• 제목/요약/키워드: Tooth Fracture

검색결과 335건 처리시간 0.024초

하악골 골절선상에 위치한 치아의 예후에 관한 연구 (THE PROGNOSIS OF THE TEETH IN THE MANDIBULAR FRACTURE LINES)

  • 송재철;장익준;진병로
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.507-513
    • /
    • 2000
  • Objective : The purpose of this study is to evaluate the vitality of the teeth in and adjacent to the mandibular fracture line according to variable conditions of fracture and to establish the protocol of treatment of fracture line teeth. Materials and Methods : The vitality of 97 teeth in fracture line and 104 teeth adjacent to fracture line of 52 patients were invested preoperatively. Of these, 66 teeth in fracture line and 72 teeth adjacent to fracture line were monitored at least 6 months after operation. An electric pulp tester was used to measure pulpal response. The relationships between the vitality of teeth in variable time(preoperation, immediate post-operation; within 1 week after operation, and 6 months after operation) and variable conditions of fracture(horizontal, vertical gap of fracture line, the number of fracture line)were evaluated statistically. Result : The vitality of fracture line teeth in the 6 months after operation statistically differed by the vertical gap of fracture line and the number of fracture line. The vitality of fracture line adjacent teeth in the immediate post-operation only statistically differed by the vertical gap of fracture line. There were statistically differences between preoperative EPT value and vitality of fracture line teeth on 6 months after operation. There were 5 cases of complications including periapical and periodontal abscess. Of these, only one tooth was extracted and the others were well treated with endodontic treatment and subgingival curettage. Conclusion : It is recommended to retain teeth and to monitor the vitality of teeth in and adjacent to fracture line, unless there is an absolute indication for extraction.

  • PDF

섬유강화 포스트와 금속주조 포스트의 파절강도 밋 파절양상의 비교 (COMPARISON OF FRACTURE STRENGTH AND PATTERN OF ENDODONTICALLY TREATED TEETH RESTORED WITH FIBER POSTS AND METAL CAST POST)

  • 김미경;김석규
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.535-543
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.

섬유강화형 포스트를 이용한 치관-치근 파절의 치료: 증례 보고 (TREATMENT OF CROWN-ROOT FRACTURE USING FIBER-REINFORCED POST: A CASE STUDY)

  • 임화신;라지영;이광희;안소연;김윤희;금기석;이상봉
    • 대한소아치과학회지
    • /
    • 제39권1호
    • /
    • pp.58-65
    • /
    • 2012
  • 치관-치근 파절은 법랑질, 상아질, 백악질이 모두 포함된 치아의 파절로, 파절선이 대부분 절단연이나 순측의 변연부 치은에서 구개측 치은열구 하방으로 사선으로 진행된다. 파절선의 위치가 치은 연상이라면 파절편의 제거 및 치은연상 수복을 시행하고, 치은 연하라면 파절면의 외과적 노출술, 교정적 정출술, 외과적 정출술을 이용한 치아의 수복이 이루어진다. 그 외에 섬유 강화형 포스트를 삽입하여 치관 수복물의 유지력을 높이고, 레진 접착 시스템을 사용하여 치관 파절편을 재부착함으로써 생물학적으로 최소한으로 침습적인 치료를 하는 방법도 있다. 만약 파절의 정도가 치은 연하로 깊은 경우 발치나 치관절제술을 이용한 치근의 유지 등을 고려할 수 있다. 본 증례는 치관-치근파절로 내원한 12세 환아로 섬유강화형 포스트를 사용하여 치관 파절편 재부착을 시행하였으며 양호한 경과를 보여 이를 보고하는 바이다.

외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료 (Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion)

  • 이소진;김유진;박영범;조규성;정문규
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.204-209
    • /
    • 2012
  • 치은연 하방에 치아 우식증이나 치아 파절이 발생했을 때, 치아를 탈구시켜 즉시 정출시키는 외과적 정출술을 이용한 치관 연장술은 자연치를 보존하고 추가적인 치주적 수술 없이 단기간에 심미적인 보철 치료를 가능하게 한다. 본 환자는 16세 남환으로 본원 보존과로부터 상악 좌측 중절치의 심미 수복을 위해 본원 보철과로 의뢰되었다. 상악 좌측 중절치는 근관치료가 되어 있었으며 치관-치근 파절로 인해 협측 치관 길이는 4mm였으며 구개측 판막을 열었을 때 근심 구개측 치경부 파절 범위는 치은 하방 3-4mm에 위치하였다. 외과적 정출술을 통한 치관연장술을 시행하였으며 경과 관찰 및 임시 치아의 단계를 거쳐 3개월 후에 전부 도재관으로 수복하여 만족할 만한 임상결과를 얻을 수 있었다.

초기 영구 전치 파절시의 치아 재부착술의 임상 증례 (CLINICAL EFFORTS FOR TECHNICAL IMPROVEMENT IN TOOTH FRAGMENTATION)

  • 최성철;이긍호;최영철
    • 대한소아치과학회지
    • /
    • 제29권1호
    • /
    • pp.125-131
    • /
    • 2002
  • 본 증례는 경희대학교 치과대학병원 소아치과학교실에 상악 중절치의 치수노출을 동반한 외상을 주소로 내원한 아동의 치험례이다. 증례 1은 미성숙 치근을 가지는 만 8세의 남아로 치아의 치수 노출에 따른 수산화칼슘 치수절단술을 이용한 치근단 형성술을 시행한 후 치아 재부착술을 시행한 증례이며, 증례 2는 점상의 치수노출을 보이는 미성숙 영구 중절치를 직접 치수 복조 추 석회화 층을 형성하는 기간동안 레진을 이용하여 유지한 후 치아 재부착술을 시행하였고 증례 3은 치은 연하로 치경부 파절을 보이는 만 12세의 환아로 신경치료 후 골 삭제술과 골 성형술을 동반한 판막술을 시행하여 carbon fiber post를 이용한 치아 재부착술을 시행한 증례이다 이상의 증례를 통하여 치아 재부착술을 성공적으로 시행하였으며 심미적으로 양호한 결과를 얻었기에 보고하는 바이다.

