• Title/Summary/Keyword: Tooth fractures

Search Result 99, Processing Time 0.022 seconds

The Biological Stability of Immediate Placement of Tapered Implants in Tooth Extraction Sites (발치와에 즉시 식립한 쐐기형 임플란트의 생물학적 안정성에 관한 전향적 연구)

  • Park, Ja-young;Bae, Ahran;Kim, Hyung-Seub;Kwon, Yong-Dae;Lee, Baek-Soo;Kwon, Kung-Rock
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.139-155
    • /
    • 2009
  • Objective : To assess the biological stability of immediate transmucosal placement of tapered implants into tooth extraction sockets. Material and methods : Following tooth extraction, tapered implants were immediately placed into the sockets. Teeth with evidence of acute periapical pathology were excluded. After implant placement, sutured allowing a non-submerged, transmucosal healing. Standardized radiographs were obtained every visiting from baseline to 32 weeks after implant placment. Changes in depth of the distance from the implant shoulder (IS) and from the alveolar crest (AC) to the bottom of the defect (BD) were assessed. Results : Thirteen patients (10 males and 3 females) were enrolled and followed. They contributed with 15 tapered implants. extraction iste displayed sufficient residual bone volume to allow primary stability of all implants. The mean surgery time was $41{\pm}10.0$ mins. All implants healed uneventfully yielding a survival rate of 100%. Mean ISQ values were relatively stable. Interproximal crestal bone decreased $1.69{\pm}1.2mm$ (mesial), $1.65{\pm}1.2mm$ (distal) from baseline to 32-week follow-up. No statistically significant changes with respect to FMPS, FMBS, PPD and width of KG were observed. Conclusions: Immediate transmucosal implant placement represented a predictable treatment option for the replacement of teeth lost due to reasons including fractures, endodontic failures and caries.

A STUDY ON AN INTERPRETATION OF THE ORTHOPANTOMOGRAPH IN THE MIXED DENTITION (Orthopantomograph에 의(依)한 혼합치열상(混合齒列像)의 해석(解析)에 관(關)한 연구(硏究))

  • Kim, Kwang Won
    • The korean journal of orthodontics
    • /
    • v.12 no.2
    • /
    • pp.145-154
    • /
    • 1982
  • Plaster models were constructed and orthopantomographs were taken for 86 male and 70 female primary school pupils, whose upper and lower permanent 4 incisors and 1st molars were completely erupted without crowding; whose deciduous canines and molars were found almost uniformly even without any visible tooth fractures, dental caries or restorations on proximal surfaces of the teeth. Certain reference points on the orthophantomograph were set up and measured and the values were compared with actual or predicted values from the models. The following results were obtained: 1. In regards to available space, the values from the orthopantomograph were greater than the values from the models by a mean of 3.24% on the upper and 10.06% on the lower for males; 3.05% on the upper and 10.01% on the lower for females. 2. In regards to total mesiodistal widths of permanent canine, 1st and 2nd premolars, the values from the orthopantomograph were greater than the presumed values based on the size of lower permanent 4 incisors from the models by a mean of 18.50% on the upper and 24.09% on the lower for males; 14.54 on the upper and 20.51% on the lower for females. 3. Comparing the magnified values of total mesiodistal widths of permanent canine, 1st and 2nd premolars with those of available space, the regression constants of regression equation (Y = a + bX) between them were a=3.2336, b=0.6533 on the upper and a=5.0138, b=0.3290 on the lower for males; a=2.5994, b=0.6521 on the upper and a=3.0113, b=0.6586 on the lower for females. 4. The correlation coefficients between the magnified values of available space and permanent canine, 1st and 2nd premolars were moderately positive as 0.6474 in the upper and 0.505 on the lower for males; 0.6493 on the upper and 0.6183 on the lower for females. 5. In regards to magnified values of the available space from the orthopantomographs there were no significant difference between sexes, (P>0.05) but of the total mesiodistal widths of permanent canine, 1st and 2nd premolars, a significant difference between sexes was found.(p<0.01).

