• 제목/요약/키워드: Tissue paper

검색결과 659건 처리시간 0.032초

인접치아가 임플란트 치은연하 세균총의 분포에 미치는 영향 (The influence of adjacent tooth to the microbiology of implant sulcus)

  • 이동영;이만섭;권영혁;박준봉;허익;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.563-575
    • /
    • 2005
  • The aim of present study is to evaluate the influence of adjacent tooth to the microbiology of clinically healthy implant. Control group included patients who had clinically healthy implant and tooth with healthy $periodontium(PD{\leq}3mm)$, test group was composed of patients who had clinically healthy implant and tooth with periodontal pocket(PD>3mm). The criteria of clinically health implant are no pain or discomfort, the restorative suprastructure provide satisfactory fit and function, and the tissue around the fixtures were firm and probing with standard periodontal probe with a rounded tip 0.5mm in diameter resulted in penetration of no more than 5mm when using a force of 0.5N at any location. 38 patients, partially edentulous subjects with endosseous root-form implants were selected. All subjects were medically healthy and had not taken systemic antibiotics and professional plaque control 3 months before sampling. Number of control group is 25(mean age $52{\pm}13$, 26 teeth, 34 implants) and test group is 13(mean age $60{\pm}13$, 13 teeth, 17 implants). All teeth and implants of each patient were examined probing depth(PD), bleeding on probing(BOP), and plaque index(PI), and samples of subgingival plaque were obtained at each site with sterile curet or fine paper points, then the plaque transferred to PBS. Obtained samples were examined for the presence of P. gingivalis, T. forsythensis, and T. denticola by the polymerase chain reaction(PCR). The relationship among clinical parameters and the colonizations by the 3 bacterial species from natural teeth and implants region were analyzed by student t-test. The results of this study were as follows: 1. PD was different in teeth between 2 groups(p<0.05), but the other parameters were not. 2. Statistically significant difference was not found in clinical parameters of implants between 2 groups. 3. All bacterial prevalences of teeth were higher in test group than in control group, and prevalence of T. forsythensis had statistically significant difference between 2 groups(p<0.05). 4. Prevalences of P. gingivalis and T. forsythensis are higher in test group than control group, and that of T. denticola is higher in control group than in test group. But there were no statistically significant differences between 2 groups. In conclusion, there is no statistically significant difference in prevalence of implant microbiology between 2 groups. But if the number of samples increased, it will be possible to find out statistical significance in prevalence of P. gingivalis. It seems that pocket of adjacent tooth influences prevalence of P. gingivalis. These results mean that improvement of the periodontal condition before implantation is very important.

600°C에서 제지류 소각시 발생하는 휘발성 유기화합물 농도분석 연구 (Analysis of Volatile Organic Compounds Produced from Incineration of Papers at 600°C)

  • 이병규;조정범
    • 한국환경과학회지
    • /
    • 제11권10호
    • /
    • pp.1109-1116
    • /
    • 2002
  • 본 연구는 제지류를 소각 처리할 때 발생하는 각종 휘발성 유기화합물에 대한 배출농도를 분석하였다. 실험대상으로는 일상생활에서 다양한 용도로 사용되는 제지류를 A4용지류 (A4 새종이, A4 잉크젯, A4레이져), 신문용지류 (콩기름 신문, 일반 신문), 포장용 Box지, 서류봉투류, 일회용 종이컵류, 화장지류로 분류하였고, 분류된 제지류의 수분함량과 소각시 발생하는 휘발성 유기화합물농도와 소각 재 함량을 분석하였다. 제지류 소각시 발생되는 휘발성 유기화합물을 Furan계, Aldehyde계, Aromatic계, Aliphatic Alkene계, Aliphatic Alkane계, Chlorine계, Ketone계로 분류할 때 가장 많이 발생하는 VOCs로는 Furan계로서 전체 배출농도의 57.4%였고, 그 다음으로 Aromatic계 (22.8%), Aliphatic Alkene계 (14.9%)의 순으로 놀은 평균농도를 나타냈다. 발생되는 휘발성 유기화합물 중 이중 결합을 포함하는 화합물 (Aromatic계, Aliphatic Alkene계, Ketone 및 Aldehyde계)틀의 상대적인 배출비중은 전체 배출농도에 대해 약 40.8%로써, 제지류의 소각에서 발생되는 휘발성 유기화합물의 40% 이상이 대기 중의 오존, 광화적 산화물 및 스모그의 전구체로써 작용할 수도 있을 것이다. 연구 사용된 전체 혼합 제지류 소각시 휘발성 유기화합물중 대표적인 발암성 물질인 Benzene, dichlorornethane, chloroform도 각각 60.5 ug/g, 0.8 ug/g 및 0.1 ug/g 정도 발생될 수 있음을 볼 수 있었다. 따라서, 소형 소각로에서의 제지류의 소각시 상당량의 발암성물질도 배출되므로, 소형 소각로에서도 적절한 VOCs의 제어장치가 꼭 필요한 것으로 판단된다. 본 연구에서 사용된 10가지의 제지류가 가지고 있는 평균 수분함량은 7.2% 정도로써 일반적인 도시폐기물의 제지류 수분함량 (4.5~10%)에 속하는 결과를 보였으며, 평균 9.0 %의 소각잔재 (BottomAsh) 함유량을 보였다. 이러한 결과는 제지류를 소형 소각로에서 소각시 유해 휘발성유기화합물의 발생에도 불구하고, 적절한 대기오염 방지시설을 설치한다면 소각처리가 폐기물 부피감소 측면으로는 상당한 경제적 타당성을 가지고 있음을 암시한다.

