• Title/Summary/Keyword: Tissue acquisition

Search Result 105, Processing Time 0.021 seconds

A Method for Observation of Benign, Premalignant and Malignant Changes in Clinical Skin Tissue Samples via FT -IR Microspectroscopy

  • Skrebova, Natalja;Aizawa, Katsuo;Ozaki, Yukihiro;Arase, Seiji
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.457-459
    • /
    • 2002
  • Sunlight causes various types of adverse skin changes on the sun-exposed areas of the skin, in which the most hazardous one is the induction of malignant skin tumours. FT -IR spectra were obtained from specimens excised from normal skin, BCCs, SCCs, MMs, nevi, lesions of solar keratosis and Bowen's disease. Tissue samples from freshly frozen specimens were cut into 2 sections in strictly sequential order to be stained with H & E for histopathological analysis, and then to be air-dried on CaF$_2$ slide glasses for further spectral data acquisition from defined area of interest. Intra- and inter-sample variations were estimated within grouped lesion categories according to each skin component. Mean spectra for each type of tissue pathology in the 800-1800 $cm^{-1}$ / region was interpreted using the classical group frequency approach that showed the most visible differences in spectra of benign, premalignant and malignant changes directly related to protein conformation and nucleic acid bases. The relative intensity of the nucleic acid peak was increased with progression to malignancy. In addition, PCA was able to evaluate and maximise the differences in the spectra by reducing the number of variables characterizing each patient and pathology category. This type of approach to non-destructively estimate the complexity of IR-spectra of inhomogeneous samples such as skin demonstrates the advantage of FT -IR microspectroscopy to be able to observe diseased states (benign, premalignant, malignant) and distinguish them from normal against a huge background of inter- and intra-subject variability.

  • PDF

Insert Transmission of Paulownia Witches'-Broom Mycoplmsma-Like Organism to Periwinkle Plant by Tobacco Leaf Bug, Cytropheltis tenuis Reuter (담배장님노린재에 의한 오동나무 빗자루병 MLO의 일일초로의 전반)

  • 나용준;박원철
    • Korean Journal Plant Pathology
    • /
    • v.10 no.3
    • /
    • pp.211-214
    • /
    • 1994
  • Paulowina witches'-broom mycoplasma-like organism (PWB-MLO) was transmitted experimentally to periwinkle (Catharanthus roseus L.) plant by tobacco leaf bug (Cyrtopeltis tenuis Reuter). Adults of the leaf bugs were allowed to feed on the witch's-broom infected paulownia (Paulownia tomentoas Steud.) trees for three weeks to insure the acquisition of PWB-MLO and then transferred to healthy seedlings of periwinkle and paulownia plants. In 25∼35 days after transfer of the viruliferous leaf bugs, six out of the ten periwinkle plants showed‘little-leaf’symptoms, while the paulowina seedlings remained symptomless. Presence of MLO in the infected periwinkle tissue was diagnosed by fluorescence microscopy and MLO particles were observed under electron microscope, confirming the transmission of PWB-MLO to periwinkle.

  • PDF

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

Under-Relaxed Image Restorative Technique for $Na^{23}$ MRI

  • Ro, D.W.;Ahn, C.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.64-67
    • /
    • 1992
  • To improve signal-to-noise ratio in sodium image, short echo time (2-3 ms) and long data acquisition (10-20 ms) protocols are used. Sodium in biological specimens demonstrates a bi-exponential decay of transverse magnetization and the fast decaying component of the sodium signal results in the reconstruction of images which are blurred significantly. The spatially-dependent nature of the blurs are due mainly to the presence of short local transverse relaxation values (0.7-3 ms) of sodium in tissue. We present an algorithm that corrects for object-dependent blurs due to fast-decaying T2 and improves the computational behavior of the algorithm by incorporating a relaxation parameter into the iterative process.

  • PDF

Transcriptional regulatory network during development in the olfactory epithelium

  • Im, SeungYeong;Moon, Cheil
    • BMB Reports
    • /
    • v.48 no.11
    • /
    • pp.599-608
    • /
    • 2015
  • Regeneration, a process of reconstitution of the entire tissue, occurs throughout life in the olfactory epithelium (OE). Regeneration of OE consists of several stages: proliferation of progenitors, cell fate determination between neuronal and non-neuronal lineages, their differentiation and maturation. How the differentiated cell types that comprise the OE are regenerated, is one of the central questions in olfactory developmental neurobiology. The past decade has witnessed considerable progress regarding the regulation of transcription factors (TFs) involved in the remarkable regenerative potential of OE. Here, we review current state of knowledge of the transcriptional regulatory networks that are powerful modulators of the acquisition and maintenance of developmental stages during regeneration in the OE. Advance in our understanding of regeneration will not only shed light on the basic principles of adult plasticity of cell identity, but may also lead to new approaches for using stem cells and reprogramming after injury or degenerative neurological diseases.

