• Title/Summary/Keyword: Tooth Splinting

Search Result 34, Processing Time 0.024 seconds

Effect of splinting on abutment tooth movement when a distal extension partial denture used(II) (유리단국부의치(遊離端局部義齒) 사용시(使用時) 지태치(支台齒) 동요(動搖)에 대한 Splingting의 효과(效果)(II))

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.85-90
    • /
    • 1986
  • The effect of splinting on aqbutment tooth distal movement was performed in vitro study. An acrylic resin mandibular model with missing 2nd premolars, molars and a removable partial denture framework were constructed. The roots of the canines, 1st premolars and edentulous ridges were coated with silicone rubber. A modified Ney Surveyor was used for vertical load appkication, and abutment tooth distal movement were measured with a dial gauge with four conditions of splinting methods were tested by applying unilateral vertical loadings. The results are follows; 1. The magnitude of abutment tooth distal movement on the non-load side was less 40$\sim$69% than that occurred on the load side. 2. On the load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(30%), non-load side double abutment(10%), double abutments of both sides(40%) was compared with single abutments of both sides. 3. On the non-load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(5%), non-load side double abutment(22%), double abutments of both sides(59%) was compared with single abutments of both sides. 4. The magnitude of abutment tooth distal movement in the condition of double abutments of both sides was less 40$\sim$59% than that in the condition of single abutments of both sides.

  • PDF

A 3-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE SUPPORTING TISSUES OF REMOVABLE PARTIAL DENTURES WITH VARIOUS RETAINER DESIGNS (국소의치 유지장치의 설계변화에 따른 지지조직의 3차원적 유한요소법 응력분석)

  • Kim, Ki-Sook;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.413-439
    • /
    • 1995
  • The purpose of this study was to evaluate the stress distribution developed in the supporting structures by mandibular distal extension removable partial dentures with 2 different direct retainer designs and with or without indirect retainer and abutment splinting. The examined direct retainers on the second bicuspid abutment tooth were Akers clasp and RPA clasp, the indirect retainer was located on the mesial fossa of the first bicuspid, and the first and second bicuspid were splinted in case of tooth splinting. Total 8 cases were compared and analyzed with 3-dimensional finite element method. 150N were applied vertically on the artificial teeth of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows : 1. The forces transmitted to the abutment tooth were primarily from the occlusal rests. 2. The abutment tooth was displaced distally when the force was applied. The compressive stress was observed at the distal root surface of the abutment tooth and the tensile stress, at the mesial root surface. 3. The denture base was displaced posteriorly and inferiorly when the force was applied. At the more distal portion of the denture base, the greater displacement was observed.And the anterior portion of the major connector was displaced superiorly. 4. The occlusal rest placed on the distal part of the abutment tooth tended to tip the tooth more posteriorly than did one on the mesial part of that tooth. 5. Severe superior displacement was observed at the anterior portion of the major connector in case of removable partial dentures without indirect retainer. 6. In case of tooth-splinting, the stress was distributed through all the root surface of both abuments. In case of no tooth-splinting, the stress was concentrated on the distal root surface of the primary abutment.

  • PDF

The Effect of Splinting Methods on the Rearrangement of Periodontal Fibers after Tooth Movement in Adult Dogs (치아이동 후 고정방법이 성견 치주인대 섬유의 재배열에 미치는 영향)

  • Lee, Kr-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.825-837
    • /
    • 1997
  • The purpose of this study was to evaluate the effect of splinting methods on the rearrangement of periodontal fibers after experimental tooth movement. Orthodontic force was applied by placing closed coil spring between upper third incisor and canine in seven dogs, weighing 20 kg or more. After 3 weeks of force application, 0.0215 inch multistrand wire and polyethylene ribbon were bonded to each side, as a flexible and rigid splinting respectively in 6 experimental animals. The remaining one served as a control. Each two animals were sacrificed at 4, 8 and 12 weeks after splinting respectively and prepared histologically for hematoxylin-eosin and Masson's trichrome staining. The results of this study were obtained as follows: 1. After tooth movement, periodontal space was narrowed and periodontal titers were thick on pressure side while elongated fibers were observed on tension side. 2. After 4 weeks of retention, the rearrangement of periodontal fibers was observed in the flexible splinting group, but not in the rigid splinting group. 3. After 8 weeks of retention, the rearrangement of periodontal titers was observed in both groups, but the difference could not be detected between two groups. 4. During the retention period, the rearrangement of periodontal fibers was faster in tension side than in pressure side. These results show that the rearrangement of periodontal fibers is also obtained by rigid splinting after tooth movement. It is suggested that the rigid splinting by polyethylene ribbon can be used as a way of postorthodontic retention.

