• Title/Summary/Keyword: Total Pressure Distribution

Search Result 334, Processing Time 0.019 seconds

Analysis of Bale Surface Pressure According to Stretch Film Layer Changes on Round Bale Wrapping

  • Hong, Sungha;Kang, Daein;Kim, Daeyeon;Lee, Sangsik
    • Journal of Biosystems Engineering
    • /
    • v.42 no.3
    • /
    • pp.136-146
    • /
    • 2017
  • Purpose: This paper presents an appropriate wrapping method by analyzing the pressure distribution applied to a bale surface, along with the change in pressure according to an increase in the number of film layers in rice straw bales, which account for 74% of the total bulky feed supply in Korea. Methods: A model with the shape of an actual bale was fabricated to analyze the distribution of surface pressure in bale wrapping, and the pressure was measured. Experiments were conducted to analyze the pressure using eight different layer numbers (2, 4, 6, 8 10, 12, 14, and 16 layers) at five wrapping speeds (27, 29, 31, 33, and 35 rpm). Results: The maximum pressure applied to a circular bale by the film occurred at the center of the end of the bale, whereas the minimum pressure occurred at the center of the bale side. An extreme value ratio between the minimum and maximum pressures was distributed as 8.5-56.6%, which was improved with an increase in rotation speed. The an uneven pressure distribution occurred because the number of film overlaps was 8.24-times greater at the center of the bale's end than at the center of the ba le side. At a level 5 rotation speed, the minimum pressure was $P_{LV5-M1}=0.0625{\sigma}^2+36.173{\sigma}-36.753$ ($R^2=0.9845$) at $M_1$, and the maximum pressure was $P_{LV5-M6}=5.5552{\sigma}^2+41.05{\sigma}-39.071$ at $M_2$, revealing a correlation of $R^2=0.9983$. Conclusions: To replace four layers with six layers, 2-4 layers were added only to the side of the bale, and the minimum pressure at $M_1$ was then improved from that at four layers to that at six layers, and the amount of film consumed for 4-6 layers was reduced by 84.6%.

Numerical Study on Propeller Cavitation and Pressure Fluctuation of Model and Full Scale ship for a MR Tanker (MR Tanker 실선 및 모형선 프로펠러 캐비테이션 및 변동압력 수치해석 연구)

  • Park, Il-Ryong;Kim, Ki-Sup;Kim, Je-In;Seol, Han-shin;Park, Young-Ha;Ahn, Jong-Woo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • Propeller cavitation extent, pressure fluctuation induced by cavitation, pressure distribution on propeller blade, total velocity distribution and nominal wake distribution for a MR Taker were computed in both conditions of model test and sea trial using a code STAR-CCM+. Then some of the results were compared with model test data at LCT and full-scale measurement (Ahn et al (2014); Kim et al (2014)] in order to confirm the availability of a numerical prediction method and to get the physical insight of local flow around a ship and propeller. The nominal wake distributions computed and measured by LDV velocimeter on the variation of on-coming velocity show the wake contraction characteristics proposed by Hoekstra (1974). The numerical prediction of propeller cavitation extent on a blade angular position and pressure fluctuation level on each location of pressure sensors are very similar with the experimental results.

Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone (드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정)

  • Kim, Heesang;Park, Yonghe;Kim, Wooyoung;Eun, Heeram;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

Multi-block Technique for a duct flow with multiple outlets (다출구 덕트 유동 해석을 위한 복합 격자망 해석방법의 제안)

  • Jeon,Yong-Deok;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1416-1425
    • /
    • 1996
  • A numerical method has been proposed to predict 3-dimensional flow in a duct system with multiple outlets. For the duct system, it is supposed that the pressure values are given at multiple outlets while the velocity profile is given at a inlet. To maintain the continuity of pressure distribution between main and branch duct, present method allows that the pressure value taken from analysis of branch duct can be converted to the main duct analysis. The result from present method which can handle the pressure boundary condition closely coincided with that from regular method which can handle the velocity boundary condition only. Furthermore the flow distribution from present method showed good agreement with that from the single block method. From the comparison of the present method with the total pressure method used for engineering duct design, 13% of discrepancy in pressure loss was shown between the main duct inlet and the branch duct outlet.

