• Title/Summary/Keyword: Tip device

Search Result 211, Processing Time 0.031 seconds

Development and Evaluation of Tip Pinch Strength Measurement on a Paretic Hand Rehabilitation Device

  • Kim, Jung-Yeon;Cha, Ye-Rin;Lee, Sang-Heon;Jung, Bong-Keun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.1201-1216
    • /
    • 2017
  • In this study, we described the development of a methodology to measure tip-pinch strength on the paretic hand rehabilitation device and aimed to investigate reliability of the device. FSR sensors were embedded on the device, and tip pinch strength was estimated with data collected from the sensors using a developed equation while participants were demonstrating tip pinch. Reliability tests included inter-rater, test-retest, and inter-instrument reliability. B&L Engineering pinch gauge was utilized for the comparison. Thirty-seven healthy students participated in the experiment. Both inter-rater and test-retest reliability were excellent as Intraclass Correlation Coefficients (ICCs) were greater than 0.9 (p<0.01). There were no statistically significant differences in tip-pinch strengths. Inter-instrument reliability analysis confirmed good correlation between the two instruments (r = 0.88, p < 0.01). The findings of this study suggest that the two instruments are not interchangeable. However, the tip-pinch mechanism used in the paretic hand rehabilitation device is reliable that can be used to evaluate tip pinch strength in clinical environment and can provides a parameter that monitors changes in the hand functions.

A Study on Micro-Tip Fabrication by Plating and CMP (도금 및 CMP에 의한 Micro-Tip 제작 공정 연구)

  • Han, Myung-Soo;Park, Chang-Mo;Shin, Gwang-Soo;Ko, Hang-Ju;Kim, Doo-Gun;Hann, S-Wook;Kim, Seon-Hoon;Ki, Hyun-Chul;Kim, Hyo-Jin;Kim, Jang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.152-152
    • /
    • 2009
  • We investigate micro-tip properties as Ni-Co plating and CMP processes for MEMS probe card and units. The micro-tip are fabricated by using Ni-Co plating machine, lapping machine, and chemo-mechanical polisher. In order to get high conductive and reliable micro-tip, we control Co contents and thickness by CMP speed. We have found that about 20-25% of Co contents are required and have to lapping speed of 30 rpm. Also, we investigate photolithography and Ni-Co plating processes conditions for the one-step and the three-step micro-tips.

  • PDF

Fabrication of Cone-shaped Si Micro-tip Reflector Array for Alternating Current Thin Film Electroluminescent Device Application (교류 구동형 박막 전계 발광 소자용 원추형 Si micro-tip 반사체 어래이의 제작)

  • Ju, Byeong-Gwon;Lee, Yun-Hui;O, Myeong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.662-664
    • /
    • 1999
  • We fabricated AC-TFEL device having cone-shaped Si micro-tip reflector array based on the process which have been conventionally employed for the Si-tip field emitter array in FED system. As a result, the AC-TFEL device having a new geometrical structure could generate well concentrated visible white-light from 3600 reflectors/pixel under bipolar pulse excitation mode only by edge-emission mechanism.

  • PDF

Root surface roughness following mechanical instrumentation in vivo and in vitro SEM study (기구조작후 치근표면의 조도에 관한 연구; 주사전자현미경적 in vivo 및 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.809-822
    • /
    • 1998
  • Adequate root preparation in the treatment of periodontal disease often involves mechanical instrumentation to remove plaque, calculus perhaps contaminated cementum. Although meticulous scaling and root planing may remove some cementum, the use of aggressive root planing to remove cementum does not appear warranted. So ultrasonic device and rotary instrument appear to be replacing hand instrument. But it is not clear those instruments make smooth root surface as hand instrument. The roghness of the root surface were evaluate with SEM following instrumentation with Gracey curette, Perio Clean and piezo ultrasonic device(Setlec) with various tip. 20 extracted teeth were used in vitro experiment, and 9 teeth of a patient destined for extraction for periodontal reasons were utilized in vivo experiment. It was demonstrated that hand curette created the smoothest surface, while diamond tip tended to roughen the root surface. But the hand curette, Perio Clean, and piezo ultasonic device with scaler tip tend to remove cementum completely. Piezo ultrasonic device with curette-like tip made the desirable smooth surface with partial removal of cementum.

  • PDF

An Experimental Study on the Lift and Drag Characteristics of a Wing with a Helical Ring Wing Tip (나선 고리형 날개끝을 가진 날개의 양항특성에 관한 실험적 연구)

  • Lim, J.H.;Lee, B.J.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.6 no.1
    • /
    • pp.7-20
    • /
    • 1998
  • A reduction of induced drag is an important problem in order to save fuels. In this study, the aerodynamic characteristics of wing tip devices to reduce induced drag, such as end plate, plain ring, helical ring wing tip device, was experimentally investigated in a low speed wind tunnel. The experimental results showed that the wing model with a helical ring wing tip device reduced a induced drag and increased lift-drag ratio.

