• Title/Summary/Keyword: Time intervals

Search Result 2,120, Processing Time 0.036 seconds

Effect of Different Preservation Methods on Physicochemical Quality of Beef

  • Akter, H.;Akhter, S.;Rahman, S.M.E.;Rahman, M.M.;Hossain, M.M.;Ra, C.S.;Kim, Jai-Moung;Oh, Deog-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2009
  • The study was conducted to evaluate the effect of drying, curing and freezing on the quality of beef. Three types of dried (without salt = $T_1$, with salt = $T_2$ and salt + spices = $T_3$); three types of cured (salt curing = $T_4$, sugar curing = $T_5$ and brine curing = $T_6$) and three types of frozen beef ($0^{\circ}C=T_7^{\circ}C$, $-10^{\circ}C=T_8$ and $-20^{\circ}C=T_9$) were analyzed at different time intervals up to the period of 180 d. Parameters studied were protein, fat, ash, color and cooking loss of beef. All the chemical constituents (protein, fat and ash) were decreased gradually up to 120 d. The decreasing trend was observed rapid after 120 d up to 180 d of preservation. Highest protein loss was found in $T_7$ (11.1 %) and the lowest protein loss was found in $T_6$ (3.85%) in 180 d preservation and significant (p < 0.01) differences were observed among the different preservation methods. Highest fat loss was observed in $T_6$ (7.62%) and the lowest fat loss was observed in $T_2$ (3.18%) and the differences were also significant (p < 0.05) among different methods during the experimental period. Spices dried beef showed a brighter color than others and cured beef showed brown color and the intensity of color was reduced gradually with the increasing of storage period. $T_9$ showed the lowest cooking loss among 3 treatments of frozen beef and the differences also significant (p < 0.01) up to 180 d. It might be stated that sugar curing ($T_5$) and spices drying ($T_3$) would be the useful technique of meat preservation in rural areas and freezing ($T_9$) would be used in large scale preservation at urban areas.

A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION (Sealed amalgam restoration의 미세누출에 관한 연구)

  • Lee, Sang-Heon;Lee, Jae-Cheoun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.54-61
    • /
    • 2000
  • Amalgam, though a widely used dental material, does not bond to the tooth substrate Therefore, retentive preparation of the cavity is necessary. Such amalgam restorations, until corrosion products form and plug the margin, will show significant marginal leakage. Unless this is prevented early on, saliva and bacteria may enter the cavity causing postoperative hypersensitivity, dissolution and collapse of the restoration, discoloration of the margin and secondary caries, leading to shortened life-span of the restoration and pulpal pathosis. Recently, a method of restoration has been introduced whereby tooth material can be preserved, cavity margin can be sealed and preventive treatment of pit and fissure can be administered while retaining all the advantages of conventional amalgam restorations. Such sealed amalgams involve removing the carious lesion without extending the cavity for prevention and using pit and fissure sealants to seal cavity margins and pit and fissures to reduce microleakage. In this study, finishing of the amalgam and sealant application were performed after different intervals following of amalgam restoration to compare the microleakage of sealed and conventional amalgam restorations. Thirty bicuspids were prepared with Class V cavity preparations on the buccal and lingual surfaces. After amalgam placement, they were divided into the following groups and treated accordingly. Group 1 : Polishing after 24 hours Group 2 : Immediate sealant application without polishing Group 3 : No polishing, but sealant applied after thermocycling 500 times After treatment, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue kept in a $37^{\circ}C$ incubator at 100% humidity for 24 hours. The teeth were then embedded in resin and cut bucco-lingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage, The following results were obtained : 1. Group 2 showed the least microleakeage, while group 1 showed the greatest. 2. Group 1 showed significantly greater microleakage compared to group 2 (p<0.05). However, no significant differences were found between group 1 and 3(p>0.05). No significant differences in microleakage were also found between cup 2 and 3(p<0.05).

