• Title/Summary/Keyword: Total Energy Consumption

Search Result 1,000, Processing Time 0.025 seconds

Evaluation on the thermal performance of earth plastering utilizing eco-friendly materials (친환경재료를 활용한 흙미장의 단열성능 평가)

  • Yang, Jun-Young;Hwang, Hey-Zoo;Oh, Yang-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.85-88
    • /
    • 2012
  • Lately, the scale of the primary energy consumption in Korea is ranked 10th in the world, and it takes up about 1.9% of the entire energy consumption in the world. And among total energy consumption in Korea, the ratio of the part corresponding to the residence or commercial buildings is about 30.5%. Also, with the increased interest in eco-friendly buildings, the production of eco-friendly building materials consisting of them also increases as well. However, since the process of their production generates much energy consumption, so this is being raised as a social problem. Therefore, this study suggests a method to improve thermal performance by using eco-friendly earth plastering materials and natural materials in order to reduce energy consumption in buildings. The experiment evaluated thermal performance by measuring the external and internal temperature of the curing after the plastering of 1cm in the wooden box of 30cm * 30cm * 30cm. As a result, there was difference in the order of powdered coal, pealite, chaff, and rice straw. Among them, powdered coal indicated excellent thermal performance. This will be the foundational research used to improve interior environment and reduce heating bills.

  • PDF

A Study on Energy Savings Analysis by Controling LED Lighting according to the Change of the Amount of Daylight (주광량의 변화에 따른 LED조명 제어를 통한 에너지 절감량 분석에 관한 연구)

  • Ham, Won-Tae;Chae, Soo-Yong;Han, Soo-Bin;Kim, Heung-Geun;Jung, Hak-Guen
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.522-528
    • /
    • 2012
  • Currently, the energy consumption of electric lighting in an office building is accounted for more than 30% of the total energy consumption. In order to reduce the energy consumed by the indoor lighting, the daylight as a natural energy resource can play an important role in energy savings. The daylight can have positive impacts on improvement of work efficiency and productivity, and also make people feel more psychologically stable. Moreover, by using the daylight, we can definitely reduce the energy consumption in office buildings. Thus, the purpose of this study is to determine the LED dimming ratio depending on the ratio by calculating the amount of artificial illumination required according to the change of daylight by using the light simulation software that can quantify and visualize the performance of daylight. As a result, the energy savings could be obtained up to 30%.

  • PDF

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

The Study of Alcohol Consumption and Nutritional Status of University Male Freshman in Rural Area (일부 지방 대학 남자 신입생의 알코올 섭취와 영양소 섭취상태에 관한 연구)

  • Choe, Mi-Gyeong;Seung, Jeong-Ja;Kim, Mi-Hyeon
    • Journal of the Korean Dietetic Association
    • /
    • v.7 no.3
    • /
    • pp.267-273
    • /
    • 2001
  • The purpose of this study was to investigate the relationship between alcohol consumption and nutritional status of university male freshman in Chungnam area. The total of 111 subjects took part in the study and, they were observed general characteristics, alcohol consumption status, and nutrient intake using questionnaires. The mean age, height, weight, and BMI of the subjects were 19.3 years, 174.3㎝, 65.2㎏, and 21.5㎏/$m^2$ respectively. The mean alcohol consumption, and energy intake from alcohol were 7.8g/day, 55.3kcal/day. A significant number of subjects(48.2%) answered their frequency of alcohol consumption was once 2 weeks. Only 4.6% of subjects answered never drink. In almost subjects, alcohol consumption have been stared since they were adolescents, and major type of alcoholic beverage was 'soju'. The mean energy intake was 1985.6kcal and, energy ratio from carbohydrate, protein, fat was 58 : 15 : 27. There were significantly positive correlation among alcohol consumption and, body weight(p<0.05), intake of food, (p<0.05), energy(p<0.001), animal fat(p<0.05), fiber(p<0.05), vitamin $B_2$(p<0.05) and niacin(p<0.05). The alcohol consumption period showed a significantly positive correlation with alcohol consumption per one time(p<0.05). In summary, high consumption of alcohol in subjects was observed. Also, increase of alcohol consumption was related to weight gain and nutritional imbalance. Therefore, it is need that nutrition education for prevention of high alcohol consumption in university freshman and adolescents.

