• Title/Summary/Keyword: Time-gap

Search Result 1,890, Processing Time 0.032 seconds

Design and Test of Vacuum Rotary Arc Gap Switch (Vacuum Rotary Arc Gap Switch의 설계 및 시험)

  • 서길수;황동원;이태호;황리호;김희진;이홍식;임근희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Design and test results of a VRAG(Vacuum Rotary Arc Gap) switch were presented. To control the damage of electrodes caused by the vacuum arc, Lorentz's force by the radial magnetic field between spiral electrodes was used to rotate the vacuum uc. VRAG switch electrodes were made of the material of CuCr and OFHC. Gap distance between two spiral type electrodes for the rotation of the arc discharge is 8, 10, 12mm. In the cathode, one trigger electrode was inserted into each spiral wing. Normal operation of the VRAG switch was confirmed with 10.6[$mutextrm{s}$]of trigger delay and 2~3[$mutextrm{s}$] of the jitter time. The speed of the vacuum arc was measured to be 0.6 ~ 1[km/s] by a motion analyzer.

The effect of plamsa treatment on superconformal copper gap-fill

  • Mun, Hak-Gi;Kim, Seon-Il;Park, Yeong-Rok;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.249-249
    • /
    • 2010
  • The effect of forming a passivation layer was investigated in superconformal Cu gap-filling of the nano-scale trench with atomic-layer deposited (ALD)-Ru glue layer. It was discovered that the nucleation and growth of Cu during metal-organic chemical vapor deposition (MOCVD) were affected by hydrogen plasma treatments. Specifically, as the plasma pretreatment time increased, Cu nucleation was suppressed proportionally. XPS and Thermal Desorption Spectroscopy indicated that hydrogen atoms passivate the Ru surface, which leads to suppression of Cu nucleation owing to prevention of adsorption of Cu precursor molecules. For gap-fill property, sub 60-nm ALD Ru trenches without the plasma pretreatment was blocked by overgrown Cu after the Cu deposition. With the plasma pretreatment, superconformal gap filling of the nano-scale trenches was achieved due to the suppression of Cu nucleation near the entrances of the trenches. Even the plasma pretreatment with bottom bias leads to the superconformal gap-filling.

  • PDF

Good Agriculture Practice (GAP) and Sustainable Resource Utilization of Chinese Materia Medico

  • Wenyuan Gao;Wei Jia;Hongquan Duan;Luqi Huang;Xiaohe Xiao;Peigen Xiao;Peak, Kee-Yoeup
    • Journal of Plant Biotechnology
    • /
    • v.4 no.3
    • /
    • pp.103-107
    • /
    • 2002
  • The Good Agriculture Practice (GAP) program, being established in China, is an optimal way for the sustainable utilization of the medicinal plant and animal resources. Most frequently used Chinese materia medica will be mainly produced from the GAP bases in the future. To assure the successful operation of GAP program, standard operating procedure (SOP) should be implemented for specific plants or animals. Both GAP and SOP include the requirements in many aspects from the ecological environment of cultivation place, germplasm and varieties, seedling and transplant, fertilization, irrigation, and field care, to harvest and process, package, transport and storage. As a complex system, GAP demands strong commitment from the pharmaceutical industry, local administrative involvement, long term R&D support, and years of time of development before a satisfactory result can be achieved.

A Studying on Gap Sensing using Fuzzy Filter and ART2 (퍼지필터와 ART2를 이용한 선박용 용접기술개발)

  • 김관형;이재현;이상배
    • Journal of Korean Port Research
    • /
    • v.14 no.3
    • /
    • pp.321-329
    • /
    • 2000
  • Welding is essential for the manufacture of a range of engineering components which may vary from very large structures such as ships and bridges to very complex structures such as aircraft engines, or miniature components for microelectronic applications. Especially, a domestic situation of the welding automation is still depend on the arc sensing system in comparison to the vision sensing system. Specially, the gap-detecting of workpiece using conventional arc sensor is proposed in this study. As a same principle, a welding current varies with the size of a welding gap. This study introduce to the fuzzy membership filter to cancel a high frequency noise of welding current, and ART2 which has the competitive learning network classifies the signal patterns the filtered welding signal. A welding current possesses a specific pattern according to the existence or the size of a welding gap. These specific patterns result in different classification in comparison with an occasion for no welding gap. The patterns in each case of 1mm, 2mm, 3mm and no welding gap are identified by the artificial neural network.

  • PDF

Advances and current problems in process control - a review

  • Lee, Won-Kyoo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.29-29
    • /
    • 1992
  • Interest in process control has rebounded from an all-time low in the mid-1970s, with a new focus on bridging the gap between academic theory and industrial practice. Since then, much progress has been made in the new generation of process control theory to bridge this gap. This review summarizes the recent advances and cur-rent problems in process control on a qualitative level.

