• Title/Summary/Keyword: Top Scan 3D

Search Result 19, Processing Time 0.023 seconds

Comparative Assessment of Virtual Garments using Direct and Manual Avatars (가상아바타에 따른 가상의복의 비교평가)

  • Lim, Ho-Sun;Istook, Cynthia L.
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1359-1371
    • /
    • 2011
  • The purpose of this paper is to compare two avatars made using direct and manual methods and to evaluate the fit and appearance of two virtual garments on the direct and manual avatars. In this study, two subjects were measured by $[TC]^2$ body scanner and the avatars and virtual garments were created by OptiTex software. The direct avatar was made by the direct importation of 3D body scan data and the manual avatar was made by manual input from extracted body measurement. Two virtual garments in a tank-top were evaluated by distance, transparency, and stretch maps. In the results of comparing difference of the direct and manual avatars, the bust and back of the manual avatar are protruded slightly more than that of the direct avatar and the manual avatar is slightly larger dimensions at the bust, waist, abdomen, and hip area in the side view in case of subject 1 and 2. In the results of comparing difference of the fit and appearance of two virtual garments on the direct and manual avatars, in case of subject 1 and 2, the back of the virtual garment on the manual avatar are protruded more than that of the direct avatar. Also, the ease in the bust area of the virtual garment on the manual avatar with a projected bust area was smaller than that of the virtual garment on the direct avatar and the stretch of that of the manual avatar was also high in the bust area. The results of this study are expected to be used as basic information in the apparel industry using virtual try-on technology.

Developing of Grading Method using 3D Body Measurement Data of Women in Their Thirties -Focusing on Their Proper Body Types-

  • Shin, Ju-young Annie;Nam, Yun-ja
    • Fashion & Textile Research Journal
    • /
    • v.19 no.6
    • /
    • pp.749-758
    • /
    • 2017
  • The purpose of the present study is to develop a grading deviation, which is appropriate for the body type of women in thirties, by analyzing the three-dimensional body type. The materials for the study were adopted from the body measurement data of women in the age group of 30 to 39 years old, provided from Size Korea. By reflecting the factor analysis results using the three-dimensional shape measurement, deviations were derived. First, six factors influencing the changes in human body shape were derived as waist-hip length factor, bust-waist shape factor, back protrusion back shoulder factor, bust length factor, shoulder length factor, and frontal waist dart factor. The bust size and height, which can be easily utilized for the top original grading, were used for deriving a regression formula, and the deviation was set in accordance with the result. Second, by applying the deviation which reflects the changes in the body shape, the crimps which were generated due to the application of existing deviation were remarkably reduced, indicating that the grading of the present study is more fitting than the existing one. The deviation derived by the analysis of actual increase and decrease of body size was more fitting than the existing one. This was proved by actual wearing experiment, which represents the significance of this study.

Digital technique in diagnosis and restoration of maxillary anterior implant: a case report (디지털 기법을 활용한 상악 전치부의 진단 및 수복 증례)

  • Haemin, Bang;Woohyung, Jang;Chan, Park;Kwi-Dug, Yun;Hyun-Pil, Lim;Sangwon, Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.249-256
    • /
    • 2022
  • The implant prosthesis of anterior maxilla requires careful consideration in planning. In order to satisfy both esthetic and functional needs of a patient, fusion of intra-oral scan in Cone-beam computed tomography (CBCT) and facial scan can be considered. Bony structures and soft tissues captured in CBCT and occlusal surfaces of intra oral scan were incorporated into personal characteristics from facial scan. The patient had insufficient buccal bone on maxillary anterior area. The maxillary implants could not be placed on the most ideal position. However, the "top down" approach completed by computer-generated arranging of teeth in implant planning and surgery with surgical guide resulted in esthetically and functionally satisfying result regardless of the limitation. Careful diagnosis with digital technique and the usage of surgical guide resulted in successful surgery and esthetic restoration. The temporary fixed prostheses were designed, restored and evaluated. The patient was not satisfied with the first design of temporary prosthesis, which showed uneven space distribution between teeth due to the position of maxillary implant. The design was modified by changing proximal emergence contours and line angle to alter the perceived since of incisors. The patient was satisfied with the new design of provisional restoration. A digital occlusion analyzer (Arcus Digma II, KaVo, Leutkirch, Germany) was used to measure inherent condylar guidance and anterior guidance of a patient to provide a definitive prosthesis.