  • PDF

Reliability of Quantitative Sensory Testing Using Current Perception Thresholds in the Mandibular Nerve Area (하악신경영역에서 전류인지역치를 이용한 정량적 감각신경 검사의 재현성 조사)

  • Choi, Hee-Hun;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.2
    • /
    • pp.131-137
    • /
    • 2011
  • Current Perception Threshold (CPT) using Neurometer($Neurometer^{(R)}$ CPT/C) is thought as one of easy and noninvasive QST(qunatitative sensory testing) tools for A${\beta}$, A${\delta}$ and C fibers within a relatively short time. However, conflicts about its reliability still exist. This study aimed to evaluate the reliability of CPTs evaluation and find a way to increase its reliability. Two examiners separately tested CPTs at each side of the mandibluar nerve areas for ten healthy male adults (average age of 22.4 years) three times with an intervals of a week during three weeks. Mean CPTs were compared between the right and left sides of the mandibular nerve area and between the three examinations on the each side. While CPTs at 2000 Hz(A${\beta}$ fiber) showed statistically significant side differences in all three examinations (p<0.05), significant side difference was found in only one examination at 250 Hz(A${\delta}$ fiber) and no difference at 5 Hz(C fiber). Comparing CPTs on the each side of the mandibular nerve area, all examinations at all sensory nerve fibers showed the least CPTs at the 1st examinations. CPTs at 250 Hz(A${\delta}$ fiber) and 5 Hz(C fiber) were significantly different between the first and the following examinations (p<0.05) and there was no significant difference between 2nd and 3rd examinations. The results of this study indicated that CPTs at 250 Hz(A${\delta}$ fiber) and 5 Hz(C fiber) are reliable but CPTs at 2000 Hz(A${\beta}$ fiber) is not appropriate for evaluation of side differences in the mandibular nerve area. In addition, it is suggested that repeated examination be helpful to increase reliability of the CPT evaluation.

Low price type inspection and monitoring system of lithium ion batteries for hybrid vessels (하이브리드 선박용 리튬 배터리의 저가형 감시시스템 구현)

  • Kwon, Hyuk-joo;Kim, Min-kwon;Lee, Sung-geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • Batteries are used for main power engine in the fields such as mobiles, electric vehicles and unmanned submarines, for starter and lamp driver in general automotive, for emergency electric source in ship. These days, lead-acid and the lithium ion batteries are increasingly used in the fields of the secondary battery, and the lead-acid battery has a low price and safety comparatively, The lithium ion battery has a high energy density, excellent output characteristics and long life, whereas it has the risk of explosion by reacting with moisture in the air. But Recently, due to the development of waterproof, fireproof, dustproof technology, lithium batteries are widely used, particularly, because their usages are getting wider enough to be used as a power source for hybrid ship and electric propulsion ship, it is necessary to manage more strictly. Hybrid ship has power supply units connected to the packets to produce more than 500kWh large power source, and therefore, A number of the communication modules and wires need to implement the wire inspection and monitor system(WIIMS) that allows monitoring server to transmit detecting voltage, current and temperature data, which is required for the management of the batteries. This paper implements a low price type wireless inspection and monitoring system(WILIMS) of the lithium ion battery for hybrid vessels using BLE wireless communication modules and power line modem( PLM), which have the advantages of low price, no electric lines compared to serial communication inspection systems(SCIS). There are state of charge(SOC), state of health(SOH) in inspection parts of batteries, and proposed system will be able to prevent safety accidents because it allows us to predict life time and make a preventive maintenance by checking them at regular intervals.

