• Title/Summary/Keyword: Tooth Profile

Search Result 237, Processing Time 0.021 seconds

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

  • Lee, Jeong-Ho;Kim, Mi-Ja;Seok, Chang-In;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.378-385
    • /
    • 2004
  • The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography 40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1. canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30. For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section. canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained: 1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference. 2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level. there was a statistically significant difference. 3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

Long-term stability after multidisciplinary treatment involving maxillary distraction osteogenesis, and sagittal split ramus osteotomy for unilateral cleft lip and palate with severe occlusal collapse and gingival recession: A case report

  • Kokai, Satoshi;Fukuyama, Eiji;Omura, Susumu;Kimizuka, Sachiko;Yonemitsu, Ikuo;Fujita, Koichi;Ono, Takashi
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.59-69
    • /
    • 2019
  • In this report, we describe a case involving a 34-year-old woman who showed good treatment outcomes with long-term stability after multidisciplinary treatment for unilateral cleft lip and palate (CLP), maxillary hypoplasia, severe maxillary arch constriction, severe occlusal collapse, and gingival recession. A comprehensive treatment approach was developed with maximum consideration of strong scar constriction and gingival recession; it included minimum maxillary arch expansion, maxillary advancement by distraction osteogenesis using an internal distraction device, and mandibular setback using sagittal split ramus osteotomy. Her post-treatment records demonstrated a balanced facial profile and occlusion with improved facial symmetry. The patient's profile was dramatically improved, with reduced upper lip retrusion and lower lip protrusion as a result of the maxillary advancement and mandibular setback, respectively. Although gingival recession showed a slight increase, tooth mobility was within the normal physiological range. No tooth hyperesthesia was observed after treatment. There was negligible osseous relapse, and the occlusion remained stable after 5 years of post-treatment retention. Our findings suggest that such multidisciplinary approaches for the treatment of CLP with gingival recession and occlusal collapse help in improving occlusion and facial esthetics without the need for prostheses such as dental implants or bridges; in addition, the results show long-term post-treatment stability.

Relationship among oral health perception, oral health practices, and health-promoting lifestyle in soldiers (일부 군인들의 구강건강 인식 및 실천도와 건강증진 생활양식과의 관계)

  • Park, Chung-Soon;Han, Ye-Seul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.6
    • /
    • pp.947-956
    • /
    • 2018
  • Objectives: The purpose of this study was to establish a relationship among oral health perception, practicality, and the health-promoting lifestyle profile (HPLP) of soldiers, to finalize the oral health education content to be offered to military personnel under military service and explore remedial measures. Methods: The subjects included military soldiers older than 19 years of age in the Chungnam province. The study instrument was a structured questionnaire evaluating the general characteristics, HPLP, oral health perception, and oral health practice. Data were analyzed using one way analysis of variance (ANOVA), Kruskal-Wallis ANOVA, Pearson correlation, and multiple regression analysis. Results: The HPLP evaluation of the soldiers was 3.39, and the group with the higher HPLP level showed better oral health recognition and oral health practice, with a statistically significant difference. There were differences in oral health perception, tooth brushing practice, and oral health education interest depending on the level of education and stratum of the soldier. The higher the soldier's HPLP, the higher were the oral health perception and oral health practice. The factors affecting the HPLP were oral health perception, tooth brushing practice, and interest in oral health education. Conclusions: After the military discharge, it is necessary to devise ways that will enhance oral health perception and practices that promote good oral health and lifestyle.

Investigation about Esthetic Appreciation for the Esthetic Prosthesis (심미보철(審美補綴) 제작(製作)에 관계(關係)되는 심미적(審美的) 요소(要素)에 관(關)한 연구(硏究))

  • Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.95-115
    • /
    • 1996
  • The esthetic factor for the esthetic prosthesis were studied on 300 persons. The praaticipants were 150 students registered under the Deparment of Dental Laboratoy Technology, Jisan Junior College at the present day of June, 1995 and their mothers. The results were as follows; 1. The number of persons with 28 teeth in their oralcatity was highest(P<0.01). They complained that they have only 28 teeth bacaues of the loss(deficiency) fo teeth due to their impacted teeth and dental caries. 2. The presons with feelings of dissatisfaction were large in number(P<0.01). They were dissatisfied with an abnormal tooth form(33.5%), tooth position(31.7%), tooth color(31.1%), and tooth size(3.7%) in order(P<0.01). 3. In their facial form, the most numerous were men with square form and women with ovoid form(P<0.01). Among the whloe number fo facial forms it appeared to decresae in the order of ovoied(41.8%), square(32.7%), square+tapered(20.5%), and tapered form(5%)(P<0.01). In a profile form, the most numerous were men with A form and women with B. Among the whole participants the most numerous were persons with B form and persons with A and C form were next in oder of numbers(P<0.01). 4. In discoloration of teeth, the most numerous were persons who have no discoloration. 5. In the esthetic recovery of anterior prosthesis the color matching of proximal teeth was not correct, but the outline of proximal teeth was to be reproduced correctly. 6. In the diastema of teeth, the number of persons who have no diastema was higher than that of persons who have a disatema(P<0.01) Among the persons who have diastema the most numerous were persons who have a diastema, and next were 2, 4, 3 and 5 diastemas in order. 7. In a meeting point of the midline of the body and the tooth the number of person hanving a meeting point was higher than that of persons who did not fit each other(P<0.01). The bias direction of midline teeth appeared to be affected by chewing direction, prosthesis location, and posterior location. 8. The length and width of teeth in the tooth size were suitable(P<0.01). The number of persons who have central teeth longer than lateral teeth was high(P<0.0). 9. In the results of smile analysis, the line form connected with incisal edge of upper canine were parallel(P<0.01). When smile the location fo upper lips should be in accord with the central area of teeth(P<0.01) and lower lip should be atteched to the edge of anterior teeth in order to be esthetic. 10. Among the number of upper teeth we can see the most numerous were 8 teeth and next were 10, 6 and 12 in order.

  • PDF

Immediate Autogenous Fresh Demineralized Tooth (Auto-FDT) Graft for Alveolar Bone Reconstruction (즉시 탈회 치아이식재를 사용한 치조골 재건술)

  • Lee, Eun-Young
    • The Journal of the Korean dental association
    • /
    • v.54 no.5
    • /
    • pp.348-355
    • /
    • 2016
  • Ideal autogenous or allogenic bone graft materials should provide 1) stabilization of blood clot, 2) scaffolds for cellular proliferation and differentiation, 3) release of osteogenic growth factors, 4) appropriate resorption profile for remodeling of new bone. Teeth, especially dentin, mostly contain hydroxyapatite and type I collagen which are similar to bone, and could be valuable graft material. Clinically teeth are used as calcined or demineralized forms. Demineralized form of dentin can be more effective as a graft material. But a conventional decalcification method takes time and long treatment time may give negative effects to various osteogenic proteins in dentin. Author used a new clinical method to prepare autogenous teeth, which could be grafted into the removal defects immediately after extraction using vacuum ultrasonic system. The process could be finished within two hours regardless of the form (powder, chip or block). Teeth were processed to graft materials in block, chip, or powder types immediately after extraction. It took 120 minutes to prepare block types and 40 minutes to prepare powder. Clinical cases did not show any adverse response and the healing was favorable. Rapid preparation of autogenous teeth with the vacuum ultrasonic system could make the immediate one-day extraction and graft possible.

  • PDF

Analysis of the Reduction Gear in Electric Agricultural Vehicle

  • Choi, Won-Sik;Kwon, Soon-Goo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.4
    • /
    • pp.159-165
    • /
    • 2018
  • In electric agricultural machine a reduction gear is needed to convert the high speed rotation motion generated by DC motor to lower speed rotation motion used by the vehicle. The reduction gear consists of several spur gears. Spur gears are the most easily visualized gears that transmit motion between two parallel shafts and easy to produce. The modelling and simulation of spur gears in DC motor reduction gear is important to predict the actual motion behaviour. A pair of spur gear tooth in action is generally subjected to two types of cyclic stress: contact stress and bending stress. The stress may not attain their maximum values at the same point of contact fatigue. These types of failure can be minimized by analysis of the problem during the design stage and creating proper tooth surface profile with proper manufacturing methods. To improve its life expectation in this study modal and stress analysis of reduction gear is simulated using ANSYS workbench based on finite element method (FEM). The modal analysis was done to understand reduction gear deformation behaviour when vibration occurs. FEM static stress analysis is also simulated on reduction gear to simulate the gear teeth bending stress and contact stress behaviour.

