• Title/Summary/Keyword: Tip clearance characteristic

Search Result 7, Processing Time 0.02 seconds

Numerical investigations of tip clearance flow characteristics of a pumpjet propulsor

  • Lu, Lin;Gao, Yuefei;Li, Qiang;Du, Lin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.3
    • /
    • pp.307-317
    • /
    • 2018
  • In this study, numerical investigations of the tip clearance flow characteristics of a pumpjet propulsor based on Computational Fluid Dynamics (CFD) method have been presented. The Zwart-Gerber-Belamri (Z-G-B) cavitation model based on Reynolds Averaged Navier-Stokes (RANS) method is employed. The structured gird is applied. The formation and development of the tip clearance flows has been investigated and presented. The structure of the tip leakage vortex has been shown. The radial distributions of different velocity components with different Span along the axial direction have been carried out to present the influence of the tip clearance flow on the main flow. In addition, the influences of the tip clearance size on the pumpjet propulsor performance, including the impact on the velocity flow fields and the cavitation characteristic, have been presented.

Effects of Asymmetric Tip Clearance on Centrifugal Compressor Flow (비대칭 팁간극이 원심압축기의 유동에 미치는 영향)

  • Yoon, Yong-Sang;Song, Seung-Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.533-541
    • /
    • 2005
  • Compared to axial compressors, an analytical model capable of analyzing the flow in centrifugal compressor lacks because of the difficulty in governing equations for radial duct. Therefore, this paper presents a new model to predict flow field in a centrifugal compressor with a sinusoidal asymmetric tip clearance. To predict the 2 dimensional flow in the inlet and exit of the centrifugal compressor, the two flow fields are connected with compressor characteristic based on Moore-Greitzer model. Contrary to axial compressors, the nonuniformity of impeller exit pressure in centrifugal compressor decreases as flow coefficient decreases. In addition, that is sensitive to the slope of pressure rise by eccentricity. The maximum velocity exists right before the maximum tip clearance.

  • PDF

Vortex Features in a Half-ducted Axial Fan with Large Bellmouth (Effect of Tip Clearance)

  • Shiomi, Norimasa;Kinoue, Yoichi;Setoguchi, Toshiaki;Kaneko, Kenji
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.307-316
    • /
    • 2011
  • In order to clarify the features of tip leakage vortex near blade tip region in a half-ducted axial fan with large bellmouth, the experimental investigation was carried out using a 2-dimensional LDV system. Three sizes of tip clearance (TC) were tested: those sizes were 1mm (0.55% of blade chord length at blade tip), 2mm (1.11% of blade chord length at blade tip) and 4mm (2.22% of blade chord length at blade tip), and those were shown as TC=1mm, TC=2mm and TC=4mm, respectively. Fan characteristic tests and the velocity field measurements were done for each TC. Pressure - flow-rate characteristics and two-dimensional velocity vector maps were shown. The vortex trace and the vortex intensity distribution were also illustrated. As a result, a large difference on the pressure - flow-rate characteristics did not exist for three tip clearance sizes. In case of TC=4mm, the tip leakage vortex was outflow to downstream of rotor was not confirmed at the small and reference flow-rate conditions. Only at the large flow-rate condition, its outflow to downstream of rotor existed. In case of TC=2mm, overall vortex behaviors were almost the same ones in case of TC=4mm. However, the vortex trace inclined toward more tangential direction. In case of TC=1mm, the clear vortex was not observed for all flow-rate conditions.

Performance Assessment of Turbulence Models for the Prediction of Tip Leakage Flow in an Axial-flow Turbomachinery (축류형 유체 기계에서 팁 누설 유동 해석을 위한 난류 모델 성능 비교)

  • Lee, Gong-Hee;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2162-2167
    • /
    • 2003
  • It is well-known that high anisotropic characteristic of turbulent flow field is dominant inside tip leakage vortex. This anisotropic nature of turbulence invalidates the use of the conventional isotropic eddy viscosity turbulence model based on the Boussinesq assumption. In this study, to check whether an anisotropic turbulence model is superior to the isotropic ones or not, the results obtained from steady-state Reynolds averaged Navier-Stokes simulations based on the RNG ${\kappa}-{\varepsilon}$ and the Reynolds stress model in two test cases, such as a linear compressor cascade and a forward-swept axial-flow fan, are compared with experimental data. Through the comparative study of turbulence models, it is clearly shown that the Reynolds stress model, which can express the production term and body-force term induced by system rotation without any modeling, should be used to predict the complex tip leakage flow, including the locus of tip leakage vortex center, quantitatively.

