• Title/Summary/Keyword: Tooth location

Search Result 159, Processing Time 0.026 seconds

Periodontal plastic surgery for anterior esthetics (전치부 심미치주성형술)

  • Lee, Yong-Moo
    • The Journal of the Korean dental association
    • /
    • v.48 no.12
    • /
    • pp.880-888
    • /
    • 2010
  • Periodontal disease, trauma, deformity of tooth can jeopardize the esthetics of oral and maxillo-facial region. Moreover, increasing the demand and concern about the esthetics, clinicians should place high value on esthetics during periodontal treatment. Analysis of various anatomical considerations; lip line, shape and location of marginal gingiva, and biologic width; and diagnosis should be performed prior to periodontal plastic surgery.

A Study of Complete Denture Stability (총의치 안정에 대한 연구)

  • Lee, Jai-Youl
    • Journal of Technologic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.15-18
    • /
    • 1984
  • A denture that shifts easily in response to latterally applied forces can cause a disruption in the border seal or prevent the denture base from Correctly relating to the supporting tissue. The factors that Contribute to stability include ridge height and conformation, base adaptation, residual ridge relationships, occlusion harmony, and Muscle control. These factors can be condensed into the following categories; 1. The relationship of the denture base to the underlying tissue. 2. The relationship of occlusal harmony. 3. The relationship of the denture surface and border to the surrounding muscle. 4. The location of artificial tooth.

  • PDF

ACOUSTIC EMISSION IN BENDING FATIGUE PROCESS OF CARBURIZING SPUR DEAR BY AE SOUTCE LICATION

  • Sentoku, Hirofumi;Yamato, Hiroyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.142-145
    • /
    • 1995
  • It is important from prevention of the malfunction and an important accident by the failuer, to detect a failuer in revolution devices. The acoustic emission(AE) method is expected as means that defects an abnormal phenomenon of revolution devices earlily and utilized. Although a research example by the AE method is reported regarding a gears, little reserch has been conducted using the AE method for running gears in a bending fatigue process of spur gear teeth. Therefore, in this report, with two micro AE sensors attached to the side of the gear, AE was measured in a bending fatigue process of a carburizing gear by using the power circurating-type machine and AE source location in gear teeth were required. By various analysis in these data, the AE characteristics in the fatigue damaging process of the gear tooth were determined.

  • PDF

Morphological Characterization and Classification of Anuran Tadpoles in Korea

  • Park, Dae-Sik;Cheong, Seo-Kwan;Sung, Ha-Cheol
    • Journal of Ecology and Environment
    • /
    • v.29 no.5
    • /
    • pp.425-432
    • /
    • 2006
  • The tadpoles of 12 Korean anuran species, including Bombina orientalis, Bufo gargarizans, B. stejnegeri, Hyla japonica, Kaloula borealis, Rana dybowskii, R. huanrenensis, R. coreana, R. nigromaculata, R. chosenica, R. rugosa, and R. catesbeiana, were classified based on their morphological characteristics. We collected eggs or tadpoles of the 12 Korean anuran species from Gangwon, Incheon, Chungcheong, and Gyeonggi districts in 2005 and 2006 breeding seasons. When the tadpoles reached at $27{\sim}37$ Gosner's developmental stages, we described morphological characteristics of the tadpoles of each anuran species and measured their physical parameters such as total length, body length, and body mass. After that, we chose 12 morphological characteristics to identify each species and to use them as classification keys such as eye location, caudal musculature pattern, spiracle location, oral disc morphology, and labial tooth row formula. In this paper, we presented classification keys, morphological characteristics, and drawings for the tadpoles of 12 anuran species.

A Study on the Remanufacturing for Drive Spur Gear in Planner Miller by Directed Energy Deposition

  • Jin, Chul-Kyu;Kim, Min-Woo;Woo, Jae-Hyeog
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_1
    • /
    • pp.941-952
    • /
    • 2022
  • In this study, additive manufacturing technology was applied to restore a planner miller that was unusable due to aging. The drive spur gear of the planner miller was inoperable due to many defects in the teeth. The shape of the defective gear teeth was restored by deposition of the defective teeth using the DED method. However, as the location of the deposition head and the location of the set origin became farther, the deposition shape was different from the modeling shape. Nonetheless, since the modeling of the deposition part was designed to be larger than the tooth shape of the original gear, it was possible to completely restore all gear teeth through post-processing. The arrangement interval of the flow lines of the deposition part was narrower than that of the substrate. The hardness of the substrate was 172 HV, and that of the deposition part was 345 HV, which was twice as high as that of the substrate.