Wear and Operation Characteristics of Acetal and Nylon Pinion Against Steel Gear (아세탈과 나일론피니언의 마멸 및 운전특성에 관한 고찰)

  • Kim, Chung-Hyeon;Lee, Seong-Cheol;An, Hyo-Seok;Jeong, Tae-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.9 s.180
    • /
    • pp.2387-2396
    • /
    • 2000
  • Wear and operation characteristics of Nylon and Acetal pinion against steel gear were studied to gain a better understanding of their tribological and mechanical behavior. Tests were conducted with power circulating gear test rig under unlubricated conditions. Specific wear rates were measured as a function of applied load and total revolution. The worn tooth surfaces were examined with a profile projector and camera. Nylon pinion showed lower specific wear rates than Acetal pinion, but it revealed breakage at high load. Principal wear depths were developed at tooth tip and below the pitch line of pinion. Life estimation for the Nylon pinion was made by taking into account steel gear equivalent Hertz stress and average sliding velocity. The dominant wear mechanisms were adhesion and abrasion.

Mechanical Properties of Surface Densified PM Gears (표면치밀화 기술에 의해 제조된 소결 기어의 기계적 특성)

  • Kim, Ki-Jung;Kim, Ki-Bum;Lee, Doo-Hwan;Park, Jong-Kwan;Jeong, Dong-Guk
    • Journal of Powder Materials
    • /
    • v.19 no.3
    • /
    • pp.189-195
    • /
    • 2012
  • A novel PM (powder metallurgy) steel for automotive power-train gear components was developed to reduce manufacturing cost, while meeting application requirements. The high-density PM steel was manufactured by mixing using special Cr-Mo atomized iron powders, high-pressure compaction, and sintering. Tensile strength, charpy impact, bending fatigue, and contact fatigue tests for the PM steel were carried out and compared to conventional forged steel. Pinion gears for auto-transmission were also manufactured by helical pressing, sintering, and surface densification process. In order to evaluate the durability of the PM parts, auto-transmission durability tests were performed using dynamometer tests. Results showed that the PM steel fulfilled the requirements for pinion gears indicating suitable tensile, bending fatigue, contact fatigue strengths and improved gear tooth profile. The PM gears also showed good performance during the transmission durability tests. As a result, the PM gears showed significant potential to replace the conventional forged steel gears manufactured by tooth machining (hobbing, shaving, and grinding) processes.

Lower Incisor Extraction for Dental Camouflage (하악전치발치를 통한 교정)

  • Lee, Won-You;Lee, Young-Taek
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.661-668
    • /
    • 1997
  • There is a variation in the range of normal occlusion, and we must fit our treatment to the needs of each patient. If the upper or lower incisors are congenital)y missing, malformed, or crowded, the extraction of the incisor has some advantages over the extraction of premolars and nonextractions. The advantages are 1)simple mechanics, 2)reduced treatment time, 3)less relapse tendency, and 4)fewer facial profile changes. In order to decide which incisor should be extracted, we must consider certain factors 1)discrepancies in anterior arch length, 2)anterior tooth ratio, 3)periodontal and tooth health condition, and 4)the relationship between the upper and lower midline. Diagnostic set-up can be helpful to plan the treatment and show us the post treatment result.

  • PDF

A COMPARATIVE STUDY ON THE WEAR RESISTANCE OF POLYMERIC VENEERING MATERIALS (치관 전장용 레진의 내마모성에 대한 비교연구)

  • Youn, Soo-Sun;Lee, Sun-Hyung;Yang, Jae-Ho;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.33-43
    • /
    • 1986
  • The purpose of this study was to compare the wear resistance of heat pressure-cured microcomposite(SR-Isosit-N), photo-cured microcomposite(Dentalcolor), unfilled heat-cured resin(Thermojel) and that of human enmel. Specimens were made with specially designed die and finally polished with #3,000 diamond paste. After 100,000 strokes of tooth brushing at electric tooth-brushing machine, mean thickness loss of each specimen was measured by using surface profile and integration. The results were as follows 1. Mean thickness loss were $84.3{\pm}27.3{\mu}m$ in unfiled heat-cured resin, $9.4{\pm}2.5{\mu}m$ in photocured microcomposite, $7.6{\pm}2.1{\mu}m$ in heat.pressure-cured microcomposite and $0.97{\pm}0.42{\mu}m$ in enamel. 2. Heat.pressure-cured microcomposite and photo-cured microcomposite had no difference in mean thickness loss(p>0.05). 3. Unfilled resin and microcomposite had much differences in mean thickness loss (p<0.005). 4. ha resins used in this experiment had too much mean thickness loss as compared with enamel (p<0.005).

  • PDF