• Title/Summary/Keyword: Tooth generation

Search Result 71, Processing Time 0.02 seconds

A Study on Composite Tooth Profile Generation of Involute and Circular Are (인벌류우트 - 圓孤 合成齒形의 創成 에 대한 硏究)

  • 최상동;변준형;윤갑영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.572-578
    • /
    • 1985
  • A composite gear with involute-circular are tooth profile and a tooth profile of the rack to cut this gear are theoretictically obtained. The composite gear has involute tooth profile in the vicinity of pitch point and has circular arc tooth profiles at addendum adn dedendum. The contact ratio(M$_{c}$), chordal tooth thickness (chordal tip tooth thickness S$_{t}$, chordal root tooth thickness S$_{t}$) of the composite gear are compared with those of involute gear. When module, number of teeth and pressure angle eqaul, S$_{t}$ of composite gear is much larger than that of involute gear. Under the same conditions, S/sib t/ and M$_{c}$ of composite gear become smaller than those of involute gear.lute gear.

Design of Gerotor with Pin-tooth Inner Rotor (핀치형 내부로터의 제로터 설계)

  • Lee, Sung-chul
    • Tribology and Lubricants
    • /
    • v.36 no.2
    • /
    • pp.64-67
    • /
    • 2020
  • In the conventional gerotor design, the circular arc tooth of the outer rotor is first introduced, and then the inner rotor profile is generated by simulating the outer rotor motion while the inner rotor is fixed. The profile generation of tooth meshing exhibits relativity; therefore, the outer rotor profile can be generated by the movement of the inner rotor. In this study, we propose the design of a gerotor with a pin-tooth inner rotor. First, the pin-tooth inner rotor is devised, and then the outer rotor profile is generated. The profile of the inner rotor is simply composed of equally arranged pins along a circle. The root of the inner rotor is designed as a conjugated arc of two pins. The trajectory of the pin center is obtained by the inner rotor operation, and then the outer rotor profile is determined as a parallel curve of the trajectory. In this gerotor design, the inner rotor has a simple configuration, and contact occurs between the pin parts of the inner rotor and the whole profile of the outer rotor. This affects the material selection and machining process. The pin tooth can be used to design the outer and inner rotors, enabling a double gerotor mechanism corresponding to a planetary gear system.

A Study of Algorithm on the Freefrom Curve Gear (자유곡선 기어의 창성 알고리즘에 관한 연구)

  • 최종근
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.5
    • /
    • pp.96-101
    • /
    • 1999
  • This study suggests an algorithm for tooth profile generation of free from curve involute gear, a special gear of which the pitch line is a free curve instead of a circular one. For the first, a methodology for calculation of the tooth curve is developed and formulated Then the formulated algorithm, is programmed for manufacturing and verified by computer graphics. Next the calculated results as changed in to NC codes to apply to wire electric discharge machine(WEDM). Finally, the machined gear is examined in engagement with a standard involute gear.

  • PDF

A Study on The Tooth Creating Algorithms of The Cycloid Curve Gear and The Third Polynomial Curve Gear (사이클로이드 곡선 및 3차 다항식 곡선기어의 치형 설계에 관한 연구)

  • 최종근;윤경태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.3
    • /
    • pp.80-85
    • /
    • 2002
  • The free curve gear is a non-circular gear without any relating center, which can perform free curve motion for complicated mechanisms, and minimize the work area. In this study, an algorithms for tooth profile generation of free curve involute gear is developed. The algorithm uses the involute gear creating principle in which a gear can be generated by rolling with another standard involute one. Cycloid me and third polynomial curve gears were designed and verified by computer graphics. These gears are manufactured in the wire-cut EDM and examined in engagement with a standard spur gear. The results showed that the proposed algorithm is successful to design and to manufacture the free curve gear with concave and convex profiles.