선형 트랜스듀서를 이용한 혈관 변형률 영상법 (Blood Vessel Strain Imaging Using Linear Array Transducer)

  • 안동기;정목근
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.880-890
    • /
    • 2010
  • 뇌졸중 등의 혈관 질병을 진단하기 위해서 혈관 내 초음파(Intravascular Ultrasound:IVUS)영상 기법이 사용되고 있다. 최근에는 혈관 내벽에 붙은 혈전을 탄성 영상법을 이용하여 진단하는 방법들이 연구되고 있다. 그러나 혈관 내 초음파는 혈관 내에 트랜스듀서를 삽입하여야 하므로 진단 방법에 위험성이 있다. 본 논문은 선형 트랜스듀서를 이용하여 혈관 외부에서 데이터를 획득하여 혈관 내벽에 붙은 혈전의 변형률 영상을 얻었다. 혈관 벽의 움직임을 정확하게 측정하기 위하여, 혈관 벽과 수직이 되도록 주사선의 방향을 조향하면서 초음파 데이터를 획득하였다. 초음파 데이터는 기저대역의 복소수 신호로 복조한 뒤 자기상관(autocorrelation)을 이용하여 혈관 벽의 움직임을 계산하여 변형률 영상을 얻었다. 제안한 방법을 플라스틱 기반의 혈관 모사 팬텀을 제작하여 검증하였다. 혈관 모사 팬텀은 혈관에 해당하는 직경 6mm의 실린더 공간에 물을 채우고 벽을 따라 2mm 두께의 부드러운 혈전을 혈관 벽의 내부에 배치하였다. RF 데이터는 상용 초음파 진단기에서 7.5MHz 선형 트랜스듀서를 사용하여 -40도부터 40도까지 1도 간격으로 조향시킨 81개의 스캔라인 데이터를 얻었다. 실험 결과 단단한 배경 팬텀에 인접한 혈전 영역이 더 무른 것으로 관찰되었다. 제안한 방법의 탄성 영상법이 비록 주사선이 혈관 벽에 수직으로 입사하는 영역으로 제한되지만 혈관 변형률 영상법의 유용함을 실험으로 입증하였다.

제세동 쇼크에 의한 심장 전류밀도 분포에 관한 시뮬레이션 연구 (A Simulation study on the Cardiac Current Density distribution during the Defibrillation Shock)

  • 이전;박광리;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.403-409
    • /
    • 2000
  • 본 연구는 3차원 유한요소 몸통 모델을 이용한 제세동 시뮬레이션 연구로서, 제세동 자극인가시 임상에서 사용되는 세가지 전극의 위치와 크기가 심장에서의 전류밀도 분포특성에서 미치는 영향과 시뮬레이션에 사용되는 조직의 비저항 값이 시뮬레이션 결과에 미치는 영향에 대하여 시뮬레이션 하였다. 몸통 모델은 타원형 실린더를 사용하여 흉곽을 모델링하였고, 나머지 부분은 Visible Human의 2차원 영상들을 통하여 3차원 모델링을 하였다. 그리고, ANSYS 5.4를 통하여 유한요소의 전류밀도 해를 구하였다. AP(anterior-posterior) 전극 위치의 경우, 몸통 표면에서 인가한 전류가 가장 효과적으로 심장으로 흘러들어 갔으며, LL(Lateral-lateral) 전극 AP(anterior-posterior) 전극 위치의 경우, 몸통 표면에서 인가한 전류가 가장 효과적으로 심장으로 흘러들어갔으며, LL(lateral-lateral) 전극위치는 가장 균일한 전류밀도 분포특성을 나타내었다. 그러나, 전극의 크기변화는 전류밀도 분포특성에 거의 영향을 주지 않았다. 조직의 비저항 값의 변화에 대한 전류밀도 분포 실험결과는 심근의 비저항 값의 변화가 최소·평균·최대 전류밀도 해에 가장 큰 영향을 주었다.

