• Title/Summary/Keyword: Tip-off

Search Result 140, Processing Time 0.033 seconds

Prediction of flow field in an axial compressor with a non-uniform tip clearance at the design and off-design conditions (설계점 및 탈설계점에서 비균일 익단 간극을 가지는 축류 압축기의 유동장 예측)

  • Kang, Young-Seok;Park, Tae-Choon;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.46-53
    • /
    • 2008
  • Flow structures in an axial compressor with a non-uniform tip clearance were predicted by solving a simple prediction method. For more reliable prediction at the off-design condition, off-design flow characteristics such as loss and flow blockage were incorporated in the model. The predicted results showed that flow field near the design condition is largely dependent on the local tip clearance effect. However overall flow field characteristics are totally reversed at off-design condition, especially at the high flow coefficient. The tip clearance effect decreases, while the local loss and flow blockage make a complicated effect on the compressor flow field. The resultant fluid induced Alford's force has a negative value near the design condition and it reverses its sign as the flow coefficient increases and shows a very steep increase as the flow coefficient increases.

Decrease of Gate Leakage Current by Employing Al Sacrificial Layer Deposited on a Tilted and Rotated Substrate in the DLC-coated Si-tip FEA Fabrication (DLC-coated Si-tip FEA 제조에 있어서 기판 상에 경사-회전 증착된 Al 희생층을 이용한 Gate누설 전류의 감소)

  • 주병권;김영조
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.27-29
    • /
    • 2000
  • For the DLC-coaled Si-tip FEA, the modified lift off-process, by which DLC coated on both gate electrode surface and gate insulator in the gate aperture could be removed, was proposed. In the process, the Al sacrificial layer was deposited on a tilted and rotated substrate by an e-beam evaporation, and DLC film was coated on the substrate by PA-CVD method. Afterward the DLC was perfectly removed except the DLC films coated on emitter tips by etch-out of Al sacrificial layer. Current-voltage curves and current fluctuation of the DLC-coated Si-tip FEA showed that the proposed lift-off process played an important role in decreasing gate leakage current and stabilizing omission current.

  • PDF

A Multi-Attribute Negotiation System with Tip-off information for Reciprocity (상호 이익의 보장과 Tip-off 정보를 이용한 다중 속성 협상 시스템)

  • 유한청;양성봉
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10a
    • /
    • pp.37-39
    • /
    • 2003
  • 구매자와 판매자를 대신하는 협상 에이전트는 전자상거래에서의 중요성에도 불구하고 아직까지 현실 생활에 적용될 수 있는 수준에 이르지 못하고 있다. 본 논문에서는 Tip-off 정보를 이용해 상호 이익을 보장하며 협상 결과 및 협상 수행 시간을 동시에 고려한 다중 속성 협상 시스템을 제안한다. 제안 시스템의 성능을 평가하기 위한 기준 시스템으로써 양자간 모든 정보를 가지고 최적 협의를 도출할 수 있는 중개 에이전트 시스템을 구현하고 이를 본 논문에서 제안한 협상시스템과 비교하였다. 본 논문에서 제안한 시스템은 상대방의 모든 정보를 완벽하게 알지 못하는 상황에서 최적의 협의에 가까운 결과를 도출하였고. 협상 수행시간에 있어서는 매우 빠른 성능을 보여주었다.

  • PDF

Distribution of the Reynolds Stress Tensor inside Tip Leakage Vortex (익단 누설 와류내의 레이놀즈 응력 분포)

  • Lee, Gong-Hee;Park, Jong-Il;Baek, Je-Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.496-501
    • /
    • 2003
  • Reynolds averaged Wavier-Stokes simulations based on the Reynolds stress model was performed to investigated the effect of inlet flow angle on the distributions of the Reynolds stress tensor inside tip leakage vortex of a linear compressor cascade. Two different inlet flow angles ${\beta}=29.3^{\circ}$(design condition) and $36.5^{\circ}$(off-design condition) were considered. Stress tensor analysis, which transforms the Reynolds stress into the principal direction, was applied to show an anisotropy of the normal stresses. Whereas the anisotropy was highest in the region where the tip leakage vortex collides the suction side of the blade and tip leakage flow enters between blade tip of the pressure side and the endwall, it had the lowest value at the center of tip leakage vortex. It was also found that the magnitude of maximum shear stress at design condition was greater than that of off-design condition.

  • PDF

Fabrication of ultra-sharp tungsten tip using electro-chemical etching system (전기화학적 에칭방법을 이용한 초미세 바늘 전극 제작)

  • 오현주;장동영;강승언
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.449-452
    • /
    • 2004
  • To obtain the ultra-sharp tungsten tip, an analog to digital converter circuit aided by a personal computer has been setup. At the moment the lower part of the needle drops off during the etching process, a maximum current change across the reference resistor is detected by the PC interface card and the applied voltage is then cut off within a few milliseconds. Out experiment has been able to fabricate an ultra-sharp tungsten tip ~200 $\AA$ radius with a higher reproduction rate and reliability than the conventional method.