A Comparative Study on Virtual Try-on Systems using Body Measurement Input

  • Lim, Ho-Sun;Istook, Cynthia
    • The International Journal of Costume Culture
    • /
    • v.13 no.2
    • /
    • pp.118-129
    • /
    • 2010
  • Digital technology introduced into the clothing and fashion industry is evolving to digital virtual fashions and consumer-centered mass-customized production systems. Today the application of such 3D virtual try-on systems is being expanded gradually in the clothing industry. This study purposed to make virtual avatars and virtual garments using OptiTex and V-stitcher virtual software and compared the appearance of the virtual garments put on the virtual avatars. For this, we created virtual avatars and virtual garments using body measurements obtained from jive subjects of top jive body shapes, respectively, using $[TC]^2$ body scanner. According to the results of comparing the outcomes of the two different virtual software systems, virtual avatar II of V-Stitcher tended to have a more round and lifted hip and the waist line at a higher position. In addition, the body curves and shapes of a virtual avatar affect the appearance of virtual garments. This study applied the same body measurements to virtual avatars and the same pattern to virtual garments, but when different kinds of virtual software were used, the virtual avatars and virtual garments showed different appearance and fit. This result may mean that when customers buy apparel products using different kinds of virtual try-on systems, their evaluation of appearance can vary depending on the virtual try-on system. Therefore, research needs to be made actively for the development and use of linkage programs that can reflect actual body measurements between virtual software systems and 3D body scanning systems.

  • PDF

The Evaluation of Accuracy for Airborne Laser Surveying via LiDAR System Calibration (시스템 초기화(Calibration)에 따른 항공레이저측량의 정확도 평가)

  • 이대희;위광재;김승용;김갑진;이재원
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.15-26
    • /
    • 2004
  • The calibration for systematic error in LiDAR is crucial for the accuracy of airborne laser scanning. The main error is the misalignment of platforms between INS(Inertial Navigation System) and Laser scanner For planimetrical calibration of LiDAR, the building is good feature which has great changes in height and continuous flat area in the top. The planimetry error(pitch, roll) is corrected by adjustment of height which is calculated from comparing ground control points(GCP) of building to laser scanning data. We can know scale correction of laser range by the comparison of LiDAR data and GCP is arranged at the end of scan angle where maximize the height error. The area for scale calibration have to be large flat and have almost same elevation. At 1000m for average flying height, The Accuracy of laser scanning data using LiDAR is within 110cm in height and ${\pm}$50cm in planmetry so we can use laser scanning data for generating 3D terrain surface, expecically digital surface model(DSM) which is difficult to measure by aerial photogrammetry in forest, coast, urban area of high buildings

  • PDF

Terrestrial LiDAR Measurements and Analysis of Topographical Changes on Malipo Beach (지상 LiDAR를 이용한 만리포 해변 정밀 지형측량 및 지형 변화 분석)

  • Shim, Jae-Seol;Kim, Jin-Ah;Park, Han-San;Kim, Seon-Jeong
    • Ocean and Polar Research
    • /
    • v.32 no.1
    • /
    • pp.73-84
    • /
    • 2010
  • A terrestrial LiDAR was used to acquire precise and high-resolution topographical information of Malipo beach, Korea. Terrestrial LiDAR and RTK-DGPS (VRS) were mounted on top of a survey vehicle and used to scan 20 times stop-and-go method with 250 m spacing intervals at ebb tides. In total, 7 measurements were made periodically from 2008 to 2009 and after each beach replenishment event. We carried out GIS-based 3D spatial analysis such as slope and volume calculations in order to assess topographical changes over time. In relation to beach replenishment, comparative analysis of each volume change revealed them to be similar. This result indicates that the terrestrial LiDAR measurements are accurate and can be used to analyze temporal topographical changes. In conclusion, the methodology employed in this study can be used efficiently to exercise coastal management through monitoring and analyzing beach process such as erosion and deposition.

