• Title/Summary/Keyword: Tissue paper

Search Result 659, Processing Time 0.028 seconds

ITS : Intelligent Tissue Mineral Analysis Medical Information System (ITS : 지능적 Tissue Mineral Analysis 의료 정보 시스템)

  • Cho, Young-Im
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.257-263
    • /
    • 2005
  • There are some problems in TMA. There are no databases in Korea which can be independently and specially analyzed the TMA results. Even there are some medical databases, some of them are low level databases which are related to TMA, so they can not serve medical services to patients as well as doctors. Moreover, TMA results are based on the database of american health and mineral standards, it is possibly mislead oriental, especially korean, mineral standards. The purposes of this paper is to develope the first Intelligent TMA Information System(ITS) which makes clear the problems mentioned earlier ITS can analyze TMA data with multiple stage decision tree classifier. It is also constructed with multiple fuzzy rule base and hence analyze the complex data from Korean database by fuzzy inference methods.

Measurement of Dose Distribution in Small Fields of NEC LINAC 6 MVX Using Films and Tissue Equivalent Phantoms (필름 및 tissue equivalent 팬톰을 이용한 NEC LINAC 6 MVX 소조사면에 대한 선량분포 측정)

  • Suh, Tae-Suk;Park, Dong-Rak;Choe, Bo-Young;Yoon, Sei-Chul;Jang, Hong-Seok;Park, Il-Bong;Kim, Moon-Chan;Bahk, Yong-Whee;Shin, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.9-17
    • /
    • 1993
  • The purpose of this paper is to develop a simple system to measure dose distribution in small fields of NEC LINAC 6 MVX using film and solid water instead of ion chamber and water phantom. Specific quantities measured include percent depth dose (PDD), off-axis ratio (OAR). We produced square fields of 1 to 3cm in perimeter in 1cm steps measured at SAD of 80cm. The PDD and OAR measured by film was compared with measurement made with ion chamber. We calculated the TMR from the basic PDD data using the conversion formula. The trends of our measured beam data and philips LINAC are similar each other. The measurement for the small field using film and solid water was simple. Hand-made film phantom was especially useful to measure OARs for the stereotactic radiosurgery.

  • PDF

Clinical and Pathological Characteristics of Intraocular Cysticercosis

  • Li, Juan-Juan;Zhang, Li-Wei;Li, Hua;Hu, Zhu-Lin
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.2
    • /
    • pp.223-229
    • /
    • 2013
  • This study aimed to explore the clinical, radiological, and pathological characteristics of intraocular cysticercosis due to Taenia solium metacestode infection. Total 8 patients diagnosed with intraocular cysticercosis at the Red Cross Hospital of Yunnan Province, China were examined retrospectively. Patients with clear dioptic media had undergone fundus chromophotography. All patients underwent B ultrasonography of the ocular region (CT) successive scanning of the orbit and cerebral tissues. Parasites were extracted surgically and then examined pathologically. The fundus chromophotography showed a white and condensing scolex package in the vesicle. The B ultrasonic examination showed a vesicle-like echogenic mass in the vitreous chamber, in which the high-level echo spot was the cysticercus scolex. The pathological examinations showed that the vesicle wall exhibited hyaline degeneration, inflammatory cell infiltration, neuroglial fiber, and glial cell proliferation layers from the inside to the outside. The scolex is round and is composed of the outer tissue (the body wall) and the inner furrow tissue; these tissues migrated together. Primordially differentiated sucking discs were found in one case, but no hooklets were found. The inner scolex tissue was folded like a paper flower. The severity of intraocular disease is closely correlated with the pathophysiological processes of the cysticercus worm. Pathological examination of the intraocular lesions can help to evaluate the course of the disease as well as to provide a scientific basis for effective antiparasitic medication.

Combined Free Flaps in Reconstruction of Upper Extremity (결합 유리피판을 이용한 상지 복합결손의 재건)

  • Kim, Sug Won;Lee, June Bok;Lee, Sung Jun;Seul, Chul Hwan;Seo, Dong Wan
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • Advances in microvascular techniques and refinements in microsurgical tissue transfers have enabled surgeons to combine different tissue components and reconstruction into a single-stage operation in extensive or composite defect following injury. Some problems and consideration for extensive or composite defects are form, shape, function, and dimension of the defect sites. Therefore combination of two or more flaps is required to reconstruct extensive or composite defect. This paper presents our clinical experience of four cases of combined free flaps with or without sequential microanastomosis in reconstruction of upper extremity based on peroneal flowthrough, thoracodorsal, and dorsalis pedis vascular system. Satisfactory results were obtained without flap loss and complications. The free flaps were combined in th following fashion; two cases by bridge fashion, one by chimeric microanastomosis and one by simple chimeric fashion. The median follow-up time on all patients was 21.7 months. Donor site morbidity was minimal. Extensive soft tissue or composite defects can be effectively covered by various combined flaps. Even though the risk for complication exists, the options of combination with or without sequential microanastomosis can add a functional or sensory dimension to reconstruction of complex wounds.

