• Title/Summary/Keyword: Total ozone column

Search Result 20, Processing Time 0.022 seconds

Intercomparison and evaluation of satellite-derived tropospheric ozone (인공위성을 이용한 대류권 오존 추정치 비교 및 검증)

  • Kim Jae-Hwan;Na Seon-Mi;M. J. Newchurch
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.123-124
    • /
    • 2003
  • Fishman and Larson (1987) derived tropical tropospheric column ozone by subtracting stratospheric column ozone measured by the Stratospheric Aerosol and Gas Experiment (SAGE) from total column ozone obtained by the Total Ozone Mapping Spectrometer (TOMS). Later, the Convective Cloud Differential (CCD) method (Ziemke et al., 1998) indicated stratospheric ozone is invariant with longitude and concluded the zonal variation of total ozone determines the zonal variation of tropospheric ozone. (omitted)

  • PDF

Enhancement of Ozone and Carbon Monoxide Associated with Upper Cut-off Low during Springtime in East Asia

  • Moon, Yun-Seob;Drummond, James R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.475-489
    • /
    • 2010
  • In order to verify the enhancement of ozone and carbon monoxide (CO) during springtime in East Asia, we investigated weather conditions and data from remote sensors, air quality models, and air quality monitors. These include the geopotential height archived from the final (FNL) meteorological field, the potential vorticity and the wind velocity simulated by the Meteorological Mesoscale Model 5 (MM5), the back trajectory estimated by the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, the total column amount of ozone and the aerosol index retrieved from the Total Ozone Mapping Spectrometer (TOMS), the total column density of CO retrieved from the Measurement of Pollution in the Troposphere (MOPITT), and the concentration of ozone and CO simulated by the Model for Ozone and Related Chemical Tracers (MOZART). In particular, the total column density of CO, which mightoriginate from the combustion of fossil fuels and the burning of biomass in China, increased in East Asia during spring 2000. In addition, the enhancement of total column amounts of ozone and CO appeared to be associated with both the upper cut-off low near 500 hPa and the frontogenesis of a surface cyclone during a weak Asian dust event. At the same time, high concentrations of ozone and CO on the Earth's surface were shown at the Seoul air quality monitoring site, located at the surface frontogenesis in Korea. It was clear that the ozone was invaded by the downward stretched vortex anomalies, which included the ozone-rich airflow, during movement and development of the cut-off low, and then there was the catalytic photochemical reaction of ozone precursors on the Earth's surface during the day. In addition, air pollutants such as CO and aerosol were tracked along both the cyclone vortex and the strong westerly as shown at the back trajectory in Seoul and Busan, respectively. Consequently, the maxima of ozone and CO between the two areas showed up differently because of the time lag between those gases, including their catalytic photochemical reactions together with the invasion from the upper troposphere, as well as the path of their transport from China during the weak Asian dust event.

Ozone-Enhanced Remediation of Diesel-Contaminated Soil (II): A Column Study (Ozone에 의한 유류오염토양 복원 연구 (II) : 토양 컬럼상에서의 오존 산화)

  • Choi, Heechul;Heechul;Lim, Hyung-Nam;Kim, Kwang-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1825-1832
    • /
    • 2000
  • Column experiments were conducted by using soil columns, to investigate feasibility and efficiency of in-situ ozone enhanced remediation for diesel-contaminated soil. The injection of gaseous ozone into soil column revealed the enhanced decomposition of ozone due to the catalytic reaction between ozone and metal (e.g., Fe, Mn etc.) oxides as evidenced by as much as 25 times shorter half-life of ozone in a sand packed column than in a glass beads packed column. Substantial retardation in the transport of and the consumption of ozone were observed in the diesel contaminated field soil and sand packed columns. After 16 hrs ozonation, 80% of the initial mass of diesel (as diesel range organic) concentration of $800{\pm}50mg/kg$, was removed under the conditions of the flow rate of 50mL/min and $6mg-O_3/min$. Whereas, less than 30% of diesel was removed in the case of air injection. Analysis of the residual TPH(total petroleum hydrocarbon) and selected 8 aliphatics of diesel compounds in the inlet and the outlet of the column confirmed that diesel nonselectively reacted with ozone and then shifted to lower carbon numbered molecules. Water content also was found to be an important parameter in employing ozone to the hydrocarbon-contaminated soil.