  • PDF

Measurement of plasma potential by a biased cut off probe

  • Kim, Dae-Ung;Kim, Jeong-Hyeong;Seong, Dae-Jin;Yu, Sin-Jae;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.465-465
    • /
    • 2010
  • Cut off probe, the efficient method, can measure the plasma parameters like the plasma electron density and the electron temperature. Plasma potential is also one of the important parameters in plasma processing but cannot be measured by cut off probe yet. Thus we developed method to measure plasma potential by focusing on relation between bias on a tip and sheath around tip. The system consist of a ICP(Inductive Coupled Plasma) source, a Network analyzer and a bias tee that can be bridge apply DC voltage on the cut off probe tip. Plasma potential is identified by using this system. The results corresponded well with the measured results by single langmuir probe(SLP).

  • PDF

Off-Design Performance Prediction of an Axial Flow Compressor Stage Using Simple Loss Correlations (간단한 손실모델을 이용한 단단축류압축기 탈설계점 성능예측)

  • 김병남;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3357-3368
    • /
    • 1994
  • Total pressure losses required to calculate the total-to-total efficiency are estimated by integrating empirical loss coefficients of four loss mechanisms along the mean-line of blades as follows; blade profile loss, secondary flow loss, end wall loss and tip clearance loss. The off-design points are obtained on the basis of Howell's off-design performance of a compressor cascade. Also, inlet-outlet air angles and camber angle are obtained from semi-empirical relations of transonic airfoils' minimum loss incidence and deviation angles. And nominal point is replaced by the design point. It is concluded that relatively simple loss models and Howell's off-design data permit us to calculate the off-design performance with satisfactory accuracy. And this method can be easily extended for off-design performance prediction of multi-stage compressors.

Distribution of the Reynolds Stress Tensor Inside Tip Leakage Vortex of a Linear Compressor Cascade (I) - Effect of Inlet Flow Angle - (선형 압축기 익렬에서 발생하는 익단 누설 와류내의 레이놀즈 응력 분포 (I) -입구 유동각 변화의 영향-)

  • Lee, Gong-Hee;Park, Jong-Il;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.902-909
    • /
    • 2004
  • A steady-state Reynolds averaged Navier-Stokes simulation was conducted to investigate the distribution of the Reynolds stress tensor inside tip leakage vortex of a linear compressor cascade. Two different inlet flow angles ${\beta}=29.3^{\circ}$(design condition) and $36.5^{\circ}$(off-design condition) at a constant tip clearance size of $1\%$ blade span were considered. Classical methods of solid mechanics, applied to view the Reynolds stress tensor in the principal direction system, clearly showed that the high anisotropic feature of turbulent flow field was dominant at the outer part of tip leakage vortex near the suction side of the blade and endwall flow separation region, whereas a nearly isotropic turbulence was found at the center of tip leakage vortex. There was no significant difference in the anisotropy of the Reynolds normal stresses inside tip leakage vortex between the design and off-design condition.

Enhancement of Burner Performance of Household Gas Fired Absorption Chiller/Heaters (가정용 가스 냉난방기용 연소기의 성능개선 연구)

  • Yoon, Young-Seok;You, Hyun-Seok;Kim, Tae-Han;Lee, Joong-Seong;Han, Jeong-Ok
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.111-115
    • /
    • 1999
  • In order to enhance the burner performance of household gas fired absorption chiller/heaters, the operating condition(excess air $\approx$ 10%) of the burner currently being used was required to be optimized. In this regard, we examined where the $CO_{\min}$. emission limit was located between blow off and yellow tip limit and how much amount of excess air was exhausted by means of observing blow off and yellow tip limit. It was found that the $CO_{\min}$ limit(excess air ${\approx}$ 4%) was determined near the yellow tip limit. The effect of exhaust pressure on the $CO_{\min}$. limit was that, if exhaust pressure was higher than that in steady condition, higher air blower fan rpm is demanded to maintain the $CO_{\min}$ limit. Therefore, it was necessary to optimize the operating condition of burner in terms of a thermal efficiency and safety.

  • PDF

Characteristics an Circuit Model of a Field Emission Triode

  • Nam, Jung-Hyun;Ihm, Jeong-Don;Kim, Jong-Duk;Kim, Yeo-Hwan;Park, Kyu-Man
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.129-133
    • /
    • 1997
  • A circuit model for a field emission triode has been proposed. The model parameters have been extracted from he fabricated silicon tip array and verified by comparing with the results simulated by circuit simulator(SPICE). The cut-off frequency can be calculated from the parametric capacitance and the transconductance values extracted from measurements. For the field emission triode, the capacitance of 3.45fF/tip and the transconductance of 0.94nS/tip have been measured under the emission current of 4.1nA/tip. From these values, the cut-off frequency is predicted to be 43 kHz but th measured one came out to be 6 kHz. because o the parasitic capacitance components.

  • PDF