• 제목/요약/키워드: Tip leakage flow

검색결과 129건 처리시간 0.023초

이차흐름에 의한 스팬방향의 믹싱효과를 고려한 준3차원 계산법을 이용한 사류송풍기 내부흐름의 해석 (An Analysis of Internal Flow of Diagonal Flow Blower with Quasi-Three-Dimensional Calculation Method Considering the Spanwise Mixing due to Secondary Flow)

  • 박상록;김영중;김태환
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.21-31
    • /
    • 1999
  • This paper presents a quasi-three-dimensional calculation method considered a spanwise mixing effect in a diagonal flow impeller. The effect of this spanwise mixing caused by spanwise distribution of blade loading is evaluated by a secondary flow theory. In order to verify the validity of this method, it is applied to the analysis of a diagonal flow fan designed under a vortex type of constant circumferential velocity and that of a free vortex. The comparison of the calculated result with experimental data shows a good agreement except the regions near the casing where the flow field is affected by the tip leakage flow.

  • PDF

냉각탑용 축류팬의 팁 간격이 팬 성능 및 틈새 유동에 미치는 영향에 관한 수치해석적 연구 (Numerical Investigation of Effects of Tip Clearance Height on Fan Performance and Tip Clearance Flow in an Axial Fan of the Cooling Tower)

  • 오건제
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.44-50
    • /
    • 2012
  • 팁 간격의 크기가 냉각탑용 축류팬의 성능과 누설 유동에 미치는 영향을 조사하기 위해서 서로 다른 2가지 팁 간격을 가진 경우에 대해서 점성유동을 해석하였다. 케이싱 내에서 작동하는 축류팬 주위의 유동을 연속방정식, Navier-Stokes 방정식 등을 지배방정식으로 사용하여 수치해석 하였다. 난류유동에 나타나는 레이놀즈 응력은 ${\kappa}-{\epsilon}$ 난류모델을 사용하여 계산하였다. 전체적으로 H형 격자계를 사용하였으며, 팁 주위의 유동을 해석하기 위해서 팁 영역 주위에 부분적으로 조밀한 격자를 두었다. 팁 간격이 증가하면 누설 유동의 증가로 인한 유동 손실의 증가로 전압상승과 수력효율이 감소하였다. 팬 직경에 대한 팁 간격이 0.4%에서 1.0%로 증가하면 전압상승 값이 약 10% 정도 감소하였으며, 수력효율은 약 3% 정도 감소하였다. 팁 간격이 팁 근처 날개 주위의 압력에 미치는 영향을 보면, 팁 간격이 증가하여 누설 유동이 증가하면 흡입면과 압력면의 압력차가 전연 부근에서 감소함을 알 수 있었다. 누설 와류의 중심은 코드를 따라서 흡입면으로 부터 떨어져 나가면서 형성됨을 알 수 있었다. 누설 와류의 위치를 보면 팁 간격이 증가하면 와류 중심의 위치가 흡입면 쪽으로 이동하고, 흡입면에서 떨어진 거리도 날개 후반부에서 증가 폭이 커지는 포물선 형태로 증가함을 알 수 있었다.

천음속 원심압축기 내부 유동의 수치해석 (Numerical Study of the Flow in a Transonic Centrifugal Compressor)

  • 성선모;강신형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.228-231
    • /
    • 2008
  • Flow fields of a transonic centrifugal compressor are calculated using the commercial CFD code, CFX-TASCflow. Due to the transonic inlet condition, interactions between the shock wave and boundary layers and between the shock wave and tip leakage vortices generate complex flow structures and extra losses. The calculated results show that strong secondary flows due to high curvature and high rotational speed of the impeller. And streamlines near suction surface show that strong radially upward flow develops after the shock between the leading edge locations of main blade and splitter.

  • PDF

연구용 저속 축류압축기의 내부 유동 특성에 관한 실험적 연구 (Experimental Study on the Flow Characteristics in a Low Speed Research Compressor)

  • 박태춘;한정엽;강신형
    • 한국유체기계학회 논문집
    • /
    • 제11권6호
    • /
    • pp.54-63
    • /
    • 2008
  • A study on the flow characteristics in a 4-stage axial compressor and the behavior of rotating stall was experimentally performed at the third-stage rotor and stator rows in order to investigate its performance and instability of the compression system. The pressure losses generated due to the leakage flow at a tip clearance and a shroud seal clearance and the wake flow near the trailing edge of a blade were taken into consideration to estimate the causes of performance drop of the low speed research compressor(LSRC) in Seoul national university. In addition, the measurement of rotating stall was conducted with hot-wire probes and the existence and propagation of stall cell could be confirmed through fast Fourier transform and cross-correlation analysis.

Performance Prediction and Flow Field Calculation for Airfoil Fan with Impeller Inlet Clearance

  • Kang, Shin-Hyoung;Cao, Renjing;Zhang, Yangjun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권2호
    • /
    • pp.226-235
    • /
    • 2000
  • The performance prediction of an airfoil fan using a commerical code, STAR/CD, is verified by comparing the calculated results with measured performance data and velocity fields of an airfoil fan. The effects of inlet tip clearance on performance are investigated. The calculations overestimate the pressure rise performance by about 10-25 percent. However, the performance reduction due to tip clearance is well predicted by numerical simulations. Main source of performance decrease is not only the slip factor but also impeller efficiency. The reduction in performance is 12-16 percent for 1 percent gap of the diameter. The calculated reductions in impeller efficiency and slip factor are also linearly proportional to the gap size. The span-wise distributions of phase averaged velocity and pressure at the impeller exit are strongly influenced by the radial gap size. The radial component of velocity and the flow angle increase over the passsage as the gap increases. The slip factor decreases and the loss increases with the gap size. The high velocity of leakage jet affects the impeller inlet and passage flows. With a larger clearance, the main stream moves to the impeller hub side and high loss region extends from the shroud to the hub.