  • PDF

Monitoring and Long-term Trend of Total Column Ozone from Dobson Spectrophotometer in Seoul (1985~2017) (돕슨 분광광도계를 이용한 서울 상공의 오존층 감시 및 장기변화 경향(1985~2017))

  • Park, Sang Seo;Cho, Hi Ku;Koo, Ja-Ho;Lim, Hyunkwang;Lee, Hana;Kim, Jhoon;Lee, Yun Gon
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.13-20
    • /
    • 2019
  • Since 1985, the Dobson Spectrophotometer has been operated at Yonsei University, and this instrument has monitored the daily representative total ozone in Seoul. Climatological value for total ozone in Seoul is updated by using the daily representative observation data from 1985 to 2017. After updating the daily representative total ozone data, seasonal and inter-annual variation of total ozone in Seoul is also estimated after calculating inter-comparison between ground (Dobson Spectrophotometer) and satellite [Total Ozone Mapping Spectrometer (TOMS) and Ozone Monitoring Instrument (OMI)] observations. The global average of total ozone measured by satellite is 297 DU, and its recent amount is about 3.5% lower than the global amount in 1980s. In Seoul, daily representative total ozone is ranged from 225 DU to 518 DU with longterm mean value of 324.3 DU. In addition, monthly mean total ozone is estimated from 290 DU (October) to 362 DU (March), and yearly average of total ozone have been continuously increased since 1985. For the long-term trend of total ozone in Seoul, this study is considered the seasonal variation, Solar Cycle, and Quasi-Biennial Oscillation. In addition to the natural oscillation effect, this study also considered to the long-term variation of sudden increase of total ozone due to the secondary ozone peak. By considering these natural effects, the long-term total ozone trends from 1985 to 2017 are estimated to be 1.11~1.46%/decade.

Optimal Estimation (OE) Technique to Retrieve the Ozone Column and Tropospheric Ozone Profile Based on Ground-based MAX-DOAS Measurement (오존전량 및 대류권 오존 프로파일 산출을 위한 지상관측 MAX-DOAS 원시자료 기반의 최적추정(Optimal Estimation) 기술)

  • Park, Junsung;Hong, Hyunkee;Choi, Wonei;Kim, Daewon;Yang, Jiwon;Kang, Hyungwoo;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.2_1
    • /
    • pp.191-201
    • /
    • 2018
  • In this present study, we, for the first time, retrieved total column of ozone ($O_3$) and tropospheric ozone vertical profile using the Optimal Estimation (OE) method based on the MAX-DOAS measurement at the Yonsei University in Seoul, Korea. The optical density fitting is carried out using the OE method to calculate ozone columns. The optical density between the MAX-DOAS data obtained by dividing the measured intensities for each viewing elevated angle by those at the zenith angle. The retrieved total columns of the ozone are 375.4 and 412.6 DU in the morning (08:13) and afternoon (17:55) on 23 May, 2017, respectively. In addition, under 10 km altitude, the $O_3$ vertical profile was retrieved with about 5% of retrieval uncertainty. However, above 10 km altitude, the $O_3$ vertical profile retrieval uncertainty was increased (>10%). The spectral fitting errors are 16.8% and 19.1% in the morning and afternoon, respectively. The method suggested in this present study can be useful to measure the total ozone column using the ground-based hyper-spectral UV sensors.

Evaluation of the Total Column Ozone in the Reanalysis Datasets over East Asia (동아시아 지역 오존 전량 재분석 자료의 검증)

  • Han, Bo-Reum;Oh, Jiyoung;Park, Sunmin;Son, Seok-Woo
    • Atmosphere
    • /
    • v.29 no.5
    • /
    • pp.659-669
    • /
    • 2019
  • This study assesses the quality of the total column ozone (TCO) data from five reanalysis datasets against nine independent observation in East Asia. The assessed datasets are the ECMWF Interim reanalysis (ERAI), Monitoring Atmosphere Composition and Climate reanalysis (MACC), Copernicus Atmosphere Monitoring Service reanalysis (CAMS), the NASA Modern-Era Retrospective analysis for Research and Applications, Version2 (MERRA2), and NCEP Climate Forecast System Reanalysis (CFSR). All datasets reasonably well capture the spatial distribution, annual cycle and interannual variability of TCO in East Asia. In particular, characteristics of TCO according to the latitude difference were similar at all points with a maximum bias of less than about 4%. Among them, CAMS and CFSR show the smallest mean bias and root-mean square error across all nine ground-based observations. This result indicates that while TCO data in modern reanalyses are reasonably good, CAMS and CFSR TCO data are the best for analysing the spatio-temporal variability and change of TCO in East Asia.