  • PDF

Design and Fabrication of Synchronous Clock Recovery Module for S-DMB GaP Filler (위성 DMB 중계기의 동기용 클럭 재생 모듈 설계 및 제작)

  • Chang, Lae-Kyu;Park, Eun-Hee;Lee, Hang-Soo;Hong, Sung-Yong;Park, Jung-Seo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.107-110
    • /
    • 2005
  • This paper describes the design and fabrication of synchronous clock recovery module for S-DMB Gap Filler. Using the 2.304MHz TTL signal from gap filler tuner, clock recovery module with 10MHz output frequency including holdover function is designed. The measured performance of the clock recovery module shows a stability of less than 0.01ppm, 29 sec stability time, 10 sec holdover time, and maximum -113dBc/Hz@100Hz phase noise.

  • PDF

Performance Comparison Between ER and MR Clutches with Same Gap Size (동일한 간극을 갖고 있는 ER 및 MR 클러치의 성능 비교)

  • Hong, Sung-Ryong;Choi, Seung-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.1055-1064
    • /
    • 1999
  • In this wort ER(electro-rheological) clutch and MR(magneto-rheological) clutch are devised and their performance characteristics such as response time and controllability are compared. As a first step, field-dependent yield stresses of ER and MR fluids are distilled in shear mode. For reasonable comparison between two clutches, a nondimensional design model is established by choosing same design parameters of gap size and number. Following the manufacturing of two clutches, field-dependent torque level, response time to step input, mechanical Power generation to electric power consumption are experimentally measured and compared. In addition, in order to investigate torque controllability of the clutches a sliding mode controller is formulated and experimentally realized. Control bandwidths of two clutches are identified and tracking control responses for desired torque trajectories are presented.

Characteristics of acoustic emission according to variation gap length on artificial needle shape void (인공적 침상보이드의 갭길이 변화에 따른 음향방출 특성)

  • 박재준;김상남
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.495-503
    • /
    • 1995
  • As lengthen gap leng of artificial needle shape void 0.24.rarw.1.5[mm]), the amplitude of AE(Acoustic Emission) pulses was enlarged and number of pulses be generated was few. The longer gap length of void, the shorter breakdown time. As a result of this, I found that existen of void in insulation mate was fatal deterioration of insulation. According to phase angle of applied voltage, time being void was scattered largely in region of phase angle of pulses of origination in phase angle of applied voltage. The result will be used to analysis of void diagnosis.

  • PDF

Evaluation of Driving Properties by Cell-gap Difference of Single Particle-Microcapsule Type Electronic Paper (싱글입자-마이크로캡슐형 전자종이의 셀갭 차이에 따른 구동 특성평가)

  • Song, Jin-Seok;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.518-523
    • /
    • 2015
  • We fabricate a single particle-microcapsule type electronic paper using electrophoresis, which is different with a reported dual particle-microcapsule type and of which electro-optical researches are not reported. So we analyzed a basic properties, such as reflectivity, response time, and driving voltage. Our display panels having various cell-gaps of $30{\mu}m$, $34{\mu}m$, $38{\mu}m$, $42{\mu}m$, and $46{\mu}m$ are inspected. As a results, a driving voltage is defined to 10 V and desirable cell-gap is $30{\mu}m$ or $34{\mu}m$. Considering a mechanical strength, the optimum cell-gap is $34{\mu}m$ for the single particle type electronic paper.

Examination of the Gap between Customer's Perception and Foodservice Provider's Perception of Service Quality in Restaurants (외식엽체에서 제공하는 서비스 품질에 대한 고객과 서비스 제공자의 인식의 차이점 분석)

  • 양일선;김성혜;김동훈
    • Korean Journal of Community Nutrition
    • /
    • v.4 no.3
    • /
    • pp.466-478
    • /
    • 1999
  • A significant gap can exist between what customers expect in foodservice and what service providers deliver to customers. Reducing the gap and enhancing service quality plays a key role in increasing customer satisfaction and repurchase intentions. The purpose of this study was to investigate the personal and operational characteristics that affect the customer perceptions of service quality, to analyze the overall satisfaction and repurchase intention of customers, and to study the service quality gap between customer and foodservice provides. 427 customers and 278 foodservice providers in 82 fast food and family restaurants were surveyed. T-test, ANOVA, Correlation Analysis, and Multiple Regression were used for statistical analysis, The results of this study were as follows: 1) Among the personal characteristics of customers, sex affected the preception of 'General Management' and 'Reputation', and the expense per person showed a correlation with service quality. 2) Among the operational characteristics, the type of restaurant, months since opening, and the number of seats had a significant impact on service quality, while the seat turnover rate showed a negative correlation with service quality. 3) Among the human resource characteristics, the proportion of part-time employees had a negative correlation with service quality, and in general, the training program for full-time employees led to a higher degree of customer perception of service quality. 4) Six dimensions of service quality accounted for 38.39% of customer satisfaction in Multiple Regression. 5) The overall satisfaction of customers willing to repurchase was significantly higher than that of the non-repurchase customers. 6) The operational characteristics explained over 35% for the service quality gap among the customers and the service providers in Multiple Regression.

  • PDF