• 제목/요약/키워드: Top Event

검색결과 175건 처리시간 0.023초

FT의 빠른 신뢰도계산을 위한 연구 (A Study on the rapid calculating of reliability for Fault Tree)

  • 이일재;이광원
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.180-190
    • /
    • 1997
  • A new method in the fault tree analysis (FTA) for the reliability calculation is suggested. Two steps are necessary in traditional method in evaluation of the occurrence probability of top event in fault tree (FT). The first step is to find the minimal outsets, and the second one is to substitute the result into the poincare equation. In order to reduce the enormous computing time of this method, lots of rapid algorithms have been developed. Almost of all achievements were, however, based on the partial structural properties of FT. In this paper, the FT is transformed to a non-linear graph G which has the same minimal outsets of original n, and then the reliability is calculated using the domination theory. In this new method, the required number of equation terms are at most $2^n$ (n is node number of graph G), while $2^m$-1 (m is the number of minimal cutsets) calculation terms are required in the poincare equation in traditional method. Since m>>n in general. our new method reduces the calculation time significantly.

  • PDF

Fuzzy Sets을 이용한 시스템 부품의 고장가능성 진단에 관한 모델 (The possibility of failure of system component by fuzzy sets)

  • 김길동;조암
    • 품질경영학회지
    • /
    • 제20권2호
    • /
    • pp.44-54
    • /
    • 1992
  • In conventional fault-tree analysis, the failure probabilities of components of a system are treated as exact values in estimating the failure probability of the top event. For the plant layout and systems of the products, however, it is often difficult to evaluate the failure probabilities of components from past occurences, because the environments of the systems change. Furthermore, it might be necessary to consider possible failure of components of the systems even if they have never failed before. In the paper, instead of the probability of failure, we propose the possibility of failure, viz, a fuzzy set defined in probability space. Thus, in this paper based on a fuzzy fault-tree model, the maximum possibility of system failure is determined from the possibility of failure of each component within the system according to the extension principle.

  • PDF

LQG design scheme for multiple vibration controllers in a data center facility

  • Kohiyama, Masayuki;Yoshida, Minako
    • Earthquakes and Structures
    • /
    • 제6권3호
    • /
    • pp.281-300
    • /
    • 2014
  • This study proposes a scheme to design control parameters for a data center facility with a vibration controller on its top floor and a secondary isolation device with its own vibration controller designed to protect vibration-sensitive computer equipment. The aim is to reduce the effects of acceleration and drift from an earthquake on computer servers placed on the isolation device that must operate during a seismic event. A linear elastic model is constructed and the evaluation function of the linear quadratic Gaussian (LQG) control is formulated. The relationship between the control parameters and the responses is examined, and based on the observations, a control parameter design scheme is constructed to reduce the responses of both the building and the computer server effectively.

노냉각수 제어계통의 신뢰도해석에 관한연구 (A Reliability Analysis of CVCS)

  • Chung Chan Lee;Byung Soo Lee;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • 제15권1호
    • /
    • pp.11-22
    • /
    • 1983
  • 가압 경수로의 노 냉각수 제어계통의 신뢰도를 해석하였다. 이 신뢰도 해석에서 붕소주입실패를 상위사고로 설정하였다. 신뢰도 해석은 고장계통도를 작성한 후 이 고장 계통도로부터 최소절군을 구하였다. 붕소주입실패에 의한 노 냉각수 제어계통의 불가용성은 1.497$\times$$10^{-5}$으로 계산되었다. 노 냉각수 제어계통의 불가용성에 가장 중요한 영향을 미치는 것은 붕산전달펄프의 신뢰도이며, 인간의 실수 역시 계통 신뢰도에 중요한 인자임이 나타났다.

  • PDF

Development of STI/AOT Optimization Methodology and an Application to the AFWPs with Adverse Effects

  • You, Young-Woo;Yang, Hui-Chang;Chung, Chang-Hyun;Moosung Jae
    • Nuclear Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.211-217
    • /
    • 1997
  • Adverse effects caused by the surveillance test for the components of nuclear power plant involve plant transients, unnecessary wear, burden on licensee's time, and the radiation exposure to personnel along with the characteristics of each component. The optimization methodology of STI and AOT has been developed and applied to AFWPs of a reference plant. The approach proposed in this paper consist of the resole in minimal mean unavailability of the two-out-of-four system with adverse effects are analytically calculated for the example system. The surveillance testing strategy are given by the sequential test, the staggered test and the train staggered test which is a mined test scheme. In the system level, the sensitivity analyses for the STI and AOT, are performed for the measure of the system unavailability of the top event in the fault tree developed for the example system. This methodology may contribute to establishing the basis for the risk-based regulations.

  • PDF

Design of Self-Timed Standard Library and Interface Circuit

  • Jung, Hwi-Sung;Lee, Moon-Key
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.379-382
    • /
    • 2000
  • We designed a self-timed interface circuit for efficient communication in IP (Intellectual Property)-based system with high-speed self-timed FIFO and a set of self-timed event logic library with 0.25um CMOS technology. Optimized self-timed standard cell layouts and Verilog models are generated for top-down design methodology. A method for mitigating a design bottleneck when it comes to tolerate clock skew is described. With clock control method and FIFO, we implemented high-speed 32bit-interface chip for self-timed system, which generated maximum system clock is 2.2GHz. The size of the core is about 1.1mm x 1.1mm.

  • PDF

원전의 부분충수운전에 대한 동적 신뢰도평가 (A New Method for Assessing Dynamic Reliability for the Mid-loop Operation)

  • 제무성;박군철
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.52-59
    • /
    • 1996
  • This paper presents a new approach for assessing the dynamic reliability in a complex system such as a nuclear power plant. The method is applied to a dynamic analysis of the potential accident sequences which may occur during mid-loop operation. Mid-loop operation is defined as an operation to make RCS water level below the top of the flow area of the hot legs at the junction with the reactor vessel for repairs and maintenance of steam generators and reactor coolant pumps for a specific time. The Idea behind this approach consists of both the use of the concept of the performance achievement/requirement correlation and of a dynamic event tree generation method. The assessment of the system reliability depends on the determination of both the required performance distribution and the achieved performance distribution. The quantified correlation between requirement and achievement represents a comparison between two competing variables. It is demonstrated that this method is easily applicable and flexible in that it can be applied to any kind of dynamic reliability problem.

  • PDF

IPA기법을 활용한 성 평등적 스포츠 이벤트로서 연고전의 개선방안 (A study on improvement plan of Yon-Ko-Jeon as a gender equality sports event using the IPA)

  • 배재윤;원영신
    • 한국체육학회지인문사회과학편
    • /
    • 제55권5호
    • /
    • pp.447-457
    • /
    • 2016
  • 본 연구의 목적은 연고전의 여성 소외현상에 관한 여학생 인식실태를 확인하고, IPA(Importance Performance Analysis)기법을 통해 성 평등적 스포츠 이벤트로서 연고전의 개선방안을 모색하는 데 있다. 이를 위해 연세대학교와 고려대학교에 재학 중인 2, 3, 4학년 여학생 대상으로 설문조사 후 322부를 분석하였다. 이들을 대상으로 분석한 연구의 결과는 다음과 같다. 첫째, 두 대학의 대다수 여학생은 연고전에 여성 스포츠와 여성 선수가 부재한 사실을 인식하지 못하고 있었다. 이들은 연고전의 여성 소외현상에 대해 심각하게 여기지 않았으며, 개선의 필요성 또한 절실하지 않은 것으로 나타났다. 이는 일상을 잠식한 젠더스포츠의 전형적인 사례로 볼 수 있다. 둘째, IPA 분석 결과, 성 평등적 스포츠 이벤트로서 연고전의 개선방안은 구성원 공유가치 반영성을 강화하고 여성 동아리스포츠를 도입하는 것이 필요한 것으로 나타났다. 현재 연고전에는 구성원이 공유하는 가치가 제대로 반영되지 않고 있으므로 이에 대한 개선이 필요한 것이다. 또한, 연고전에 여성 동아리 스포츠 대항전을 도입해야 할 것으로 나타났다. 위 두 가지 속성은 연고전을 성 평등적 스포츠 이벤트로 개선하기 위하여 먼저 고려해야 할 사항들로 확인되었다.

베이지안 네트워크를 이용한 지진 유발 화재・폭발 복합재해 확률론적 안전성 평가 (Bayesian Network-based Probabilistic Safety Assessment for Multi-Hazard of Earthquake-Induced Fire and Explosion)

  • 이세혁;석의찬;송준호
    • 한국전산구조공학회논문집
    • /
    • 제37권3호
    • /
    • pp.205-216
    • /
    • 2024
  • 최근 원자력 지진 PSA(Probabilistic Safety Assessment)를 토대로 산업시설물의 지진 PSA를 수행하는 연구가 진행되었다. 해당 연구는 원자력 발전소와 산업시설물의 차이를 파악하고, 최종적으로 운영정지를 목표로 하는 고장수목(Fault Tree)를 구축한 후 시각적 확률도구인 베이지안 네트워크(Bayesian Network, BN)으로 변환하였다. 본 연구는 선행연구를 기반으로 지진으로 유발된 구조손상으로 인해 발생 가능한 화재・폭발에 대해 PSA를 수행하고자 하였다. 이를 위해 화재・폭발을 사건수목(Event Tree)으로 표현하고, BN으로 변환하였다. 변환된 BN은 화재・폭발 모듈로서 선행연구에서 제시된 고장수목 기반 BN과 연계되어 최종적으로 지진 유발 화재・폭발 PSA를 수행할 수 있는 BN 기반 방법론이 개발되었다. 개발된 BN을 검증하기위해 수치예제로서 가상의 가스플랜트 Plot Plan을 생성하였고, 가스플랜트의 설비 종류가 구체적으로 반영된 대규모 BN을 구축하였다. 해당 BN을 이용하여 지진 규모에 따른 전체시스템의 운영정지 확률 및 하위시스템들의 고장확률 산정과 더불어 역으로 전체시스템이 운영 정지되었을 때 하위시스템들의 영향도 분석과 화재・폭발 가능성을 산정하여 다양한 의사결정을 수행할 수 있음을 제시함으로써 그 우수성을 확인하였다.

고창군 광승리 연안 퇴적층의 퇴적 시기와 범람 기원 특성 (Burial Age and Flooding-origin Characteristics of Coastal Deposits at Gwangseungri, Gochanggun, Korea)

  • 김종연;양동윤;신원정
    • 한국지구과학회지
    • /
    • 제36권3호
    • /
    • pp.222-235
    • /
    • 2015
  • 고창군 광승리 지역의 해발고도 5 m 내외의 해안 지점(DH)과 해발고도 10-15 m의 단구 상부 지점(KS)에서 시료를 채취하여 화학 분석과 입도 분석 등을 통하여 퇴적 물질의 특성을 파악하였다. DH는 풍화된 기반암을 피복하는 적색 토양층으로 하부에서 상부로 가면서 물질 조성이 점진적으로 변화하였다. DH 시료 내에 점토광물이 포함되어 있는 것으로 나타났다. 이를 근거로 하여 이 층을 제자리 풍화층으로 판단하였다. KS의 경우 구릉의 말단부에 위치하는 자갈층을 피복하는 층으로 물질 조성이 전반적으로 DH 부분과 상당히 다른 것으로 나타났으며, 일부 구간에서 물질의 교란이 일어나거나 외부 물질의 유입이 있었던 것으로 추정되었다. 한편 입자의 입도에 있어서 KS 시료들은 현재의 해빈 물질과 다른 특성이 나타난다. KS의 하부는 해빈에 비하여 세립 물질로 나타났으며, 중간 부분은 해빈보다 조립 물질이다. KS 시료의 분급은 해빈에 비하여 나쁜 것으로 나타났으며, 이 퇴적층중 일부는 지속적인 파랑과 조류에 의한 것보다는 일시적인 고에너지 환경에서 퇴적된 것으로 추정된다. 한편 KS 부분 시료의 매몰 연대는 광여기루미네센스(OSL) 분석에 의하여 0.65-0.71 ka로 추정되었다. 추가적인 연구를 통해 해당 퇴적층과 형성 과정의 특성에 대해서는 명확히 밝혀져야 할 것이지만, 해당 퇴적층은 폭풍에 의한 연안 범람 퇴적층일 가능성이 높은 것으로 추정된다.