Sequential Pituitary Hormone Responses to Electroconvulsive Therapy (전기경련요법후 뇌하수체 호르몬의 순차적인 분비 반응)

  • Kim, Doh Kwan;Kim, Soo Jeong;Choi, Do Sun;Bok, Hae-Sook;Kim, Seungtai Peter
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.288-294
    • /
    • 1996
  • Background : Most studies of the pituitary hormonal responses to electroconvulsive therapy(ECT) have used limited blood sampling schedules. Little is known about the precise sequence of neuroendocrine events immediately following en ECT application. or about the regulation of the hormonal responses. Methods : Blood was sampled at three minute intervals from eleven patients(two schizophrenics and nine affective disorder patients) undergoing ECT. Each sample was immunologically assayed for arginine vasopressin(AVP), adrenocorticotropic hormone(ACTH), prolactin(PRL), and cortisol. Baseline hormone concentrations and several measures of response were determined for each hormone. The temporal and quantitative relationships among the hormonal responses were determined. Correlations were calculated between seizure duration and secretory responses. Results : All four hormones demonstrated significant secretory responses to ECT, with AVP increasing from 1.2 to 33.3pg/ml(P<0.001), ACTH from 5.4 to 32.3fmol/ml(P<0001). PRL from 21.8 to 102.2ng/ml(P<0.005) and cortisol from 20.1 to 31.1ug/dl(P<0.001). The three pituitary hormones showed consistent time courses of secretion with onset of responses by three minutes but clearly differing peak times of 3, 6, and 12-15 minutes for AVP, ACTH, and PRL, respectively. Cortisol began to rise after 6minutes and pecked between 20-30minutes. There ware no significant correlations between seizure duration and any of the secretory response measures. Conclusions : 1) The pituitary hormone response to ECT is sequential rather than synchronous 2) The AVP response was extremely rapid and more massive than those of any other hormones. 3) The ACTH response of this study was more rapid and mare robust than thai revealed by the mast of past studies. 4) The results strongly suggest that the pituitary hormones are released as a result of the seizure rather tho, the electrical stimulus. 5) The sequential pattern of responses suggests that neuroendocine feedback-regulatory mechanisms determine the response profile.

  • PDF

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

Concurrent Chemoradiotherapy in Elderly Patients with Locally Advanced Esophageal Carcinoma (고령의 국소 진행된 식도암환자에서 동시 항암화학방사선치료)

  • Jung, Bae-Kwon;Kang, Ki-Mun;Lee, Gyeong-Won;Kang, Jung-Hoon;Kim, Hoon-Gu;Lee, Won-Seob;Chai, Gyu-Young
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.84-90
    • /
    • 2009
  • Purpose: The effect of concurrent chemoradiotherapy was analyzed in elderly patients when used in the treatment of locally advanced esophageal cancer. Materials and Methods: The retrospective analysis included 28 elderly patients aged 65 or older, with histopathologically confirmed squamous cell carcinoma of the esophagus, underwent concurrent chemoradiotherapy from January 2001 to July 2007. The squamous cell carcinoma disease stages included 8 patients (28.8%) in stage IIa, 10 patients (35.7%) in stage IIb, and 10 patients (35.7%) in stage III. Fractionated radiotherapy was performed with a 6 MV or 10 MV X-ray for 45~63 Gy (median: 59.4 Gy). Chemotherapy was applied concurrently with the initiation of radiotherapy. A 75 mg/$m^2$ dose of Cisplatin was intravenously administered on day 1. Further, 5-FU 1,000 mg/$m^2$ was continuously administered intravenously from days 1 to 4. This regimen was performed twice at 3-week intervals during radiotherapy. Two cycles of consolidation chemotherapy was performed after radiotherapy. Results: The follow-up period was 3~72 months (median: 19 months). The treatment responses after concurrent chemoradiotherapy included a complete response in 11 patients (39.3%), a partial response in 14 patients (50.0%), and no response in 3 patients (10.7%). The overall response rate was 89.3% (25 patients). The overall 1-, 2- and 3-year survival rates were 55.9%, 34.6% and 24.2%, respectively. The median survival time was 15 months. Two-year survival rates of patients with a complete response, partial response, and no response were 46.2%, 33.0%, and 0%, respectively. The stage and tumor response after concurrent chemoradiotherapy were statistically significant prognostic factors related with survival. No treatment-related deaths occurred in this study. Conclusion: Concurrent chemoradiotherapy is a relatively effective treatment without serious complications in elderly patients with locally-advanced esophageal cancer.

