• 제목/요약/키워드: Time-to-Detect

검색결과 3,769건 처리시간 0.035초

IL-12 Regulates B7-H1 Expression in Ovarian Cancer-associated Macrophages by Effects on NF-κB Signalling

  • Xiong, Hai-Yu;Ma, Ting-Ting;Wu, Bi-Tao;Lin, Yan;Tu, Zhi-Guang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권14호
    • /
    • pp.5767-5772
    • /
    • 2014
  • Background and Aim: B7-H1, a co-inhibitory molecule of the B7 family, is found aberrantly expressed in ovarian cancer cells and infiltrating macrophage/dendritic-like cells, and plays a critical role in immune evasion by ovarian cancer. IL-12, an inducer of Th1 cell development, exerts immunomodulatory effects on ovarian cancer. However, whether IL-12 regulates B7-H1 expression in human ovarian cancer associated-macrophages has not been clarified. Therefore, we investigated the effects of IL-12 on the expression of B7-H1 in ovarian cancer-associated macrophages and possible mechanisms. Methods: PMA induced THP-1-derived macrophages or human monocyte-derived macrophages were treated with recombinant IL-12 (rIL-12) or infected with adenovirus carrying human IL-12 gene (Ad-IL-12-GFP) for 24 h, then cocultured with the SKOV3 ovarian cancer cell line for another 24 h. Macrophages were collected for real-time PCR and Western blot to detect the expression of B7-H1, and activation of the NF-${\kappa}B$ signaling pathway. Moreover, supernatants were collected to assay for IL-12, IFN-${\gamma}$ and IL-10 by ELISA. In addition, monocyte-derived macrophages treated with IFN-${\gamma}$ were cocultured with SKOV3 and determined for the expression of B7-H1. Furthermore, the expression of B7-H1 in monocyte-derived macrophages was also evaluated after blocking NF-${\kappa}B$ signaling. Results: The expression of B7-H1 was significantly upregulated in monocyte-derived macrophages treated with rIL-12 or Ad-IL-12-GFP compared with the control groups (p<0.05), accompanied by a remarkable upregulation of IFN-${\gamma}$ (p<0.05), a marked downregulation of IL-10 (p<0.05) and activation of NF-${\kappa}B$ signaling. However, the upregulation of B7-H1 was inhibited by blocking the NF-${\kappa}B$ signaling pathway (p<0.05). Expression of B7-H1 was also increased (p<0.05) in monocyte-derived macrophages treated with IFN-${\gamma}$ and cocultured with SKOV3. By contrast, the expression of B7-H1 in THP-1-derived macrophages was significantly decreased when treated in the same way as monocyte-derived macrophages (p<0.05), and IL-10 was also significantly decreased but IFN-${\gamma}$ was almost absent. Conclusions: IL-12 upregulates the expression of B7-H1 in monocyte-derived macrophages, which is possible though inducing the secretion of IFN-${\gamma}$ and further activating the NF-${\kappa}B$ signal pathway. However, IL-12 downregulates the expression of B7-H1 in THP-1-derived macrophages, associated with a lack of IFN-${\gamma}$ and inhibition of expression of IL-10.

낙농산업에 필요한 미생물 검사방법과 전망: 총설 (Perspective on Rapid and Selective Method for Detecting Microbiology in Dairy Industry: A Review)

