A Study on the Concentration and Characteristics of Methicillin-resistant Staphylococci in the Indoor Air of Childcare Facilities (일부 어린이집의 실내공기 중 메치실린내성 포도알균의 오염 실태 및 특성)

  • Kim, Jong Oh;Kim, Young Jin
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.447-455
    • /
    • 2013
  • Objectives: This study aims to understand the concentration, diversity, and antibiotic characteristics of staphylococci present in the indoor air of child-care facilities. Methods: Air sampling was performed from October 2012 to January 2013 in 120 child-care facilities in Seoul, Korea. Methicillin-resistant bacteria were selected from the total obtained airborne bacteria and subjected to 16S rRNA analysis for methicillin-resistant staphylococcal species determination. Identified staphylococcal strains were tested for resistance to a range of antibiotics. Results: Average total airborne bacterial concentration was $508.9{\pm}246.3CFU/m^3$. Indoor concentration of total airborne bacteria had a significant positive correlation with the $CO_2$ concentration in the child-care facilities. Methicillin-resistant staphylococci were present in 13.3% of the child-care facilities studied. A total of four species (S. epidermidis, S. cohnii, S. saprophyticus, S. sp.) and 55 strains were identified from the indoor air of the child-care facilities. Staphylococcus cohnii was the most common species (54.5%), followed by S. epidermidis (38.2%). All of the isolated staphylococcal strains exhibited high resistance to oxacillin, erythromycin, mupirocin, and ceftizoxime. Especially, S. saprophyticus strains showed more multidrug resistance to oxacillin, vancomycin, clindamycin, erythromycin, lincomycin, ceftizoxime, mupirocin, and tetracycline than did other species. Conclusion: The results of this study showed that a monitoring system for multidrug-resistant bacteria is needed in facilities for children, as the community-associated infections of these bacteria are increasing.

A Study on Airborne Microorganisms in Hospitals in Seoul, Korea (서울시 일부 종합병원의 공기 중 미생물 농도 분포)

  • Song, Ju-Hee;Min, Jin-Young;Jo, Kyung-A;Yoon, Young-Hee;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.104-114
    • /
    • 2007
  • This study evaluated the airborne concentrations of bacteria, Gram-negative bacteria, and fungi in waiting rooms, wards, and outdoors, according to time and particle size between October 17 and November 28, 2003. The geometric mean number of airborne bacteria was highest in the morning. The more people there were, the higher was the total bacteria concentration. The concentration of fungi was also highest in the morning. Temperature and relative humidity affected the concentrations of fungi significantly (p<0.05). This study found relationships between microorganism concentrations and (actors such as time, place, temperature, humidity, ventilation, and number of people. Therefore, to manage the pollution resulting from airborne microorganisms, each time, place, and environmental factor should be examined periodically, and the number, size, and movement of airborne microorganisms should be evaluated.

Levels of Bioaerosols in Cattle Sheds and Nearby Farmers' Houses in Korea

  • Kang, Jung-Hwan;Jo, Wan-Kuen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E1
    • /
    • pp.1-9
    • /
    • 2007
  • In Korea, there is only a limited amount of information currently available on the levels of airborne bacteria and fungi of cattle sheds, although certain portions of people are potentially exposed to these bioaerosols in cattle sheds. Accordingly, the current study measured them inside cattle sheds, inside and outside farmers' houses near the sheds, and/or inside residential houses far away from the sheds during winter, 2004 and summer, 2005. The airborne bacteria and fungi were detected in most samples in the cattle farmers' houses as well as in the cattle sheds. Aspergillus, Cladosporium, and Penicillium, which have been associated with adverse health effects, were three most prevalent fungal genera, and they took most of the total fungi (more than 69%). The microbial concentrations measured inside the cattle sheds were comparable to those in other reports. Nevertheless, the present arithmetic and geometric mean (GM) microbial concentrations exceeded the Korean guideline for total airborne bacteria at medical facilities ($800\;CFU\;m^{-3}$), the current GM residential indoor concentrations at houses, and the residential indoor levels reported in other countries. The present findings suggest the need for a strategy to reduce Korean cattle farmers' exposure to these microorganisms. In contrast to the microbes, it is suggested that the cattle shed is not an important microenvironment for $PM_{10}$ exposure. Two characteristics examined in this study (seasonal variation and summer survey period, i.e., temperature and humidity) were all important for the cattle farmers' occupational exposure to airborne microbes. The lack of constancy between highest and lowest concentrations of bioaerosols over the survey period further suggests the necessity of performing a long-term survey to better examine farmer exposure levels and their variability.