  • PDF

A Numerical Analysis and Experiment for Micro-Fans (축류 마이크로 홴의 전산해석 및 성능시험)

  • Cho, Jin-Soo;Pyun, Tae-Kyoon;Park, Wang-Sik;Chun, Chang-Kun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

A study on the prediction of punch wear level through analysis of piercing load of aluminum (알루미늄 홀 가공 하중 분석을 통한 펀치 마모수준 예측에 관한 연구)

  • Yong-Jun Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.46-51
    • /
    • 2022
  • The piercing process of creating holes in sheet metals for mechanical fastening generates high shear force. Real-time monitoring technology could predict tool damage and product defects due to this severe condition, but there are few applications for piercing high-strength aluminum. In this study, we analyzed the load signal to predict the punch's wear level during the process with a piezoelectric sensor installed piercing tool. Experiments were conducted on Al6061 T6 with a thickness of 3.0 mm using piercing punches whose edge angle was controlled by reflecting the wear level. The piercing load increases proportionally with the level of tool wear. For example, the maximum piercing load of the wear-shaped punch with the tip angle controlled at 6 degrees increased by 14% compared to the normal-shaped punch under the typical clearance of 6.7% of the aluminum piercing tool. In addition, the tool wear level increased compression during the down-stroke, which is caused by lateral force due to the decrease in the diameter of pierced holes. Our study showed the predictability of the wear level of punches through the recognition of changes in characteristic elements of the load signal during the piercing process.

An Analysis on the Vibration Characteristic of a Automobile at the Sudden Change of an Accelerator under Traveling (주행중 가속페달의 급조작시 승용차의 진동 특성 해석)

  • 홍동표;정태진;김상수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.76-81
    • /
    • 1994
  • 승용차에 있어 엔진의 공회전시나 주행중에 발생하는 여러 형태의 진동 및 소음의 저감은 승차감 및 차량의 안정성에 있어 중요한 과제가 되고 있다. 이러한 소음, 진동은 주로 엔진에서 발생하는 토크의 비주기적인 변동성분이 클러치(clutch), 변속기(transmission), 구동축을 거쳐 바퀴로 전달되는 과정에서 발생한다. 셔플(shuffle)은 주행중 가속페달(accelerator)을 급조작(tip-in, tip-out)하였을 때 차량이 전후로 과도적으로 울렁거리는 종진동 현상을 말하며, 이것은 가속페달의 급조작으로 인해 엔진토크가 큰 변동을 일으키고, 동력전달계를 통해 타이어에 전달된 이 토오크는 타이어축에서 구동측으로 역토오크를 발생시키기 때문에 발생한다. 여기서 팁-인(tip-in)이란 승용차를 저속으로 운전하다가 갑자기 가속페달을 밟는 경우를 말하며, 팁-아웃(tip-out)은 반대로 고속상태에서 갑자기 가속페달을 떼는 경우를 말한다. 실험과 시뮬레이션을 사용한 자동차 동력전달계의 비틀림 진동에 대한 연구는 이미 여러 연구자들에 의해 보고되었다. H.Arai은 2자유도 비선형 모델을 사용하여 클러치 접속시 발생하는 외란과 계의 안정성을 고려하여 시뮬레이션을 수행하였고, M.Kataoka는 기어의 공차(clearance)를 고려한 변속기의 강제 비틀림 진동을 실험과 시뮬레이션을 통하여 해석하였다. 그리고, Wu Hui-Le는 자동차 동력전달계의 비틀림 진동 현상을 실험과 이론적인 계산을 통해 연구하였고, R.J.Comparin는 치타음의 발생구조와 특성을 고찰하고 비서형 비틀림 공진 저감에 의한 치타음 저감 기법에 대하여 연구하였다. 또한 G.J.Fudala는 다자유도 모델을 이용하여 클러치의 비틀림 특서엥 따라 주파수분석을 수행하여 치타음 저감 방법을 연구하였고, T.Sakai는 5자유도 모델을 이용하여 엔진 공회전시 발생하는 치타음에 대해 이론과 실험을 통해 해석하고, 엔진 회전수 변동, 클러치 특성, 변속기의 드래그(drag) 토크의 영향과 치타음 저감을 위한 개선된 클러치 특성을 제시하였다. 이 외에도 Thomas C.T.와 E.P.Petkus는 특정 차량에 대한 동력전달계의 비틀림 진동 현상에 대해 연구하였다. 이러한 연구들로 볼 때, 자동차 동력전달계에서 발생하는 진동은 이론과 실험을 통해 그 해석이 가능하며 설계에 매우 유용하게 이용되고 있음을 알 수 있다. 따라서, 본 연구는 4 실린더 4 싸이클 1.5 L 엔진을 장착한 경승용차의 실차 주행실험을 통해 가속 페달의 급조작에 따른 차체의 종진동 현상을 측정하고, 엔진-변속기-타이어-차체의 반환정계 4자유도 진동모델로 시뮬레이션을 수행하여 실차 주행실험의 결과치와 비교, 분석한 후 클러치 비틀림 특성을 비롯한 자동차 동력전달계의 각 설계인자들이 차체의 종진동에 어떠한 영향을 미치는가를 해석하고자 한다.

  • PDF