  • PDF

MARGINAL FIDELITY AND FRACTURE STRENGTH OF IPS EMPRESS $2^{(R)}$ CERAMIC CROWNS ACCORDING TO DIFFERENT CEMENT TYPES

  • Cho Hyun-Ok;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.6
    • /
    • pp.545-559
    • /
    • 2002
  • There has been increasing use of IPS Empress $2^{(R)}$ owing to easy fabrication method, high esthetics similar to natural teeth, good marginal accuracy, and sufficient fracture strength. However, in clinical application, although a luting agent and the tooth cementation bonding procedure influence the marginal accuracy and fracture strength restoration, there has been a controversy in the selection of proper luting agent. This study was to measure the marginal fidelites and fracture strength of IPS Empress crowns according to three cement types, Protec $cem^{(R)}$, Variolink $II^{(R)}$ and Panavia $21^{(R)}$. After construction of 12 experimental dies for each group, IPS Empress $2^{(R)}$ crowns were fabricated and luted the metal master die prepartion of the maxillary right premolar. Marginal gaps before cementation and after cementation were measured. Buccal incline on the functional cusp of specimens were loaded until the catastrophic failure and fracture strength was measured. The results of this study were as follows: 1. The range of gap was $34.04{\pm}4.84{\mu}m$ before cementation and $37.88{\pm}5.00{\mu}m$ after cementation, which showed significant difference by paired t-test (p<0.05). The difference in the results from marginal accuracy according to measuring point proved to be not statistically significant by two-way ANOVA test (p>0.05). 2. The difference in the results from marginal accuracy according to three cement types Proved that The Variolink $II^{(R)}$ cement group had the least gap, $35.43{\pm}5.03{\mu}m$, and showed superior marginal accuracy while there existed statistic significance in Protec $cem^{(R)}$ cement group, $39.06{\pm}4.41{\mu}m$ or Panavia $21^{(R)}$ cement group, $39.16{\pm}4.39{\mu}m$ by two-way ANOVA test & multiple range test (p<0.05). 3. The difference in the results from fractures strength testing according to three cement type groups proved to be statistically significant (p<0.05). The Variolink $II^{(R)}$ cement group shows highest fracture strength of $1257.33{\pm}226.77N$, Panavia $21^{(R)}$ cement group has $1098.08{\pm}138.45N$, and Protec $cem^{(R)}$ cement group represents the lowest fracture strength of $926.75{\pm}115.75N$. 4. Three different cement groups of different components showed acceptable marginal fidelity and fracture strength. It is concluded that IPS Empress $2^{(R)}$ crowns luted using Variolink $II^{(R)}$ cement group had stronger fracture strength and smaller marginal gap than the other cement groups. Although Variolink $II^{(R)}$ resin cement seemed acceptable to clinical applications in IPS Empress $2^{(R)}$ system, the IPS Empress $2^{(R)}$ system still requires long-term research due to the lack of data in clinical applications.

TYPE II DENTINOGENESIS IMPERFECTA : CASE REPORT (Type II 상아질형성부전증의 임상 증례)

  • Kim, Chi-Hyun;Lee, Jae-Ho;Choi, Byung-Jai;Lee, Chong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.654-660
    • /
    • 2001
  • Dentinogenesis imperfecta is an example of an inheritable dentinal defect originating during the histodifferentiation stage of tooth development, with involvement of the primary and permanent teeth. Shields, Bixler and El-Kafrawy proposed three types of Dentinogenesis imperfecta : Type I, II, III. Witkop reported a prevalence of 1 in 8000 with the trait, and no significant difference between male and female. Affected teeth have red-brown discoloration often with distinctive wearness of occlusal surface of posterior teeth and incisal surface of anterior teeth. Once enamel seperated from underlying defective dentin, the dentin demonstrates significantly acclerated attrision. Radiographically, the teeth have thin roots, bulbous crown, cervical constriction, and obliteration of the root canals and pulp chambers. In primary dentition periapical lesions or multiple root fractures are often observed. In successive generations the phenotypes of discoloration and wearness of teeth occurred, and one of the patient's subships, 10 year-old sister, showed general discoloration of her teeth and mild wearness. In this case, a 4 year-old male reported to the Yonsei University Pedodontics clinic, with a chief complaint of discolored teeth. The teeth showed generally yellowish-brown discoloration and moderate wearness. In radiographic features, obliteration of pulp, bulbous crown, and short roots were observed. It was diagnosed as Dentinogenesis imperfecta. The posterior teeth were restored with Stainless Steel Crown, and defective incisors including left upper primary central incisor which was extracted due to a root fracture with Open-faced Stainless Steel crown.