  • PDF

Periodontal and prosthetic treatment of maxillary incisors with pathological tooth migration: a case report with 10-year follow-up (병적 치아 이동된 상악 전치의 치주, 보철 치료 후 10년 경과 증례)

  • Kim, So-Yeun;Kwon, Eun-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.26-33
    • /
    • 2022
  • Anterior tooth spacing is observed by pathological tooth movement (PTM), which is common in periodontal patients. And various occlusal factors contribute to PTM, especially in the maxillary anterior region, when there is excessive occlusal force, flaring due to position problem easily occurs. Teeth with loss of periodontal support tissue can secure stability when expanding the support area through intentional splinting, and change the occlusion when restored as a fixed prosthesis. After confirming the stable occlusion through the provisional prosthesis, it can be transferred to the final prosthesis through CAD-CAM. In this case, we present a long-term stable case through accurate diagnosis and treatment of the maxillary anterior teeth that have lost interdental contact.

TRAUMATIZED TOOTH STABILIZATION USING VACUUM-FORMED SPLINT IN A CEREBRAL PALSY PATIENT (뇌병변 장애 환자의 외상 치아에서 vacuum-formed splint를 이용한 교합 안정술)

  • Nam, Ok Hyung;Park, Jae-Hong;Kim, Kwang Chul;Choi, Yeong Chul;Choi, Sung Chul
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.10 no.2
    • /
    • pp.89-92
    • /
    • 2014
  • Reposition and splinting has been widely recommended when clinicians treat traumatically dislocated tooth. This case represents stabilization of traumatized tooth in a cerebral palsy patient who failed resin wire splint because of parafunctional oral habit and lack of cooperation. Clinically, mobility of traumatized tooth decreased due to stabilization using vacuum-formed splint with posterior occlusal block in 2 weeks. Vacuum-formed splint may be a simple and effective stabilization technique for traumatized tooth in a cerebral palsy patient.

Flexibility of resin splint systems for traumatized teeth (외상성 치아모형에서의 레진 스플린트 시스템의 유연성 비교연구)

  • Park, Jin-Hong;Shin, Joo-Hee;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.389-393
    • /
    • 2017
  • Purpose: The aim of this study is to evaluate the flexural strength of flexible resins and the flexibility of different resin splint (RS) systems in comparison with resin wire splint (RWS) system. Materials and methods: Three different resin materials (G-aenial flo, GA, GC; Superbond, SB, Sun medical; G-fix, GF, GC) were tested flexural strength test in accordance with ISO-4049:2000. For the flexibility test of splint systems, a artificial model with resin teeth was used to evaluate three types of resin splint systems (GA, SB, and GF) and one resin wire splint system. The left central incisor was simulated 'injured teeth' with third degree mobility. Three consecutively repeated measurements of periotest value were taken in horizontal direction, before and after splinting to access tooth mobility. The splinting effect was calculated through the periotest value. Differences were evaluated through One-way Anova and Tukey HDS post-hoc tests for pair-wise comparison (${\alpha}=.05$). Results: Although GA group showed significant higher flexural strength than SB and GF groups, all of three different resin splint systems produced a significantly higher and rigid splinting effect compared with 016" resin-wire splint system (P < .05). Conclusion: Within the limits of an in vitro study, it can be stated that resin splint systems are too rigid and may not be acceptable to treat tooth avulsion.

Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment (법랑질 표면 처리방법에 따른 레진계 치아 고정재료의 접착강도 비교)

  • Lee, Ye-Rim;Kim, Soo-Yeon;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.72-80
    • /
    • 2019
  • Purpose: The purpose of this study is to compare and analyze the shear bond strength and fracture pattern in different enamel tooth surface treatments for resin splinting materials. Materials and Methods: G-FIX and LightFix were used as tooth splinting materials. Twenty bovine mandibular incisors were used for the preparation of the specimens. The exposed enamel surface was separated into four parts. Each tooth was treated with 37% phosphoric acid, 37% phosphoric acid + adhesive resin, 37% phosphoric acid + G-premio bond, and G-premio bond for each fraction. Shear bond strength was measured using a universal testing machine. After measuring the shear bond strength, the fractured surface of the specimen was magnified with a microscope to observe the fracture pattern. Two-way ANOVA was used to verify the interaction between the material and the surface treatment method. One-way ANOVA was used for comparison between the surface treatment methods of each material and post-hoc test was conducted with Scheffe's test. An independent t-test was conducted to compare shear bond strengths between materials in each surface treatment method. All statistics were conducted at 95% significance level. Results: G-FIX, a tooth splinting resin, showed similar shear bonding strength when additional adhesive resins were used when material was applied after only acid etching, and LightFix showed the highest shear bonding strength when additional adhesive resins were used after the acid etching. In addition, both G-FIX and LightFix showed the lowest shear bond strength when only self-etching adhesive was applied without additional acid etching. Verification of interactions observed interconnection between resins and surface treatment methods. Most of the mixed failure was observed in all counties. Conclusion: When using G-FIX and LightFix, which are tooth-splinting materials, it is considered that sufficient adhesion will be achieved even after applying only acid etching as instructed by the manufacturer.