Distribution of Tropical Tropospheric Ozone Determined by the Scan-Angle Method applied to TOMS Measurements

  • Kim, Jae-H.;Na, Sun-Mi;Newchurch, M. J.;Emmons, L.
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.7-11
    • /
    • 2002
  • This study introduces the first method that determines tropospheric ozone column directly from a space-based instrument. This method is based on the physical differences in the Total Ozone Mapping Spectrometer (TOMS) measurement as a function of its scan-angle geometry. Tropospheric ozone in September-October exhibits a broad enhancement over South America, the southern Atlantic Ocean, and western South Africa and a minimum over the central Pacific Ocean. Tropical tropospheric ozone south of the equator is higher than north of the equator in September-October, the southern burning season. Conversely, ozone north of the equator is higher in March, the northern burning season. Overall, the ozone over the southern tropics during September-October is significantly higher than over the northern tropics. Abnormally high tropospheric ozone occurs over the western Pacific Ocean during the El Nino season when the ozone amounts are as high as the ozone over the Africa.

  • PDF

PAHs 오염 토양내 오존이동특성;함수율과 수분과 토양 유기물의 영향

  • 배기진;정해룡;최희철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.140-143
    • /
    • 2001
  • The packed column experiments were conducted with commercial Jumunjin sand(SOM content : 0.01 %) and a field soil(SOM content : 0.08 %) in order to understand the effects of water content and soil organic matter(SOM) on the transport of gaseous ozone in unsaturated soil contaminated with phenanthrene. Water content and SOM content were artificially controlled. As water content increased, earlier breakthrough was observed in the beginning of BTC of ozone, because direct contact of gaseous ozone with SOM and phenanthrene was prevented by water film formed between soil particles and gaseous ozone. The total removal of phenanthrene in Jumunjin sand was not affected by water content which was more than 99% at different water content(4.4, 8, 17.3%). However, the removal in field soil at water content 6.5 % and 20 % was 98% and 80 %.

  • PDF

Analyses of the OMI Cloud Retrieval Data and Evaluation of Its Impact on Ozone Retrieval (OMI 구름 측정 자료들의 비교 분석과 그에 따른 오존 측정에 미치는 영향 평가)

  • Choi, Suhwan;Bak, Juseon;Kim, JaeHwan;Baek, KangHyun
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.117-127
    • /
    • 2015
  • The presences of clouds significantly influence the accuracy of ozone retrievals from satellite measurements. This study focuses on the influence of clouds on Ozone Monitoring instrument (OMI) ozone profile retrieval based on an optimal estimation. There are two operational OMI cloud products; OMCLDO2, based on absorption in $O_2-O_2$ at 477 nm, and OMCLDRR, based on filling in Fraunhofer lines by rotational Raman scattering (RRS) at 350 nm. Firstly, we characterize differences between $O_2-O_2$ and RRS effective cloud pressures using MODIS cloud optical thickness (COT), and then compare ozone profile retrievals with different cloud input data. $O_2-O_2$ cloud pressures are significantly smaller than RRS by ~200 hPa in thin clouds, which corresponds to either low COT or cloud fraction (CF). On the other hand, the effect of Optical centroid pressure (OCP) on ozone retrievals becomes significant at high CF. Tropospheric ozone retrievals could differ by up to ${\pm}10$ DU with the different cloud inputs. The layer column ozone below 300 hPa shows the cloud-induced ozone retrieval error of more than 20%. Finally, OMI total ozone is validated with respect to Brewer ground-based total ozone. A better agreement is observed when $O_2-O_2$ cloud data are used in OMI ozone profile retrieval algorithm. This is distinctly observed at low OCP and high CF.

Simple tropospheric ozone retrieval from TOMS and OMI

  • Kim, Jae-Hwan;Kim, So-Myoung;Na, Sun-Mi
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.253-256
    • /
    • 2006
  • When the background tropospheric ozone column over the Pacific Ocean is subtracted from the latitudinal total ozone distribution, the results show remarkable agreement with the latitudinal stratospheric ozone distribution using the CCD. The latitudinal tropospheric ozone distribution using the CCD method, with a persistent maximum over the southern tropical Atlantic, is also seen in the latitudinal tropospheric ozone distribution using the T-P method. It suggests that the CCD method can be replaced by the simple T-P method. However, the tropical Atlantic paradox exists in the results of both the CCD and T-P methods during the northern burning season. In order to investigate this paradox, we compare the latitudinal ozone distributions using the CCD and T-P methods by using the SAGE measurements (e.g. TSA method) and the SHADOZ ozonesoundings (e.g. T-S method) assuming zonally invariant stratospheric ozone, which is the same assumption as of the CCD method. During the northern burning season, the latitudinal distributions in the tropospheric ozone derived from the T-SA and T-S methods show higher tropospheric ozone over the northern tropical Atlantic than the southern Atlantic due to a stronger gradient in stratospheric ozone relative to that from the CCD and T-P methods. This indicates that the latitudinal tropospheric ozone distribution can be changed depending on the data that is used to determine the latitudinal stratospheric ozone distribution. Therefore, there is a possibility that the north-south gradient in stratospheric ozone over the Atlantic can be a solution of the paradox.

  • PDF