  • PDF

Design and Control of a Wire-driven Haptic Device;HapticPen

  • Farahani, Hossein S.;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1662-1667
    • /
    • 2005
  • In this paper, analysis, design, control and prototype construction of a wearable wire-driven haptic interface called HapticPen is discussed. This device can be considered as a wire driven parallel mechanism which three wires are attached to a pen-tip. Wire tensions are provided utilizing three DC servo motors which are attached to a solid frame on the user's body. This device is designed as input as well as output device for a wearable PC. User can write letters or figures on a virtual plate in space. Pen-tip trajectory in space is calculated using motor encoders and force feedback resulting from contact between pen and virtual plate is provided for constraining the pen-tip motion onto the virtual plane that can be easily setup by arbitrary non-collinear three points in space. In this paper kinematic model, workspace analysis, application analysis, control and prototype construction of this device are presented. Preliminary experiments on handwriting in space show feasibility of the proposed device in wearable environments.

  • PDF

Root surface roughness following mechanical instrumentation, in vitro 3 dimensional planimetric study (기구조작후 치근표면의 조도에 관한 연구; 3차원 측정기틀 이용한 in vitro 연구)

  • Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.823-828
    • /
    • 1998
  • A primary goal of periodontal therapy is the creation of root surfaces that are free of plaque and calculus. It is not yet to be determined whether it is desirable to have a smooth root surface after treatment. It is also not clear what degree of roughness result from different instruments. In the present study various instruments for root surface debridement were evaluated. 20 extracted teeth were utilized, and the teeth were treated with one of the following instrument: Gracey curette, Perio Clean, and piezo ultrasonic device(Setlec, P Max) with general scaler tip, curette-like tip, and diamond tip. 3 dimensional planimetric device(Accura) was used to evaluate the average surface roughness. It was demonstrated hand and power-driven instruments did not have a significant difference in roughness of the root surface following instrumentation. And ultrasonic scaler tip tended to make a most smooth surface than other instruments. The possible reasons of the result were discussed.

  • PDF

Etching Treatment of Vertically Aligned Carbon Nanotubes for the Application to Biosensor (바이오센서로의 응용을 위한 수직 배열된 탄소나노튜브의 식각처리)

  • Choi, Eun-Chang;Park, Yong-Seob;Choi, Won-Seok;Hong, Byung-You
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.7
    • /
    • pp.594-598
    • /
    • 2008
  • The metal catalyst particles which there is as impurities on a tip part of carbon nanotube (CNT) are not good to apply it to a nano-electronic device. It was very important the opening of CNT-tip to fix a target bio material and a material to accept in CNT in a biosensor, so we performed $HNO_3$ wet etching to remove the metal catalyst particle which there was on a tip part of CNT grown up in the study and observed the opened CNT-tip with etching time. We synthesized the CNTs using a HF-PECVD method and choses the CNT length of 700 nm for the application of nano-electronic device such as a biosensor etc.. We observed the opened CNT-tip with wet etching times of $HNO_3$ (10, 30, 60 min). From the results, we observed that the CNT-tip was opened with the increase of wet etching time lively. In case of CNTs etched during 60 min, we confirmed that there was not the ratio of Ni included in CNTsI as catalyst. Conclusively, in the case of CNT etched for 60 minutes, it is completely good for application of a biosensor and, in addition, the metal-free CNTs will contribute to the application of other nanoelectronic devices.

Decrease of Gate Leakage Current by Employing AI Sacrificial Layer in the DLC-coated Si-tip FEA Fabrication (DLC-coated Si-tip FEA 제조에 있어서 Al 희생층을 이용한 게이트 누설 전류의 감소)

  • Ju, Byeong-Kwon;Lee, Sangjo;Kim, Hoon;Lee, Yun-Hi;Oh, Myung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.8
    • /
    • pp.577-579
    • /
    • 1999
  • DLC film remaining on device surface could be removed by eliminating AI sacrificial layer as a final step of lift-off process in the fabrication of DLC-coated Si-tip FEA. The field emission properties(I-V curves, hysteresis, and current fluctuation etc.) of the processed device were analyzed and the process was employed to 1.76 inch-sized FEA panel fabrication in order to evaluate its FED applicability.

  • PDF

TIP Technique using the OpenGL ES for android platform (OpenGL ES 를 이용한 Android Platform 에서의 TIP 기술)

  • Lee, Junho;Jang, Minseok;Lee, Yonsik
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.330-333
    • /
    • 2011
  • TIP 기술은 2D 그림 또는 한 장의 사진으로부터 기하정보를 추출하여 3 차원 입체 효과를 만들어 영상 내부를 네비게이션할 수 있는 기술로써, 게임, 엔터테인먼트, 교육, 홍보 등 다양한 분야에서 요구되는 주요기술이다. 본 논문에서는 최근 대두되고 있는 스마트 device 의 platform 가운데 하나인 android platform 상에서의 OpenGL ES Library 를 이용한 TIP 기술 적용 및 구현 기술을 제안한다. 제안 방법은 전경객체의 추출이 어려운 상황을 감안하여 보다 사실적 장면 구성이 용이하도록 사용자의 선택에 의한 소실점을 이용하고, OpenGL ES Library 를 이용하여 3D 배경 모델을 획득하고, 이미지를 텍스쳐 매핑하여 3D 가상공간을 완성한 후 카메라의 시점 변환을 통해 이미지 내부를 네베게이션할 수 있도록 한다. 실험영상은 android platform 상의 device 에서 촬영한 이미지를 사용하고, android 2.1 및 OpenGL ES 1.0 기반으로 구축함으로써, 제안 기술을 다양한 android platform smart device 에서 적은 비용과 시간으로 응용 개발에 효과적으로 적용 가능하도록 구현하였다.