• Title/Summary/Keyword: Time to frequency conversion

Search Result 164, Processing Time 0.031 seconds

ZVS Phase Shift Full Bridge Converter Design with 2kW Output (2 kW 출력을 갖는 영전압 스위칭 위상 천이 풀 브리지 컨버터 설계)

  • Hwang, Kyu-Il;Kim, Il-Song
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.11
    • /
    • pp.523-530
    • /
    • 2018
  • It has been studied over the long time for the high efficiency and high power density of the power converter. It is possible to obtain higher power conversion efficiency and small volume by increasing switching frequency, however, the switching loss is also increased. The soft switching technique can overcome of the above deficiency. The design and analysis method for ZVS(Zero Voltage Switching) Phase Shifte Full bridge converter is presented in this paper. The power transfer depends on the phase difference between two legs of the power stage and the maximum power conversion efficiency is achieved by the optimum leakage inductance value. The waveform of the current and voltage of the operational mode is analysed and the corresponding switch status is plotted as on/off status. A ZVS full bridge converter for a communication rectifier with 2kW output power is implemented and its performance are verified through PSIM software simulation and experimental results.

Hydroacoustic Records and Numerical Models of the Source Mechanisms from the First Historical Eruption of Anatahan Volcano, Mariana Islands

  • Park M.;Dziak R.P.;Matsumoto H.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.232-237
    • /
    • 2004
  • Anatahan Volcano in the Commonwealth of the Northern Mariana Islands (CNMI) erupted for the first time in recorded history on 10 May 2003. The underwater acoustic records of earthquakes, explosions, and tremor produced during the eruption were recorded on a sound-channel hydrophone deployed in February 2003. Acoustic propagation models show the seismic to acoustic conversion at Anatahan is particularly efficient, aided by the slope of the seamount toward the hydrophone. The hydrophone records confirm the onset of earthquake activity at 01:53Z on 10 May, as well as the onset (at ${\~}$06:20Z) of continuous, low-frequency (5-40 Hz) acoustic energy that is likely volcanic tremor related to magma intrusion. The hydrophone recorded a total of 458 earthquakes associated with the eruption. To predict the character of acoustic signals generated from Anatahan, we developed a moment-tensor representation of a volcano-seismic source that is governed by the geometry of the source and the physical properties of the magma. A buried magmatic pipe model was adopted, and numerically modeling source parameters such as the pipe radius and magma viscosity enable us to grasp the inward nature of Anatahan Volcano.

  • PDF

Application and Verification of Fully-Integrated Design Environment for Piezoelectric Energy Harvester (압전형 에너지 수확장치를 위한 통합 해석환경의 적용 및 검증)

  • Liu, Jian;Welham, Chris;Han, Seungoh
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.364-368
    • /
    • 2013
  • Vibrational energy harvester based on piezoelectricity has been expected to be the dominant energy harvesting technology due to the advantages of high conversion efficiency, light weight and small size, night operation, etc. Its commercialization is just around the corner but the integration with power management electronics should be solved in advance. In this paper, therefore, fully-integrated design environment for piezoelectric energy harvesting systems is presented to assist co-design with the power management electronics. The proposed design environment is capable of analyzing the energy harvester including the package-induced damping effects and simulating the device and its power management electronics simultaneously. When the developed design environment was applied to the fabricated device, the simulated resonant frequency matched well with the experimental result with a difference of 2.97% only. Also, the complex transient response was completed in short simulation time of 3,001 seconds including the displacement distribution over the device geometry. Furthermore, a full-bridge power management circuit was modeled and simulated with the energy harvester simultaneously. Therefore the proposed, fully-integrated design environment is accurate and fast enough for the contribution on successful commercialization of piezoelectric energy harvester.

