• Title/Summary/Keyword: Tip60

검색결과 247건 처리시간 0.028초

THE TRANSCRIPTOME OF CANCER METASTASIS

  • Kim, Jung-Hwa;Choi, Hee-June;Kim, Bog-You;Lee, Ji-Min;Kim, Ik-Soo;Baek, Sung-Hee
    • 대한약리학회:학술대회논문집
    • /
    • 대한약리학회 2006년도 58th Annual Meeting of The Korean Society of Pharmacology
    • /
    • pp.48-48
    • /
    • 2006
  • PDF

DIC를 이용한 입자강화 복합재료의 파괴거동 평가 (Evaluation of Fracture Behavior on Particle Reinforced Composite Using Digital Image Correlation)

  • 홍상현;이정원;김재훈;이상연;박재범;정규동
    • 한국항공우주학회지
    • /
    • 제46권7호
    • /
    • pp.535-541
    • /
    • 2018
  • 본 연구에서는 입자강화 복합재료의 파괴거동을 평가하기 위해 쐐기분열시험을 수행하였다. 균열 저항성을 분석하기 위해 균열선단열림변위(CTOD)와 균열선단열림각도(CTOA)를 이용하였다. 사용된 입자강화 복합재료는 특성상 온도와 하중속도에 영향을 많이 받기 때문에 다양한 온도($-60^{\circ}C{\sim}50^{\circ}C$)와 하중속도(5~500mm/min)조건에서 시험을 수행하였다. 또한 균열선단에 대한 변형률장을 분석하기 위해 디지털 이미지 상관법(DIC)을 이용하였다. 시험결과 파괴에너지는 온도가 감소할수록 증가하였으며, 하중속도가 증가할수록 균열저항성이 증가하였다.

Experimental and numerical studies of the pre-existing cracks and pores interaction in concrete specimens under compression

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • 제23권5호
    • /
    • pp.479-493
    • /
    • 2019
  • In this paper, the interaction between notch and micro pore under uniaxial compression has been performed experimentally and numerically. Firstly calibration of PFC2D was performed using Brazilian tensile strength, uniaxial tensile strength and biaxial tensile strength. Secondly uniaxial compression test consisting internal notch and micro pore was performed experimentally and numerically. 9 models consisting notch and micro pore were built, experimentally and numerically. Dimension of these models are 10 cm*1 cm*5 cm. the length of joint is 2 cm. the angularities of joint are $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$. For each joint angularity, micro pore was situated 2 cm above the lower tip of the joint, 2 cm above the middle of the joint and 2 cm above the upper of the joint, separately. Dimension of numerical models are 5.4 cm*10.8 cm. The size of the cracks was 2 cm and its orientation was $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$. Diameter of pore was 1cm which situated at the upper of the notch i.e., 2 cm above the upper notch tip, 2 cm above the middle of the notch and 2 cm above the lower of the notch tip. The results show that failure pattern was affected by notch orientation and pore position while uniaxial compressive strength is affected by failure pattern.

EFFECTS OF THE ER,CR:YSGG LASER ON BONE BED PREPARATION WITH VARIOUS LASER TIPS

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Hong, Seong-Doo;Lee, Shin-Jae;Lee, Joo-Hee
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.255-260
    • /
    • 2008
  • STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 ${\mu}s$ pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mm${\Phi}$), Group 2: paralleled - shaped zirconia tip (0.6 mm${\Phi}$), Group 3: tapered sapphire tip (0.4 mm${\Phi}$). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

軟鋼 熔接熱影響部의 塑性變形擧動에 關한 硏究 II (A Study the Behavior of Plastic Deformation in Weld HAZ of Mild Steel)

  • 박창언;정세희
    • Journal of Welding and Joining
    • /
    • 제10권1호
    • /
    • pp.43-51
    • /
    • 1992
  • The plastic zone formed around a notch tip is important in analyzing the fracture toughness of structures and particularly weld cracks existed in the weld HAZ (heat affected zone) which produces local plastic deformation at the crack tip. Therefore, in order to analyze the fracture toughness in weld HAZ, it is necessary to investigate the new fracture toughness parameter $K_{c}$ $^{*}$ and critical plastic strain energy $W_{p}$ $^{c}$ according to the shape and size of the plastic zone. 1) If the temperature corresponding to $K_{c}$ $^{*}$=130kg-m $m^{-3}$ 2/ is determined, transition temperature $T_{tr}$ the magnitude of plastic zone size, and heat input change depending on the fracture toughness. The blunted amounts of the parent and weld HAZ show mild linear variation until .delta.=0.4mm and then increase very steeply there after. 2) The relation between the plastic strain energy( $W^{p}$ ) and transition temperature( $T_{*}$tr) in parent metal is more sensitive than that of weld HAZ. However, the plastic strain energy depends on the transition temperature, and thus the yield stress, .sigma.$_{ys}$ becomes an important parameter for plastic strain energy. 3) The critical plastic strain energy( $W_{p}$ $^{c}$ ) absorbed by the plastic zone at the notch tip indicated in case of parent metal: 60J/mm, in case of heat input(20KJ/cm): 75J/mm, in case of heat input(30KJ/cm); 50J/mmJ/mm.