  • 천정환;김현숙;김홍석;김동현;송광영;임진혁;최다솜;임종수;정동관;김수기;서건호
    • Journal of Dairy Science and Biotechnology
    • /
    • 제33권2호
    • /
    • pp.119-127
    • /
    • 2015
  • 낙농 미생물학에서 사용하는 주요 분석 방법들에 대한 지속적인 개정이 요구되어지고 있는 것이 사실이다. 현재 이용 가능한 자료들을 바탕으로 균주의 생리 및 대사 특성을 더 깊이 이해할 수 있으며, LAB와 probiotic 생리적 상태를 측정할 수 있는 기술을 개발할 수 있다. 예를 들어, 고유 균주의 생화학 반응으로부터 얻은 생물학적 생리학적 지식을 바탕으로 발색형광배지(chromogenic media)의 개발이 가능하다. 이 기술은 오랫동안 사용되어온 한천 배지보다 사용법이 간단하며, 미생물을 제어할 수 있다. 유망한 유동세포계수법(flow cytometry, FC) 기술은 우유, 요구르트, 그 외 발효 유제품의 혼합 배양의 분석에 뛰어나다. 이 기술은 공정 과정 중에 또는 생산품의 유통 기한 관리에 사용될 수 있지만, 이 기술을 사용하기 위해서는 우유 단백질에 의해서 생성되는 인공 산물을 방지하기 위해 최적화 되어야 한다. 또한 유동세포계수법(flow cytometry, FC)은 정량 한계가 높기 때문에, 현재 사용하고 있는 탐침(probe)은 종 또는 속이 아닌 표적 세포 구성을 분석한다. 따라서 유동세포계수법(flow cytometry, FC)은 특정 물질의 계수보다는 생리적 상태를 측정에 더 적합한 기술이라고 볼 수 있다. Omics 자료를 통해 생리적 상태를 더 신속하게 측정할 수 있는 핵심적인 생체지표 확인이 가능해졌다. PCR은 이미 식품매개 병원균 및 부패균의 검출에 일상적으로 사용되고 있다. 이 기술은 더욱 나아가 발효균 및 probiotic 박테리아 검출에도 사용되어 핵산 추출, PCR 과정, 자료 해석을 표준화 시킬 수 있으며, 또한 다른 기술에 비해 PCR은 표적 발효 균주를 더 신속하게 선택하며, 공정 과정을 최적상태로 유지시킬 수 있을 것이다. LAB와 probiotic의 적응성 및 생리적 상태의 연구에 필요한 기준, 특허품, 상업화된 신속분석장치(kit)는 아직까지 개발되지 않았다. 본 총설 논문에서는 여러 가지 기술을 검토함으로써 이 모든 기술에는 2가지 주요한 요인이 있다. 첫 번째는 낙농업 산업의 특정 요구에 따른 방법의 평가이며, 두 번째는 공식적인 기준에 따른 검증이다. 사실상 식품매개 병원균의 특성 분석에 사용될 수 있는 표준법이 개발되고 검증되었지만, LAB, probiotic 등의 박테리아 분석에 있어서 표준화된 방법과 진단산업과의 연관성이 부족한 것이 사실이다. 낙농 업계에 의해서 수행되어진 품질관리의 양을 고려해 볼 때 이것은 매우 중요하게 인식되어야 할 부분이다.

  • PDF

카테고리 연관 규칙 마이닝을 활용한 추천 정확도 향상 기법 (A Study on the Improvement of Recommendation Accuracy by Using Category Association Rule Mining)