The Comparison of Plantar Pressure on Double Limb Support and Single Limb Support according to Soft Surface (연성면에 따른 양발지지와 한발지지 시 족저압 비교)

  • Lee, Jeon-Hyeong;Chung, Hyeung-Jae;Kim, Shin-Gyun
    • PNF and Movement
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • Purpose : The purpose of this study was to investigate a plantar pressure distribution and the trajectory of the center of pressure on double limb support and single limb support according to level surface, air cushion, and aero step. Methods : 21 healthy adults participated in this study. The plantar pressure were assessed at three different surface conditions(on the level surface, air cushion, and aero step) on double limb support and single limb support. Testing orders were selected randomly. Results : Plantar pressure distribution show a significant difference contact area 1 and contact area 3 on double limb support and single limb support. The trajectory of the center of pressure show an significant difference anteroposterior(AP), mediolateral(ML), and total displacement on double limb support and single limb support. Conclusion : Through the use of soft surface as air cushion and aero step will be using the ankle strategy. This will be to strengthen the muscles around the ankle. Consequently, should help to improve stability and coordination.

A Computerized Axial Flow Fan Design System for Noise and Performance Analysis (성능 및 소음 해석 기능이 수반된 전산화된 축류 송풍기 설계 체제)

  • Chung, Dong-Kyu;Noh, Jun-Gu;Seo, Jae-Young;Lee, Chan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.37-42
    • /
    • 2001
  • A computerized axial flow fan design system is developed with the capabilities for predicting the aerodynamic performance and the noise characteristics of fan. In the present study, the basic fan blading design is made by combining vortex distribution scheme with camber line design, airfoil selection, blade thickness distribution and stacking of blade elements. With the designed fan blade geometry, the through-flow field and the performance of fan are analyzed by using the streamline curvature computing scheme with spanwise total pressure loss and flow deviation models. Fan noise is assumed to be generated due to the pressure fluctuation induced by wake vortices of fan blades and to radiate as dipole distribution. The vortex-induced fluctuating pressure on blade surface is calculated by combining thin airfoil theory and the predicted flow field data. The predicted performances, sound pressure level and noise directivity patterns of fan by the present method are favorably compared with the test data of actual fans. Furthermore, the present method is shown to be very useful in designing the blade geometry of new fan and optimizing design variables of the fan to achieve higher efficiency and lower noise level.

  • PDF

Microstructure and shear modulus in concentrated dispersions of bidisperse charged spherical colloids

  • Chun, Myung-Suk;Lee, Sangwoo;Lee, Tae-Seok;Cho, Jae-Seol
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2004
  • We examine rigorous computations on microstructural as well as rheological properties of concentrated dispersions of bidisperse colloids. The NVT Monte Carlo simulation is applied to obtain the radial distribution function for the concentrated system. The long-range electrostatic interactions between dissimilar spherical colloids are determined using the singularity method, which provides explicit solutions to the linearized electrostatic field. The increasing trend of osmotic pressure with increasing total particle concentration is reduced as the concentration ratio between large and small particles is increased. From the estimation of total structure factor, we observe the strong correlations developed between dissimilar spheres. As the particle concentration increases at a given ionic strength, the magnitude of the first peak in structure factors increases and also moves to higher wave number values. The increase of electrostatic interaction between same charged particles caused by the Debye screening effect provides an increase in both the osmotic pressure and the shear modulus. The higher volume fraction ratio providing larger interparticle spacing yields decreasing high frequency limit of the shear modulus, due to decreasing the particle interaction energy.