Familial Tooth Bone Graft: Case Reports (가족치아를 이용한 골이식술: 증례보고)

  • Lee, Ji-Young;Kim, Young-Kyun;Um, In-Woong;Choi, Joon-Ho
    • The Journal of the Korean dental association
    • /
    • v.51 no.8
    • /
    • pp.459-467
    • /
    • 2013
  • The use of autogenous tooth bone graft material has been commercialized since 2008. Autogenous tooth bone grafts always require that the tooth of the patient be extracted, and thus, the use of graft material are limited in many cases. For solution of limitation in quantity and concurrent use of autogenous tooth bone graft material, the grafting of familial teeth has been suggested. It has the following advantages: the teeth of family members are used as bone graft materials, the genetic composition is identical, and potential genetic and infectious risks can be minimized. Because the teeth of family members are used, a good tissue affinity is obtained, and thus, superior bone generation rates compared to those observed for allogenic or xenogenic bones can be anticipated. We used familial tooth bone-graft materials for alveolar ridge augmentation, socket preservation, and maxillary sinus graft in some cases. In most cases, the impacted third molars of their children were prepared as bone graft material and were used for surgery. In one case, the impacted third molar from the patient's brother was used as bone graft material. We obtained satisfactory result and these cases are reported herein.

Effects of Citrus limon Extract on Oxidative Stress-Induced Nitric Oxide Generation and Bovine Teeth Bleaching

  • Jeong, Soon-Jeong
    • Journal of dental hygiene science
    • /
    • v.21 no.2
    • /
    • pp.96-103
    • /
    • 2021
  • Background: We aimed to investigate the effect of Citrous limon extract (CLE) on oxidative stress-induced cytotoxicity and nitric oxide (NO) generation and the tooth bleaching effect of CLE as a substitute for hydrogen peroxide (H2O2) and determine the feasibility and application of CLE as a safe and effective natural tooth bleaching agent. Methods: The protective effect of CLE on H2O2-induced cytotoxicity in Raw264.7 macrophages was investigated by the MTT assay. The inhibitory effect of CLE on the generation of H2O2-induced NO was confirmed by the NO assay, and the changes in inducible nitric oxide synthase (iNOS) protein expression were confirmed by western blotting. Stained bovine teeth were treated with/without 15% and/or 35% CLE and H2O2, 15% sodium bicarbonate (NaHCO3) for 3 hours, and were irradiated with/without bleaching light (BL) for 15 minutes. The color change of the treated bovine tooth surface was measured using a colorimeter. Results: The viability of Raw264.7 cells treated with each concentration of CLE and 500 μM H2O2 significantly increased as CLE increased, and NO generation and iNOS protein expression were significantly reduced in cells treated with 300 ㎍ CLE+/500 μM H2O2+ and 300 ㎍ CLE+/500 μM H2O2+/150 ㎍ NaHCO3+. The bleaching effect of 35% CLE+ was higher than that of 15% CLE+ and 15% NaHCO3+, and the effect was similar to that of 15% H2O2+. The 35% CLE+/15% NaHCO3+ showed the greatest bleaching effect and was higher than that of the groups irradiated with the BL. The greatest bleaching effect was observed with 35% CLE+/15% NaHCO3+, followed by 35% H2O2+/BL+. Conclusion: CLE inhibited oxidative stress-induced cytotoxicity and NO generation in Raw264.7 cells and, could replace H2O2, which causes side effects and risks in teeth breaching treatment. It showed greatest teeth bleaching effect when combined with NaHCO3. CLE is an effective and safe natural tooth bleaching substitute.

Prescription of antibiotics after tooth extraction in adults: a nationwide study in Korea

  • Choi, Yoon-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.1
    • /
    • pp.49-57
    • /
    • 2020
  • Objectives: This study aimed to understand the nationwide patterns of antibiotic prescription after tooth extraction in adult patients. Materials and Methods: This study analyzed dental records from the National Health Insurance Service-National Sample Cohort (NHIS-NSC) database on 503,725 tooth extractions performed in adults (≥19 years) during 2011-2015. Patient sex, age, household income, systemic disease (diabetes mellitus and hypertension), type of dental institution, region of dental institution, year of prescription, and type of tooth extraction procedure were considered. The antibiotic prescription rate and broad-spectrum antibiotic prescription frequency were analyzed using chi-squared tests. Factors affecting the prescription of broad-spectrum antibiotics were evaluated using multivariate logistic regression analysis. Results: The rate of antibiotic prescription after tooth extraction was 81.85%. Penicillin was most commonly prescribed (45.25%), followed by penicillin with beta-lactamase inhibitors (18.76%), metronidazole (12.29%), and second- to fourth-generation cephalosporins (11.52%). The proportion of broad-spectrum antibiotics used among all prescribed antibiotics was 45.88%. Conclusion: The findings of this study demonstrate that the rate of antibiotic prescription after tooth extraction is higher in Korea than in other countries. Furthermore, broad-spectrum antibiotics are used more frequently, which may indicate unnecessary drug prescription, an important contributor to antibiotic resistance.