  • 이동원
    • 지능정보연구
    • /
    • 제26권2호
    • /
    • pp.27-42
    • /
    • 2020
  • 인터넷이라는 가상 공간을 활용함으로써 물리적 공간의 제약을 갖는 오프라인 쇼핑의 한계를 넘어선 온라인 쇼핑은 다양한 기호를 가진 소비자를 만족시킬 수 있는 수많은 상품을 진열할 수 있게 되었다. 그러나, 이는 역설적으로 소비자가 구매의사결정 과정에서 너무 많은 대안을 비교 평가해야 하는 어려움을 겪게 함으로써 오히려 상품 선택을 방해하는 원인이 되기도 한다. 이런 부작용을 해소하기 위한 노력으로서, 연관 상품 추천은 수많은 상품을 다루는 온라인 상거래에서 소비자의 구매의사결정 과정 중 정보탐색 및 대안평가에 소요되는 시간과 노력을 줄여주고 이탈을 방지하며 판매자의 매출 증대에 기여할 수 있다. 연관 상품 추천에 사용되는 연관 규칙 마이닝 기법은 통계적 방법을 통해 주문과 같은 거래 데이터로부터 서로 연관성 높은 상품을 효과적으로 발견할 수 있다. 하지만, 이 기법은 거래 건수를 기반으로 하므로, 잠재적으로 판매 가능성이 높을지라도 충분한 거래 건수가 확보되지 못한 상품은 추천 목록에서 누락될 수 있다. 이렇게 추천 시 제외된 상품은 소비자에게 구매될 수 있는 충분한 기회를 확보하지 못할 수 있으며, 또 다시 다른 상품에 비해 상대적으로 낮은 추천 기회를 얻는 악순환을 겪을 수도 있다. 본 연구는 구매의사결정이 결국 상품이 지닌 속성에 대한 사용자의 평가를 기반으로 한다는 점에 착안하여, 추천 시 상품의 속성을 반영하면 소비자가 특정 상품을 선택할 확률을 좀더 정확하게 예측할 수 있다는 점을 추천 시스템에 반영하기 위한 목적으로 수행되었다. 즉, 어떤 상품 페이지를 방문한 소비자는 그 상품이 지닌 속성들에 어느 정도 관심을 보인 것이며 추천 시스템은 이런 속성들을 기반으로 연관성을 지닌 상품을 더 정교하게 찾을 수 있다는 것이다. 상품의 주요 속성의 하나로서, 카테고리는 두 상품 간에 아직 드러나지 않은 잠재적인 연관성을 찾기에 적합한 대상이 될 수 있다고 판단하였다. 본 연구는 연관 상품 추천에 상품 간의 연관성뿐만 아니라 카테고리 간의 연관성을 추가로 반영함으로써 추천의 정확도를 높일 수 있는 예측모형을 개발하였고, 온라인 쇼핑몰로부터 수집된 주문 데이터를 활용하여 이루어진 실험은 기존 모형에 비해 추천 성능이 개선됨을 보였다. 실무적인 관점에서 볼 때, 본 연구는 소비자의 구매 만족도를 향상시키고 판매자의 매출을 증가시키는 데에 기여할 수 있을 것으로 기대된다.

지뢰탐지를 위한 GPR 시스템의 개발 (GPR Development for Landmine Detection)

  • Sato, Motoyuki;Fujiwara, Jun;Feng, Xuan;Zhou, Zheng-Shu;Kobayashi, Takao
    • 지구물리와물리탐사
    • /
    • 제8권4호
    • /
    • pp.270-279
    • /
    • 2005
  • 일본 문부과학성의 연구 지원하에 지뢰 탐지를 위한 GPR 시스템 개발에 관한 연구를 수행하였다. 2005 년도까지 두 종류의 새로운 지뢰탈지 GPR 시스템 원형의 개발을 완성하였으며 이를 ALIS (Advanced Landmine Imaging System)와 SAR-GPR (Synthetic Aperture Radar-Ground Penetrating Radar)이라고 명명하였다. ALIS는 금속탐지기와 GPR을 결합한 새로운 형태의 휴대용 지뢰탐지 시스템이다. 센서의 위치를 실시간으로 추적하는 시스템을 장착하여 센서에 감지된 신호를 실시간으로 영상화할 수 있도록 하였으며, 센서 위치의 추적은 센서의 손잡이에 장착한 CCD 카메라만을 이용하여 가능하도록 고안하였다. 그리고 GPR과 금속탐지기 신호를 CCD 카메라에 포착된 영상에 중첩하여 동시에 영상화하도록 설계하였기 때문에 매설된 탐지 목적물을 용이하게 그리고 신뢰할 만한 수준으로 탐지하고 구별할 수 있다. 2004년 12월에 아프가니스탄에서 ALIS의 현장 검증 실험을 수행하였으며, 이를 통해 이 연구에서 개발한 시스템을 이용하여 매설된 대인지뢰를 탐지할 수 있을 뿐만 아니라 대인지뢰와 금속 파편의 구분 또한 가능함을 보였다. SAR-GPR은 이동 로보트에 장착한 지뢰탐지 시스템으로 GPR과 금속탐지기 센서로 구성된다. 다수의 송, 수신 안테나로 구성된 안테나 배열을 채택하여 개선된 신호처리 기법의 적용을 가능하며, 이를 통해 좀 더 나은 지하 영상의 획득이 가능하다. SAR-GPR에 합성개구 레이다 알고리듬을 채용함으로써 원하지 않는 클러터(clutter)신호를 억제하고 불균질도가 높은 매질 내부에 매설된 목적물을 영상화할 수 있다. SAR-GPR은 새로이 개발한 휴대용 벡터 네트워크 분석기를 이용한 스텝 주파수 레이다 시스템(stepped frequency radar system)으로 6 개의 Vivaldi 안테나와 3 개의 벡터 네트워크 분석기로 구성된다. SAR-GPR의 크기는 $30cm{\times}30cm{\times}30cm$, 중량은 17 kg 정도이며 소형 무인 차량의 로보트 팔에 장착된다. 이 시스템의 현장 적용 실험은 2005 년 3 월 일본에서 성공적으로 실시된 바 있다.

