• Title/Summary/Keyword: Tooth model

Search Result 567, Processing Time 0.028 seconds

Correction of palatally displaced maxillary lateral incisors without brackets

  • Choi, Kyung-Hee;Lee, Yoonjung;Kim, Minji;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.201-206
    • /
    • 2013
  • This article describes the orthodontic treatment of a 25-year-old Korean female patient with anterior crowding, including palatally displaced lateral incisors. Her facial profile was satisfactory, but 3.5 mm of maxillary anterior crowding was observed. To correct this crowding, we decided to minimize the use of the conventional fixed orthodontic appliances and employed a less bulky and more aesthetic appliance for applying light continuous force. We determined the final positions of the maxillary teeth via a working model for diagnostic set up and achieved space gaining and alignment with simple Ni-Ti spring and stainless steel round tubes. Tooth alignment was achieved efficiently and aesthetically without the conventional brackets.

Efficient Method of Singular Value for Inverse Problem (역 문제에 대한 특이치 효율화)

  • Park, Sung-Oan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.232-240
    • /
    • 2012
  • This study proposed efficient method of singular value for inverse problem, linear approximation of contact position and loading in single and double meshing of transmission contact element, using 2-dimension model considered near the tooth by root stress. Determination of root stress is carried out for the gear tooth by finite element method and boundary element method. Boundary element discretization near contact point is carefully performed to keep high computational accuracy. The predicted results of boundary element method are good accordance with that of finite element method.

Design of Elliptical Gears for Wire Cutting (타원형 기어의 와이어커팅을 위한 설계)

  • Lee, Sung-Chul
    • Tribology and Lubricants
    • /
    • v.23 no.4
    • /
    • pp.149-155
    • /
    • 2007
  • The CAD model of a elliptical gear for wire cutting has been developed. The rolling contact of pitch ellipses whose rotation axes coincide with their focus has been analyzed, and the perimeter of the pitch ellipse has been divided into equal-length segments by the number of teeth. A master tooth profile, which is a composite curve of circular arcs that represents involute, has been introduced. The elliptical gear has been designed by imposing the master tooth on the divided points of the pitch ellipse, and a full fillet has been achieved between neighbour teeth. Thus, the whole profile of an elliptical gear is a composite curve of arcs only, and consequently NC codes for wire cutting can be easily generated. Furthermore, a computer simulation program is developed to verify the mesh of the elliptical gear.

A STUDY OF THE CROWN INCLINATION IN NORMAL OCCLUSIONS (정상 교합자의 치관 경사도에 관한 연구)

  • Jeong, Don-Young;Sohn, Byung-Hwa;Park, Young-Chuel
    • The korean journal of orthodontics
    • /
    • v.16 no.1
    • /
    • pp.155-165
    • /
    • 1986
  • Recently, straight-wire appliance is widely used with great concern in clinical orthodontic field. The purpose of this study was to collect the information of the straight-wire appliance and to determine the crown inclination in clinical orthodontics. The author analyzed the study model of 78 individuals with normal occlusion. The obtained results were as follows. 1. Mean, maximum value, minimum value and standard deviation of crown inclination of upper and lower teeth were obtained. 2. The lingual crown inclination of upper tooth had constant value from first premolar through second molar, the lingual crown inclination of lower tooth progressively increased from canine through second molar. 3. As Howes' ratio was decreased, the crown inclination of upper incisors was increased. 4. Narrowing the upper arch, the crown inclination of upper incisors was increased.

  • PDF

Reduction Design of Core Loss in Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기 전동기의 철손 저감 설계)

  • Lee, Su-Jin;Kim, Sung-Il;Kwon, Soon-O;Jung, Jae-Woo;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.760-761
    • /
    • 2008
  • This paper deals with the core loss as well as torque characteristics according to the change of stator shape in an interior permanent magnet synchronous motor (IPMSM). The finite element method and functional core loss data obtained by the steinmetz equation are used in order to estimate the core loss. To minimize the core loss caused by the shape of tooth tip, slot-area and volume of permanent magnet, those are all the same in each model. In the end, the ratio between tooth width and yoke thickness to minimize the core loss in the IPMSM is presented in this paper.

