스윕을 가진 냉각탑용 축류홴의 성능 특성에 관한 수치해석적 연구 (Numerical Investigation of Performance Characteristics for Cooling Tower Axial Fans with Sweep)

  • 오건제
    • 동력기계공학회지
    • /
    • 제13권4호
    • /
    • pp.31-37
    • /
    • 2009
  • The purpose of this numerical study was to investigate performance characteristics for cooling tower axial fans with sweep. Performance data for the fans with various sweep angles were obtained in terms of the setting angle at a constant flow rate. Viscous flow calculations were carried out to obtain Performance data of the total pressure rise and hydraulic efficiency. A solution of the Ffowcs Williams-Hawkings equations was used to calculate the sound pressure level at three times fan diameter away from the fan. The calculated performance data well represented performance characteristics of the cooling tower axial fan. The total pressure rise and hydraulic efficiency at the same setting angle decreased with sweep angle. Sound pressure level slightly decreased for the fan with a sweep angle of 10 degree. No significant effect of the sweep geometry was found on the sound pressure level.

  • PDF

송풍기 설부 주변 유동의 개선에 관한 연구 (Study on improvements for flows near cut-off region in blower)

  • 김재원;박진원
    • 한국전산유체공학회지
    • /
    • 제8권1호
    • /
    • pp.1-7
    • /
    • 2003
  • The present study has conducted the analysis of flows in a blower with double suction. The air handling system is for supplying air flows into a plant. The present system has a couple of impellers in axial direction for enhanced flow rate. Main interest lies on the improvements of static pressure rise and total efficiency of the system. The present treatment of the reform is to secure a spatial distance between the fan and the casing of the system and change the shape of the cut-off part. The resultant performance after the reform shows increased pressure-rise and efficiency of the system

한국어 파열자음의 인두내압, 폐쇄기 및 Voice Onset Time(VOT)에 관한 실험적 연구 (The Experimental Study on the Intraoral Pressure, Closure Duration, and Voice Onset Time(VOT) of Korean Stop Consonants)

  • 표화영;심현섭;박헌이;최재영;최성희;안성복;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제10권1호
    • /
    • pp.50-57
    • /
    • 1999
  • A study to get the data of normal stop consonants production as preliminary study for cleft palate patients was performed. Normal Korean native 21 speakers were pronounced $VCV(V=/a/,C=/P/,/{P^1}/,/P^h/,/t/,/{t^1}/,/{t^h}/,/k/,/{k^1}/,/{k^h}/)$ syllables with natural speech rate and intensity. With intrapharyngeal pressure waveforms by pressure sensor in oropharyngeal cavity, amplitude and time duration of intrapharyngeal pressure were analyzed, and with acoustic waveforms and spectrograms, closure duration and VOT were analyzed. As results, the highest amplitude of intrapharyngeal pressure showed in alveolars and heavily aspirated consonants. Velars and unaspirated consonants were higher than bilabials and slightly aspirated ones each, in intrapharyngeal pressure. Bilabilas, alveolars and velars showed similar rise time of intrapharyngeal pressure build-up, but in decay time and total duration time, bilabials were slightly shorter than alveolars and velars, with no statistic significance. In the aspects of tensity, unaspirated consonants showed the longest rise time, heavily aspirated, the second, and slightly aspirated consonants, the shortest, which were also seen in decay time and total duration time. In closure duration, slightly aspirated consonants had the shortest closure duration, and the heavily aspirated ones, the second, and unaspirated consonants showed the longest. In VOT, heavily aspirated consonants showed the longest, slightly aspirated ones, the second and unaspirated ones showed the shortest.

  • PDF

압력보정법을 이용한 8개의 원심압축기 임펠러 CFD의 적용 연구 (Application of Pressure Correction Method to CFD Work for 8 Centrifugal Compressor Impellers)

  • 오종식;노수혁;현용익
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.226-235
    • /
    • 2000
  • Two representative finite volume methods, i.e., the time marching method and the pressure correction method, were applied to 8 centrifugal compressor impeller flows, with low to very high level of pressure ratio, among which 7 impellers' experimental performance is given in the open literature. The present study is focused on the prediction differences from both methods, developed by the authors, in the pressure correction method's point of view. In all cases, the time marching method gives a satifactory solution, but the pressure correction method does not. Up to about $18\%$ less level of total-to-total pressure ratio is predicted by the pressure correction method as the level of the impeller pressure ratio increases up to about 10. The drop of total pressure ratio is caused by the underestimation of static pressure rise which seems to be attributed to inappropriate linearization and discretization of the pressure/density coupling terms in the pressure correction equation.

  • PDF

凝縮을 隨伴하는 超音速 노즐흐름의 全壓損失 (Total Pressure Loss in a Supersonic Nozzle Flow with Condensation)

  • 강창수;권순범
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.582-589
    • /
    • 1988
  • 본 연구에서는 작동유체로서 습공기를 사용하였을때 수반되는 응축에 의한 전 압손실을 실험과 수치해석을 통하여 정체점에 있어서의 습공기의 온도, 과포화도 및 노즐 팽창율의 효과와 액적 질량비 (g)과의 관계로서 구명하였다.