  • PDF

Energy Demand/Supply Prediction and Simulator UI Design for Energy Efficiency in the Industrial Complex (산업단지 에너지 효율화를 위한 에너지 수요/공급 예측 및 시뮬레이터 UI 설계)

  • Hyungah Lee;Jong-hyeok Park;Woojin Cho;Dongju Kim;Jae-hoi Gu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.693-700
    • /
    • 2024
  • As of the end of March 2022, the total area of domestic industrial complexes is 606 km2, which is only about 0.6% of the total land area. However, as of 2018, the annual energy consumption of domestic industrial complexes is 110,866.1 thousand TOE, accounting for 53.5% of the country's total energy consumption and 83.1% of the entire industrial sector energy consumption. In addition, industrial complexes have a significant impact on the environment, accounting for 45.1% of the country's total greenhouse gas emissions and 76.8% of industrial sector greenhouse gas emissions. Under this background, in this study, in order to contribute to the energy efficiency of industrial complexes, a prediction study on energy demand and supply for an industrial complex in Korea using machine learning was conducted. In addition, a simulator UI screen was designed to more efficiently convey information on energy demand/supply prediction results and energy consumption status. Among the machine learning algorithms, Multi-Layer Perceptron (MLP) was used, and Bayesian Optimization was applied as an optimization technique for the prediction model. The energy prediction model for the industrial complex built in this study showed a prediction accuracy of 87.90% for compressed air demand and 99.54% for the flow rate available for the public air compressor.

Network Coding for Energy-Efficient Distributed Storage System in Wireless Sensor Networks

  • Wang, Lei;Yang, Yuwang;Zhao, Wei;Lu, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.9
    • /
    • pp.2134-2153
    • /
    • 2013
  • A network-coding-based scheme is proposed to improve the energy efficiency of distributed storage systems in WSNs (Wireless Sensor Networks). We mainly focus on two problems: firstly, consideration is given to effective distributed storage technology; secondly, we address how to effectively repair the data in failed storage nodes. For the first problem, we propose a method to obtain a sparse generator matrix to construct network codes, and this sparse generator matrix is proven to be the sparsest. Benefiting from this matrix, the energy consumption required to implement distributed storage is reduced. For the second problem, we designed a network-coding-based iterative repair method, which adequately utilizes the idea of re-encoding at intermediate nodes from network coding theory. Benefiting from the re-encoding, the energy consumption required by data repair is significantly reduced. Moreover, we provide an explicit lower bound of field size required by this scheme, which implies that it can work over a small field and the required computation overhead is very low. The simulation result verifies that the proposed scheme not only reduces the total energy consumption required to implement distributed storage system in WSNs, but also balances energy consumption of the networks.

A Study on Prediction of Power Consumption Rate of Middle School Building in Changwon City by Regression Analysis (회귀분석을 통한 창원시 중학교 전력소비량 예측에 관한 연구)

  • Cho, Hyeong-Kyu;Park, Hyo-Seok;Choi, Jeong-Min;Cho, Sung-Woo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.12 no.2
    • /
    • pp.61-70
    • /
    • 2013
  • As the existing school building power consumption is expressed by total power consumption, in the view of energy saving is disadvantage. The the power consumption of school building is divided as cooling, heating, lighting and others. The cooling power consumption, heating power consumption, lighting power consumption can be calculated using real total power consumption that gained from Korea Electric Power Corporation(KEPCO). The power consumption for cooling and heating can be calculated using heat transmittance, wall area and floor area, and for lighting is calculated by artificial lighting calculation. but this calculation methods is difficult for laymen. This study was carried out in order to establish the regression equation for cooling power consumption, heating power consumption, lighting power consumption and other power consumption in school building. In order to verify the validity of the regression equation, it is compared regression equation results and calculation results based on real power consumption. As the results, difference between regression result and calculation results for cooling and heating power consumption showed 0.6% and 3.6%.

Physiological analysis of mountain climbing exercise (등산운동의 생리학적 분석)