  • PDF

A Robot End-effector for Biopsy Procedure Automation with Spring-Triggered Biopsy Gun Mechanism (스프링 격발형 생검총 구조를 가진 생검 시술 자동화 로봇 말단장치)

  • Won, Jong-Seok;Moon, Youngjin;Park, Sang Hoon;Choi, Jaesoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.590-596
    • /
    • 2016
  • Biopsy is a typical needle type intervention procedure performed under radiographic image equipment such as computed tomography (CT) and cone-beam CT. This minimal invasive procedure is a simple and effective way for identifying cancerous condition of a suspicious tissue but radiation exposure for the patients and interventional radiologists is a critical problem. In order to overcome such trouble and improve accuracy in targeting of the needle, there have been various attempts using robot technology. Those devices and systems, however, are not for full procedure automation in biopsy without consideration for tissue sampling task. A robotic end-effector of a master-slave tele-operated needle type intervention robot system has been proposed to perform entire biopsy procedure by the authors. However, motorized sampling adopted in the device has different cutting speed from that of biopsy guns used in the conventional way. This paper presents the design of a novel robotic mechanism and protocol for the automation of biopsy procedure using spring-triggered biopsy gun mechanism. An experimental prototype has been successfully fabricated and shown its feasibility of the automated biopsy sequence.

Comparative Tissue Ablation Study between 532 and 980 nm (가시광선과 근적외선 파장을 이용한 조직 제거 연구)

  • Kang, Hyun Wook;Oh, Junghwan
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.108-112
    • /
    • 2012
  • In this paper, two wavelengths mainly used for laser prostatectomy have been quantitatively compared: 532 and 980 nm. Two lasers at 40 W were employed to ablate bovine liver in vitro. Ablation performance was evaluated in light of number of sweeps, ablation volume, and coagulative necrosis. 532 nm yielded up to four times higher ablation efficiency than 980 nm. Regardless of wavelength, ablation rate per sweep decreased with the number of sweeps. 532 nm generated relatively deeper ablation craters along with thinner coagulation whereas 980 nm created superficial tissue ablation with up to 2 mm thick coagulative necrosis. Due to higher light absorption and effective thermal confinement, 532 nm induced more efficient tissue ablation with a smaller coagulative necrotic zone. The current study demonstrated that 532 nm could be a more ideal wavelength for laser prostatectomy, and the future in vivo investigations will confirm these findings.

Matrix solid phase dispersion(MSPD) extraction and HPLC determination of enrofloxacin and ciprofloxacin in pork muscle tissue (시료고체상분산(matrix solid phase dispersion)전처리법과 액체크로마토그라피를 이용한 돈육중 enrofloxacin 및 ciprofloxacin 분석)

  • Kang, Hwan-goo;Son, Seong-wan;Lee, Hye-sook;Kim, Jae-hak;Cho, Myung-haing
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.1
    • /
    • pp.195-202
    • /
    • 1997
  • A method for the isolation by matrix solid phase dispersion method and liquid chromatographic determination of enrofloxacin and ciprofloxacin in pork muscle tissue is presented. Blank or enrofloxacin and ciprofloxacin spiked samples(0.5g) containing 0.05g oxalic acid were blended with $C_{18}$(octadecylsilyl derivatized silica) packing material. After homogenization, $C_{18}$/muscle tissue matrix was transferred to glass column made from 10ml glass syringe and filter paper, and compressed to 4~4.5ml volume. A column was washed with 8ml of hexane and dried under vacuum. Interfering materials were removed by ethylacetate 8ml and dried, following which enrofloxacin and ciprofloxacin were eluted with 8ml of methanal under gravity. The eluate containing enrofloxacin and ciprofloxacin wase free from interfering compound when analysed by HPLC with UV detection at 278nm. Enrofloxacin and ciprofloxacin showed linear response with UV detector at the range of $0.05{\sim}1.0{\mu}g/ml$ and eluted within 5ml elution volume of methanol from the matrix. Fortified sample containing 0.05g oxalic acid represented more good recoveries than that of control sample. Average percentages of enrofloxacin and ciprofloxacin were $93.30{\pm}4.56%$ and $91.84{\pm}4.17%$, respectively, for the concentration range(0.05, 0.1, 0.25, 0.5 and $0.75{\mu}g/g$). The interassay variability of enrofloxacin was $6.02{\pm}5.33%$ with an intra-assay variability of 4.89% and $6.75{\pm}2.68%$ with 4.54% for ciprofloxacin. Detection limit of enrofloxacin and ciprofloxacin was $0.030{\mu}g/g$ in the spiked sample.