황촉규근(黃蜀葵根) 점액(粘液)에 관(關)한 연구(硏究) -[제1보(第一報)] 점액(粘液)의 점성(粘性) 및 유리당(遊離糖)- (Studies on the Mucilage of the Root of Abelmoschus manihot, MEDIC -[Part I] Viscosity and Free Sugars in the Mucilage-)

  • 온두현;임재빈;손주환
    • Applied Biological Chemistry
    • /
    • 제19권1호
    • /
    • pp.36-40
    • /
    • 1976
  • 본(本) 연구(硏究)에서 얻은 결과(結果)를 다음에 요약(要約)한다. 1. 황촉규근(黃蜀葵根) 점액(粘液)은 유리환원당(遊離還元糖)을 함유(含有)한다. 이것의 함량(含量)은 경시적(經時的)으로 변화(變化)하며 함량(含量)이 최고(最高)에 달(達)하는 시간(時間)은 온도(溫度), 침출수량등(浸出水量等)의 영향(影響)으로 일정(一定)하지 않다. 2. 황촉규근(黃蜀葵根) 점액(粘液)의 점도(粘度)도 경시적(經時的)으로 감퇴(減退)하며 이것의 점성(粘性)은 점액내(粘液內) 유리당(遊離糖)의 함량(含量)과 약간(若干)의 상관관계(相關關係)가 있어 일반(一般)으로 점도(粘度)가 큰 점액(粘液)의 당함량(糖含量)은 크다. 그리고 점액(粘液)의 점도(粘度)는 경시적(經時的)으로 급격(急激)하게 감퇴(減退)되나 당함량(糖含量)은 서서히 감소(減少)한다. 3. 황촉규근(黃蜀葵根) 점액(粘液)은 표피(表皮)에서 많이 분비(分泌)되며 이 점액(粘液)은 목질부(木質部) 분비(分泌)된 점액(粘液)보다 점도(粘度)가 크고 유리당(遊離糖)의 함량(含量)이 크다. 4. mixer처리(處理)로 점액(粘液)의 점도(粘度)는 크게 감퇴(減退)하나 당함량(糖含量)에는 큰 변화(變化)가 없다. 5. 점액(粘液)의 점도저하(粘度低下)는 ammonium sulfate의 첨가(添加)로 효과적(效果的)으로 방지(防止)할 수 있다. 그러나 이 경우의 유리당(遊離糖) 함량(含量)은 비교적(比較的) 적고, starch-iodine반응(反應)은 30일(日)이 경과(經過)한다 할지라도 양성(陽性)이다. 뒤의 여러 결과(結果)로 미루어 점액(粘液)의 점성(粘性)의 불안정성(不安定性)은 화학적(化學的), 물리적(物理的) 요인외(要因外)에 미생물학적(微生物學的) 요인(要因)이 복합(複合)되어 관련(關聯)될 것이라 추측(推測)된다.達)한 바 있으나 여기에서 점질물(粘質物)의 구성성분(構成成分)으로 glucose, ribose 등(等)이 관여(關與)할 것이라는 새로운 사실(事實)이 관찰(觀察)되었다. glucose는 점액(粘液) 그리고 모든 가수분해(加水分解) 생성물(生成物)에서 분리(分離), 동정(同定)되나 ribose는 점질물(粘質物)을 제거(除去)한 여액(濾液)의 가수분해(加水分解) 생성물(生成物)에서 분리(分離), 동정(同定)되고 약간(若干)의 시일(時日)이 경과(經過)한다 할지라도 동일(同一)한 결과(結果)를 보인다. 또 여기에서 더욱 검토(檢討)하여야 할 미지물질(未知物質)의 존재(存在)도 관찰(觀察)되었다. 4. 따라서 황촉규근(黃蜀葵根) 점액(粘液) 및 점질물(粘質物)의 구성(構成) 성분(成分)으로 확인(確認)된 당류(糖類)는 rhamnose, xylose, arabinose, galactose, glucose, ribose와 uronic acid 등(等)이며 이밖에 미지(未知)의 물질(物質)도 확인(確認)되었다. 그러므로 점질물(粘質物)의 본태(本態)는 이들이 결합(結合)히여 이루어진 복합당(複合糖)일 것으로 추측(推測)된다.有率)이 그 지방(地方)의 비추락지(非秋落地)에서보다 낮았고 소사(素砂)에서는 철(鐵), 평택(平澤)에서는 유기물(有機物)의 함유율(含有率)이 추락도(秋落稻)에서 높았다. (5) 상층토전체(上層土全體)에 함유(含有)되어 있는 각주요무기성분(各主要無機成分)의 전량(全量)에 대(對)하여 각(各) 지구(地區)를 통관(通觀)한 추락(秋落)과의 관계(關係)에 어떤 일정(一定)한 경향(傾向)을 인정(認定)할 수 없었으나 지구별단위(地區別單位)에 있어서는 질소(窒素) 그밖에 모든 성분(成分)에 있어서 차이(差異)가 있음을 인정(認定)할 수 있었다. 3. 수확물(收穫物)의 화학적(化學的)