Evidence-based management of isolated dentoalveolar fractures: a systematic review

  • Samriddhi Burman;Babu Lal;Ragavi Alagarsamy;Jitendra Kumar;Ankush Ankush;Anshul J. Rai;Md Yunus
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.3
    • /
    • pp.123-133
    • /
    • 2024
  • Dentoalveolar (DA) trauma, which can involve tooth, alveolar bone, and surrounding soft tissues, is a significant dentofacial emergency. In emergency settings, physicians might lack comprehensive knowledge of timely procedures, causing delays for specialist referral. This systematic review assesses the literature on isolated DA fractures, emphasizing intervention timing and splinting techniques and duration in both children and adults. This systematic review adhered to PRISMA guidelines and involved a thorough search across PubMed, Google Scholar, Semantic Scholar, and the Cochrane Library from January 1980 to December 2022. Inclusion and exclusion criteria guided study selection, with data extraction and analysis centered on demographics, etiology, injury site, diagnostics, treatment timelines, and outcomes in pediatric (2-12 years) and adult (>12 years) populations. This review analyzed 26 studies, categorized by age into pediatrics (2-12 years) and adults (>12 years). Falls were a common etiology, primarily affecting the anterior maxilla. Immediate management involved replantation, repositioning, and splinting within 24 hours (pediatric) or 48 hours (adult). Composite resin-bonded splints were common. Endodontic treatment was done within a timeframe of 3 days to 12 weeks for children and 2-12 weeks for adults. Tailored management based on patient age, tooth development stage, time elapsed, and resource availability is essential.

FINITE ELEMENT ANALYSIS OF STRESS PATTERNS ON PERIODONTIUM OF SPLINTED ABUTMENTSFOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (후방연장 국소의치에서 지대치의 splinting에 따른 치주조직의 응력 변화에 관한 유한요소법적 연구)

  • Hwang, Jae-Woong;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.241-268
    • /
    • 1995
  • Splint therapy, the immobilization of teeth, has been done for patient's masticatory comforts and an adjunctive aid in periodontal therapy. Mandibular premolars are frequently splinted in many distal extension removable partial denture cases. But splinting is an extensive restoration that may not be conservative of tooth structure and may prove to be quite costly to the patient. The two dimensional finite element analysis method was used to determine the magnitude and mode of distribution of the stresses of the periodontal ligament and supporting alveolar bone when abutments with different periodontal supports were splinted and distal-extension removable partial denture was subjected to different loading schemes. The results were as follows : 1. When abutments were splinted, stresses moved from apico-distal to apico-mesial of terminal abutment on a vertical force and from disto-alveolar crest to apex on a distally directed force. But stresses were generally diminished on a mesially directed force. 2. As vertical bone loss was proceeding, most of stresses were transmitted to residual ridge and the rest of stresses were concentrated on apex of distal abutment. But these apical stresses were minimized when abutments were splinted. 3. As mesially inclined bone loss was proceeding, it seemed to be dangerous that many stresses were concentrated on the distal alveolar crest, especially in the distally directed load case. Abutments splinting decreased the alveolar crestal stresses but not enough. 4. For all vertical stresses were effectively decreased on splinting, stresses were concentrated as highly on apico-mesial area of distal abutment in distally directed load cases as the distal inclination of bone level was severe. 5. The directions and magnitudes of abutment movements were decreased with teeth splinting.

  • PDF

Color quality evaluation of composite resins used for splinting teeth (동요치 고정에 사용되는 복합레진의 색품질 평가)

  • Jung, Ji-Hye;Cheon, Kyeong Jun;Oh, Yonghui;Chang, Hoon-Sang
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.995-1002
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the color stability of composite resins used for splinting teeth by comparing a self-cure resin cement (Superbond C&B, SB), a flowable composite resin (G-aenial Universal Flo A2, GU), and a composite resin exclusively used for splinting teeth (G-Fix, GF) before and after aging in NaOCl. Methods: Resin samples were fabricated to a size of 2 mm thickness and 8.5 mm diameter and light-cured with an LED light curing unit (G-Light, n = 12). Immediately after fabrication, CIE L*a*b* values of the resin samples were measured with a spectrophotometer (CM-5) as baseline. Then, the resin samples were immersed in 5% NaOCl at $60^{\circ}C$ and the color was measured after 23 hours every day for 4 days. Data were analyzed with one-way ANOVA followed by Duncan post hoc test (p<0.05), and color differences (${\Delta}E$) of resin samples before and after NaOCl aging were also calculated. Results: For SB, there were no changes in L* and a* values but changes were observed in b* values. For GU, there were no changes in L* and b* values but in a* values. For GF, changes were observed in L*, a*, and b* values. All resin samples showed highest ${\Delta}E$ between baseline and the 1st day of NaOCl immersion. ${\Delta}E$ of SB, GU, and GF was 4.6 - 5.8, 4.9 - 7.9, and 9.9 - 16.9, respectively. GF showed highest color change during NaOCl aging. Conclusion: The results of this color quality evaluation showed that the composite resin exclusively used for splinting teeth might be more vulnerable to color change during intraoral service.