• Title/Summary/Keyword: Tone quality

Search Result 189, Processing Time 0.032 seconds

Sound Quality Enhancement by using the Single Core Exciter in OLED Panel

  • Lee, Sungtae;Park, Kwanho;Park, Hyungwoo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.2
    • /
    • pp.871-888
    • /
    • 2020
  • With the development of display engineering and technology, the screen and sound quality of information devices such as TVs are improving. The screen used LEDs via LCD and PDP and a large flat panel in the early CRT to create super-high resolution. The sound is improved by directly vibrating a thin and simple panel, such as an OLED. In our previous study, the exciter speaker was attached to the rear of the OLED panel to be used as the diaphragm of the speaker, and the sound quality was as good as that of the TV using the existing dynamic speaker. This method supplied the viewer with the direct sound coming from the panel, delivering clear sound, and the sound and image came from the same location, thus giving the viewer high immersion and maximizing the effect of information transfer. OLED exciter speakers, however, have a special directivity, which tends to slightly attenuate the tone at the very center of the screen. This study improves the sound quality by improving the structure of the exciter speaker and the radiated sound of the flat panel display. A 2-in-1 Exciter is made into a single core to improve the speaker's radiation pattern.

A Development of a Medical Information Transmisson System in Moving Picture Form(MedMpeg)

  • Choi, Jong U.;Cho, Hune
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.2 no.1
    • /
    • pp.131-139
    • /
    • 1998
  • With the rapid development of communication technology and widespread uses of internet service, utilization of internet-based medical information systems which transmitts moving pictures of medical objects is becoming a common practice. The internet-based medical information service prvovides richer information than conventional services such as touch-tone telephone, personal computers e-mails, or pagers, because "a picture is worth a thousand words". However, the systems passively transmits moving pictures of the medical objects to the users, and thus the system cannot intelligently adjust itself to provide better service. As the tradeoff exists between transmission speed and quality of the image, there is a need that moving pictures be analyzed to adjust the trnasmission speed and image quality. When very little difference between consecutive images are detected, the system can automatically increase the size of the image files, thus enhancing the quality of image. In contrast, the system should increase the number of images to send more pictorial information by sacrificing the quality of each individual image, when a significant difference is detected. In this paper an adaptive filtering technique is introduced which adjusts the quality of image and transmission speed according to a clinical situation in hospital.

  • PDF

A Personal Sound Amplification Product Compared to a Basic Hearing Aid for Speech Intelligibility in Adults with Mild-to-Moderate Sensorineural Hearing Loss

  • Choi, Ji Eun;Kim, Jinryoul;Yoon, Sung Hoon;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.91-98
    • /
    • 2020
  • Background and Objectives: This study aimed to compare functional hearing with the use of a personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineural hearing impaired listeners. Subjects and Methods: Nineteen participants with mild-to-moderate sensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) were prospectively included. No participants had prior experience with HAs or PSAPs. Audiograms, speech intelligibility in both quiet and noisy environments, speech quality, and preference were assessed in three different listening conditions: unaided, with the HA, and with the PSAP. Results: The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2, and 4 kHz compared to the unaided condition (all p<0.01). In the quiet environment, speech intelligibility was significantly improved after wearing a PSAP compared to the unaided condition (p<0.001), and this improvement was better than the result obtained with the HA. The PSAP also demonstrated similar improvement in the most comfortable levels compared to those obtained with the HA (p<0.05). However, there was no significant improvement of speech intelligibility in a noisy environment when wearing the PSAP (p=0.160). There was no significant difference in the reported speech quality produced by either device or in participant preference for the PSAP or HA. Conclusions: The current result suggests that PSAPs provide considerable benefits to speech intelligibility in a quiet environment and can be a good alternative to compensate for mild-to-moderate SNHL.