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Phthalimido methyl-O,O-dimethyl phosphorodithioate (Imidan)과 그의 대사물질(代謝物質)이 수도(水稻) 생육(生育)에 미치는 영향(影響)에 관(關)한 연구(硏究) (Studies on the effect of phthalimido methyl-O,O-dimethyl-phosphorodithioate (Imidan) and its possible metabolites on the growth of rice plant)

  • 이성환;이동석;이재구
    • Applied Biological Chemistry
    • /
    • 제7권
    • /
    • pp.105-117
    • /
    • 1966
  • acaricide로 알려진 phthalimidomethyl O,O-dimethyl phosphorodithioat (Imidan)을 수도(水稻)에 살포(撒布)했을 때 Imidan과 그 대사물질(代謝物質)이 식물(植物)의 생육(生育)에 미치는 영향(影響)을 연구(硏究)하기 위하여 본(本) 실험(實驗)을 하였으며 이의 결과(結果)를 요약(要約)해 보면 다음과 같다. (1) Imian의 대사물질(代謝物質)로 예상(豫想)되는 다음의 8가지 화합물(化合物)을 합성(合成) 또는 정제(精製)하여 공시약제(供試藥劑)로 사용(使用)하였다. (a) N-Hydroxy methyl phthalimide (b) Phalimide (c) Phthalamdic acid (d) Phthalic acid (e) Anthranilic acid (f) p-amino benzoic acid (g) p-hydroxu benzoic acid (h) Benzoic acid (2) 상기(上記) 물질중(物質中)에서 (a),(c),(d),(e)와 Imidan의 각(各) 10 ppm과 20 ppm 의 Buffer Solution 을 만들어 밀 종자(種子)를 가지고 coleoptile straight growth test를 해 본 결과(結果) Imidan 은 10 ppm 과 20 ppm에서 모두 control 보다 생장(生長)의 촉진효과(促進?果)를 보였으며 기중(其中) phthalamidic acid 10 ppm 이 가장 좋은 성적(成績)을 보였다. 이것으로 보아 Imidan 자체(自體)는 생장(生長) 억제(抑制)의 효과(?果)를f 보이나 이것이 일단(一但) 생체내(生體內)에서 가수분해(加水分解)를 비롯한 각종(各種) 대사작용(代謝作用)을 받으면 그 대사산물(代謝産物)이 식물생장(植物生長)을 촉진(促進)하는 효과(?果)를 보이는 것 같다. (Table 1, Fig. 1 참조(參照)) (3) xylene을 용매(溶媒)로 하여 Imidan 유제(乳劑)를 만들고 이것을 희석(稀釋)하여 20 ppm, 100 ppm 및 200 ppm 의 각(各) 농도(濃度) 유화액(乳化液)을 조제(調製)한 후 이것을 배지(培地)로 하여 수도종자(水稻種子)를 발아(發芽)시킨 후 12 일(日)에 shoot와 root의 길이를 측정(測定)하였다. 이의 결과(結果)를 보면 root는 Imidan 20 ppm에서, shoot 는 Imidan 100 ppm에서 모두 xylene만의 유제구(乳劑區)인 control 보다 좋은 효과(?