• Title/Summary/Keyword: Total Heat Release

Search Result 142, Processing Time 0.028 seconds

A Study for Thermal Mechanism of Residential Combustibles with Numerical Modeling (주거공간 단위가연물의 열역학적 수치해석 모델링에 관한 연구)

  • Ahn, Chan-Sol;Kim, Jung-Yup;You, Yong-Ho;Kweon, Oh-Sang;Joo, Sang-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.58-63
    • /
    • 2011
  • This study is intended to present a computational thermal model for the combustibles in a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the thermal properties of the residential combustible fire, we made some numerical models of combustibles in a residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator was used with Large Eddy Simulation model for turbulence. Consequently, each heat release rate and total heat release curves were successfully estimated.

Numerical analysis on the rapid fire suppression using a water mist nozzle in a fire compartment with a door opening

  • Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.410-423
    • /
    • 2019
  • Fire suppression using a water mist nozzle directly above an n-Heptane pool in a fire compartment with a door opening was numerically investigated using the Fire Dynamics Simulator (FDS) for the purpose of application in nuclear power plants. Input parameters for the numerical simulation were determined by experimental measurements. Water mist was activated 10 s after the fire began. The sensitivity analysis was conducted for three input parameters: total number of cubic cells of 6032-2,926,400, droplets per second of 1000-500,000, and extinguishing coefficient of 0-100. In a new simple calibration method of this study, the extinguishing coefficient yielding the fire suppression time closest to that measured by experiments was found for use as the FDS simulation input value. When the water mist jet flow made contact with the developed fire, the heat release rate instantaneously increased, and then rapidly decreased. This phenomenon occurred with a displacement of the flame near the liquid fuel pool. Changing the configuration of the door opening with different aspect ratios and opening ratios had impact on the maximum value of the heat release rate due to the flame displacement.

A Fire Hazard Assessment of Interior Finish Materials (건물 내장재의 화재위험성 평가 방법)

  • 김운형
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.17-28
    • /
    • 1998
  • To propose a new fire hazard assessment criteria of interior finish materials, the properties and incident heat flux of interior finish materials in a compartment fires are investigated and compared by using flame spread model developed by Quintiere. The properties considered on which fire growth depend are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. ISO Room Corner Test(9705) is applied in the model and the time for total energy release rate to reach 1MW is examined. The results are compared for the 24 different materials tested by EUREFIC. Dimensionless parameter a, b and ${\gamma}$b are used to develope a new method in which fire hazard of interior finish materials can be classified resulting from correlation between b and flashover time. Results show that if b greater than about zero, flashover time in the ISO Room-Corner Test is principally proportional to ignition time only.

  • PDF

Development of a 250-W high-power modular LED fish-attracting lamp by evaluation of its thermal characteristics

  • Lee, Donggil;Lee, Kyounghoon;Pyeon, Yongbeom;Kim, Seonghun;Bae, Jaehyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.2
    • /
    • pp.163-170
    • /
    • 2015
  • Recently LED fish-attracting lamps have been more widely used in fisheries as low-cost and high-efficiency fishing gear, and development of long-life high-efficiency lamps is required through the design of LED packages to optimize heat resistance. This study developed an improved LED fish-attracting lamp with excellent heat performance, which was verified using a numerical model. Heat-resistance design factors such as the heat-radiation fin shape, PCB type, and LED chip count were investigated and optimized. Comparison with a commercial 180-W LED fishing lamp showed that the increase in initial temperature was 40% higher than that of the surrounding LED chip because of design errors in contact thermal resistance. The 250-W LED lamp developed in this study has a characteristic with thermal rising in linearly stable according to the heat source. In addition, luminance efficiency was improved by 20-65% by using flow-visualization simulation. A decrease of 45% in total power consumption with a fuel-cost reduction of over 55% can be expected when using these optimized heat release design factors.

Synthesis of Triazole-functionalized Phenolic Resin and its Inherent Flame Retardant Property

  • Poduval, Mithrabinda K.K.;Kim, Tae-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3249-3253
    • /
    • 2014
  • A novel triazole-functionalized phenolic resin was developed, and its thermal and flame-retardant properties were investigated. The triazole group was incorporated as a pendant unit on the phenolic resin via copper-mediated click chemistry between propargylated phenolic resin and benzyl azide. The newly-developed triazole-functionalized phenolic resin showed higher thermal stability and char yield, together with a reduced total heat release (THR), than the non-functionalized bare phenolic resin, indicating enhanced flame retardancy for the triazole-functionalized phenolic resin.

Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content (현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험)

  • Moon, Min-Ho;Yang, So-Yeon;Han, Kuk-Il;Lee, Ji-Hee;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, the fire patterns, heat emissions, and smoke generated by means of fire tests developed for representative combustibles in residential facilities were analyzed from among seven fire types. These combustibles were selected in a previous study to simulate real-world situations and professionalism required while dealing with these types of fires and develop the field commander training content. Consequently, the maximum heat dissipation was recorded as 728.6 kW, followed by the dissipation measured from the combination of a mattress and electric blanket, desk and chair, and TV and mattress. The total heat emission of sofas (226.2 MJ) and the combination of mattress and electric blanket (2,259.5 ㎡) was recorded. In this study, the scope of the tests was limited to the fire characteristics and characteristics of the combustibles, and it is expected that a simulation using various data acquisition methods and FDS would be performed and evaluated at a later stage.

Combustion Characteristics of Cypress Specimens Painted with Solutions of Boron Compounds (붕소 화합물로 처리된 편백나무 시험편의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • The combustion characteristics of cypress wood coated with boric acid (BA) and ammonium pentaborate (APB) were examined using a cone calorimeter according to the ISO 5660-1 standard. As a result, the combined specimens of boric acid and ammonium pentaborate (BA/APB) led to an improved fire performance index due to their synergistic effect. In addition, the total heat release values of the specimen coated with the boron compounds were 6.1~14.1% lower than that of the base specimen. The total smoke release rate (TSR) of the specimens coated with the boron compound decreased throughout the combustion process, except for BA/APB. The maximum concentration of carbon monoxide was reduced by 15.8~25.5%. In general, wood treated with flame retardants has a lower fire hazard.

Assessment of Gas Release Dispersion and Explosion in Pipeline (파이프라인에서의 가스누출 확산과 폭발 영향평가)

  • Jung In-Gu;Yoo Sang-Bin;Lee Su-Kyung;Kim Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.61-69
    • /
    • 1998
  • The risk assessments for gas leak in underground pipeline are conducted about the explosion accident of AHYUN-DONG underground service-base on December, 1994(Gaussian gas, LNG) and the accident of TAEGU subway on April 1995(Heavy gas LPG). We have calculated the total mass of gas release and have respected the efficient of explosions with report of the spot. The dispersion zones of LNG were calculated as large as fifteen times to those of LPG by ALOHA. The effects of thermal radiation from LNG explosion were assumed less than that from LPG by PHAST.

  • PDF

Combustive Properties of Low Density Polyethylene and Ethylene Vinyl Acetate Composites Including Magnesium Hydroxide (저밀도 폴리에틸렌과 에틸렌 비닐 아세테이트에 수산화마그네슘을 첨가한 복합체의 연소성)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.69-75
    • /
    • 2011
  • It was performed to test the combustive properties of low density polyethylene and ethylene vinyl acetate (LDPE-EVA) composite by the addition of magnesium hydroxide. Flame retardant of natural magnesium hydroxide was added to the mixture of LDPE-EVA in 40 to 80 wt% concentration. The composite was compounded to prepare specimen for combustive analysis by cone calorimeter (ISO 5660-1). Comparing with virgin LDPE-EVA, the specimens including the magnesium hydroxide had lower flashover possibility. It is supposed that the combustive properties in the composites decreased due to the endothermic decomposition of magnesium hydroxide. The specimens with magnesium hydroxide showed both the lower total heat release rate (THR) and lower CO production rate than those of virgin polymer. As the magnesium hydroxide content increases, the total smoke release (THR) and smoke extinction area (SEA) decreased.

Combustion Properties of the Quercus variabilis and Zelkova serrata Dried at Room Temperature (II) (자연 건조된 굴참나무와 느티나무 목재의 연소성(II))

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.469-474
    • /
    • 2010
  • Wood has an essential drawback such as high combustion ability. The purpose of this paper is to examine the combustion properties of the quercus variabilis and zelkova serrata dried at room temperature. The cone calorimeter (ISO 5660-1) was used to determine the heat release rate (HRR) and fire smoke index, as well as CO/$CO_2$ production and smoke obscuration. The total heat release (THR), $140.2\;MJ/m^2$ of the quercus variabilis under an external $50\;kW/m^2$ was high in comparison with THR $85.7\;MJ/m^2$ for the zelkova serrata. Furthermore, the quercus variabilis has high total smoke production (TSP), $3.50\;m^2$ compared with TSP $0.65\;m^2$ of zelkova serrata. Thease results depend on the bulk density of tested wood species. In addition, the CO/$CO_2$ production ratio of zelkova serrata and quercus variabilis was measured as 0.053, 0.043, respectively. Also, zelkova serrata showed an increase of fire-resistance attributed to char formation compared with that of quercus variabilis.