A Personal Sound Amplification Product Compared to a Basic Hearing Aid for Speech Intelligibility in Adults with Mild-to-Moderate Sensorineural Hearing Loss

  • Choi, Ji Eun;Kim, Jinryoul;Yoon, Sung Hoon;Hong, Sung Hwa;Moon, Il Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.91-98
    • /
    • 2020
  • Background and Objectives: This study aimed to compare functional hearing with the use of a personal sound amplification product (PSAP) or a basic hearing aid (HA) among sensorineural hearing impaired listeners. Subjects and Methods: Nineteen participants with mild-to-moderate sensorineural hearing loss (SNHL) (26-55 dB HL; pure-tone average, 0.5-4 kHz) were prospectively included. No participants had prior experience with HAs or PSAPs. Audiograms, speech intelligibility in both quiet and noisy environments, speech quality, and preference were assessed in three different listening conditions: unaided, with the HA, and with the PSAP. Results: The use of PSAP was associated with significant improvement in pure-tone thresholds at 1, 2, and 4 kHz compared to the unaided condition (all p<0.01). In the quiet environment, speech intelligibility was significantly improved after wearing a PSAP compared to the unaided condition (p<0.001), and this improvement was better than the result obtained with the HA. The PSAP also demonstrated similar improvement in the most comfortable levels compared to those obtained with the HA (p<0.05). However, there was no significant improvement of speech intelligibility in a noisy environment when wearing the PSAP (p=0.160). There was no significant difference in the reported speech quality produced by either device or in participant preference for the PSAP or HA. Conclusions: The current result suggests that PSAPs provide considerable benefits to speech intelligibility in a quiet environment and can be a good alternative to compensate for mild-to-moderate SNHL.

A Multi-speaker Speech Synthesis System Using X-vector (x-vector를 이용한 다화자 음성합성 시스템)

  • Jo, Min Su;Kwon, Chul Hong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.675-681
    • /
    • 2021
  • With the recent growth of the AI speaker market, the demand for speech synthesis technology that enables natural conversation with users is increasing. Therefore, there is a need for a multi-speaker speech synthesis system that can generate voices of various tones. In order to synthesize natural speech, it is required to train with a large-capacity. high-quality speech DB. However, it is very difficult in terms of recording time and cost to collect a high-quality, large-capacity speech database uttered by many speakers. Therefore, it is necessary to train the speech synthesis system using the speech DB of a very large number of speakers with a small amount of training data for each speaker, and a technique for naturally expressing the tone and rhyme of multiple speakers is required. In this paper, we propose a technology for constructing a speaker encoder by applying the deep learning-based x-vector technique used in speaker recognition technology, and synthesizing a new speaker's tone with a small amount of data through the speaker encoder. In the multi-speaker speech synthesis system, the module for synthesizing mel-spectrogram from input text is composed of Tacotron2, and the vocoder generating synthesized speech consists of WaveNet with mixture of logistic distributions applied. The x-vector extracted from the trained speaker embedding neural networks is added to Tacotron2 as an input to express the desired speaker's tone.

Performance Analysis of IMD-Reduction-based Tone Reservation Method for the Protection of Nonlinear Distortion in the OFDM Communication System (OFDM 통신 시스템에서 비선형 왜곡 방지를 위한 IMD 저감 기반의 Tone Reservation 방식의 성능 분석)

  • Byeon, Heui-Seop;Kim, Nam-Il;Kim, Young-Hoon;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.10 s.113
    • /
    • pp.943-952
    • /
    • 2006
  • The OFDM system is very good for the high data rate communication system. However, OFDM system has a high PAPR problem. This makes the OFDM signal distorted through the nonlinear HPA(High Power Amplifier). To solve this problem, generally, simple PAPR reduction methods have been considered. However, in this paper, we introduce IMD reduction method instead of PAPR. PAPR is the signal property and the IMD is signal component of the HPA output, which degrades the communication quality. So, instead of PAPR we want to use the IMD reduction method. This is to transmit a signal with the smallest distortion by considering the third order nonlinearity when the data is recovered. We use the TR method that was proposed for the PAPR reduction and we find out the BER performance of two methods. As results, we show that the IMD reduction method improves better BER performance than the PAPR reduction.