果)를 보였으며 여기에서 흥미(興味)있는 것은 용매(溶媒)로 사용(使用)된 xylene은 수도종자(水稻種子) 뿌리의 발육(發育)에 심(甚)한 억제효과(抑制效果)를 보이는 것 같다. (Table 2, Table 5 참조(參照)) (4) 벼를 pot에 심고 2회(回)에 걸쳐 control, Imidan, N-hydroxy methyl phthalimide, anthranilic acid 및 phthalimide의 10, 25, 50, 100 ppm 농도(濃度)의 각(各) 유제(乳劑)를 살포하고 일정기간후(一定期間後) 생육상(生育相)을 조사(調査)하였더니 Imidan 구(區)와 N-hydroxy methyl phthalimide 구(區)가 control 보다 좋은 성적(成績)을 보였다. (5) Imidan 250 ppm 유제(乳劑)를 수도엽면(水稻葉面)에 살포(撒布)하고 3 일(日), 5 일(日), 7 일(日) 및 14일후(日後)에 일정량(一定量)의 엽경(葉莖)을 채취(採取)하여 acetone으로 추출(抽出)k고 acetonitrile을 가지고 prechromatographic piriication 을 거쳐 paper chromatography에 의(依)하여 다음과 같은 대사물질(代謝物質)을 검출(檢出)하였다. Imidan $(Rf:\;0.97{\sim}0.98)$, N-hydroxy methyl phthalimide (Rf: 0.87), phthalimide $(Rf:\;0.86{\sim}0.87)$, phthalamidic acid $(Rf:\;0.13{\sim}0.14)$, phthalic acid $(Rf:\;0.02{\sim}0.03)$, benzoic acid $(Rf:\;0.42{\sim}0.43)$ 및 p-amino benzoic acid 또는 p-hydroxy benzoic acid $(Rf:\;0.08{\sim}0.09)$와 Rf=0.73, 0.59, 0.33, 0.23, 0.07의 미지물질(未知物質)을 검출(檢出)하였다. 또한 3일(日), 5일(日) 등(等) 초기(初期)에서는 미분해(未分解)의 Imidan과 최초(最初)의 가수분해(加水分解) 산물(産物)인 N-hydroxy methyl phthalimide등(等)이 비교적(比較的) 다량(多量)으로 검출(檢出)되었으나 7일(日), 14일(日) 등(等) 후기(後期)에는 생체내(生體內)에서 더 많은 분해(分解)를 받아 상기(上記) 이성분(二成分)은 양(量)이 감소(減少)되고 phthalic acid, phthalamidic acid benzoic acid 및 p-hydroxy benzoic acid 또는 p-amino benzoic acid등(等)의 양(量)이 증가(增加)되는 것을 볼 수있었으며 도체상(稻體上)에 살포(撒布)된 Imidan 은 체내(體內)에 흡수(吸收)되어 14일(日)이 경과(經過)되면 대부분(大部分)이 분해(分解)를 받는 것으로 보여진다. 이상(以上)의 결과(結果)로 보아 Imidan은 자체(自體)로서는 식물생장(植物生長) 촉진작용(促進作用)이 없으나 식물체내(植物體內)에서 여러 가지 대사작용(代謝作用)(enzyme의 작용(作用))을 맡아서 각종(各種) phthaloyl 영향(影響)을 주는 것으로 생각(生覺)된다.