DPSS UV laser projection ablation of 10μm-wide patterns in a buildup film using a dielectric mask (Dielectric 마스크 적용 UV 레이저 프로젝션 가공을 이용한 빌드업 필름 내 선폭 10μm급 패턴 가공 연구)

  • Sohn, Hyonkee;Park, Jong-Sig;Jeong, Su-Jeong;Shin, Dong-Sig;Choi, Jiyeon
    • Laser Solutions
    • /
    • v.16 no.3
    • /
    • pp.27-31
    • /
    • 2013
  • To engrave high-density circuit-line patterns in IC substrates, we applied a projection ablation technique in which a dielectric ($ZrO_2/SiO_2$) mask, a DPSS UV laser instead of an excimer laser, a refractive beam shaping optics and a galvo scanner are used. The line/space dimension of line patterns of the dielectric mask is $10{\mu}m/10{\mu}m$. Using a ${\pi}$ -shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam; and a telecentric f-${\theta}$ lens focuses it to a $115{\mu}m{\times}105{\mu}m$ flat-top beam on the mask. The galvo scanner before the f-${\theta}$ lens moves the beam across the scan area of $40mm{\times}40mm$. An 1:1 projection lens was used. Experiments showed that the widths of the engraved patterns in a buildup film ranges from $8.1{\mu}m$ to $10.2{\mu}m$ and the depths from $8.8{\mu}m$ to $11.7{\mu}m$. Results indicates that it is required to increase the projection ratio to enhance profiles of the engraved patterns.

  • PDF

Monte Carlo Simulation of Irradiation Treatment of Peaches (Prunus persica L. Batsch) (몬테카를로 시뮬레이션을 이용한 복숭아의 방사선 조사)

  • Kim, Jongsoon;Kim, Dong-Hyun;Park, Jong-Min;Choi, Won-Sik;Kwon, Soon Hong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.337-344
    • /
    • 2018
  • Food irradiation is important not only in ensuring safety but also improving antioxidant activity of peaches. Our objective was to establish the best irradiation treatment for peaches by calculating dose distribution using Monte Carlo simulation. 3-D geometry and component densities of peaches, extracted from CT scan, were entered into MCNP to obtain simulated dose distribution. Radiation energies for electron beam were 1.35 MeV (low energy) and 10 MeV (high energy). Co (1.25 MeV) and the Husman irradiator, containing three sealed Cs source rods in an annular array, were used for gamma irradiation. At 1.35 MeV electron beam simulation, electrons penetrated well beyond the peach skin, enough for surface treatment for microorganisms and allergens. At 10 MeV electron beam simulation, for top-beam only treatment, doses at the core were the highest and for double beam treatment, the electron energy was absorbed by the entire sample. At Co source, the radiation doses were presented on the whole area. At Cs source, the dose uniformity ratios were 2.78 for one source and 1.48 for three ones at 120 degrees interval. Proper control of irradiation treatment is critical to establish confidence in the irradiation process.

A Study on the 3D Measurement Data Application: The Detailed Restoration Modeling of Mireuksajiseoktap (미륵사지석탑 정밀복원모형 제작을 중심으로 한 3차원 실측데이터의 활용 연구)

  • Moon, Seang Hyen
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.2
    • /
    • pp.76-95
    • /
    • 2011
  • After dismantled, Mireuksajiseoktap(Stone pagoda of Mireuksa Templesite) is being in the stage of restoration design. Now, different ways - producing restoration model, a 3 dimension simulation - have been requested to make more detailed and clearer restoration design prior to confirmation of its restoration design and actual restoration carry-out. This thesis proposes the way to build the detailed model for better restoration plan using extensively-used Reverse Engineering technique and Rapid Prototyping. It also introduces each stage such as a 3-dimension actual measurement, building database, a 3-dimension simulation etc., to build a desirable model. On the top of that, this thesis reveals that after dismantled, MIruksaji stone pagoda's interior and exterior were not constructed into pieces but wholeness, so that its looks can be grasped in more virtually and clearly. Secondly, this thesis makes a 3-dimension study on the 2-dimension design possible by acquiring basic materials about a 3-dimension design. Thirdly, the individual feature of each member like the change of member location can be comprehended, considering comparing analysis and joint condition of member. Lastly, in the structural perspective this thesis can be used as reference materials for structure reinforcement design by grasping destructed aspects of stone pagoda and weak points of the structure. In dismantlement-repair and restoration work of cultural properties that require delicate attention and exactness, there may be evitable errors on time and space in building reinforcement and restoration design based on a 2-dimension plan. Especially, the more complicate and bigger the subject is, the more difficult an analysis about the status quo and its delicate design are. A series of pre-review, based on the 3-dimension data according to actual measurement, can be one of the effective way to minimize the possibility that errors about time - space happen by building more delicate plan and resolving difficulties.