Characteristics of Bioaerosol Generation of Household Humidifiers by User Practices (가정용 가습기의 사용자 습관에 따른 실내공기 중 바이오에어로졸의 발생특성)

  • Kim, Ik-Hyeon;Kim, Ki Youn;Kim, Daekeun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.503-509
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate the generation characteristics of airborne bacteria and fungi while operating a household humidifier, in consideration of user habits. Methods: Microbial samples were collected in a closed chamber with a total volume of 2.76 $m^3$, in which a humidifier was operated according to experimental strategies. A cultivation method based on the viable counts of mesophilic heterotrophic bacteria and fungi was performed. Experimental strategies were divided into three classes: the type of water in the water reservoir (tap water, cooled boiled water); the frequency of filling the reservoir (refill every day, no refill); and the sterilization method (sterilization function mode, humidifier disinfectants). Results: Significant increases in the concentration of airborne bacteria were observed while the humidifier was in operation. The concentration had increased to 2,407 $CFU/m^3$ by 120 hours when tap water filled the reservoir without any application of sterilization, while for cooled boiled water, it was merely 393 $CFU/m^3$ at a similar time point. Usages of disinfectant in the water tank were more effective in decreasing bioaerosol generation compared to sterilization function mode operation. Generation characteristics of airborne fungi were similar to those of bacteria, but the levels were not significant in all experiments. Calculated exposure factor can be used as an indicator to compare biorisk exposure. Conclusion: This study identified the potential for bioaerosol generation in indoor environments while operating a household humidifier. User practices were critical in the generation of bioaerosol, or more specifically, airborne bacteria. Proper usage of a humidifier ensures that any biorisks resulting from generated bioaerosol can be prevented.

Exposure Assessment for Airborne Biological Agents in Sawmills (제재업의 생물학적인자 노출실태 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Lee, In-Seop
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.274-281
    • /
    • 2010
  • The objectives of this study are (a) to investigate the distribution patterns and exposure concentrations of biological agents in sawmill industries and (b) to compare sampling methods of biological agents. The representative processes of 5 sawmills were selected to measure total airborne bacteria, fungi, endotoxin as well as dust. Airborne bacteria and fungi were measured with one stage impactor, six stage impactor and gelatin filteration methods. Endotoxin was collected with polycarbonate filters and analysed by kinetic chromogenic Limulus Amebocyte Lysate method. Geometric mean levels of airborne bacteria, fungi, endotoxin and dust were 1,864 CFU/$m^3$, 2,252 CFU/$m^3$, 31.5 EU/$m^3$ and 2.4 mg/$m^3$. The ratios of indoor/outdoor concentrations were 3.7 for bacteria, 4.1 for fungi, 3.3 for endotoxin and 9.7 for dust. The respiratory fractions of bacteria were 68.0, 50.9, 49.2 and 45.1% in band-saw, table-saw, rip-saw process and outdoor air. The respiratory fractions of fungi were 78.7, 90.8, 87.5 and 84.8% in band-saw, table-saw, rip-saw process and outdoor air, respectively. There was no significant differences in bacterial concentrations among single stage, six stage impaction and filteration methods. But, fungal concentrations measured with filtration methods were significantly higher than those with impaction methods. Geometric mean levels of airborne bacteria and fungi were higher than the OSHA guideline values of 1,000 CFU/$m^3$. The respiratory fractions of fungi were above 75%. The concentrations of biological agents were significantly different among culture-based sampling methods. In the exposure assessments of biological agents, further studies are needed for the comparisons of diverse sampling methods and the investigations of environmental factors.