Geometric Snapping for 3D Triangular Meshes and Its Applications (3차원 삼각형 메쉬에 대한 기하학적 스내핑과 그의 응용)

  • 유관희;하종성
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.239-246
    • /
    • 2004
  • Image snapping for an image moves the cursor location to nearby features in the image, such as edges. In this paper, we propose geometric snapping for 3D triangular meshes, which is extended from image snapping. Similar to image snapping, geometric snapping also moves the cursor location naturally to a location which represents main geometric features in the 3D triangular meshes. Movement of cursor is based on the approximate curvatures which appear geometric features on the 3D triangular meshes. The proposed geometric snapping can be applied to extract main geometric features on 3D triangular meshes. Moreover, it can be applied to extract the geometric features of a tooth which are necessary for generating the occlusal surfaces in dental prostheses.

A Peduncular Cystic Compound Odontoma on the Posterior Wall of the Maxillary Sinus (상악동후벽에 발생한 낭형 복합치아종)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.491-503
    • /
    • 1998
  • A cystic compound odontoma in the maxillary sinus occurred in a 13-year-old boy. who had missing right upper third molar without having the history of extraction of the wisdom tooth. He complained nasal stuffiness. headache. and pain on the affected face. resembling any sign and symptoms of the maxillary sinus problems. The cystic compound. sized 2 x 1.5 cm in diameter was pedunculated and attached on the posterior wall of the right maxillary sinus and above the antral floor. The location of the compound odontoma in the maxillary sinus was confirmed after panoramic. waters. spiral tomographic. CT examinations and surgical exploration. Its location was on the medial. posterior. superior to the normal position of the maxillary third molar or the maxillary dental arch. The cystic odontoma in the maxillary sinus made the patient have the signs and symptoms of maxillary sinusitis. The cystic compound odontoma might be originated from the dental lamina of the missing upper right third molar. The 'V principle' of the upper jaw growth and the pneumatization process of the maxillary sinus could explain why the compound odontoma had peduncular shape and the location of odontoma was on the medial. superior to the normal position of the maxillary dental arch.

  • PDF

ERUPTION DISTURBANCE ASSOCIATED WITH A DEVELOPING ODONTOMA (발육중인 치아종으로 인한 맹출 장애)

  • Ryu, Jae-Ryang;Kim, Young-Jin;Kim, Hyun-Jung;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.4
    • /
    • pp.505-511
    • /
    • 2010
  • Odontoma represents 22% of all odontogenic tumors, which is characterized by slow growth pattern. Most of the odontomas usually develop during dental follicle proliferation. The growth of odontoma is limited and lesion is generally asymptomatic. It is frequently diagnosed during assessments for delayed eruption of permanent tooth and is usually founded in the second decade of life. Odontoma is usually diagnosed through radiographic views and is difficult to diagnose at the early developmental stage of odontoma. But an uncalcified developing odontoma can disturb the eruption of the tooth, so it is important to perform periodic radiographic examinations. Treatments are surgical removal and observation of odontoma followed by surgical opening or orthodontic traction of impacted tooth according to the tooth development and the location of impacted tooth. In this case, we found the radiopaque calcified odontoma in the radiographic view meanwhile follow up of the impacted tooth showing idiopathic eruption disturbance. This suggests that a developing odontoma is the cause of eruption disturbace.

A Retrospective Clinical Study of Survival Rate for a Single Implant in Posterior Teeth (구치부 단일 임플란트의 생존율에 대한 후향적 연구)

  • Han, Sung-Il;Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.3
    • /
    • pp.186-199
    • /
    • 2012
  • Purpose: Single implants, of which screw loosening has been observed frequently, presents problems such as fixtures fractures, marginal bone loss, and inflammation of the soft tissue around the implant. However, the single implant is more conservative, cost effective, and predictable compared to the 3 unit bridge with respect to the long-term outcome. This study evaluated the survival rate as well as future methods aimed at increasing the survival rate in single implants in posterior teeth. Methods: Among the implants placed in the Dankook University Dental Hospital department of Oral & Maxillofacial surgery from January 2001 to June 2008, 599 implants placed in the maxillar and mandibular posterior were evaluated retrospectively. Survival rates were investigated according to implant location, cause of tooth loss, gender, age, general disease, fixture diameter and length, surface texture, implant type and shape, presence of bone graft, surgery stage, surgeons, bone quality and opposite teeth. Results: Out of 599 single implants in posterior teeth, 580 implants survived and the survival rate was 96.8%. The difference in survival rate was statistically significant according to the implant location. The survival rate was low (84.2%) in implants exhibiting a wide diameter (${\geq}5.1mm$) and the surface treated by the acid etching group demonstrated a significantly lower survival rate (91.1%). One stage surgical procedure, which implemented a relatively better bone quality survival rate (100%), was higher than the two stage surgical procedure (96.1%). The survival rate of type IV bone quality (75%) was significantly lower than the other bone quality. Conclusion: Single posterior teeth implant treatments should use an improved surface finishing fixture as well as careful and safe procedures when performing implant surgery in the maxilla premolar and molar regions since bone quality is poor.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.