An Implementation of On-line Recording for TDX-10A Switching System (TDX-10A 온라인 녹음기능 구현방안 연구)

  • 김태원;류영일이성근
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.293-296
    • /
    • 1998
  • When the information of announcement facility is modified or added, they are recorded on a tape and then are updated manually using the cassette tape recorder at each office. But the degrade of the tone quality owing to repeated use of the tape and some recording mistakes by processing manually deteriorate the quality of service. And new services such as IN(Intelligent Network) and added functions make the announcement changed very often. Therefore the improved skill of the announcement handling is needed. This paper introduces the implementation of the TDX-10A on-line recording function of transferring voice in PCM data file and storing it in the memory of the recorded announcement facility, when message is recorded onthe fixed type of announcement facility.

  • PDF

A Study on the Effects on Melody According to an Annual Ring on Gayageum (가야금의 나이테가 선율에 미치는 영향에 관한 연구)

  • Jung, Chan-Joong;Kang, Hee-Su;Bae, Myung-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.879-880
    • /
    • 2008
  • Music can give pleasure to people according to a rhythm, and Musical instrument can make various sounds according to quality of the lumber. A string instrument makes sound by strings so it feels very soft and a brass makes to feel a high pitched tone. A gayageum makes sound by oscillation which is transferred to a resonator when a string is touched. And this sound is very soft and faint. Therefore, in this paper, we researched sound properties of gayageum according to quality of the lumber of musical instrument. As the result of researches, we found that melody is affected by the annual ring of the resonance lumber.

  • PDF

A Study on Threshold of Hearing of Sun shade Motor Sound Using Masking Effect (마스킹 효과를 이용한 선셰이드 모터음의 최소가청치 특성에 관한 연구)

  • Jo, Hyeonho;Seong, Wonchan;Kim, Seonghyeon;Park, Dongchul;Kang, Yeonjune
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.116-121
    • /
    • 2013
  • Panaroma Sun roof's sun shade motor elicits two major sounds when operating: the tonal sound and the white noises. Generally, the sound related to the sharpness contributes the most to the quality of motors' tonal sound. The primary purpose of this study was to set the loudness of the motor's objective tonal sound utilizing the masking effect by its white noises. To conduct this study, the sound made by the operating sun shade motor was categorized into two different subsets of masker and test tone to examine the masking threshold. Also, the shifts of masking threshold were observed with the varying masker loudness.

  • PDF

The Study of Tonsil Affected Voice Quality after Tonsillectomy (편도적출술로 음성변화가 올 수 있는 편도 상태에 관한 연구)

  • 안철민;정덕희
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.32-37
    • /
    • 1998
  • Tonsillectomy is the one of operation that is performed the most commonly in otolaryngology field. Many changes that include range of voice, tone, voice quality and resonance were made by tonsillectomy. Sometimes, any patients taken tonsillectomy has suffer from these voice problem after tonsillectomy. However there are less study for these problems until now. Then, we studied to find the anatomical findings that affected the voice quality when tonsillectomy was performed. We evaluated the voice in 2 groups, one is the group showed the normal pharyngeal space by using the transnasal fiberscopy, the other is group showed medially bulging tonsil at pharyngeal cavity by using same method, with perceptual evaluation, nasalance score, nasality, oral formant and nasal formant. We used the computerized speech analysis system, the nasometer and the spectrogram in the CSL program. We could not find any differences in perceptual evaluation between two groups. But objective measures were provided. Nasalance score and nasality on the nasometric analysis were increased significantly and oral formant on the spectrogram was changed singnificantly after tonsillectomy in Group 2. Authors thought medially bulging tonsil in the pharynx is able to affect the voice quality after tonsillectomy when we evaluted through the nasal cavity by the using of fiberscopy and this evaluation would be important especially in singers.

  • PDF