  • PDF

FRACTURE STRENGTH BETWEEN DIFFERENT CONNECTOR DESIGNS OF ZIRCONIA CORE FOR POSTERIOR FIXED PARTIAL DENTURES MANUFACTURED WITH CAD/CAM SYSTEM (CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도)

  • Seo Jun-Yong;Park In-Nim;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.29-39
    • /
    • 2006
  • Statements of problem: Zirconia core is used for posterior fixed partial dentures because it's good mechanical properties. Stress is concentrated on connectors in fixed partial dentures, so the proper design of connector areas is needed for adequate mechanical long-term properties of any prosthesis. The area of connector is critical, but tooth size and surrounding soft tissue limit the connector design. Purpose: The purpose of this study is to compare fracture strengths between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system and determining the optimal connector design satisfying strength and hygiene. Material and method: The following four groups of 40 posterior fixed partial denture specimens(each group 10) were fabricated as followed; group 1 vertical height of connector is 3mm (control group, all groups have the same condition); group 2, lingual vertical 1mm reinforcement on connector; group 3, lingual vertical 2mm reinforcing on connector and group 4, lingual vertical 3mm reinforcing on connector. Specimens were subjected to compressive loading on the central fossa of pontic by instron. SEM was used to identify the initial crack and characterize the fracture mode. Results: The results were as follows: 1. The mean fracture load of the non-lingual reinforcing group was 1212N and the lingual vertical 1mm reinforcing group was 1510N, the lingual vertical 2mm reinforcing group was 1882N, the lingual vertical 3mm reinforcing group was 1980N. 2. The reinforcing groups were statistically significant compared to non-reinforcing groups(P<0.001). 3. There were 2, 3mm reinforcing groups that were statistically significant compared to 1mm reinforcing groups(P<0.001), and the 3mm reinforcing group was not statistically significant compared to 2mm reinforcing groups(P>0.05) 4. Fractures were initiated in gingival embrasures of connectors and processed to the loading site. Conclusion: In this study, lingual reinforcement of connector for improved strength of zirconia based fixed partial denture is nessasary. And long-term study for clinical application is required

A study on the occlusal wear patterns in maxillary posterior teeth with palatal side abfractions (구개측 굴곡파절이 있는 상악 구치의 교합면 마모 양상에 대한 연구)

  • Song, Joo-Hun;Kim, Hee-Jung;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.153-159
    • /
    • 2019
  • Purpose: Aims to analyze the occlusal wear patterns in maxillary posterior teeth with palatal side abfractions and study the association between occlusal force and abfractions. Materials and Methods: This study was conducted in a total of 308 teeth from 148 patients with palatal side abfractions in maxillary posterior teeth. The occlusal wears in maxillary premolars and molars with palatal side abfractions were classified and recorded. The classification was done by type of teeth, age, and gender, and in order to evaluate the statistical significance between groups, chi-square test was conducted (${\alpha}=0.05$). Results: Palatal side abfractions in maxillary posterior teeth were observed at the highest frequency in the 1st molars, and in all teeth with palatal side abfractions, more than one occlusal wear was observed. In classification by type of teeth, by age, and by gender, the occlusal wears in teeth with palatal side abfractions were observed at high frequency in cuspal inclined plane, central fossa, and marginal ridge, and there was a statistical significance (P < 0.05). Conclusion: Palatal side abfractions were observed at the highest frequency in maxillary 1st molars, and in all maxillary posterior teeth where palatal side abfractions were found, the occlusal wears were observed. And the occlusal wears were observed at high frequency in cuspal inclined plane, central fossa and marginal ridge. Such results show that abfraction is associated with occlusal force.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

AN INVESTIGATION OF TRAUMATIC DENTAL INJURIES IN CHILDREN (소아의 치아와 지지조직 외상에 관한 분석)

  • Baik, Byeong-Ju;Yang, Yeon-Mi;Yang, Cheol-Hee;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.600-612
    • /
    • 2001
  • The purpose of this study is concerned with an investigation of the actual condition of traumatic injuries of teeth and supporting structures in children to set up possible criteria for prevention and treatment of injured teeth. The materials consisted of the clinical records of 431 traumatically injured teeth of 212 children, accumulated during two years from the first of April in 1998 to the end of March in 2000, supplied from the Dept. of Pediatric Dentistry, Chonbuk National University Hospital. The incidence of injuries in boys was extremely high for permanent teeth, twice as high as in girls. Accidents to primary teeth were most common from 1 to 2 years of age and to permanent teeth were most from 8 to 9 years of age. The most common cause of trauma was a fall for both primary and permanent teeth, followed by collision. The anterior teeth in maxilla was most frequently affected by trauma in both the primary and permanent teeth. The most common type of trauma were loosening for the primary teeth, followed by luxation types which included the intrusion, displacement and extrusion and complete avulsion types. For the permanent teeth, the most common type of trauma were tooth fracture. The most common trauma of soft tissue was laceration of upper lip, lower lip and gingiva of maxilla Concerning treatment at the first visit, primary teeth with only loosening and concussion were not usually treated. Permanent teeth were often treated by crown restorations for crown fractures and by endodontic procedures for pulpal exposure. Though we could elucidate actual condition of traumatic injuries of teeth in children, we should make a follow-up survey to ensure the prognosis of injured teeth and establish the most desirable criteria for traumatized teeth in children.

  • PDF