  • PDF

SPRAY CHARACTERISTICS OF DME IN CONDITIONS OF COMMON RAIL INJECTION SYSTEM(II)

  • Hwang, J.S.;Ha, J.S.;No, S.Y.
    • International Journal of Automotive Technology
    • /
    • 제4권3호
    • /
    • pp.119-124
    • /
    • 2003
  • Dimethyl Ether (DME) is an excellent alternative fuel that provides lower particulate matter (PM) than diesel fuel under the same engine operating conditions. Spray characteristical of DME in common rail injection system were investigated within a constant volume chamber by using the particle motion analysis system. The injector used in this study has a single hole with the different orifice diameter of 0.2, 0.3 and 0.4 mm. The injection pressure was fixed at 35MPa and the ambient pressure was varied from 0.6 to 1.5 MPa. Spray characteristics such as spray angle, spray tip penetration and SMD (Sauter mean diameter) were measured. Spray angle was measured at 30d$_{0}$, downstream of the nozzle tip. The measured spray angie increased with increase in the ambient pressure. Increase of the ambient pressure results in a decrease of spray penetration. The experimental result, of spray penetration were compared with the predicted one by theoretical and empirical models. Increase in the ambient pressure and nozzle diameter results in an increase of SMD at a distance 30, 45 and 60d$_{0}$, downstream of the nozzle, respectively.ely.

새도우마스크 제조 공정중 발생되는 폐액으로부터 분무열분해 공정에 의한 복합산화물 나노 분말 제조 (Fabrication of Nano-Sized Complex Oxide Powder from Waste Solution Produced during Shadow Mask Processing by Spray Pyrolysis Process)

  • 유재근
    • 자원리싸이클링
    • /
    • 제12권6호
    • /
    • pp.38-46
    • /
    • 2003
  • 본 연구에서는 새도우마스크 제조공정 중 발생되는 Fe-Ni계 복합 폐산을 원료로 하여 공기압력 1kg/$ extrm{cm}^2$의 조건에서 분무열분해 공정에 의해 평균입도 100nm 이하의 니켈 페라이트($NiFe _2$$O_4$)및 $_Fe2$O$_3$+NiO 나노 분말을 제조하였으며, 반응온도, 폐산용액의 농도 및 nozzle tip 크기의 반응인자들의 변화에 따른 생성된 분말의 특성 변화를 파악하였다. 반응온도가 $800^{\circ}C$로부터 $1100 ^{\circ}C$로 변화함에 따라 분말의 평균입도는 40nm로부터 100nm 정도까지 증가하고 있었으며 조직은 더욱 치밀화되는 반면 입도분포는 점점 불균일하게 됨을 알 수 있었다. 반응온도의 증가에 따라 니켈 페라이트 상의 생성 비율이 현저히 증가하고 있었으며 분말의 비표면적은 현저히 감소하고 있었다. 원료용액 내의 Fe 성분의 농도가 20g/l로 부터 200g/l로 증가됨에 따라 분말의 평균 입도는 30m로 부터 60nm 정도까지 점점 증가하는 반면 입도분포는 더욱 불균일하게 나타나고 있었다. 또한 용액의 농도 증가에 따라 니켈 페라이트 상의 생성 비율이 증가하고 있었으며, 분말의 비표면적은 현저히 감소하였다. Nozzle tip 크기 증가에 따라 분말의 입도분포는 점점 불균일하게 나타나는 반면 평균 입도는 현저한 변화를 나타내지 않았다. Tip 크기가 2mm까지는 tip 크기 증가에 따라 니켈 페라이트 상의 생성 비율에 현저한 변화는 나타나지 않는 반면 분말의 비표면적은 약간 감소하였다. Tip 크기가 3mm 및 5mm로 증가하는 경우에는 니켈 페라이트 상의 생성 비율이 점점 감소하고 있었으며, 분말의 비표면적은 약간씩 증가하고 있음을 알 수 있었다.