  • Kim, Wan-Tai;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.5 no.2
    • /
    • pp.15-27
    • /
    • 1971
  • Physiological analysis of the physical exercise was made on 9 subjects performing mountain climbing. The course between two points (256 and 516 meters altitude) was 1,300 meters in distance and difference of vertical height was 260 meters making the mean grade of 20%. In the field, the heart rates during uphill or downhill walk were recorded by EKG radio-telemetry. In the laboratory, oxygen consumption was obtained by the recorded heart rates, using individual heart rate vs oxygen consumption diagram obtained by treadmill test. the following results were obtained. 1. Uphill walk time was 36.5 minutes, and during this period the mean heart rate was 149.0 heats/min and peak heart rate was 169.2 beats/min. The total heart beats during the uphill walk was 5.433 beats. 2. The ratio of individual mean heart rate during the uphill walk to the maximal heart rate distributed between 66.6% and 98.3%, and the mean of the total group was 83.1%. The ratio of peak heart rate of uphill walk to the maximal heart rate was 94.5% in the group. Thus uphill walk of a 20% grade mountain course was an exhaustive exercise. 3. Oxygen consumption during uphill walk was 2.22 l/min (ranged between 1.79 and 2.70 l/min) and the ratio of this to the resting oxygen consumption was 8.31. The peak value of oxygen consumption during uphill walk was 2.73 l/min and the ratio of this to the resting oxygen consumption was 10.39. 4. Energy expenditure during uphill walk showed a mean of 11.1 kcal/min and the peak expenditure rate was 13.6 kcal/min. The total energy expenditure during 36.5 minutes of uphill walk was 396 kcal. 5. In downhill walk, the time was 31.7 minutes, mean heart rate was 118.4 (ranged between 100.1 and 142.7) beats/min, and the peak heart rate was only 129.4 beats/min. The ratio of mean heart rate to the maximal heart rate was 66.3%. Total heart beats during downhill walk was 3,710 beats. The ratio of downhill oxygen consumption to the resting consumption was 5.70. The rate of energy expenditure was 7.5 kcal/min, and the total onery expenditure during the 31.7 minutes of downhill walk was 228 kcal. 6. The effect of training was manifest in the uphill walk and not in the downhill walk. After training in mountain course walk, i) the uphill time was shortened, ii) mean heart rate increased, iii) time vs heart rate curve became smooth and showed less frequent zig-zag, i.e., the depth of trough on the curve decreased and the magnitude was less than 10 beats. In non-trained subject the depth of trough on the curve was greater than 50 beats and appeared more frequently. 7. Mountain climbing is a good health promotion exercise. For the promotion of health the reasonable amount of uphill mountain walk exercise in a 20% grade course is a walk for 40 or 50 minutes duration once a week.

  • PDF

Effects of Food Consumption Monitoring Using a Camera-Phone on Body Weight and Serum Lipid Level in Obese Female College Students (비만여대생을 대상으로 카메라폰을 이용한 음식섭취 모니터링 강화에 의한 체중 및 혈청지질 감소 효과)

  • Kim, Young-Suk;Kim, Yun-Joo;Hong, In-Sun;Kim, Seon-Hee;Chang, Un-Jae
    • Journal of the Korean Dietetic Association
    • /
    • v.18 no.2
    • /
    • pp.115-125
    • /
    • 2012
  • This study was conducted to investigate the effects of food consumption monitoring using a camera-phone in a weight control program. Twenty-six female college students (>30% body fat) were randomly assigned to the camera-phone and diary (CD) group or diary (D) only group. During the 8-week weight control program, the CD group controlled their food consumption using a camera-phone, in which they took a food picture and uploaded it to the homepage. However, the D group used only a diary to record their food intake. The mean energy intake of the CD group during the program was 1451.9 kcal while that of the D group was 1524.3 kcal. The total energy intakes of both groups significantly decreased during the program. The CD group lost 5.2 kg of body weight and 3.1% body fat while the D group lost 2.2 kg of body weight and 1.1% body fat. The body weight and fat levels significantly decreased in the CD group compared to the D group. The triglyceride, total-cholesterol and LDL-cholesterol levels of the CD group as well as the total-cholesterol level of the D group significantly decreased during the program. The total-cholesterol and LDL-cholesterol levels both significantly decreased in the CD group compared to the D group. In this study, it was concluded that digital photography method using a camera-phone might influence weight control through trained consumption monitoring, which helps individuals reduce discrepancies between perceived and actual consumption levels.

China's Fossil Fuel Market and IGCC (중국의 석탄 에너지 시장과 IGCC)

  • Zhang, Yanping;Ku, Jayeol;Um, Shingyoung;Kim, Suduk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.137.2-137.2
    • /
    • 2010
  • With current real economic growth of more than 10% per year, the Chinese energy consumption is rapidly increasing. Coal supply consists of the vast majority of China's total energy consumption requirements in 2008. China, the largest energy consumer, is expected to be heavily dependent on coal for future power generation, too (IEA,2009). A growing concern on global warming, on the other hand, drives Chinese government to declare her commitment to the reduction of CO2 emission by 2020. In this paper, China's energy market is examined for the current and future primary energy mix. Coal is found to be the biggest part accounting for 68.7% of total primary energy consumption while coal-fired power accounts for over 80% of the total power generation. The importance of Clean Coal Technology is being discussed based on the findings of the importance of coal in China's economy and its sustainable development. Among the technologies involved, a brief investigation of IGCC(Integrated Gasification Combined Cycle) technology with a review on current IGCC projects in China are provided from the perspective of environmental benefits. Studies on regional Chinese power market is also conducted. It is found that the regulated power tariff in electricity system makes the power suppliers suffer from financial loss and changes in the electricity price system is under serious consideration by Chinese government. Even though Chinese power market system causes difficulties of commercialization for IGCC technology, the potential benefits will be high due to China's huge requirements of power generating capacity and its heavy reliance on coal if the electricity price system can be changed smoothly.

  • PDF