$, MLDipsi, $V_{20}$ipsi, $V_{30}$ipsi, and $V_{40}$ipsi were associated with grade ${\geq}2$ radiation pneumonitis. In addition, multivariate analysis showed that MLD and V30 were independent predicting factors for grade ${\geq}2$ radiation pneumonitis. Conclusion: Concurrent chemotherapy, MLD and $V_{30}$ were statistically significant predictors of grade ${\geq}2$ radiation pneumonitis in patients with stage III non-small cell lung cancer undergoing definitive radiotherapy. The cutoff values for MLD and $V_{30}$ were 16 Gy and 18%, respectively.

Effects of total body irradiation-based conditioning on allogeneic stem cell transplantation for pediatric acute leukemia: a single-institution study

  • Park, Jongmoo;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Young Seok;Kim, Su Ssan;Park, Jin-Hong;Park, Jaehyeon;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.32 no.3
    • /
    • pp.198-207
    • /
    • 2014
  • Purpose: To evaluate the effects of total body irradiation (TBI), as a conditioning regimen prior to allogeneic stem cell transplantation (allo-SCT), in pediatric acute leukemia patients. Materials and Methods: From January 2001 to December 2011, 28 patients, aged less than 18 years, were treated with TBI-based conditioning for allo-SCT in our institution. Of the 28 patients, 21 patients were diagnosed with acute lymphoblastic leukemia (ALL, 75%) and 7 were diagnosed with acute myeloid leukemia (AML, 25%). TBI was completed 4 days or 1 day before stem cell infusion. Patients underwent radiation therapy with bilateral parallel opposing fields and 6-MV X-rays. The Kaplan-Meier method was used to calculate survival outcomes. Results: The 2-year event-free survival and overall survival rates were 66% and 56%, respectively (71.4% and 60.0% in AML patients vs. 64.3% and 52.4% in ALL patients, respectively). Treatment related mortality rate were 25%. Acute and chronic graft-versus-host disease was a major complication; other complications included endocrine dysfunction and pulmonary complications. Common complications from TBI were nausea (89%) and cataracts (7.1%). Conclusion: The efficacy and toxicity data in this study of TBI-based conditioning to pediatric acute leukemia patients were comparable with previous studies. However, clinicians need to focus on the acute and chronic complications related to allo-SCT.

Possible Risk Factors Associated with Radiation Proctitis or Radiation Cystitis in Patients with Cervical Carcinoma after Radiotherapy

  • Yang, Lin;Lv, Yin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6251-6255
    • /
    • 2012
  • Radiation proctitis and radiation cystitis are major complications for patients with cervical carcinoma following radiotherapy. In the present study, we aimed to determine the potential risk factors for the development of radiation proctitis and radiation cystitis after irradiation. A total of 1,518 patients with cervical carcinoma received external beam radiotherapy (EBRT) followed by high-dose-rate intracavitary brachytherapy (HDRICB) in our hospital. The incidences of radiation proctitis and radiation cystitis were recorded and associations with different factors (age, time period, tumor stage) were analyzed with ${\chi}^2$ (chi-squared) and Fisher exact tests. We found that 161 and 94 patients with cervical carcinoma were diagnosed with radiation proctitis and radiation cystitis, respectively, following radiotherapy. The prevalence of Grade I-II radiation proctitis or radiation cystitis was significantly lower than that of Grade III (radiation proctitis: 3.82% vs. 6.76%, P < 0.05; radiation cystitis: 2.31% vs. 3.87%, P < 0.05) and was significantly enhanced in patients with late stage (IIIb) tumor progression compared to those in early stage (Ib, IIa) (P < 0.05). Moreover, the incidence of radiation proctitis and cystitis was not correlated with age or, time period following radiation, for each patient (P > 0.05). These observations indicate that a late stage of tumor progression is a potential risk factor for the incidence of radiation proctitis and cystitis in cervical carcinoma patients receiving radiotherapy.