• Title/Summary/Keyword: Total collection efficiency

Search Result 109, Processing Time 0.026 seconds

Collection Efficiency of Electrostatic Precipitator using Moment Method (모멘트 방법을 이용한 전기집진기의 집진 효율)

  • 정창훈;이규원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.345-353
    • /
    • 2002
  • A study of polydispersed aerosol dynamics by Electrostatic Precipitator (ESP) was carried out. The log-normal particle size distribution was assumed and moment method was considered. In order to apply moment method in Deutsch-Anderson equation, Cunningham slip correction factor and Cochet's charge equation were simplified for certain range of particle size. The three parameters, which explain the particle size distribution, such as total number concentration, geometric mean diameter, and geometric standard deviation were considered to derive the analytic solution. The obtained solution was compared with available numerical results (Bai et al., 1995). The comparison of the numerical and analytic results showed a good agreement.

Determination of Two-Lane Highway Capacity and Level of Service in Korean Rural Roads (우리나라 양방향 2차선 도로의 용량 및 서비스 수준 체계에 관한 연구)

  • 최재성
    • Journal of Korean Society of Transportation
    • /
    • v.9 no.1
    • /
    • pp.5-18
    • /
    • 1991
  • Two-Lane, two-way roads account for approximately 92% of total road length in Korea and accomplish the majority of regional transport activities. Nevertheless not too many research have been made on two-lane roads particularly efficiency related topics such as capacity and travel time studies. In this study a full scale data collection was conducted using video equippments on rural two-lane roads to determine capacity Passenger Car Equivalents(PCE) and Level of Service criterion. Various PC programs were utilized to reduce traffic data and Walker ME? and Headway Method were employed to determine PCE's for heavy vehicles. The reseach has shown that capacity and PCE's for two-land two-way roads in Korea are 3200 pcph and 1.1∼1.9 resectively. In addition percent time delay was used as the basis of developing Level of service criterion on two-lane roads in Korea.

  • PDF

LED Lens for Rectangular Beam with Small Divergence Angles

  • Liu, Dianhong;Zhang, Xiaohui;Zhang, Shuang
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.739-744
    • /
    • 2016
  • We have designed a new TIR(Total Internal Reflection) structure for generating an LED lens which can produce a rectangular beam with small divergence angle in two perpendicular directions for an optical guidance system. The lens can control the divergence angle in the horizontal direction to be a small value of about $8^{\circ}$ with a $1mm{\times}1mm$ LED source, also in the vertical direction it can be about $7^{\circ}$, with optical collection efficiency higher than 0.83. After the lens is manufactured, the work demonstrates that the lens is suitable for an optical guidance system.

Effect of Semen Collection Methods on the Post-thaw Viability of Cat Semen (고양이의 정액 채취 방법이 동결 정액의 생존성에 미치는 영향)

  • Ha, A-Na;Yoon, Jin-Ho;Kim, Yu-Gon;Jo, A-Na;Lee, Kyeong-Rim;Kong, Il-Keun
    • Reproductive and Developmental Biology
    • /
    • v.35 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • The objective of this study was carried out to evaluate the efficiency of sperm collection methods on the post-thaw viability of cat semen. The cat semen was collected by artificial virginal (AV) and electronic ejaculate (EE) methods. The composition of semen extender was consisted of Tris-buffer supplemented with 20% egg yolk and 1% P/S antibiotics in Ext I, and more added 8% glycerol, 1.0% Equex STM paste of total volume in Ext II. The collected semen was adjusted the concentration and then diluted in Ext I for optimal concentration. The diluted semen was cooling to $5^{\circ}C$ temperature in refrigerator for at least 2 hrs and then diluted stepwise with Ext II for at least 1 hrs. After an equilibration for 1 hrs, the cooled semen was packaged in 0.5 ml straw and then freezing on the $LN_2$ vapor over 5 cm above from $LN_2$ and then immersed directly in $LN_2$ for cryopreservation. The frozen semen was thawed in $38^{\circ}C$ water for 15 sec and then evaluated the motility, viability, and morphology. Post-thaw semen were calculated the motility by SMI (sperm motility index). The live-dead sperm was evaluated by Eosin-B and morphological evaluation was by Diff-quik kit staining. The post-thaw concentration ($89{\times}10^6$ /ml vs. $128{\times}10^6$ /ml), viability ($22.6{\pm}10.6%$ vs. $37.1{\pm}26.1%$), morphological normality ($27.0{\pm}50.2%$ vs. $45.6{\pm}123.0%$) of EE and AV groups were not significant different, but the post-thaw motility was significant lower in EE than that in AV group ($53.1{\pm}3.6$ vs. $73.6{\pm}5.7$) (p<0.05). In conclusion, semen collection methods did not significant different between EE and AV groups except of post-thaw motility and so both semen collection methods could be applied in feline semen collection methods.