  • PDF

혁신형 중소기업의 재무적 제약과 배당스무딩간의 관계 (The Relations between Financial Constraints and Dividend Smoothing of Innovative Small and Medium Sized Enterprises)

  • 신민식;김수은
    • 중소기업연구
    • /
    • 제31권4호
    • /
    • pp.67-93
    • /
    • 2009
  • 본 연구는 1999년 1월 1일부터 2007년 12월 31일까지 한국거래소의 유가증권시장과 코스닥시장에 상장된 혁신형 중소기업을 대상으로 재무적 제약과 배당스무딩간의 관계를 실증분석 하였으며, 주요한 분석결과는 다음과 같다. 기업들은 목표 배당성향을 가지고 있으며, 실제 배당성향이 목표 배당성향에서 이탈하면 다시 배당지급을 부분적으로 조정한다. 배당조정속도는 Lintner(1956)의 배당조정모형의 핵심변수인 전기 주당배당과 당기 주당이익을 사용하여 거의 대부분 측정할 수 있으며, 잔여배당이론과 그 이후에 등장한 배당신호이론, 대리인이론, 케이터링 이론 및 거래비용이론에 관한 대용변수들은 배당조정속도에 부분적으로 영향을 미친다. 그리고 전기 주당배당은 당기 주당이익보다 배당조정속도에 더 큰 영향을 미치는데, 이는 기업들이 특별한 이유가 없는 한 전기 주당배당 수준을 장기적으로 유지하는 안정적인 배당정책을 선호한다는 증거가 된다. 혁신형 중소기업은 비혁신형 중소기업보다 배당조정속도가 더 빠르다. 혁신형 중소기업은 R&D 투자에 따른 미래의 성장성과 수익성을 담보로 하여 장기적으로 안정적인 배당정책을 유지할 수 있다. 다시 말해, 혁신형 중소기업은 배당지급이 목표 배당성향에서 이탈하더라도, R&D 투자에 따른 미래의 성장성과 수익성을 담보로 하여 목표 배당성향을 향하여 배당지급을 신속하게 조정하여 배당스무딩을 효과적으로 달성할 수 있다. 그리고 혁신형 중소기업 중에서도 재무적 비제약 기업은 재무적 제약 기업보다 배당조정속도가 더 빠르다. 이는 재무적 비제약 기업일수록 자본시장을 통한 외부 자금조달이 용이하기 때문에 주당배당을 신속하게 조정한다는 증거가 된다. 따라서 자본시장 접근성이 용이하여 재무적 제약을 적게 받는 기업일수록 외부 자금조달이 용이하기 때문에 배당지급을 더 신속하게 조정함으로써 배당스무딩을 더 효과적으로 달성할 수 있다. 그리고 중소기업청이 정책적 목적으로 분류한 혁신형 중소기업(벤처기업, 이노비즈기업, 경영혁신형기업)은 비혁신형 중소기업보다 배당조정속도가 더 빠르다. 중소기업청에서 정책적 목적으로 분류한 혁신형 중소기업은 신용보증지원, 정책자금지원, 조세혜택, 공공입찰 우선권 부여 등과 같은 다양한 정책적 혜택으로 인해 재무적 제약을 적게 받기 때문에 배당지급을 더 신속하게 조정할 수 있다. 결론적으로, 한국거래소의 유가증권시장과 코스닥시장에 상장된 혁신형 중소기업은 비혁신형 중소기업보다 배당조정속도가 더 빠르고, 혁신형 중소기업 중에서도 재무적 비제약 기업은 재무적 제약 기업보다 배당조정 속도가 더 빠르다. 다시 말해, 중소기업 중에서도 R&D 집중도가 높은 혁신형 중소기업은 R&D 투자에 따른 미래의 성장성과 수익성을 담보로 하여 배당스무딩을 신속하게 할 수 있고, 혁신형 중소기업 중에서도 자본시장 접근성이 좋은 기업은 재무적 제약을 적게 받기 때문에 배당스무딩을 더 신속하게 할 수 있다. 따라서 중소기업 경영자는 R&D 집중도를 증가시키고 자본시장 접근성을 높여 재무적 제약을 회피함으로써 신속한 배당스무딩을 통해 장기적으로 안정적인 배당정책을 유지할 수 있다고 생각한다. 그리고 중소기업청이 정책적 목적으로 분류한 혁신형 중소기업(벤처기업, 이노비즈기업, 경영혁신형기업)의 경우에도 배당조정속도가 비혁신형 중소기업보다 더 빠르게 나왔다. 이러한 결과는 배당정책의 측면에서 중소기업청의 혁신형 중소기업 정책을 지지하는 실증적인 증거가 된다.