• 제목/요약/키워드: Time of storage

검색결과 5,140건 처리시간 0.032초

A STUDY FOR DOSE DISTRIBUTION IN SPENT FUEL STORAGE POOL INDUCED BY NEUTRON AND GAMMA-RAY EMITTED IN SPENT FUELS

  • Sohn, Hee-Dong;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.174-182
    • /
    • 2011
  • With the reactor operation conditions - 4.3 wt% $^{235}U$ initial enrichment, burn-up 55,000 MWd/MTU, average power 34 MW/MTU for three periods burned time for 539.2 days per period and cooling time for 100 hours after shut down, to set up the condition to determine the minimum height (depth) of spent fuel storage pool to shut off the radiation out of the spent fuel storage pool and to store spent fuels safely, the dose rate on the specific position directed to the surface of spent fuel storage pool induced by the neutron and gamma-ray from spent fuels are evaluated. The length of spent fuel is 381 cm, and as the result of evaluation on each position from the top of spent fuel to the surface of spent fuel storage pool, it is difficult for neutrons from spent fuels to pass through the water layer of maximum 219 cm (600 cm from the floor of spent fuel storage pool) and 419 cm (800 cm from the floor of spent fuel storage pool) for gamma-ray. Therefore, neutron and gamma-ray from spent fuels can pass through below 419 cm (800 cm from the floor) water layer directed to the surface of spent fuel storage pool.

수확시기에 따른 조생온주 밀감의 품질과 수상저장 효과 (Effect of Stroage on the Tree and Quality of Early Variety of Citrus unshiu Produced in Cheju According to Harvest Time)

  • 고정삼;양영택
    • 한국식품저장유통학회지
    • /
    • 제4권2호
    • /
    • pp.131-137
    • /
    • 1997
  • Effect of storage on the tree and quality of early cultivar of Citrus unshiu Marc. produced in Cheju according to harvest time were investigated. Soluble solids, acid content, flesh ratio, firmness and specific cavity of the fruits harvested at 27th of November were 12.0, 1.03%, 79.98%, 0.774kg-force, 0.912, respectively. Soluble solids, total sugar and reducing sugar were increased gradually, but acid content was decreased slightly as delayed in harvest time. Otherwise specific gravity and firmness were not shown in great during harvest time, color index(a/b) was increased sharply till late November and then remained in stationary phase. On these result, we recommend that the harvest time of early cultivar of Citrus unshiu Marc. would be during December because of wilting partly. Fully ripened-fruits harvested late, compared to ordinary harvest time, with cold storage would be kept more quality and freshness of fruits for fresh consumption than the fruits harvested early and stored at room temperature.

  • PDF

축열식 심야전력기기를 위한 축열량 제어기 설계 (Design of a Controller for the Heat Capacity of Thermal Storage Systems Using Off-Peak Electricity)

  • 이은욱;양해원
    • 제어로봇시스템학회논문지
    • /
    • 제7권1호
    • /
    • pp.1211-1217
    • /
    • 2001
  • This paper presnts a controller for the heat capacity of thermal storage systems using off-peak electricity which is composed of an identifier using neural networks and a storage time adjuster in order to store exactly the required thermal energy without loss. Since thermal storage systems have nonlinear characteristics and large time constant, even if we predict the heating load accurately, it is very difficult to store exactly the required thermal energy. Thus, in the neural network for the identifier, the adaptive learning rate for high learning speed and bit inputs based on state changes of thermal storage power source are used. Also a hardware for the controller using a microprocessor is developed. The performance of the proposed controller is shown by experiment.

  • PDF

유지놀 처리된 상아질 표면의 상아질 접착제의 전단결합강도에 관한 연구 (SHEAR BOND STRENGTH OF DENTIN BONDING AGENTS ON DENTIN SURFACE TREATED WITH EUGENOL)

  • 유화성;최기운;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.550-560
    • /
    • 2000
  • In this study, shear bond strength of two bonding systems were measured and appearance of dentin surfaces were observed with SEM according to the storage time of eugenol on dentin surface, thus evaluated the effect of eugenol on bond strength of two dentin bonding systems. Control groups were directly bonded to dentin surface with One Step, Prime & Bond 2.1. Experimental groups were divided into experimental I and II according to dentin bonding agents. After eugenol application, dentin surfaces were bonded with One Step and Prime & Bond 2.1 according to the each storage time of immediately, 3min, 24hour, 48hour and 1week, and then control and experimental groups were filled with light cured composite resin(Z-100). After 24 hours water storage at $37^{\circ}C$, all samples were subjected to a shear load to fracture at a cross head 1.0mm/min with Instron universal testing machine(No. 4467). Etched dentin surface storaged for each time of immediately, 3min, 24hour, 48hour and 1 week after eugenol application were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically with two-way ANOVA and Tukey's HSD. The results were as follows; 1. Shear bond strengths were higher in control groups than in the experimental groups. 2. As storage time was increased after eugenol application, the shear bond strengths were decreased in experimental groups. 3. In experimental I, II the shear bond strengths were the lowest in which storage time was 1 week after eugenol application. 4. As storage time was increased after eugenol application, etched dentin surfaces showed obstructed dentinal tubule.