  • PDF

급성 중독에서 체외순환보조장치의 적용 (Extracorporeal Life Support in Acute Poisoning)

  • 이시진;한갑수;이의중;김도현;박경애;이지영;김수진;이성우
    • 대한임상독성학회지
    • /
    • 제16권2호
    • /
    • pp.86-92
    • /
    • 2018
  • Purpose: Cardiovascular or respiratory complications of acute intoxication are the most common causes of mortality. Advanced cardiac life support (ACLS) or specific antidotes help manage these cardiac or respiratory complications in acute intoxication. On the other hand, some cases do not respond to ACLS or antidotes and they require some special treatment, such as extracorporeal life support (ECLS). ECLS will provide the chance of recovery from acute intoxication. This study examined the optimal timing of ECLS in acute intoxication cases. Methods: This paper is a brief report of a case series about ECLS in acute poisoning. The cases of ECLS were reviewed and the effects of ECLS on the blood pressure and serum lactate level of the patients were analyzed. Results: A total of four cases were reviewed; three of them were antihypertensive agent-induced shock, and one was respiratory failure after the inhalation of acid. The time range of ECLS application was 4.8-23.5 hours after toxic exposure. The causes of ECLS implementation were one for recurrent cardiac arrest, two for shock that did not respond to ACLS, and one for respiratory failure that did not respond to mechanical ventilator support. Three patients showed an improvement in blood pressure and serum lactate level and were discharged alive. In case 1, ECLS was stared at 23.5 hours post toxic exposure; the patient died due to refractory shock and multiple organ failure. Conclusion: The specific management of ECLS should be considered when a patient with acute intoxication does not recovery from shock or respiratory failure despite ACLS, antidote therapies, or mechanical ventilator support. ECLS improved the hemodynamic and ventilator condition in complicated poisoned patients. The early application of ECLS may improve the tissue perfusion state and outcomes of these patients before the toxic damage becomes irreversible.

초등과학 5학년 1학기 '태양에서 행성까지 거리 비교'에 대한 초등예비교사들의 교재 재구성 내용 분석 (Analysis of Contents of Reorganization of Textbooks by Pre-Service Teachers' on 'Comparison of Distances from Solar System to Planets' in First Semester of Elementary Science 5th Grade)

  • 김해란;이용섭
    • 대한지구과학교육학회지
    • /
    • 제14권3호
    • /
    • pp.225-235
    • /
    • 2021
  • 이 연구의 목적은 천문 교육 방법의 개선 방향과 교육 자료 또는 소프트웨어 개발을 위한 시사점을 얻는데 있다. 교육과정 '태양계와 별' 지도와 연계하여 초등예비교사들에게 태양으로부터 행성까지의 상대적인 거리를 비교하는 재구성 과제를 제시한 후 이를 분석하였다. 연구 대상인 초등예비교사들은 B광역시 소재 초등 교사 양성 대학교 음악교육학과 2학년에 재학 중인 학생들로 남자 11명, 여자 19명이다. 도출된 시사점은 다음과 같다. 첫째, '두루마리 휴지를 이용한 거리 비교 활동'은 태양에서 행성까지의 거리를 단순 비교하는 데는 적합하지만 태양계의 광대함을 체험하게 하거나 학생 참여 중심의 수업을 이끌어내는 데는 한계가 있다. 둘째, 넓은 학습 공간의 확보와 함께 행성의 크기와 행성까지의 거리를 동시에 반영하고 또한 태양계의 광대함도 체험하며 실내에서 적용할 수 있는 초등학생용 소프트웨어 자료의 개발이 더 필요하다. 셋째, 교과서 자료는 초등예비교사의 수업 설계에 중요한 영향을 미친다.

동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가 (Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI)