Development of an intelligent IIoT platform for stable data collection (안정적 데이터 수집을 위한 지능형 IIoT 플랫폼 개발)

  • Woojin Cho;Hyungah Lee;Dongju Kim;Jae-hoi Gu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.687-692
    • /
    • 2024
  • The energy crisis is emerging as a serious problem around the world. In the case of Korea, there is great interest in energy efficiency research related to industrial complexes, which use more than 53% of total energy and account for more than 45% of greenhouse gas emissions in Korea. One of the studies is a study on saving energy through sharing facilities between factories using the same utility in an industrial complex called a virtual energy network plant and through transactions between energy producing and demand factories. In such energy-saving research, data collection is very important because there are various uses for data, such as analysis and prediction. However, existing systems had several shortcomings in reliably collecting time series data. In this study, we propose an intelligent IIoT platform to improve it. The intelligent IIoT platform includes a preprocessing system to identify abnormal data and process it in a timely manner, classifies abnormal and missing data, and presents interpolation techniques to maintain stable time series data. Additionally, time series data collection is streamlined through database optimization. This paper contributes to increasing data usability in the industrial environment through stable data collection and rapid problem response, and contributes to reducing the burden of data collection and optimizing monitoring load by introducing a variety of chatbot notification systems.

Retrieval of Porcine Ovarian Follicles by Different Methods

  • Choi, Moon Hwan;Gong, Seung Pyo;Lim, Jeong Mook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.3
    • /
    • pp.353-357
    • /
    • 2008
  • A series of studies has been conducted to establish a base infrastructure for an ovarian follicle culture system in the porcine and this study was designed to develop an effective retrieval protocol of preantral follicles. Five different methods using collagenase type I (A) or IV (B, C1, C2 and C3), which employed different treatment durations and/or conditions, were employed and sliced ovarian tissue of prepubertal gilts was provided for the retrieval. A significant increase in total number of follicles retrieved was detected when collagenase IV (methods B or C) was used. In total, more ovarian follicles were retrieved by method B undertaking agitation and method C2 without the agitation than method C1 and C3, while the number of preantral follicles collected was the largest in method B. Neither incubation in 5% $CO_2$ in air atmosphere instead of the agitation nor increased duration of enzymatic treatment up to 120 minutes improved the efficiency of follicle retrieval. There were no differences in the number of follicles retrieved from intact ovaries and from used ovaries for oocyte collection. These results demonstrate the collagenase IV treatment with agitation is effective for retrieving porcine preantral follicles from the ovaries.

Information needs and Information-seeking behaviour of auto mechanics in Siwdu, Cape Coast, Ghana

  • Afful-Arthur, Paulina;Filson, Christopher Kwame
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.9 no.1
    • /
    • pp.7-18
    • /
    • 2019
  • The main objective of the study is to find out the level of information-seeking behaviour of auto mechanics working at Siwdu and its impact on the work they do. Two methods of data collection instruments were used; these included a questionnaire and interview schedule. The researchers personally administered fifty-three questionnaires of which forty-eight completed ones were received. Twelve (12) people were interviewed at their respective workshops. The respondents were registered members of Siwdu Auto Mechanic Association and the total number of sixty respondents used represented 20% of total number of members. Quantitative data obtained mainly from the questionnaire were analysed using Statistical Package for Social Sciences (SPSS) software version 20. Responses for the interview were analysed thematically. Some of the major findings are as follows: The majority of the respondents did not know how to get information from the library; some of the respondents preferred consulting their "Masters" for help; majority of the respondents had Android phones but did not know how to access relevant information; respondents were aware of the benefits of authentic information; and respondents recommended that Management of libraries should organise seminars and workshops for auto mechanics to enable them know how and where to access information. Information is needed by everybody to enhance efficiency therefore creating the awareness of the sources of information is a way of increasing productivity. Knowing the level of information-seeking behaviour of people in every manner of job is essential in the nation's human resource development.

Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos (공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교)

  • Jang, Bong-Ki;Tak, Hyun-Wook;Song, Su-Jin;Jo, Bong-Hyun;Kim, Yeong-Ji;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

Investigation on Sorting Efficiency for Recyclable Materials and Its Improvement Measure at Domestic Sorting Facility (국내 재활용품 선별시설에서 선별 현황 및 개선방안)

  • Kim, Joo-Sin;Pak, Daewon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.15-26
    • /
    • 2017
  • This study was conducted to investigate and analyze the discharge characteristics of recyclable material from S-city, S-district, in order to improve the sorting efficiency in recycling sorting facility. The characteristics of recyclable materials collected were analyzed in three different scopes; source origin, collection and transportation, and sorting steps. The average of recyclable waste generation is $0.121kg/day^*man$. Regional collection period appears to be three times a week, and the density of mixed recyclable wastes showed the average of $202.4kg/m^3$ in the waste collection vehicle. In the analysis into the sorting steps, the average of carrying amount of mixed recycling products is 1,154.6 ton/month, the average of appeared density is $181kg/m^3$, the average amount of separated recycling products is 448.5kg/month, and the density of recycling residue is found out to be $48kg/m^3$. The sorting rate of recyclable material is 38.85% and the percentage of residues is 55.90%. Out of 7,744.8 tons of the total recyclable residues, 4,272.1 tons were found out to be possible recylable materials. As a result of increasing the recycling rate of residues, the encouragement of base-recycling, the automation and retrofit of sorting equipment, and energy recovery from recycling residue were discussed.

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.