Charge-coupled analog-to-Digital Converter (전하결합소자를 이용한 Analog-to-Digital 변화기)

  • 경종민;김충기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.5
    • /
    • pp.1-9
    • /
    • 1981
  • Experimental results on a 4-bit charge-coupled A/D converter are described. Major operations in the successive approximation algorithm are implemented in a monolithic chip, CCADC, which was fabricated usir p-channel CCD technology, with its die size of 4,200 mil2 Typical operating frequency range has been found out to be from 500Hz to 200kHz. In that frequency range, no missing code has been found in the whole signal range of 2.4 volts for ramp signal slewing at 1 LSB/(sampling time). A discussion is made on several layout techniques to conserve the nominal binary ratio of (8:4:2:1) among the areas of four adjacent potential wells (M wells), whose charge storing capacities correspond to each bit magnitude - 3.6 pC, 1.8 pC, 0.9 pC, and 0.45 pC nominal in the order of MSB to the LSB. The effect of 'dump slot', which is responsible for the excessive nonlinearity (2$\frac{1}{2}$LSB) in the A/D converter, is explained. A novel input scheme called 'slot zero insertion' to circumvent the deleterious effects of the dump slot is described with the experimental results.

  • PDF

A Study on a Dynamic Radar Cross Section Analysis Technique for a Surface Warship (수상함의 동적 레이더 반사면적 해석 기법 연구)

  • Kim, Kook-Hyun;Kim, Jin-Hyeong;Choi, Tae-Muk;Kim, Yun-Hwan;Cho, Dae-Seung
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.77-81
    • /
    • 2009
  • The radar cross section (RCS) of a warship is one of the most important design features in terms of her survivability in hostile environments. Ocean waves continuously changes the attitude of an objective warship to hostile radar and distorts the RCS as a result. This paper presents a dynamic RCS analysis technique and procedure that considers temporal ship motion. First, data sets are prepared for ship motions in 6 degrees of freedom, which are numerically simulated for an objective warship via frequency to time domain conversion with response amplitude operators and specified ocean wave spectra. Second, a series of RCS analysis models are transformed geometrically by referring to ship motion data sets. Finally, temporal RCS analyses are carried out with the RCS simulation code, SYSCOS. As an example, RCS analysis results are given for a virtual warship, which show that ship motions temporally change RCS values and cause RCS reduction compared with static value in terms of mean values.

Diagnosis of Fault and Abnormal Conditions in a Single-Phase Transformer Using S-parameter Measurement (S파라미터를 이용한 단상 변압기의 이상 상태 진단에 대한 연구)

  • Kim, Jeongeun;Kim, Kwangho;Nah, Wansoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1344-1352
    • /
    • 2018
  • In this paper, we propose a two-port S-parameter data to diagnose the fault conditions of a single-phase transformer. Using the S-parameters we can measure the reflection and transmission characteristics of signal power at the port of a transformer, which can also be converted into ABCD parameters and Z parameters through a well-known conversion formulas. Transformer fault diagnoses can be performed based on the intuitive and qualitative/quantitative characteristics of the these parameters. In addition, we can obtain wide frequency characteristics at the primary and secondary sides of the transformer, which can be used to get time domain responses using the inverse Fourier transformation with some specific input waveform. In order to verify the effectiveness of the proposed method, the fault conditions were analyzed in simulation and experiment for 3 kVA single phase transformer with 15: 5 turns ratio, and the validity of the proposed method was verified.

Laparoscopic Appendectomy in Nonperforated Appendicitis of Children (소아 비천공 충수염에 대한 복강경 충수절제술)

  • Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.9 no.1
    • /
    • pp.41-44
    • /
    • 2003
  • Appendicitis is the most common surgical emergency in childhood. Open appendectomy has been the standard treatment. The minimally invasive techniques have been adopted in children after experiences in various surgical conditions in adults has accumulated. It is debatable whether laparoscopic appendectomy (LA) is superior to open appendectomy (OA) in children. The goal of this study is to review the results of laparoscopy and laparotomy in the nonperforated appendicitis. The records of 22 patients under 15 years of age who were operated upon for nonperforated appendicitis at Asan Medical Center were analyzed between December 2002 and April 2003. Age, type and length of intervention, frequency of analgesic use, complication, length of hospitalization, and cost for each treatment groups (N=11) were compared. Laparoscopy patients were older (13.0 vs. 10.1 years; p > 0.05), and operative time was longer (55.0 vs. 35.0 minutes; p < 0.05). There was no conversion (OA to LA). The median length of hospital stay was significantly shorter in laparoscopy (3.0 vs. 2.0 days; p < 0.05). The median cost for LA was more expensive (W833, 836 vs. W751,398; p < 0.05). Even though there were higher costs and longer operative times with laparoscopic procedures, the shorter hospital stay was an advantage.