실측과 시뮬레이션을 통한 초고층 주거건물에서의 연돌효과 문제의 해결 (Solving the Problems Caused by Stack Effect in a High-rise Residential Building through Field Measurement and Simulation; Case Study)

  • 구성한;조재훈;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제16권4호
    • /
    • pp.73-80
    • /
    • 2005
  • A high-rise residential building experienced stack effect problems during the winter such as difficulties in opening residential entrance doors and whistling noise from elevator doors generated by airflow. Field measurements were carried out on the building and the problems were verified by the analysis of the measurement results from three points of view: the total stack pressure difference, pressure distribution on each floor, and the location of the neutral pressure level. Based on the analysis of the three key parameters, possible solutions were proposed, such as zoning vertical shafts, lessening the airflow from the entrance doors on basement floors and lobby floor by installing vestibules, improving the airtightness of exterior walls, and installing separation doors where the problems occur. Simulations of proposed solutions were conducted and the effects of reducing the pressure difference were evaluated. Stack effect problems in a high-rise residential building were verified through field measurements and could be mitigated by the solutions which were drawn from the analysis of the field measurements and the simulation results.

농도성층화와 Cooled EGR이 DME HCCI 엔진의 운전영역에 미치는 영향에 관한 수치해석 (An Investigation of Effects of Fuel Stratification and Cooled EGR on DME HCCI Engine's Operating Ranges by Numerical Analysis)

  • 정동원;아마라;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제21권2호
    • /
    • pp.129-135
    • /
    • 2010
  • Homogeneous charge compression ignition (HCCI) engines have the potential to provide both diesel-like efficiency and very low emissions of nitrogen oxide (NOx) and particulate matter(PM). However, several technical issues still must be resolved before HCCI can see application. Among these, steep pressure-rise rate which leads to narrow operating range of HCCI engine continues to be a major issue. This work investigates the combination of two methods to mitigate the excessive pressure-rise rates at high power output, namely fuel stratification and Cooled exhaust-gas recirculation (Cooled EGR), after identifying the each effects to pressure-rise rate. When applying the fuel stratification to simulation, total fuelling width of 0.15 at BDC is set as a equivalent ratio difference based on the previous research. In order to simulate the effects of cooled EGR, $CO_2$ mole fraction in pre-mixture is changed ranging from 0 to 30%. DME which has a characteristic of two-stage ignition is used as a fuel.

냉각탑용 축류형 F.R.P. 팬의 개발 (Development of an Axial F.R.P. Fan for Cooling Tower)

  • 오건제;김선숙
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.735-741
    • /
    • 2007
  • An axial F.R.P. fan model for cooling tower is developed. The fan is designed using the equations for one dimensional inviscid flow through the fan blade. Fan shape is swept forward with a parabolic function. Calculations of the three dimensional turbulent flow around the fan are carried out to investigate performance of the fan. Data of the total pressure rise and hydraulic efficiency can be obtained for the various setting angles. Calculated values of the total pressure rise and hydraulic efficiency at the design point are less than those of the design specification. The prototype of the F.R.P. fan is made by laminating of the fiberglass and epoxy resins on the mold of fan shape.

성층연소에 관한 실험적 기초연구 (A fundamental investigation on the stratified charged combustion)

  • 조경국;정인석;정인승
    • 오토저널
    • /
    • 제3권3호
    • /
    • pp.39-48
    • /
    • 1981
  • The combustion phenomena of the stratified charged model combustion chamber under the initial conditions of the room temperature and the atmospheric pressure were investigated by using pressure record and high speed Schliern motion picture in comparison with that of the uniformly charged case. The results show that the total burning time is strongly dependent on the turbulent spouting flame jet speed which promotes the combustion process inside the chamber, and the pressure rise-up of stratified charged combustion is rather faster and higher than that of uniformly charged combustion, which can be resulted in the energy saving.

  • PDF

Numerical Analysis for High-rise Building Foundation and Further Investigations on Piled Raft Design

  • Won, Jinoh;Lee, Jin Hyung;Cho, Chunwhan
    • 국제초고층학회논문집
    • /
    • 제4권4호
    • /
    • pp.271-281
    • /
    • 2015
  • This paper introduces detailed three-dimensional numerical analyses on a bored pile foundation for a high-rise building. A static load test was performed on a test pile and a numerical model of a single pile, which was calibrated by comparing it with the test result. The detailed numerical analysis was then conducted on the entire high-rise building foundation. Further study focused on soil pressures under the base slab of a piled raft foundation. Total seven cases with different pile numbers and raft-soil contact conditions were investigated. The design criteria of a foundation, especially settlement requirement were satisfied even for the cases with fewer piles under considerable soil pressure beneath the base slab. The bending moment for the structural design of the base slab was reduced by incorporating soil pressures beneath the base slab along with bored piles. Through the comparative studies, it was found that a more efficient design can be achieved by considering the soil pressure beneath the slab.