원자로 제어봉 End-Tip 원주방향균열 와전류검사 (RCCA End-Tip Examination by ECT)

  • 이희종;남민우;정계조
    • 비파괴검사학회지
    • /
    • 제18권6호
    • /
    • pp.455-463
    • /
    • 1998
  • 경수로형 원자로 제어봉집합체(rod cluster control assembly)의 제어봉선단 봉단마개 부위에 발생할 수 있는 원주방향균열을 검출하기 위한 다중표면 와전류탐촉자를 설계하였으며, 이를 MIZ-30 주파수발생장치에 연 결하여 원주방향균열을 검출하고 원주방향길이를 측정 할 수 있는 와전류검사기술을 개발하였다. $8{\times}1$ 다중표면 와전류탐촉자는 원주방향으로 발생할 수 있는 균열 검사에 적합하도록 탐촉자 내부 원주방향으로 8개 표면코일을 일정간격으로 배치하고 코일 후방에 스프링을 설치하여 주사시 코일 머리부분이 표면에 밀착되므로서 코일과 피복관표면 사이의 lift-off 발생이 최소가 되도록 설계하였다. LCR-meter 및 HP-VEE 프로그램을 사용하여 코일의 전기적 특성을 평가하였으며, 탐촉자의 균열검출 특성은 Miz-30과 Eddynet 프로그램을 사용하여 평가하였다. 교정 standard와 시험편은 $14{\times}14$형 제어봉피복관(SS-304, 외경 : 10.95mm, 두께 : 0.48mm)을 사용하여 축방향과 원주방향으로 깊이와 길이를 달리하여 여러가지 균열성 EDM노치 (폭 0.2mm, 관두께의 15, 25, 40, 50, 60%깊이)를 가공하였으며, 이를 이용하여 탐촉자의 균열검출 및 크기측정 특성을 평가한 결과 제어봉 튜브표면에 발생한 원주균열의 검출 가능 최소길이는 3.5mm이고, 깊이는 ${\pm}5.31%$ RMS 오차 이내로 측정 할 수 있었다. 또한, 제어봉선단 봉단마개 부위에 발생할 수 있는 마모, 스크레치, 축 및 원주방향균열 신호는 신호의 위상과 신호형상을 분석하므로서 구분이 가능하였다.

  • PDF

MEMS 기술을 이용한 프로브 카드의 탐침 제작 (Fabrication of Tip of Probe Card Using MEMS Technology)

  • 이근우;김창교
    • 제어로봇시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.361-364
    • /
    • 2008
  • Tips of probe card were fabricated using MEMS technology. P-type silicon wafer with $SiO_2$ layer was used as a substrate for fabricating the probe card. Ni-Cr and Au used as seed layer for electroplating Ni were deposited on the silicon wafer. Line patterns for probing devices were formed on silicon wafer by electroplating Ni through mold which formed by MEMS technology. Bridge structure was formed by wet-etching the silicon substrate. AZ-1512 photoresist was used for protection layer of back side and DNB-H100PL-40 photoresist was used for patterning of the front side. The mold with the thickness of $60{\mu}m$ was also formed using THB-120N photoresist and probe tip with thickness of $50{\mu}m$ was fabricated by electroplating process.

Neriene bovista sp. nov., a new sheet-web spider (Araneae: Linyphiidae) from Korea

  • Lee, Sue Yeon;Yoo, Jung Sun;Kim, Seung Tae
    • Journal of Species Research
    • /
    • 제11권2호
    • /
    • pp.94-97
    • /
    • 2022
  • Linyphiidae Blackwall, 1859 is one of the most diverse and largest families within the order Araneae Clerck, 1757. Of the currently 60 valid species of the genus Neriene Blackwall, 1833 worldwide, 10 species are distributed in Korea. The males of the new sheet-web spider Neriene bovista sp. nov. were recently collected with a sweep net between the shrubs of mixed forests from the hilly valley with well conserved nature in Uljin-gun, Gyeongsangbuk-do (the middle east coast region) during a seasonal survey of the spider fauna in hilly terrains in 2017-2018. The present study describes a new sheet-web spider, Neriene bovista sp. nov. with a diagnosis, detailed description, morphological illustrations, and a distribution map from Korea. The new species has a characteristic mushroom-like tip of the terminal apophysis, the truncated tip of anterior projection, and the bifurcated lateral projection of the lamella compared to the congeners of the genus Neriene Blackwall, 1833.