Effect of Tooth-Cut Induced Dental Malocclusion on Mouse Model of Ischemic Stroke (생쥐의 하악 치아 절단으로 인한 부정교합이 뇌경색에 미치는 영향)

  • Lee, Young-Jun;Lee, Byoungho;Cho, Suin
    • Journal of TMJ Balancing Medicine
    • /
    • v.9 no.1
    • /
    • pp.4-11
    • /
    • 2019
  • Objectives: Although intraoral balancing appliance therapy has been used effective to several diseases, verification studies through cerebral diseases are poorly reported so far. Thus we investigated the effect of tooth-cut induced dental malocclusion against mouse model of ischemic stroke. Methods: Tooth-cut and 90 min middle cerebral artery occlusion (MCAO) were loaded to C57BL/6 male mice, and total infarct area, neurological deficit scores (NDS), histological change of hippocampal region were observed. Production levels of reactive oxygen species (ROS) and inducible nitric oxide synthase (iNOS) in cerebral tissue were also measured. Results: The longer the tooth-cut period, the greater the area of cerebral infarction caused by MCAO, and NDS began to increase as the tooth was cut, and the results were more negative when MCAO was loaded. Histological change of hippocampal cells was significant when tooth-cut was maintained for 7 days. Those damages were thought to depend on the generation of ROS and iNOS in brain tissue. Conclusions: Since tooth-cut increased total area of cerebral infarction due to MCAO in mice, it is able to be confirmed that anomaly of the temporomandibular occlusion can affect neurological diseases.

  • PDF

Optimizing the design factors of the head-feed type combine(II) -Threshing characteristics of the head-feed threshing teeth- (자탈형 콤바인 탈곡부 설계요인(設計要因)의 적정화(適正化)를 위한 연구(硏究)(II) -탈곡치의 탈곡특성-)

  • Nam, S.I.;Chung, C.J.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.4
    • /
    • pp.9-19
    • /
    • 1988
  • The threshing of head-feed combine may be accomplished mainly by the action of impact between threshing teeth and rice. In this study, it was attempted to assess threshing performance characteristics of head-feed threshing teeth. And the characteristics of threshing teeth will be applied to the method which could analyze the time and order of impact between teeth and the rice, which was used as a basis for predicting the threshing performance and determining the optimum design parameters. The results of the study are summarized as follows: 1. About 50% of threshed material were threshed by the beginning 7 impacts on the rice bundle. Threshing torque decreased until 25 impacts and did not change thereafter. 2. There was significant difference in the threshability according to the shape of threshing teeth. The triangular-shaped tooth was the most efficient in threshability ratio and the semicircle-shaped tooth was the lowest. There was no significant difference in specific energy requirement for the varied teeth design. Torn-head ratio being generated by the semicircle-shaped and the triangular-shaped teeth in series was less than that by a single tooth with the triangular-shaped and the double setting of the triangular-shaped. Chaff generation ratio by the triangular-shaped and the semicircle-shaped teeth was less than the others tried. 3. The triangular-shaped teeth in series, which was newly designed for this study, showed an intermediate characteristics between the double setting of the triangular-shaped and the semicircle- shaped teeth. Threshability ratio of the triangular-shaped teeth in series was higher than that of the semicircle and lower than the double setting of the triangular-shaped tooth. Torn-head generation ratio for it was about same as that of the semicircle. Chaff being generated by the triangular-shaped teeth in series was about same as the double setting of the triangular-shaped teeth. 4. About 40% of threshed grains which passed through concave were concentrated under the threshing tooth and the rest of grains displayed a skew distribution toward the inlet of threshing chamber.

  • PDF

Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

  • Kim, Do-Yoon;Lim, Bum-Soon;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at $36.5^{\circ}C$. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.