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

Cytogenetic Radiation Adaptive Response Assessed by Metaphase Analysis and Micronuclei Test in Human Lymphocytes and Mouse Bone Marrow Cells (인체말초혈액 림프구와 마우스골수세포에서 중기염색체 분석법과 미소핵검사법을 이용한 방사선적응반응 평가)

  • Min, Jung-Jun;Bom, Hee-Seung;Lee, Seung-Yeon;Choi, Keun-Hee;Jeong, Hwan-Jeong;Song, Ho-Cheon;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.525-533
    • /
    • 1998
  • Purpose: Radiation adaptive response in human peripheral lymphocytes and mouse bone marrow cells was investigated using both metaphase analysis and micronucleus assay. We assessed the correlation between both tests. Materials and Methods: Two groups of the human peripheral lymphocytes and mouse bone marrow cells were exposed to low dose (conditioning dose, 0,18 Gy) or high dose (challenging dose, 2 Gy) ${\gamma}$-rays. The other 4 groups were exposed to low dose followed by high dose after several time intervals (4, 7, 12, and 24 hours, respectively). The frequencies of chromosomal aberrations in metaphase analysis and micronuclei in micronucleus assay were counted. Results: Chromosomal aberrations and micronuclei of preexposed group were lower than those of the group only exposed to high dose radiation. Maximal reduction in frequencies of chromosomal aberrations were observed in the group to which challenging dose was given at 7 hour after a conditioning dose (p<0.001). Metaphase analysis and micronucleus assay revealed very good correlation in both human lymphocytes and mouse bone marrow cells (r=0.98, p<0.001 ; r=0.99, p=0.001, respectively). Conclusion: Radiation adaptive response could be induced by low dose irradiation in both human lymphocytes and mouse bone marrow cells. There was a significant correlation between metaphase analysis and micronucleus assay.

  • PDF

Sinus Node Function after Extended Transseptal Approach for Mitral Valve Surgery: 164 Clinical Cases (경중격 절개방식을 좌심방 상부까지 연장시킨 방법을 통한 승모판막 수술 후 동방 결절 기능부전에 대한 164예 임상분석)

  • Ryu Se Min;Kim Hyun Koo;Cho Yang Hyun;Sim Jae Hoon;Sohn Young-sang;Choi Young Ho;Kim Hark Jei
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.214-220
    • /
    • 2005
  • Extended transseptal approach can provide an excellent view of the mitral valve but the safety of this approach is controversial because this incision requires transaction of the sinus node artery, which in most cases and can result postoperative arrhythmia. The purpose of this study was to evaluate perioperative and longterm conduction disturbances and the cardiac rhythms of patients who underwent an extended transseptal approach for mitral valve surgery. Material and Method: Postoperative cardiac rhythms were analyzed in the 164 consecutive patients who received mitral valve replacements with a extended transseptal approach between March 1992 and July 2003. Result: Of the 84 patients in normal sinus rhythm, 34 ($39\%$) had developed transient junctional rhythm and atrial fibrillation after operation, lasting less than 72 hours in most of cases. No intractable arrhythmias occurred. Most of these arrhythmia were not detected at the time of discharge and only 8 patients ($9\%$) had atrial fibrillation at discharge. Postoperative PR intervals increased for 1 week, then decreased within 2 weeks postoperatively, and returned to normal range by 6 months postoperatively. During the postoperative period, 4 of the 78 patients with preoperative atrial fibrillation developed normal sinus thythm. Conclusion: The post-operative arrhythmias were temporary and showed no significant complications after extended transseptal approach for the mitral valve surgery.