  • PDF

The study of the peri-inplant soft tissue around osseointegrated implants in partial edentulous patients (하악 부분 무치악 환자의 골유착성 임플랜트 주위 연조직에 관한 연구)

  • Jung, Keun-Sik;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.561-573
    • /
    • 1997
  • The keratinized mucosa around the implant is an important key in health of soft tissue and hard tissue. The purpose of this study is showed that the keratinized mucosa is associated with the keratinized mucosa index, plaque index, gingival index, probing depth. which is investigated to observing the peri-implant mucosa of mandibular partial edentulous patuent using periodontal parameter by previously published paper. It was estimated 6 site with regard to 80 fixture for 28 person, and the average age is 46.8. Each estimation is the order of less trauma, that is, plaque index, keratinized mucosa index, gingival index and probing depth. In this study, statstically analyzed treatment is used for Spss V 7.0 for Windows(Spss Inc, USA). The Kruskal Walis Test is used to compare the amount of the keratinized mucosa is into the $0{\sim}3$ index, with plaque index, gingival index and probing depth. Mann-whitney Test is used to interpreate the relation of plaque index and probing depth, which is showed significant difference. The Result are as follows 1. The kertinized mucosa index 3 amounts to 47.7%, which is much higher than the other indices and the index order is followed 3, 1, 2 and O. 2. The plaque index 1 amounts to 61.7%, which is much higher than the other indices and the index order is followed 1, 2, 3 and O. The plaque index 0 is significant to each of index(P<0.05). The plaque index is decrease as the keratinized mucosa index is increased. 3. The probing depth for 2mm, 1mm, 3mm is 48.9%, 23.5%, 16.8% respectively, which is most occupied. The probing depth 2mm and 3mm for the keratinized mucosa index is significant(P<0.05). The probing index is decreased as the keratinized mucosa index is increased. 4. The gingival index 0 amounts to 58.0%, which is much higher than the other indices and the index order is followed 0, 1, 2 and 3.

  • PDF

Non-Invasive Blood Glucose Sensor By Sub-Microwave Oscillator (준 마이크로파 발진기를 이용한 비 침습 혈당 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.9-16
    • /
    • 2017
  • In this paper, sub-microwave oscillator sensor is proposed to non-invasively monitor the glucose concentration level of the human biological tissue by oscillation frequency variation. Inductive slot in the ground plane of the microstrip line is combined with the biological tissue, to realize the resonator as a part of the oscillator sensor. The phantom box mimicking the human tissue is introduced for simulation of the resonator which resonance frequency correspondingly shifts up on three step glucose concentration levels(0, 400, 800 mg/dL). Oscillator sensor circuit is fabricated as a prototype. Pig tissues instead of human is used. Oscillation frequency shift of about 14 MHz per glucose level of 400 mg/dL has been successfully measured around 1,100 MHz. This proves that the proposed sensor is applicable to a blood glucose sensor.

An Extraction Method of Glomerulus Region from Renal Tissue Image (신장조직 영상에서 사구체 영역의 추출법)

  • Kim, Eung-Kyeu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.2
    • /
    • pp.70-76
    • /
    • 2012
  • In this paper, an automatic extraction method of glomerulus region from human renal tissue image is presented. The important information reflecting the state of kidneys richly included in the glomeruli, so it should be the first step to extract the glomerulus region from the renal tissue image for the further quantitative analysis of the renal condition. Especially, there is no clear difference between the glomerulus and other tissues, so the glomerulus region can not be easily extracted from its background by the existing segmentation methods. The outer edge of a glomerulus region is regarded as a common property for the regions of this kind ; a two- dimensional Gaussian distribution is used to convolve with an original image first and then the image is thresholded at this blurred image ; a closed curve corresponding to the outer edge can be obtained by usual pattern processing skills like thinning, branch-cutting, hole-filling etc., Finally, the glomerulus region can be obtained by extracting the area in the original image surrounded by the closed curve. The glomerulus regions are correctly extracted by 85 percentages and experimental results show the proposed method is effective.