  • PDF

Volatile Discrimination of Irradiated and Fumigated White Ginseng Powders at Different Storage Times and Temperatures Using the Electronic Nose

  • Shin, Jung-Ah;Kwon, Joong-Ho;Lee, Ki-Teak
    • Preventive Nutrition and Food Science
    • /
    • 제11권3호
    • /
    • pp.237-242
    • /
    • 2006
  • The pattern of volatile emissions from white ginseng powders (WGP) that were treated with selected preservatives was investigated during 5-months of storage (at -10 and $25^{\circ}C$) by an electronic nose system equipped with 12 metal-oxide sensors. WGP were treated with gamma radiation at 5 kGy, commercial methyl bromide (MeBr), and phosphine fumigations. Electronic nose differentiated the volatile patterns of the WGP with each different preservative treatment. In addition, each volatile pattern was affected by both storage time (1, 2 and 5 months) and temperature (-10 and $25^{\circ}C$). After 5-months of storage, the least change of volatile patterns was observed from WGP fumigated with phosphine at $-10^{\circ}C$. The result also showed that volatile changes in WGP were much more affected by storage time than by storage temperature.

연속미디어 저장 서버에서의 실시간 저장 및 검색 기법 (Real-Time Storage and Retrieval Techniques for Continuous Media Storage Server)

  • CheolSu Lim
    • 전자공학회논문지B
    • /
    • 제32B권11호
    • /
    • pp.1365-1373
    • /
    • 1995
  • In this paper, we address the issues related to storage and retrieval of continuous media (CM)data we face in designing multimedia on-demand (MOD) storage servers. To support the two orthogonal factors of MOD server design, i.e., storage and retrieval of CM data, this paper discusses the techniques of disk layout, disk striping and real-time disk scheduling, which are integrated as a combined solution to the high- performance MOD storage subsystem. The proposed clustered striping technique enables either a multiple-disk or a parallel system to guarantee a continuous retrieval of CM data at the bandwidth required to support user playback rate by avoiding the formation of I/O bottlenecks.

  • PDF

자연순환식 태양열 급탕 시스템의 성능 추정 방법에 관한 연구 (A Study on the System Performance Prediction Method of Natural Circulation Solar Hot Water System)

  • 윤석범;전문헌
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.37-53
    • /
    • 1987
  • This study has been prepared for the purpose of developing the system performance prediction method of natural circulation solar hot water system. The storage tank of the natural circulation solar hot water system equipped with flat-plate solar collector is located at higher elevation than the solar collectors. Therefor, the storage tank temperature distribution formed accordance with configuration of storage tank by flow rate of circulating fluid affect system collection efficiency. In this study measure the storage tank temperature distribution with various experimental system under real sun condition and present the theoretical prediction method of the storage tank temperature. Moreover measure the flow rate not only day-time but also night-time reverse flow rate with die injection visual flow meter. Main conclusion obtain from the present study is as follows; 1) The storage tank temperature distribution above the connecting pipe connection position is the same as that of the fully mixed tank and below the connection position is the same as that of stratified tank. 2) The system performance sensitive to the storage tank temperature distribution. Therefore detailed tank model is necessary. Average storage tank temperature can be calculate 3% and storage tank temperature profile can get less than 10% difference with this model system.

  • PDF

캡슐형 빙축열시스템에 대한 운전 시뮬레이션 및 에너지비용 분석 (Simulation and Energy Cost Calculation of Encapsulated Ice Storage System)

  • 이경호;주용진;최병윤;김상준
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.63-73
    • /
    • 1999
  • Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.

  • PDF

The Implementation of Storage Type Power Flow Controller using Battery Storage

  • Leung, K.K.;Sutanto, D.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.99-106
    • /
    • 2001
  • This paper describes the implementation of a Storage Power Flow Controller (SPFC) connected to the grid which can provide concomitant benefits associated with a Unified Power Flow Controller while at the same time providing several other very important benefits to power system operation such as, load leveling dynamic voltage stability inprovement, harmonic compensation and power factor correction. This Storage power Flow Controller (SPFC) was implemented using real time signal processors, three-phase inverter(s) and battery bank which can provide improved power system operation and control, added system security and reduced power system losses.

  • PDF

Design and simulation of high performance computer architecture using holographic data storage system for database and multimedia workloads

  • Na, Jong-Whoa;Ryu, Dae-Hyun;Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • 제1권4호
    • /
    • pp.169-173
    • /
    • 2003
  • The performance of modern mainframe computers keeps increasing due to the advances in the semiconductor technology. However, the quest for the faster computer has never been satisfied. To overcome the discrepancy in the supply and demand, we studied a high performance computer architecture utilizing a three-dimensional Holographic Data Storage Systems (HDSS) as a secondary storage system. The HDSS can achieve a high storage density by utilizing the third dimension. Furthermore, the HDSS can exploit the parallelism by processing the two-dimensional data in a single step. To compare the performance of the HDSS with the conventional hard disk based storage system, we modeled the HDSS using the DiskSim simulation engine and performed the simulation study. Results showed that the HDSS can improve the access time by 1.7 times.