  • PDF

A study regarding the reaction of tetracycline solution in a discolored tooth model using hydroxyapatite granules.

  • Yamaguchi, H.;Shamoto, H.;Sugihara, H.;Yamazaki, Y.;Oshima, T.;Kobayashi, K.;Maeda, N.;Arai, T.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.564.2-564
    • /
    • 2001
  • For the purpose of explaining the mechanism of tooth discoloration caused by tetracycline (TC), a study was conducted by setting up the following in vitro system. Being evaluated were the TC concentration to give an optimum reaction state when it acted on hydroxyapatite(HA) granules and the absorbing wavelength of TC that had been irradiated with ultraviolet (UV) rays.(omitted)

  • PDF

Optimization of Design of Safety Block by Structural Analysis (구조해석을 통한 안전블록 설계 최적화)

  • Nam, K.W.;Gwon, H.S.;Son, C.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.3
    • /
    • pp.71-76
    • /
    • 2010
  • The safety block which prevents drop of laborers at high altitude was analyzed by finite element method. Elastic analysis was done by Ansys ver. 11.0. and tetrahedral meshing was used. As load applied more vertically at the fixed face of saw tooth, the stress concentration became smaller and the load distributed broader. When load worked at saw tooth and the shape was more straight to the direction of load, most stresses except principal stress became smaller. When the area of the load increased, principal stress and equivalent stress could be decreased simultaneously. A principal stress and other various stresses occurred in 3D shape, therefore revised model which has smaller equivalent stress than other models shows excellence on the stability and the credibility.

A Finite Element Analysis of Stress Distribution in the Tooth and Crown According to Design of Esthetic Crown (유한요소법을 이용한 심미치관보철의 설계에 따른 치아와 보철물의 응력분산에 관한 연구)

  • Lee, Myung-Kon;Chung, In-Sung;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.115-121
    • /
    • 1999
  • This investing was carried out to evaluate the alteration of stress distribution on teeth and esthetic crowns. Analyzing the stress distribution by the two-dimensional finite element methods, a model of lower 1st molar according to the porcelain fused metal crown an the porcelain fused glass ceramic core crown and the all glass ceramic crown. 1. The pattern of stress distribution showed no apparent differences. 2. The greatest von Mises values were concentrated around the central fossa of all esthetic crowns. The greatest Maximum principle value were concentrated around the interface between the base of esthetic crown and the abutment tooth. It was found that the apatite glass ceramic could be applicable for use in dental crown prosthesis.

  • PDF

Analysis of Torque on Spur Gear by Inverse Problem (역문제에 의한 평치차의 토크 해석)

  • 박성완;이장규;우창기;김봉각;윤종희;인승현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.3-10
    • /
    • 2002
  • This study proposed a technique for inverse problem, linear approximation of contact position and loading in single and double meshing of spur gear, using 2-dimension model considered near the tooth by root stress. Determine root stress is carried out for the gear tooth by finite element method and boundary element method. Boundary element discretization near contact point is carefully performed to keep high computational accuracy. And from those estimated results, the comparing estimate value with boundary element method value was discussed.

  • PDF

Analysis of Spiral Bevel Gear by Inverse Problem (역문제에 의한 스파이얼 베벨기어의 해석)

  • 박성완
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.5
    • /
    • pp.85-95
    • /
    • 2001
  • This study proposed a technique for inverse problem, linear approximation of contact position and loading in single and double meshing of spiral bevel gear , using 2-dimension model considered near the tooth by root stress. Determine root stress is carried out far the gear tooth by finite element method and boundary element method. Boundary element discretization near contact point is carefully performed to keep high computational accuracy. And from those estimated results, the comparing estimate value with boundary element method value was discussed.

  • PDF