• 제목/요약/키워드: Total flow velocity

Search Result 381, Processing Time 0.033 seconds

An instability criterion for viscoelastic flow past a confined cylinder

  • Dou, Hua-Shu;Phan-Thien, Nhan
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.1
    • /
    • pp.15-26
    • /
    • 2008
  • It has been known that there is a viscoelastic instability in the channel flow past a cylinder at high Deborah (De) number. Some of our numerical simulations and a boundary layer analysis indicated that this instability is related to the shear flow in the gap between the cylinder and the channel walls in our previous work. The critical condition for instability initiation may be related to an inflection velocity profile generated by the normal stress near the cylinder surface. At high De, the elastic normal stress coupling with the streamline curvature is responsible for the shear instability, which has been recognized by the community. In this study, an instability criterion for the flow problem is proposed based on the analysis on the pressure gradient and some supporting numerical simulations. The critical De number for various model fluids is given. It increases with the geometrical aspect ratio h/R (half channel width/cylinder radius) and depends on a viscosity ratio ${\beta}$(polymer viscosity/total viscosity) of the model. A shear thinning first normal stress coefficient will delay the instability. An excellent agreement between the predicted critical Deborah number and reported experiments is obtained.

Interfacial Condensation Heat Transfer for Countercurrent Steam-Water Stratified Flow in a Circular Pipe

  • Chu, In-Cheol;Chung, Moon-Ki;Yu, Seon-Oh;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.142-156
    • /
    • 2000
  • An experimental study of steam condensation on a subcooled thick water layer (0.018 ~0.032 m) in a countercurrent stratified flow has been performed using a nearly horizontal circular pipe. A total of 103 average interfacial condensation heat transfer coefficients were obtained and parametric effects of steam and water flow rates and the degree of subcooling on condensation heat transfer were examined. The measured local temperature and velocity distributions in the thick water layer revealed that there was a thermal stratification due to the lack of full turbulent thermal mixing in the lower region of the water layer Two empirical Nusselt number correlations, one in terms of average steam and water Reynolds numbers, and the water Prandtl number, and the other in terms of the Jakob number in place of the Prandtl number, which agree with most of the data within $\pm$ 25%, were developed based on the bulk flow properties. Comparisons of the present data with existing correlations showed that the present data were significantly lower than the values predicted by existing correlations.

  • PDF

A Study on the Flow Coefficient Test and Numerical Analysis about 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump (보일러 급수펌프용 1500lb 고차압 제어밸브 유량시험 및 수치해석에 관한 연구)

  • Lee, Kwon-Il;Jang, Hoon;Lee, Chi-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.541-547
    • /
    • 2022
  • Before making a prototype, we predicted the inlet/outlet differential pressure and flow coefficient, which are the most basic design data for the valve through the design and numerical analysis of the trim, which is the most important in the localization development of the 1500Ib high differential pressure control valve used for boiler feed water. As a result, the design value and the analysis value were found to be about 98% similar. The flow field within the fluid velocity of 23m/s to prevent cavitation was also found. The result of the numerical analysis on thermal stress due to the characteristics of valves exposed to high temperatures showed that it was found to be about 18% less than the allowable stress of the bolt fixing the trim. When all loads such as pressure, self-weight, and vibration are applied, however, it is judged to go beyond the currently calculated thermal stress, exceeding the allowable stress.

Numerical Modeling of Wave-Type Turbulent Flow on a Stepped Weir (계단형 보에서의 파형 난류 흐름 수치모의)

  • Paik, Joongcheol;Lee, Nam-Ju;Yoon, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.575-583
    • /
    • 2017
  • Various types of flow patterns around the stepped weir and spillway, such as the skimming flow over such structures and the wave-type flow with a standing undular hydraulic jump and roller downstream of the structures, are developed in open channels. Unsteady three-dimensional numerical simulations are carried out using a hybrid RANS-LES turbulence modeling approach and the volume of fluid method for resolving free surface fluctuations to represent the turbulent flow including the skimming flow and wave-type flow over a stepped weir installed in a rectangular channel. The comparison of numerical results with an existing experimental measurement reveals that the present numerical simulations reasonably well reproduce the turbulent flow passing the stepped weir, in terms of time-averaged velocity profiles at selected locations downstream of the weir, flow topology characterized by the wave-type and skimming flows, the maximum height and length of the standing wave and the length of reattachment of recirculating zone. The numerical result further elucidates the distinct flow behaviors of the wave-type and skimming flow by presenting instantaneous intense variations of free surface and velocity vectors, the distributions of Reynolds shear stress and turbulent kinetic energy and three-dimensional complex features of coherent structures and total pressure distribution.

