• Title/Summary/Keyword: Tm3+

Search Result 2,044, Processing Time 0.122 seconds

Variations on the Concentration of Dissolved Gaseous Mercury(DGM) at the Juam Reservoir, Korea (주암호의 용존가스상 수은의 농도변화 특성에 관한 연구)

  • Park, Jong-Sung;Oh, Se-Hee;Shin, Mi-Yeon;Yi, Seung-Muk;Zoh, Kyung-Duk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.667-676
    • /
    • 2006
  • The reduction of $Hg^{2+}$ in the aqueous phase results in the production of dissolved gaseous mercury(DGM), and the volatilization of DGM has been identified as an important mechanism for the loss of Hg from waterbodies to the atmosphere. Although mercury emission in the world is known to be mostly from Asia, there have been few studies of measuring DGM concentrations in lakes in Asia. In this study, DGM concentrations were measured at Juam reservoir($35^{\cir}00'N,\;127^{\circ}14'E$), Korea. The results showed that the average concentrations of DGM at the upper and down stream of the lake during summer time were $95{\pm}8\;and\;130{\pm}15$ pg/L, respectively and the concentration of total mercury(TM) at the upper and down stream was $2.1{\pm}0.7,\;1.7{\pm}0.3$ ng/L respectively. Average DGM concentration during summer time($101{\pm}14pg/L$) was approximately 5.5 times higher than that during fall($18{\pm}0.1pg/L$). The DGM concentrations ai the midstream decreased from 32 to 13.7 pg/L during rain event, while the TM concentrations increased from 2.2 ng/L to 2.7 ng/L indicating the deposition of mercury from the atmosphere. Also, the diurnal patterns between DGM concentrations and UV intensities were observed. Water temperatures and DOC concentrations were significantly related to DGM concentrations, while TM concentrations were negatively related to DGM concentrations(p<0.0001). Comparing with the study of Dill et al.,(2006) the average concentrations of DGM $(109{\pm}15pg/L)\;and\;TM(2.2{\pm} 0.4ng/L)$ at Juam reservoir were approximately 3 and 2.2 times higher than those measured in other lakes(DGM: $38{\pm}16pg/L$, TM: $1.0{\pm}1.2ng/L$).

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

An Analysis of the Twisting and Bending Extrusion Process of the Product with the Rectangular Section by the $ DEFORM^{TM}$-3D (사각단면을 가진 압출제품의 비틀림굽힘 압출가공법에 대한$ DEFORM^{TM}$-3D 해석)

  • 윤선홍
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.115-118
    • /
    • 1999
  • The twisting and bending extrusion process is developed by the $DEFORM^TM$-3D. Because the rectangular section of the extruded product has the symmetry line of cross-section area, the twisting and the bending of extruded product has not occurred. The product with the rectangular section is applied to the twisting and bending extrusion process through the twisted die surface and eccentricity die section. It is shown that the twisting of extruded product is caused by the twisted die surfaces and the bending of extruded product is causd by the eccentricity between the die section. The results by the analysis show that the twisting angle and the curvature of extruded products increases by the die twisting angle, the eccentricity, but decreases by the die length, and friction condition

  • PDF

Molecular Modeling of the Subtype Dopamine Receptor-ligand Interactions

  • Baek, Minkyung;Shin, Woong-Hee
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.13-24
    • /
    • 2013
  • Dopamine agonists and antagonists and its receptor play a critical role in the information transfer in the nervous system, and dopamine receptor-ligands interactions are deeply related to Parkinson's disease, schizophrenia and some other mental diseases. However, the only experimental 3D structure available for dopamine receptors is human D3 dopamine receptor. Therefore, it is important to create model of subtype dopamine receptor-ligands interactions. We report here the 3D structures of the human D1 and D2 dopamine receptor predicted by using GalaxyTBM, and its predicted binding site determined by using GalaxyDock. The highly conserved Asp on TM 3 and Phe on TM 6 have critical role in ligand binding. Also, highly conserved serines on TM 5 are essential for binding agonists and some kinds of antagonists. We identify differences between binding sites of agonists and antagonists of human D1 and D2 dopamine receptor, and find the reasons of selective binding of antagonists.