  • PDF

Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures

  • Shim, Hye Won;Yang, Byoung-Eun
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.423-430
    • /
    • 2015
  • PURPOSE. To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth $Ankylos^{(R)}$ implants. MATERIALS AND METHODS. This was a retrospective clinical study that analyzed 450 single $Ankylos^{(R)}$ implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position. RESULTS. The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05). CONCLUSION. The $Ankylos^{(R)}$ implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.

치은 연하로 파절된 상악 전치부의 수복 (Restoration of Subgingivally Fractured Upper Incisor)

  • 김자영;이홍석;안승근;박주미;송광엽;박찬운
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.301-307
    • /
    • 2006
  • The subgingival fracture near the alveolar bone is difficult to treat. This fractured tooth will be treated by many methods. First approach is to preserve the fractured tooth. Periodontal surgery has been used to lengthen the clinical crown, thereby allowing the tooth to be restored. Another method is erupting the tooth with orthodontic eruption (forced eruption) or surgical extrusion. Second approach is the restoration after extraction of the subgingivally fractured tooth. This is restorative with conventional fixed partial denture or implant. This article presents the variable restorative approach of subgingivally fractured upper incisor.

외상 후 오랜 시간 지체된 탈락 치아 재식술 시행 시 근관 통한 배농: 증례보고 (Endodontic Drainage in Delayed Replantation after Prolonged Extra-alveolar Period of the Avulsed Teeth: Report of a Case)

  • 유재하;김종배;손정석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권4호
    • /
    • pp.280-285
    • /
    • 2012
  • From the standpoint of general guidelines of a dentist, the following conditions should be considered before replanting a permanent tooth. The avulsed tooth should be without advanced periodontal disease. The alveolar socket should be reasonably intact in order to provide a seat for the avulsed tooth. The extra-alveolar period should be considered, i.e. periods exceeding. 2 hours are usually associated with marked root resorption. But, the above mentioned regulations are often difficult to keep in the actual situation of the medical emergency room, owing it to the delay of primary medical care in multiple trauma patients. The successful cases have been reported with minimal root resorption in the long-term periods, in spite of extra-alveolar periods of several hours and combined alveolar bone fracture. This is a case report regarding the effect of endodontic drainage in delayed replantation after a prolonged extra-alveolar period of the avulsed teeth with alveolar bone fracture.

Pterygopaltine fossa로 전위된 상악 매복지치 발치 치험례 (A CASE REPORT: THE SURGICAL REMOVAL OF THE DISPLACED MAXILLARY THIRD MOLAR INTO THE PTERYGOPALTINE FOSSA BY THE MIDPALTAL AND TRANSPHARYNGEAL APPROACH)

  • 장현석;장명진;김용관
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제16권2호
    • /
    • pp.167-170
    • /
    • 1994
  • The surgical removal of the wisdom teeth is obligate when forceps extraction fails or when the wisdom teeth are impacted. The surgical removal of impacted maxillary third molars is a commonly performed procedure usually associated with few complications & little morbidity. The most frequent complications are tooth root fracture, maxillary tuberosity fracture, tooth displacement into the maxillary sinus & oroantral fistula formation. A rarely reported complication is the displacement of a tooth into the infratemporal fossa. The method of prevention of this complication is by the placement of either a finger or periosteal elevator posterior to the tooth during extraction. To remove the displaced upper third molar is very difficult & has many complications, e.g., persistent bleeding & nerve damage. When the wisdom teeth is displaced, it is initially necessary to gain access to bone by developing a mucoperiosteal path of delivery is developed by additional bone removal or, preferably planned sectioning of the tooth. There are many approaching techniques to remove the displaced upper third molar. This following report describes the surgical technique of displaced upper third molar in the pterygopalatine fassa by the midpalatal &transpharyngeal approach.

  • PDF

헬리컬기어 제조공정에 따른 특성 비교 -단조품과 기계가공품- (Properties of a Helical Gear Due to the Manufacturing Process - Forged versus Machined Product)

  • 정현철;강범수;이일환;최석탁;신상종;강성훈;이영선
    • 소성∙가공
    • /
    • 제21권1호
    • /
    • pp.67-74
    • /
    • 2012
  • Although high productivity is possible, cold forged helical gears have not been widely used due to difficulty in achieving mechanical properties as well as dimensional accuracy of the product. Confidence in the gear characteristics also is very important in heavy-duty gear applications. Therefore, the properties of forged gears must be compared to the properties of conventional machined gears. The properties might be different due to the different fabrication processes. In this study, machined and forged products both before and after heat-treated have been compared by measuring the residual stress and involute curve of the tooth. Characteristics of hardness and microstructure were also compared. Additionally, tooth fracture strength was compared for the heat-treated products. Moreover, the tooth strength and the fracture pattern were compared between the machined and forged gears. The forged gear showed decreased changes in residual stress and decreased changes in dimensions when compared to the machined gear before and after heat treatment. The forged gear was over 10% better than the machined gear in tooth strength.