  • PDF

Design of a non-contacting single infrared sensor for high frequency dental casting machine (치과용 고주파 주조기를 위한 비접촉 단일 온도센서 설계)

  • Hwang, In;Won, Yonggwan;Lee, Sang-Hun;Song, Sung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1546-1552
    • /
    • 2016
  • In addition, because it uses preheating to dissolve an alloy in general, it is hard to regulate the appropriate melting temperature of the alloy and brewing time and shows the defect of the supplementation thing due to the super-heating. Once the alloy is molten and then most of the casting by attaching a sight glass or non-contact temperature sensor is suitable casting temperature the operator pressing a button to generate a centrifugal force to inject the molten alloy into a crucible in the casting ring. These results, and most of the cast temperature is too high or too low to generate a lot of casting defects do not get into a uniform cast body. In this paper, we developed a dental casting machine for high frequency using a single temperature sensor which can measure the actual temperature of the alloy than the temperature of the external non-contact measurement using a temperature sensor.

contactless power conversion system using the Boost converter (승압형 컨버터를 활용한 비접촉식 전력변환 시스템)

  • Lee S. J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.214-217
    • /
    • 2003
  • The connectorless power supply system on that multi-contact causes confidence when the wiring reconstructed in the rear. As you see above, contact points between sets and indoor space cause inferior function of audio frequency so it needs to be eliminated. This paper explains the structure of connectorless power supply to supply the system with power crossing the air gap in the part of inductively in the connectorless power supply of both magnetic and electrical model. To get maximum output of electrical load, compensating capacitor compensates to show inter-inductance, lequeage-inductance reducing the track-inductance and access the conditions for resonance. At that time it accesses the maximum electric power. The small change of the value of compensating capacitor causes the changes of maximum electric power. Here the power electronics technology is used not only in the industrial machinery but also in the home appliances so the switching power supply is used to actualize the miniaturization, lightweight, and high efficiency. Generally the condenser input methods are widely used in the rectification circuit of switching power supply, but condenser input method generate great quantity of high frequency components because with this method the current flows in the power input filtering condenser only around value of peak of ac input voltage. To solve these problems, installation of power factor improve circuit on the front of filtering capacitence was considered. Several methods were suggested regarding, but the active filter method which makes smalliging and highly power factor possible are the produce main stream. IC for power factor improvement can be utilized by CMOS process proposing low power consumption. When the high power factor is considered seriously in the power factor improvement circuit, active filter method is selected. In the active filter method, the boost converter is used. Regarding this ·the boost converter is needed.

  • PDF

Evaluation on Reaction Kinetics of Cow Manure in Carbonization Process (탄화공정에서의 우분 반응속도 평가)

  • Kim, Jae-Kyung;Lee, Min-Seok;Rhee, Seung-Whee
    • Resources Recycling
    • /
    • v.23 no.6
    • /
    • pp.40-46
    • /
    • 2014
  • Through the study of the basic characteristics of cow manure and the characteristics of carbonization residue, carbonization degree, conversion rate, kinetic reactions, and activation energy for cow manure were examined. Since the heating value of cow manure was very low, it was converted to carbonization residue as a fuel with heating value of 4,300 kcal/kg by carbonization processes. Conversion rate was increased rapidly up to 10 minutes of the initial reaction stage and was increased with increasing temperature. The carbonization of cow manure could be described by the 1st order reaction. Frequency factor(A) of reaction rate for cow manure was evaluated to be $1.34{\times}10^{-2}min^{-1}$, the activation energy was estimated to be 5,196.4 cal/mol. As carbonization temperature increased from $250^{\circ}C$ to $400^{\circ}C$, the kinetic reaction was increased from $0.2107min^{-1}$ to $0.0679min^{-1}$. From the result of the carbonization for cow manure, it can be determined that the optimal conditions of the carbonization process were 20 minutes in carbonization time and $350^{\circ}C$ for carbonization temperature.