A Study on Utility of Magnetic Resonance Imaging for Female Pelvic Cavity using Enteral MRI Contrast Media (Enteral MRI contrast media를 이용한 여성골반 자기공명영상의 유용성)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.29-34
    • /
    • 1997
  • For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance Imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using Intravenous contrast. Expecially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used.

  • PDF

Development of 7-Year-Old Korean Child Model for Computational Dosimetry

  • Lee, Ae-Kyoung;Byun, Jin-Kyu;Park, Jin-Seo;Choi, Hyung-Do;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.237-239
    • /
    • 2009
  • A whole-body voxel model of a 7-year-old male volunteer was developed from 384 axial magnetic resonance images (MRIs). The MRIs were acquired with intervals of 3 mm for the entire body in a body coil. In order to reduce the MRI acquisition time for the child, the repetition and echo times under T1 weighted image were chosen to be 566 ms and 8 ms, respectively. The MRIs were classified according to 30 types of tissues with known electrical parameters. The developed voxel model was adjusted to the physical average of 7-year-old Korean boys. The body weight of the adjusted model, calculated with the mass tissue densities, is within a 6% difference from the 50th percentile weight.

  • PDF

Real-Time Fluorescence Imaging in Thoracic Surgery

  • Das, Priyanka;Santos, Sheena;Park, G. Kate;I, Hoseok;Choi, Hak Soo
    • Journal of Chest Surgery
    • /
    • v.52 no.4
    • /
    • pp.205-220
    • /
    • 2019
  • Near-infrared (NIR) fluorescence imaging provides a safe and cost-efficient method for immediate data acquisition and visualization of tissues, with technical advantages including minimal autofluorescence, reduced photon absorption, and low scattering in tissue. In this review, we introduce recent advances in NIR fluorescence imaging systems for thoracic surgery that improve the identification of vital tissues and facilitate the resection of tumorous tissues. When coupled with appropriate NIR fluorophores, NIR fluorescence imaging may transform current intraoperative thoracic surgery methods by enhancing the precision of surgical procedures and augmenting postoperative outcomes through improvements in diagnostic accuracy and reductions in the remission rate.

Multi-Parametric Quantitative MRI for Measuring Myelin Loss in Hyperglycemia-Induced Hemichorea

  • Youn, Sung Won;Kwon, Oh Dae;Hwang, Moon Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.148-156
    • /
    • 2019
  • Hyperglycemia-induced hemichorea (HGHC) is a rare but characteristic hyperkinetic movement disorder involving limbs on one side of the body. In a 75-year-old woman with a left-sided HGHC, conventional brain MR imaging showed very subtle T1-hyperintensity and unique gadolinium enhancement in the basal ganglia contralateral to movements. Multi-parametric MRI was acquired using pulse sequence with quantification of relaxation times and proton density by multi-echo acquisition. Myelin map was reconstructed based on new tissue classification modeling. In this case report of multi-parametric MRI, quantitative measurement of myelin change related to HGHC in brain structures and its possible explanations are presented. This is the first study to demonstrate myelin loss related to hyperglycemic insult in multi-parametric quantitative MR imaging.

Ex Vivo MR Diffusion Coefficient Measurement of Human Gastric Tissue (인체의 위 조직 시료에서 자기공명영상장치를 이용한 확산계수 측정에 대한 기초 연구)

  • Mun Chi-Woong;Choi, Ki-Sueng;Nana Roger;Hu, Xiaoping P.;Yang, Young-Il;Chang Hee-Kyung;Eun, Choong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.203-209
    • /
    • 2006
  • The aim of this study is to investigate the feasibility of ex vivo MR diffusion tensor imaging technique in order to observe the diffusion-contrast characteristics of human gastric tissues. On normal and pathologic gastric tissues, which have been fixed in a polycarbonate plastic tube filled with 10% formalin solution, laboratory made 3D diffusion tensor Turbo FLASH pulse sequence was used to obtain high resolution MR images with voxel size of $0.5{\times}0.5{\times}0.5mm^3\;using\;64{\times}32{\times}32mm^3$ field of view in conjunction with an acquisition matrix of $128{\times}64{\times}64$. Diffusion weighted- gradient pulses were employed with b values of 0 and $600s/mm^2$ in 6 orientations. The sequence was implemented on a clinical 3.0-T MRI scanner(Siemens, Erlangen, Germany) with a home-made quadrature-typed birdcage Tx/Rx rf coil for small specimen. Diffusion tensor values in each pixel were calculated using linear algebra and singular value decomposition(SVD) algorithm. Apparent diffusion coefficient(ADC) and fractional anisotropy(FA) map were also obtained from diffusion tensor data to compare pixel intensities between normal and abnormal gastric tissues. The processing software was developed by authors using Visual C++(Microsoft, WA, U.S.A.) and mathematical/statistical library of GNUwin32(Free Software Foundation). This study shows that 3D diffusion tensor Turbo FLASH sequence is useful to resolve fine micro-structures of gastric tissue and both ADC and FA values in normal gastric tissue are higher than those in abnormal tissue. Authors expect that this study also represents another possibility of gastric carcinoma detection by visualizing diffusion characteristics of proton spins in the gastric tissues.