A New Scale(NS) Score System to Predict Outcome of Intracranial Aneurysm Using TCD (TCD를 이용한 두개강내 동맥류의 예후 예측 가능한 New Scale(NS) Score System)

  • Park, Sang Hoon;Park, Chong Oon;Park, Hyeon Seon;Hyun, Dong Keun;Ha, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.970-975
    • /
    • 2001
  • Objective : By conducing a review of clinical outcomes for patients with aneurysm treated using current microneurosurgical techniques and intensive care unit management, we speculated that grading systems based only on clinical condition or CT finding after admission failed to provide a significant stratification of outcome between individual grades of patients, because these systems did not include the factor for postoperative vasospasm. We hypothesized that postoperative blood flow velocity could have a significant impact on outcome prediction for patients surgically treated for intracranial aneurysms. Methods : We conducted a analysis on patient- and lesion-specific factors that might have been associated with outcome in a series of 55 aneurysm operations performed with measurements of blood-flow velocity with transcranial Doppler ultrasonography(TCD). In the new scale(NS) score system, 1 point is assigned additionally for the case with Hunt and Hess(H-H)/World Federation of Neurological Surgeons(WFNS) Grade IV or V, Fisher Scale(FS) score 3 or 4, aneurysm size greater than 10mm, patient age older than 60 years, blood-flow velocity higher than 120cm/sec, and posterior circulation lesion. By adding the total points, a 6-point scale score(score 0-6) is obtained. Results : Age of patient, size of aneurysm, clinical condition(H-H grade and WFNS), FS score, and blood flow velocity(TCD 1day after operation) were independently and strongly associated with long-term outcome. When NS scores were applied to 55 patients with at least 6 months follow-up, the correlation of individual scores with outcome was strongly validated the retrospective findings. Conclusion : It was speculated that TCD could be used to assess postoperative vasospasm and to monitor noninvasively the patients with aneurysmal SAH. This NS score system is easy to apply, divide patients into groups with different outcome, and is comprehensive, allowing for more accurate prediction of surgical outcome.

  • PDF

Experimental Study on Effects of Inlet Boundary Layer Thickness and Boundary Layer Fence in a Turbine Cascade (터빈 캐스케이드 입구경계층 두께와 경계층 펜스 효과에 대한 실험적 연구)

  • Jun, Y.M.;Chung, J.T.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.853-858
    • /
    • 2000
  • The working fluid from the combustor to the turbine stage of a gas turbine makes various boundary layer thickness. Since the inlet boundary layer thickness is one of the important factors that affect the turbine efficiency. It is necessary to investigate secondary flow and loss with various boundary layer thickness conditions. In the present study, the effect of various inlet boundary layer thickness on secondary flow and loss and the proper height of the boundary layer fences for various boundary layer thickness were investigated. Measurements of secondary flow velocity and total pressure loss within and downstream of the passage were taken under 5 boundary layer thickness conditions, 16, 36, 52, 69, 110mm. It was found that total pressure loss and secondary flow areas were increased with increase of thickness but they were maintained almost at the same position. At the fellowing research about the boundary layer fences, 1/6, 1/3, 1/2 of each inlet boundary layer thickness and 12mm were used as the fence heights. As a result, it was observed that the proper height of the fences was generally constant since the passage vortex remained almost at the same position. Therefore once the geometry of a cascade is decided, the location of the Passage vortex and the proper fence height are appeared to be determined at the same time. When the inlet boundary layer thickness is relatively small, the loss caused by the proper fence becomes bigger than endwall loss so that it dominates secondary loss. In these cases the proper fence hight is decided not by the cascade geometry but by the inlet boundary layer thickness as previous investigations.

  • PDF

Spatio-temporal Distribution Patterns of Lotic Benthic Macroinvertebrate Communities in Namhan-River Weir Section (남한강 보 구간 유수성 저서성 대형무척추동물의 시·공간적 분포 특성)

  • Kim, Jin-Young;Lee, Seung-Hyun;Lee, Kyung-Lak;Noh, Seongyu;Shin, Yuna;Lee, Su-Woong;Lee, Jaekwan;Won, Doo-hee;Lim, Sung-ho;Kown, Yongju;Kong, Dongsoo
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.4
    • /
    • pp.331-344
    • /
    • 2018
  • Lotic organisms in streams are affected by natural and anthropogenic disturbances such as increase of heavy rainfall event caused by climate change and flow regime change caused by weir constructions. Based on domestic and foreign literature, 157 Korean benthic macroinvertebrate taxa were selected species as potential lotic candidates. Three shoreline sites (total 54 samples) were surveyed consecutively before ('08~'09), during ('10~'12) and after ('13~'16) the construction of the weirs (Gangcheon, Yeoju and Ipo weir) in the Namhan-River for tracing changes of lotic communities. As a result, water flow of the Ipo-wier and water quality variables such as T-N, T-P, BOD5, etc. of the weir section revealed no significant changes. Physical habitat conditions such as the flow velocity and streambed substrate evidently changed. Particulary, flow velocity measured at sampling points along with each microhabitat drastically decreased and particle size of streambed substrate steadily decreased after weir constructions. Lotic organisms also decreased after construction, especially Hydropsychidae (insecta: Trichoptera) acutely decreased from $3,526ind.\;m^{-2}$ to $2ind.\;m^{-2}$ As a result of CCA, lotic species such as Hydropsyche valvata, Hydropsyche kozhantschikovi, Cheumatopsyche brevilineata, Cheumatopsyche KUa, Macrostemum radiatum, etc. correlated with the flow velocity, streambed substrate. Therefore, the decrease of the flow velocity and substrate size after weir construction seemed to be closely related to the decrease of the individual abundances of the lotic organisms independently of water quality. In order to evaluate the influence of the ecosystem on the flow regime change more accurately, it is necessary to study the indicator species based on the resistance or preference of the flow.

Heat and mass transfer analysis in air gap membrane distillation process for desalination

  • Pangarkar, Bhausaheb L.;Sane, Mukund G.
    • Membrane and Water Treatment
    • /
    • v.2 no.3
    • /
    • pp.159-173
    • /
    • 2011
  • The air gap membrane distillation (AGMD) process was applied for water desalination. The main objective of the present work was to study the heat and mass transfer mechanism of the process. The experiments were performed on a flat sheet module using aqueous NaCl solutions as a feed. The membrane employed was hydrophobic PTFE of pore size 0.22 ${\mu}m$. A mathematical model is proposed to evaluate the membrane mass transfer coefficient, thermal boundary layers' heat transfer coefficients, membrane / liquid interface temperatures and the temperature polarization coefficients. The mass transfer model was validated by the experimentally and fitted well with the combined Knudsen and molecular diffusion mechanism. The mass transfer coefficient increased with an increase in feed bulk temperature. The experimental parameters such as, feed temperature, 313 to 333 K, feed velocity, 0.8 to 1.8 m/s (turbulent flow region) were analyzed. The permeation fluxes increased with feed temperature and velocity. The effect of feed bulk temperature on the boundary layers' heat transfer coefficients was shown and fairly discussed. The temperature polarization coefficient increased with feed velocity and decreased with temperature. The values obtained were 0.56 to 0.82, indicating the effective heat transfer of the system. The fouling was observed during the 90 h experimental run in the application of natural ground water and seawater. The time dependent fouling resistance can be added in the total transport resistance.

Mathematical modeling of humidification process by means of hollow fiber membrane contactor

  • Marjani, Azam;Baghdadi, Ali;Ghadiri, Mehdi
    • Membrane and Water Treatment
    • /
    • v.7 no.4
    • /
    • pp.297-311
    • /
    • 2016
  • Modeling and simulation of air humidification by hollow fiber membrane contactors are investigated in the current study. A computational fluid dynamic model was developed by solving the k-epsilon turbulence 2D Navier-Stokes equations as well as mass conservation equations for steady-state conditions in membrane contactors. Finite element method is used for the study of the air humidification under different operating conditions, with a focus on the humidity density, total mass transfer flux and velocity field. There has been good agreement between simulation results and experimental data obtained from literature. It is found that the enhancement of air stream decreases the outlet humidity from 0.392 to 0.340 (module 1) and from 0.467 to 0.337 (module 2). The results also indicated that there has been an increase in air velocity in the narrow space of shell side compared with air velocity wide space of shell side. Also, irregular arrangement has lower dead zones than regular arrangement which leads to higher water flux.

Case-control Study : Cerebral Blood Flow as Measured by TCD in Patients with Risk Factors for Stroke (TCD를 이용한 정상군과 중풍원인질환군의 혈류측정에 관한 비교연구)

  • Heo, Jeong-Eun;Kwon, Jung-Nam;Shin, Won-Tak;Kim, Jong-Deuk;Lee, Sang-Hee;Son, Yeoun-Hui;Kim, Young-Kyun
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.2
    • /
    • pp.250-261
    • /
    • 2007
  • Objectives : The purpose of this study was to evaluate the blood flow using doppler ultrasound of the MCA, ACA, PCA, BA, ICA in the patients with risk factor for stroke. Methods : 110 patients with risk factor for stroke were selected who had hypertension, diabetes mellitus, hyperlipidemia, or heart disease, as well as 89 healthy adults who did not have any symptoms of those diseases. To evaluate the blood flow, the Vs and Vm of the MCA, ACA, PCA, BA, and ICA in the two groups were measured. Result : In normal healthy adults, subjects showed a decrease in the Vs and Vm: with advancing in age, there was a significant difference in the Vs of MCA, PCA, BA, and ICA. There was a significant difference in the Vm of MCA, PCA, BA, and ICA. In normal healthy adults, females showed high velocities in all examined vessels. There was a significant difference in the Vs of BA. There was a significant difference in the Vm of BA, and ICA. There was a decrease in the Vs, and Vm of all examined vessels of patients with risk factors for stroke in comparison with normal healthy adults. There was no significant difference in the Vs. There was a significant difference in the Vm of MCA, ACA, and PCA. Results were the same between patients aged under 50 and total patients in the Vs and Vm of examined vessels. There were differences between patients aged over 50 and total patients in the Vs of MCA, PCA, BA and for patients aged over 50; patients with risk factor for stroke who had hypertension, diabetes mellitus, hyperlipidemia, or heat disease has higher Vs than healthy adults. Conclusions : There was a significant difference in the blood flow velocity between patients with risk factors for stroke and healthy adults. However, this result was different from results of comparison of TCD findings between patients and healthy individuals by age. Therefore, more detailed studies about aged patients are needed.

  • PDF