  • PDF

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

Post-thawed Preimplantation Development and Production of Offsprings after Vitrification using Taxol $^{TM}$ a Cytoskeleton Stabilizer (마우스 성숙난자의 유리화 동결 중 Cytoskeleton Stabilizer, Taxol의 처리 후 배발달률과 산자의 생산)

  • 박성은;박이석;정형민
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.239-243
    • /
    • 2001
  • Selection of oocyte cryopreservation method is a prerequisite factor for developing an effective bank system. Compared with slow freezing method, the vitrification has various advantages such as avoiding intracellular ice crustal formation. In our previous, we attempted to employ a vitrification method using ethylene glycol and an electron microscope grid for cryopreservation of mouse oocytes. However, A high incidence of spindle and chromosome abnormalities was detected in thawed oocytes after vitrification. We examined whether the addition of a cystoskeleton stabilizer Taxol $^{TM}$, to the vitrification solution could promote the post-thawed survival and subsequent development of stored oocytes. More oocytes developed to the 4-cell (44.7% vs. 69.7%), 8-cell (31.8% vs. 64.2%), morula (24.7% vs. 54.3%), and blastocyst (20.3% vs. 49.2%) stages after the addition of Taxol$^{TM}$ to the cryoprotectant than after no addition. 21 and 26 mouse pups were born after transfer of blastocyst derived from oocytes vitrified without and with Taxol. The addition of Taxol to vitrification solution greatly promoted post-thaw preimplantation development of ICR morose oocytes.tes.

  • PDF

Blade Development and Test of WinDS$3000^{TM}$ System (WinDS$3000^{TM}$ 시스템의 블레이드 개발 및 시험)

  • Lee, Sang-Il;Lee, Kyeong-Woo;Joo, Wan-Don;Lee, Ki-Hak;Park, Jong-Po
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.448-448
    • /
    • 2009
  • A new blade has been developed to apply to Doosan 3MW offshore wind turbine named as WinDS3000TM. The 3MW blade has been designed by the concept of slim external shape and optimized structure. High-performance glass fiber reinforced epoxy composites were used as the main material of the blade. The blade was manufactured using vacuum infusion process in order to increase the fiber volume fraction and to reduce micro-porosities. The blade has successfully passed the full-scale blade static test for certification. During the test, micro-failure signal and strain change of the blade were measured using acoustic emission sensors and strain gages. The blade has robust structure and weighs lighter compared to conventional blade since the new blade was designed by optimization process. The 3MW blade will be commercially applied to WinDS$3000^{TM}$ in 2010.

  • PDF

Investigation of Dietary Lysophospholipid (LipidolTM) to Improve Nutrients Availability of Diet with In Vitro Rumen Microbial Fermentation Test

  • Cho, Sangbuem;Kim, Dong Hyun;Hwang, Il Hwan;Choi, Nag-Jin
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.33 no.3
    • /
    • pp.206-212
    • /
    • 2013
  • This study was conducted to investigate the effect of biological membrane transfer modifier, lysophospholipd (LPLs) on the parameters from in vitro rumen simulated fermentation. Commercially available LPLs product (Lipidol$^{TM}$) was supplemented into experimental diets which consisted of orchard grass and concentrate diet (60:40) in different levels (0.1%, 0.3% and 0.5%). Then in vitro rumen simulated fermentation was performed. Although, a declining trend of pH was found in treatments, all pH values were detected in a range relevant to normal rumen fermentation. Gas production, ammonia nitrogen and total VFA production were greatly influenced by the supplementation of LPLs. All parameters were increased along with increased levels of LPLs in diet. As a result, 0.1% of Lipidol$^{TM}$ is recommended based on the determined in vitro rumen fermentative parameters in this study.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

The analysis of differences of mean basin precipitation between TM and radar using correlation with basin characteristics and rainfall patterns (TM과 레이더를 이용한 유역평균강수량 차이와 유역특성 및 강우형태와의 상관성)

  • Park, Jaeheyon;Sung, Janghyun;Cho, Yohan;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.7
    • /
    • pp.469-480
    • /
    • 2020
  • This study analyzed the differences of mean basin precipitation between TM and radar based on the 51 standard basins in Han river and Nakdong river when large scale of heavy rains occurred in 2018. The result shows that the differences between radar and TM are -65.05 ~ 26.09% and -82.00 ~ 3.80% for accumulated and 10 min. maximum mean basin precipitation, respectively. The correlation analysis between the differences of estimated mean basin precipitation and basin characteristics such as average altitude of basin, area of basin, and shape factor of basin presents that there is no clear correlation between them. And the differences of point precipitation also shows the similar tendency with those of mean basin precipitation. In order to find out the correlation between them and meteorological conditions such as rainfall patterns, the reflectivity of radars according to the observation angles is analyzed at the selected basins, and then it is found that the differences of mean basin precipitation between TM and radar is more dominated by the meteorological conditions than by the topographic conditions such as basin characteristics.