Analysis of Variation in Total Airborne Bacteria Concentration to Assess the Performance of Biological Safety Cabinets in Microbial Laboratories

  • Hwang, Sung Ho;Park, Hyun Hee;Yoon, Chung Sik
    • Safety and Health at Work
    • /
    • v.5 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • Background: The purpose of this study was to compare the concentration of total airborne bacteria (TAB) in biosafety cabinets (BSCs) at universities and hospital microbial laboratories to assess the performance of BSCs. Methods: TAB was determined by using the single-stage Anderson sampler (BioStage Viable Cascade Impactor). The samples were obtained three times (with the BSC turned off and the shield open; with the BSC turned off and the shield closed; and with the BSC tuned on and operating) from the areas in front of 11 BSCs. Results: TAB concentrations of accredited and nonaccredited BSCs were determined. No significant differences were observed in the TAB concentrations of the accredited BSCs and the nonaccredited BSCs for the areas outside the BSCs in the laboratories (p > 0.05). TAB concentrations for the BSCs sampled with the shield open and the instrument turned off showed differences based on the sampling site outside the BSC in each laboratory. Conclusion: These results imply that TAB concentration is not altered by the performance of the BSCs or TAB itself and/or concentration of TAB outside the BSC is not a good index of BSC performance.

Assessment of Airborne Bacteria and Particulate Matters Distributed in Seoul Metropolitan Subway Stations (서울시 일부 지하철역 내 분포하는 부유 세균 및 입자상 오염물질 평가)

  • Kim, Ki-Youn;Park, Jae-Beom;Kim, Chi-Nyon;Lee, Kyung-Jong
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.254-261
    • /
    • 2006
  • In activity areas of subway workers and passengers in Seoul metropolitan subway lines 1-4, mein concentrations of airborne bacteria were relatively higher in workers' bedroom and station precinct whereas concentrations of particulate matters, $PM_{10}$ and $PM_{2.5}$, were relatively higher in platform, inside train and driver's seat as compared with other activity areas. This result indicates that little correlation between airborne bacteria and particulate matters was found, which assumed that most airborne particulate matters distributed in subway consisted of mainly inorganic dust like a metal particles. Mean concentrations of $PM_{10}$ and $PM_{2.5}$ in station precinct and platform exceeded the threshold limit value ($PM_{10}:150{\mu}g/m^3,\;PM_{2.5}:65{\mu}g/m^3$) but those in station office and ticket office were below it. The genera identified in all the activity areas of subway over 5% detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium, of which Staphylococcus and Micrococcus covered over 50% of total airborne bacteria and were considered as predominant genera distributed in subway.

Distribution of Airborne Microorganisms in Yellow Sands of Korea

  • Choi, Dae-Sung;Park, Yong-Keun;Oh, Sang-Kon;Yoon, Hee-Ju;Kim, Jee-Cheon;Seo, Won-Jun;Cha, Seung-Hee
    • Journal of Microbiology
    • /
    • v.35 no.1
    • /
    • pp.1-9
    • /
    • 1997
  • Distribution of airborne microorganisms was determined with two different types of air samplers, the Anderson cascade sampler and the Aerobioscope sampler, in the vicinity of Taejon. The size distribution of particles carrying bacteria and fungi was concurrently measured. The concentration of detected viable airborne particles was greatly varied. It was observed that the number of microbial particles increased in April and October. The most isze o particles carrying bacteria was larger than 4.7 .mu.m in mean aerodiameter, which made up 69.8% of the total particle fraction. About 63.2% of fungi-carrying particles were smaller than 4.7 .mu.m in aerodiameter. The distribution of particles on Yellow Sand Phenomena days was also analyzed. The number of fine particles having mass median aero-diameter from 1.0 to 10.mu.m increased on Yellow Sand Phenomena days to about 6 times that on normal days and the n umber of colony forming unit (CFU/$\textrm{m}^3$) of airborne bacteria also increased by 4.3 times in April. The reuslts from the Anderson sampler showed that the concentration of bacteria increased greatly on the fraction of fine particles ranging from 0.6 $\mu$m to 4.7 $\mu$m in diameter. Unlike the increase in bacterial floraon Yellow Sand Phenomena days, the fungal concentration slightly decreased and showed a normal size distribution parttern. This study suggests that a long-range transmission of bacteria results form bacteria adsorbing onto the fine particles during the Yellow Sand Phenomena.