Influence of Pressure Reducing Valves on Flow Characteristics of the Water Supply System for an Apartment Complex (공동주택단지 급수계통의 유량특성에 미치는 감압밸브의 영향)

  • Kim, Tae Jin;Cha, Dong Jin
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.23-28
    • /
    • 2012
  • Pressure distribution in the water supply system of an apartment complex consisting of 12 buildings and 635 units in total have been investigated numerically. The complex incorporates two zone booster pump system, and around a half of units have pressure reducing valves (PRVs) in them. Calculated hydrostatic pressure without the water flow were compared with their designed and measured counterparts, and they agreed quite well with each other. Then, the pressure and volumetric water flow rate at all units were analyzed, indicating that there are noticeable differences in pressure and flow rate in one unit to another, although the aforementioned minimization technologies of pressure deviation were employed. In order to further reduce the difference in the water flow rate, it is suggested that all the units in the complex have PRVs installed in their water supply system. The effect of setting pressure of the PRVs on the non-uniformity of the flow in each unit and on the reduction of total water supply for the apartment complex have been studied. With the same PRV setting pressure of 3.952 bar (or the gauge pressure of $3.0kg_f/cm^2$), it has been estimated that the suggested system improves the non-uniformity (the coefficient of variation) of the flow rate of apartment complex over the current system, from 8.02% to 6.66%, and reduces the total water supply, from $0.02804m^3/s$ to $0.02766m^3/s$.

The Comparison of Characteristics of Foot pressure between Treadmill and Ground walking in Normal person (정상인의 평지보행과 트레드밀 보행 시 족저압의 특성 비교)

  • Kim, Ji-Hye;Oh, Tae-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.1
    • /
    • pp.53-61
    • /
    • 2010
  • Purpose : The purpose of this study is to compare the distribution of foot pressure, knee and ankle joint angle between treadmill walking and ground walking in normal person. Methods : 18 Person of subject has participated this study, let subject to walk in ground and treadmill in order to gain data of foot distribution and knee, ankle joint angle using by parotec system. and Dartfish system. Walking velocity was constrained by 2Km/h and more 10sec. Date analysis was used by paired-t test using SPSS/PC statistical programs for window. Results : Result show that total contact times has shown symmetry between both legs, and more increase of left foot pressure in treadmill walking. Foot pressure of treadmill walking was significantly decreased in right hind foot and fore foot and hallux area. The ankle joint angle of treadmill walking was significantly decreased in initial contact phase. Conclusion : Results of this study show that foot pressure of treadmill walking was more decreased than ground walking in right hind foot and fore foot, hallux area. And the ankle joint angle of treadmill walking was significantly decreased in initial contact phase.

The Immediate Effects of Elastic Taping on Center of Pressure and Foot Pressure Distribution

  • Jung-Hee Kim;Jong-Ho Kook;Sang-Mi Lee;Eun-Bin Ko;Song-Yi Han;Yeon-Jeong Kim;Byeong-Jun Min
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.23-30
    • /
    • 2024
  • Purpose: Ankle instability is a common issue in both daily activities and sports, often leading to recurrent injuries. Elastic taping is a non-pharmacological intervention used to improve ankle stability. This study aimed to investigate the immediate effects of elastic taping on ankle stability, center of pressure (COP) movement, and foot pressure distribution. Methods: A single-group pre-posttest design was employed, with 30 participants included in the study. Plantar pressure and COP parameters were measured before and after the application of elastic taping. Taping was administered in three distinct patterns to enhance ankle stability. Results: Immediate effects of elastic taping were evident in COP parameters. Following taping application, there was a significant decrease in COP total displacement, COP area, and COP velocity. However, no significant changes were observed in plantar pressure parameters. Conclusion: The application of elastic taping in this study demonstrated immediate effects on ankle stability and COP parameters, indicating its potential as a viable intervention for improving balance. Further research with larger sample sizes and long-term follow-up is needed to elucidate the sustained effects of elastic taping on ankle stability.