  • PDF

PTV 계측법에 의한 극저비속도 원심펌프의 내부유동특성에 관한 연구 (A Study on the Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump by PTV)

  • 최영도;마쯔이준;쿠로카와준이치;이영호
    • 한국유체기계학회 논문집
    • /
    • 제9권1호
    • /
    • pp.9-18
    • /
    • 2006
  • In the range of very low specific speed ($n_s<0.25$, non-dimensional), the performance of a centrifugal pump is much different from that of a centrifugal pump of normal ns and the efficiency of the pump drops rapidly with the decrease of $n_s$. In order to examine the reason of unstable performance characteristics of the very low $n_s$- centrifugal pump, the internal flow of the pump with a semi-open impeller is measured by a PTV(Particle Tracking Velocimetry) system. The purpose of this study is to make clear the internal flow characteristics and to obtain basic knowledge of the pump performance. The results show that the leakage flow through tip clearance give a strong effect on the flow pattern of impeller passage. A large vortex in the impeller passage and a strong reverse flow at impeller outlet are formed in the range of small flow rates, and the vortex and the reverse flow together reduce the absolute tangential velocity at the impeller outlet and cause the performance instability.

점성 손실모델 도입에 의한 축류 압축기 준 3차원 압축성 유동해석 (A Study on the Quasi-3-Dimensional Compressible Flow Calculation by Introduction of Viscous Loss Model in Axial-Flow Compressor)

  • 조강래;이진호;김주환
    • 대한기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.1044-1051
    • /
    • 1989
  • 본 연구에서는 Wu가 제시한 수학적 모델에 기초를 둔 비점성 준3차원 유동해 석에 실제 유체의 점성효과 및 2차유동 등에 의해 발생하는 손실들을 손실모델로 반영하여 그 타당성 유무를 검토하는 데 목적을 두었다.

극저비속도 원심펌프의 성능과 내부유동특성에 관한 연구 (A Study on the Performance and Internal Flow Characteristics of a Very Low Specific Speed Centrifugal Pump)

  • 쿠로카와준이치;이영호;최영도
    • 대한기계학회논문집B
    • /
    • 제29권7호
    • /
    • pp.784-794
    • /
    • 2005
  • In the very low specific speed range ($n_s=0.24$ < 0.25, non-dimensional), the efficiency of centrifugal pump designed by a conventional method is very low in common. Therefore, positive-displacement pumps have long been used widely. Recently, since the centrifugal pumps are becoming higher in rotational speed and smaller in size, there expects to develop a new centrifugal pump with a high performance to replace the positive-displacement pumps. The purpose of this study is to investigate the internal flow characteristics of a very low specific speed centrifugal pump and to examine the effect of internal flow pattern on pump performance. The results show that the theoretical head definition of semi-open impeller should be revised by the consideration of high slip factor in the semi-open impeller, and the leakage flow through the tip clearance results in a large effect on the impeller internal flow. Strong reverse flow at the outlet of semi-open impeller reduces the absolute tangential velocity considerably, and the decreased absolute tangential velocity increasese the slip factor with the reduction of theoretical head.

Dynamic Response of Blade Surface Cavitation

  • Toyoshima, Masakazu;Sakaguchi, Kimiya;Tsubouchi, Kota;Horiguchi, Hironori;Sugiyama, Kazuyasu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.160-168
    • /
    • 2016
  • In high speed turbopumps, cavitation occurs and often causes the flow instabilities such as cavitation surge and rotating cavitation. The occurrence of these cavitation instabilities is considered to relate to dynamic characteristics of the cavitation, which are modelled using a cavitation compliance and a mass flow gain factor. Various types of cavitation such as a blade surface cavitation, a tip leakage vortex cavitation, and a backflow vortex cavitation occur at the same time in the inducer and the dynamic characteristics of each cavitation have not been clarified yet in experiments. Focusing on the blade surface cavitation as one of fundamental cavitation, we investigated the dynamic characteristics of the blade surface cavitation on a flat plate hydrofoil in experiments in the present study.

전동차용 모터 냉각홴의 공력성능 향상 및 소음특성 (Aerodynamic Performance Enhancement and Noise of Cooling Fans for Driving Motor)

  • 강신형;박태춘;조남효
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.32-40
    • /
    • 1998
  • Aerodynamic performance of a cooling fan of driving motor was enhanced modifying the vane-shroud configuration. Performance of a target model was evaluated to obtain baseline data. The aerodynamic performance and sound pressure level were tested and measured with different numbers of vane of increased length. The tested models show high and stable performance and low values of specific noise level. The long vane-shroud structure induces more stable through flow and decreases the tip leakage flow, which contributes to the increases of performance and efficiency. The sound pressure level increases for the modified model, however, specific noise level decreases.

  • PDF