  • PDF

Evaluation of Environmental Circumstance Within Swine and Chicken Houses in South Korea for the Production of Safe and Hygienic Animal Food Products (일부지역 양돈장 및 양계장 공기중 박테리아, 진균, 내독소 농도)

  • Kim, Young-Hwan;Suh, Hyung-Joo;Kim, Jin-Man;Jung, Yeon-Hoon;Moon, Kyong-Whan
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.623-628
    • /
    • 2008
  • This study was undertaken to determine the concentrations of airborne bacteria, fungi, particles, and endotoxin in swine and chicken houses. Six swine buildings and seven chicken houses were randomly selected in southern Gyonggi Province, South Korea. The geometric mean concentrations of airborne bacteria in swine and chicken houses were $2.7{\times}10^5\;CFU/m^3$ and $5.6{\times}10^7\;CFU/m^3$, respectively. The airborne bacteria concentrations in chicken houses were significantly higher than those of swine houses (p<0.05). The geometric mean concentration of airborne fungi in swine houses was $4.9{\times}10^3\;CFU/m^3$, which was higher than the value of $2.1{\times}10^3\;CFU/m^3$ found in chicken houses. The mean concentrations of airborne particles and endotoxin in swine houses were $3.48\;mg/m^3$ and $943.1\;EU/m^3$, and they were $15.43\;mg/m^3$ and $1,430.5\;EU/m^3$ in chicken houses, respectively. A significant difference between swine and chicken houses was found for total dust (p<0.05), but not for endotoxin. In this study, the concentrations of endotoxin in both swine and chicken houses as well as particles in chicken houses were high, and in about 50% of the samples exceeded the worker health safety levels of $614\;EU/m^3$ suggested in previous studies. These results may indicate a considerable respiratory hazard for workers in these environments.

Assessment of Indoor and Outdoor Air Quality through Determination of Microorganism (미생물을 이용한 일부 병원, 가정 및 일반 대기질의 평가)

  • Ha, Kwon Cheol;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.73-81
    • /
    • 1991
  • To assess biological air quality, concentrations of viable airborne microbes were determined in hospital home and outdoor air from August 25 to October 18, 1990. Bacteria, fungi and thermophilic bacteria were sampled using gravitational and suctional sampling method. In bacteria groups, the Staphylococcus spp. was identified by microscopic examination and biochemical tests. Results of the study are as follows. 1. Results using the gravitational sampling method indicated that average numbers of airborne microbes in hospital home and outdoor air were 21.5, 12.2 and 17.6 CFU/plate, respectively. These levels are well within an appropriate standard of 50 CFU/plate suggested by Endo. 2. Results using the suctional sampling method indicated that total airborne microbe concentrations in hospital, home and outdoor air were 1,998, 1,363 and $1,880CFU/m^3$, respectively. All of the results were within the recommended remedial action level, $10,000CFU/m^3$ of the American Conference of Governmental Industrial Hygienists(ACGIH). 3. Concentration of thermophilic bacteria in hospital and outdoor air were 79 and $111CFU/m^3$, respectively. Thermophilic bacteria were not detected in the home air. These results were within the remedial action level, $500CFU/m^3$. 4. Concentrations of Gram negative bacilli in holpital home and outdoor air were 20.3, 23.6 and $16.8CFU/m^3$, respectively. all were within the remedial action level, $500CFU/m^3$, recommended by ACGIH. 5. Concentrations of Staphylococcus spp. in hospital, home and outdoor air were 34.8, 14.7, and $22.4CFU/m^3$. respectively. all were within the remedial action level, $75CFU/m^3$, recommended by ACGIH. The percentages of Staphylococcus spp. in total bacteria in hospital, home and outdoor air were 19.0, 10.2 and 14.5%, respectively.