커브피팅 알고리즘이 적용된 토크 정밀 측정 시스템 개발에 관한 연구 (Study on Torque precision measuring System using Curve Fitting Algorithm)

  • 이기원;하재승;강승수
    • 디지털산업정보학회논문지
    • /
    • 제8권4호
    • /
    • pp.1-11
    • /
    • 2012
  • This paper is the study on the development of a torque precision measuring system using the curve fitting algorithm. This system can be divided into the hardware part and the software part. The hardware part consists of the main base board, the DAQ(Data Aquisition) board and Calibration parts. The software part consists of the software filter module and the curve fitting algorithm module. We have tested the torque transducer including the strain gauge for 200 Nm range and have analyzed the data acquired with the curve fitting algorithm by using this system. The DAQ board converts the electric signal induced by the transducer to the digital value precisely by using the shunt calibration procedure. The main board including the curve fitting algorithm calculates the exact digital torque value by using the digital value from the DAQ board. In this study, we confirmed that the result of the appropriate high-order power-series polynomial function is more accurate than the result of the low-order power-series polynomial through the system.

와전류 동력계에서 계자전류를 이용한 부하토크의 측정에 관한 연구 (A Study on the Measurement of Load Torque by the Field Coil Current in an Eddy Current Dynamometer)

  • 문병수;이응석;이형석
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.84-92
    • /
    • 2001
  • Commercial eddy current dynamometers control the torque of rotating body, power supply machine, with the field coil current being operated as a braking force. In this paper, we studied the relation between field coil current and torque load of eddy current dynamometer. By the torque measuring analysis of eddy current dynamometer it is linear relation between the brake force measured from a torque meter which is installed at the case of dynamometer and the multiplied shaft rpm by the squares of field coil current (N$\times$I$^2$). To prove the relation, it was experimented and showed that the torque operated by the rotating body can be measured with the shaft rpm and the field coil current of the eddy current dynamometer. This result shows a possibility that eddy current dynamometer can measure the torque of rotating body without a torque measuring device. such as load cell.

  • PDF

계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정 (The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory)

  • 무루게타;김민석;박연규;이호영
    • 한국정밀공학회지
    • /
    • 제32권2호
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

인버터 시험을 위한 부하제어 장치 (Load Control Device for VVVF Inverter Testing)

  • 김길동;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.675-679
    • /
    • 2007
  • The control method of programmable dynamometer for overall test of machine is to load reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for moter torque of programmable dynamometer. Therefore, this kind of system could not perform dynamic and nonlinear load. In this paper, the control method using the load torque observer without a measure for torque transducer is proposed. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

견인구동시스템 시험을 위한 개선된 프로그램어블 다이나모메터 제어 (Improved Programmable-Dynamometer Control For Traction Drive System Testing)

  • 김길동;홍재성;신정렬;이우동;한석윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.427-432
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of moter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction meter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

전동기 시험을 위한 프로그램어블 다이나오메터 제어 (Programmable-Dynamometer Control For Traction Motor Testing)

  • 김길동;홍재성;안태기;이호용;신종렬;한석윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1108-1110
    • /
    • 2003
  • The control method of programmable dynamometer for overall test of machine is to load the reference torque which is computed from torque transducer into motor under test. But the torque information detected from torque transducer have a lot of noise when the load torque of meter is a small quantity or changing. Thus, torque transducer must have a low pass filter to detect a definite torque information. But The torque delay generated by filter with torque transducer occur a torque trouble for meter torque of programmable dynamometer. The proposed system improved the problem of the torque measuring delay with torque transducer, and the load torque is estimated by the minimal order state observer based on the torque component of the vector control induction moter. Therefore, the torque controller is not affected by a load torque disturbance.

  • PDF

유도형 적산전력량계의 토오크측정 기술 (Torque measuring technique of induction watthour meter)

  • 박영태;강정홍;장석명;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.290-292
    • /
    • 1998
  • The driving torque acting on a rotatable disk of watthour meter is proportional to the effective power. The aim of this paper is to show how the driving torque on a disk can be measured by a LVDT transducer. This driving torque is obtained by the theoretical computation. To verify the computated result, the LVDT as torque transducer, was used. A comparison is made between computed and measured torques.

  • PDF

CALIBRATION OF A NEW CAPACITIVE TORQUE SENSOR FOR MEASURING BASIC MAGNETIC CHARACTERISTICS WITH ELECTROMAGNETIC AND GRAVITATIONAL FORCES

  • Kim, M.Y.;Choi, K.L.;Choi, S.J.;Song, E.Y.;Lee, Y.H.;Hee, J.R.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.786-789
    • /
    • 1995
  • With a newly designed capacitive torque sensor a multipurpose magnetometer for measuring basic magnetic characteristics such as hyteresis loops, magnetic anisotropy and magnetostriction was built. In order to calibrate the capacitive torque sensor, we measured the output voltages of the sensor by applying the torques due to the electromagnetic and gravitational forces. Experimental results of the several calibration method for the capacitive torque sensor showed good agreement within 3 %.

  • PDF

일축 이방성 자성체의 M-H 이력 곡선 측정의 새방법 (A New Method for Measuring M-H Hysteteresis Loop of a Uniaxially Anisotropic Magnetic Material)

  • 허진;신성철
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.900-904
    • /
    • 1995
  • 돌림힘 자력계를 이용하여 일축 이방성 자성체의 M-H 이력 곡선을 측정하는 새방법을 개발하였다. 본 방법에 의한 M-H 이력 곡선으로부터 포화 및 잔류 자기화량과 보자력을 얻을 수 있었다. 본 방법의 정확도는 자기회사 비균질한 보자력 근처의 인가 자기 마당에서도 영향받지 않았다. $2{\times}10^{-3}$ dyn cm의 측정 감도를 갖는 돌림힘 자력계를 이용한 자기화량 측정에서 $10^{-6}$ emu 이상의 고감도를 얻었다.

  • PDF

Comparison of the torque stability of Implant Torque Controllers

  • Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Korean Dental Science
    • /
    • 제2권1호
    • /
    • pp.19-27
    • /
    • 2009
  • Tightening of the screws in implant restorations should be accurate and precise. If applied torque is too low, screw loosening would be occurred. With too high torque, the screw fracture might take place. Various torque generating devices are developed and employed to apply a proper torque. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; electronic torque controller, torque limiting device, torque indicating device and contra angle torque driver. Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were done with each torque controller. All implant torque controllers have shown slight errors and deviations. The torque liming device exhibited the most accurate data. No significant difference was found among the mean de-torque values of the electronic torque controller, torque indicating device and contra angle torque driver. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

  • PDF