  • 이길재;이훈재;이태수
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.103-113
    • /
    • 2022
  • 이 논문에서는 결합된 PET(fluorodeoxyglucose, 18F-FDG)와 MRI(magnetic nanoparticles, MNP) 조영제를 동시 PET-MRI 스캔에 사용하기 위한 가교제로 N-(p-maleimidophenyl) isocyanate를 사용하여 합성하는 방안을 제안하였다. 실험은 신경교종 줄기 세포 마우스 모델에서 결합 조영제(18F-FDG로 표지된 MNP)를 주입하기 전후에 PET-MRI 이미지를 획득하고 평가하였다. 획득한 각 영상에 대해 관심영역(ROI)을 설정한 후, 분할하여 병변의 면적을 계산하였을 때 PET 영상이 MRI 영상보다 더 크고 정확했다. 특히 동시 PET-MRI 영상은 주변 연조직과 함께 정확한 병변을 묘사하였다. 평균 및 표준편차 값은 조영제 주입 여부에 관계없이 PET 영상 또는 PET-MRI 동시 영상보다 MRI 단독 영상에서 더 높게 나타났다. 또한 동시 PET-MRI 영상값이 PET 영상보다 평균 및 표준편차 값이 높게 나타났다. 18F-FDG 라벨링된 MNP 조영제와 동시 PET-MRI 영상을 표적 영상으로 사용하고 18F- FDG 조영제만을 원본 이미지로 사용했을 때의 피크 신호 대 잡음비(PSNR) 값은 모든 실험에서 유의미 하게 나타났다. 결론적으로 동시 PET-MRI 영상에서 결합된 18F-FDG 표지 MNP 조영제가 유용함을 확인하였다. 다양한 핵종을 사용할 수 있는 SPECT-MRI 영상 연구를 통해 진단과 치료를 동시에 할 수 있는 제제를 개발하기 위해서는 향후 연구가 필요할 것이다.

미세플라스틱 배출원에 대한 초등예비교사들의 인식 조사 (The Investigation of Pre-Service Elementary Teachers' Awareness on the Sources of Microplastics)

  • 전경문
    • 과학교육연구지
    • /
    • 제46권3호
    • /
    • pp.223-236
    • /
    • 2022
  • 이 연구의 목적은 초등학교 예비교사들을 대상으로 미세플라스틱 배출원에 대한 인식을 조사하는 것이다. 연구 참여자는 학부 남학생 75명과 여학생 91명이었다. 미세플라스틱 배출원에 관한 선행연구들을 참조하여 15문항으로 구성된 설문지를 개발한 후, 전문가 검토 및 예비연구를 통해 수정하였다. 설문 결과, 응답자의 80% 이상이 이전에 뉴스, 인터넷, TV 등을 통해 미세플라스틱에 대해 들어본 경험이 있다고 하였다. 그러나 실험복, 물티슈, 황사용마스크, 종이컵 등이 미세플라스틱 원인물질로 제조된 것을 인지하지 못하는 경향이 있었다. 미세플라스틱 오염이 예상되는 상황을 묻는 설문에서도 '달리는 자동차의 타이어가 마모된다'와 '바닥에 붙어있는 껌이 작아진다'에 대한 선택 빈도가 상대적으로 낮았다. 이러한 결과는 상당수 예비교사들이 합성섬유나 합성고무가 미세플라스틱의 배출원임을 인지하지 못한다는 것을 보여준다. 미세플라스틱 문제에 대한 태도에서는 성별 차이가 나타났다. 즉, 여 예비교사들은 관련 문제에 더 관심을 보이고, 해결에 대한 참여 의지를 더 보이며, 미세플라스틱 관련 교육의 필요성을 더욱 절감하였다. 향후 과학교육을 위한 함의를 논의하였다.

봉합나사와 골터널을 이용한 골성 반카르트 병변의 고정 (Alternative Fixation Technique for Bony Bankart Lesion with Using Suture Anchor)

  • 김병국;이호재;김고탁;단진명
    • 대한정형외과학회지
    • /
    • 제54권6호
    • /
    • pp.574-578
    • /
    • 2019
  • 급성 견관절 탈구에 동반된 골성 반카르트 병변은 골편과 상완인대의 정확한 해부학적 정복과 안정된 고정이 치료에 필수적이며, 이의 실패는 견관절 재발성 불안정성과 외상 후 관절염을 유발할 수 있다. 반카르트 병변에 큰 뼈 조각 또는 분쇄된 골절 파편이 있는 경우, 관절경 수술 시 제한된 시야와 조작의 어려움으로 큰 골편을 골절 부위에 정확하고 견고하게 고정하는 것이 어렵다. 개방형 시술 시는 골편에 도달하고 고정하기 위하여 광범위한 연부 조직 유리 및 절제가 필요하여 이는 신경과 혈관 합병증, 견갑하건의 약화 및 견관절 강직 등, 외과적 접근법과 관련된 병적 상태를 유발할 수 있다. 저자들은 관절경적 수술이 용이하지 않은 크기의 관절와 골절이 동반한 견관절 전방 탈구 환자에서 골절면에 봉합나사 고정 후 골 터널을 만든 골편에 봉합사를 통과한 후 골편 및 상완인대를 함께 매듭 하여, 해부학적 위치로 안정된 정복을 얻는 수술방법을 보고하고자 한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF