• Title/Summary/Keyword: Tooth model

Search Result 571, Processing Time 0.026 seconds

A Study on Dynamic Characteristics of Gear-System (기어-시스템의 동특성에 대한 연구)

  • Lee, Hyoung-Woo;Park, No-Gill
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.111-117
    • /
    • 2005
  • The vibration problems associated with gear coupled rotors have been the focus of much engineering work. These systems are complex and difficult to analyze in that they have the problems associated with conventional rotors plus those additional problems associated with the gear couplings. This paper examines the problems peculiar to the gear mesh. Because of the meshing action of gears, the elasticity of the gear teeth introduces time-varying stiffness coefficients into the governing equations of motion. This means that system response must be thought of in terms of Mathieu-type equations, where multiple-frequency response occur due to the periodic coefficients. The meshing action of the gears also couples the lateral and torsional gear motions. Gear errors, such as tooth profile and spacing errors, produce forces and torque that excite the system at multiple frequencies, some of which are much higher than shaft rotational speed. To investigate how to the time-varying stiffness in the gear teeth and the gear errors act one the dynamic response of the gear coupled rotors, a three-dimensional dynamic model with lateral-tortional oscillation is developed. The harmonic balance technique is employed to solve this mathieu-type problem.

A Study on Fault Detection and Diagnosis of Gear Damages - A Comparison between Wavelet Transform Analysis and Kullback Discrimination Information - (기어의 이상검지 및 진단에 관한 연구 -Wavelet Transform해석과 KDI의 비교-)

  • Kim, Tae-Gu;Kim, Kwang-Il
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 2000
  • This paper presents the approach involving fault detection and diagnosis of gears using pattern recognition and Wavelet transform. It describes result of the comparison between KDI (Kullback Discrimination Information) with the nearest neighbor classification rule as one of pattern recognition methods and Wavelet transform to know a way to detect and diagnosis of gear damages experimentally. To model the damages 1) Normal (no defect), 2) one tooth is worn out, 3) All teeth faces are worn out 4) One tooth is broken. The vibration sensor was attached on the bearing housing. This produced the total time history data that is 20 pieces of each condition. We chose the standard data and measure distance between standard and tested data. In Wavelet transform analysis method, the time series data of magnitude in specified frequency (rotary and mesh frequency) were earned. As a result, the monitoring system using Wavelet transform method and KDI with nearest neighbor classification rule successfully detected and classified the damages from the experimental data.

  • PDF

Design Modification of Marine Turning Gear Based on Spur Planetary Gear (스퍼 유성감속기 기반 선박용 터닝기어의 설계 변경)

  • Kim, Kun-Woo;Lee, Jae-Wook;Jang, Jin-Seok;Oh, Joo-Young;Hong, Jong-Hae;Lee, Kang-Jae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.7-14
    • /
    • 2019
  • A marine turning gear controls the position of the piston-crank mechanism by rotating the flywheel of the marine engine at a low speed, which is the main auxiliary machine that enables the disassembly and maintenance of the engine. In this study, the safety factor for surface durability and tooth bending strength was improved by the design modification of the marine turning gear based on the spur planetary gear. Angular velocity, torque, and efficiency of the turning gear were measured using a reliability evaluation tester, and a multibody dynamics model for analysis corresponding to the test results was developed. Finally, it was confirmed that the design improvements improved the tooth surface damage of the sun gear in the 3rd reduction stage.

Optimal Design of Tooth Profile for High-Efficiency Gerotor Oil Pump (지로터 오일 펌프의 성능 향상을 위한 치형의 최적 설계)

  • Kim Jae Hun;Park Joon Hong;Jung Sung Yuen;Son Jin Hyuk;Kim Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.28-36
    • /
    • 2005
  • A gerotor pump is suitable for oil hydraulics of machine tools, automotive engines, compressors, constructions and other various applications, which are highly accepted by designers. Especially the pump is an essential machine element of an automotive engine to feed lubricant oil. However, related industries do not have necessary technology to design and optimize the pump and paid royalties of rotor profile on an advanced country. Also, gerotor pumps with unsettled design parameters have not been sufficiently analyzed from a theoretical view of design. Therefore, it is still very difficult for the pump designer and manufacturer to decide the specifications for the required gerotor pump by users. In this study, the design optimization has been carried out to determine the design parameters that maximize the specific flow rate and minimize the flow rate irregularity. Theoretical analyses and optimal design of the gerotor oil pump have been performed by mathematical base, numerical method and knowledge of kinematics. An automated design system of the tooth profile has been developed through Auto LISP language and CAD method considering various design parameters. Finally, an optimally designed model for a general type of a gerotor pump has been generated and experimentally verified for the pump performances.

The design of digital circuit for chaotic composition map (혼돈합성맵의 디지털회로설계)

  • Park, Kwang-Hyeon;Seo, Yong-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.652-657
    • /
    • 2013
  • In this paper the design methode of a separated composition state machine based on the compositive map with two chaotic maps together and the result of that is proposed. The digital circuits of chaotic composition map for the use of chaotic binary stream generator are designed in this work. The discretized truth table of chaotic composition function which is composed of two chaotic functions - the saw tooth function and skewed logistic function - is made out, and also simplefied Boolean algebras of digital circuits are obtained as a mathematical model. Consequently, the digital circuits of the map for chaotic composition function are presented in this paper.

Full mouth rehabilitation of iatrogenic attrition patient (의원성 마모 환자의 전악 수복 증례)

  • Lim, Na-Kyung;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.228-237
    • /
    • 2021
  • Physiologic tooth attrition is accepted as a natural change. But when pathologic changes, such as loss of occlusal vertical dimension, masticatory pain, loss of masticatory function, and loss of esthetics occur, restorative measures should be taken by dentist. A patient visited the clinic with the chief complaint of 'My lower teeth bite the palate and it hurts'. It was diagnosed as iatrogenic attrition of lower natural dentition caused by inappropriate upper restorations, resulting in traumatic overbite. Through model analysis and diagnostic wax up, increase in vertical dimension was decided. Upper and lower dentitions were restored with new prostheses. After restoration, satisfactory outcomes were achieved both in functional and esthetic aspects.

Adaptive Background Modeling Considering Stationary Object and Object Detection Technique based on Multiple Gaussian Distribution

  • Jeong, Jongmyeon;Choi, Jiyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.51-57
    • /
    • 2018
  • In this paper, we studied about the extraction of the parameter and implementation of speechreading system to recognize the Korean 8 vowel. Face features are detected by amplifying, reducing the image value and making a comparison between the image value which is represented for various value in various color space. The eyes position, the nose position, the inner boundary of lip, the outer boundary of upper lip and the outer line of the tooth is found to the feature and using the analysis the area of inner lip, the hight and width of inner lip, the outer line length of the tooth rate about a inner mouth area and the distance between the nose and outer boundary of upper lip are used for the parameter. 2400 data are gathered and analyzed. Based on this analysis, the neural net is constructed and the recognition experiments are performed. In the experiment, 5 normal persons were sampled. The observational error between samples was corrected using normalization method. The experiment show very encouraging result about the usefulness of the parameter.

A new minimally invasive guided endodontic microsurgery by cone beam computed tomography and 3-dimensional printing technology

  • Kim, Jong-Eun;Shim, June-Sung;Shin, Yooseok
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.29.1-29.7
    • /
    • 2019
  • Endodontic microsurgery is defined as the treatment performed on the root apices of an infected tooth, which was unresolved with conventional root canal therapy. Recently, the advanced technology in 3-dimensional model reconstruction based on computed tomography such as cone beam computed tomography has opened a new avenue in application of personalized, accurate diagnosis and has been increasingly used in the field of dentistry. Nevertheless, direct intra-oral localization of root apex based on the 3-dimensional information is extremely difficult and significant amount of bone removal is inevitable when freehand surgical procedure was employed. Moreover, gingival flap and alveolar bone fenestration are usually required, which leads to prolonged time of surgery, thereby increasing the chance of trauma as well as the risk of infection. The purpose of this case report is to present endodontic microsurgery using the guide template that can accurately target the position of apex for the treatment of an anterior tooth with calcified canal which was untreatable with conventional root canal therapy and unable to track the position of the apex due to the absence of fistula.

Prediction of Gear Bending Fatigue Life of Electro-mechanical Actuator for Aircraft Through Finite Element Analysis

  • Kim, Taehyung;Seok, Taehyeon;Kwon, Soon-hyeong;Lee, Byung-ho;Kwon, Byung-gi;Kwon, Jun-yong;Cheong, Seong-kyun
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.58-67
    • /
    • 2020
  • In this study, finite element fatigue analysis combined with a fatigue correlation factor is proposed to predict the bending fatigue life of a gear in an electro-mechanical aircraft actuator. First, stress-life curves are obtained for the gear material via a round bar fatigue test. Subsequently, stochastic stress-life (P-S-N) curves are derived for 50% and 1% failure probabilities, separately. The curves are applied to the fatigue analysis model of a single gear tooth, and the effect of the fatigue correction factor is analyzed. The analytical P-S-N curves reflecting the fatigue correction factor matched the experimental data. This shows that the analytical fatigue life is reliable and that the analysis technique is effective.

Clinical Validity of Tooth Size Measurements Obtained via Digital Methods with Intraoral Scanning

  • Mohammed, Alnefaie;Sun-Hyung, Park;Jung-Yul, Cha;Sung-Hwan, Choi
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.132-140
    • /
    • 2022
  • Purpose: Dental diagnostic records derived from study models are a popular method of obtaining reliable and vital information. Conventional plaster models are the most common method, however, they are being gradually replaced by digital impressions as technology advances. Moreover, three-dimensional dental models are becoming increasingly common in dental offices, and various methods are available for obtaining them. This study aimed to evaluate the accuracy of the measurement of dental digital models by comparing them with conventional plaster and to determine their clinical validity. Materials and Methods: The study was conducted on 16 patients' maxillary and mandibular dental models. Tooth size (TS), intercanine width (ICW), intermolar width (IMW), and Bolton analysis were taken by using a digital caliper on a plaster model obtained from each patient, while intraoral scans were manually measured using two digital analysis software. A one-way analysis of variance test was used to compare the dental measurements of the three methods. Result: No significant differences were reported between the TS, the ICW and IMW, and the Bolton analysis through the conventional and two digital groups. Conclusion: Measurements of TS, arch width, and Bolton analysis produced from digital models have shown acceptable clinical validity. No significant differences were observed between the three dental measurement techniques.