• Title/Summary/Keyword: Time based sampling

Search Result 958, Processing Time 0.034 seconds

Adaptive Control of Multiplexed Closed Circuit Anesthesia

  • Jee, Gyu-In;Roy, Rob
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.79-81
    • /
    • 1992
  • This paper describes the design of an adaptive closed circuit anesthesia controller based on a multiplexed mass spectrometer system. The controller deals with measurement deterioration caused by measurement delay and rise time through a tong catheter as well as long sampling times due to the multiplexed measurements. Measurement data is extrapolated between sampling periods to increase the estimation convergence rate. A multiple-step-ahead predictive control algorithm is used to calculate intermediatc control inputs between sampling intervals. Simulations are used to validate the designed controller.

  • PDF

Design of a Life Test Sampling Plan Based on the Cost Model

  • Kwon, Young-Il
    • International Journal of Reliability and Applications
    • /
    • v.6 no.1
    • /
    • pp.31-39
    • /
    • 2005
  • An economic life test sampling plan for products with exponential lifetime distribution is developed. To reduce test time, a test plan with curtailed Type II censoring is considered. A cost model is constructed which involves three cost components; test cost, accept cost, and reject cost. Determination of optimal plan minimizing the expected average cost per lot is discussed with a constraint related to consumer's risk. Some numerical examples are provided.

  • PDF

A CMOS IR-UWB RFIC for Location Based Systems (위치 기반 시스템을 위한 CMOS IR-UWB RFIC)

  • Lee, Jung Moo;Park, Myung Chul;Eo, Yun Seong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.67-73
    • /
    • 2015
  • This paper presents a fully integrated 3 - 5 GHz IR-UWB(impulse radio ultra-wide band) RFIC for Location based system. The receiver architecture adopts the energy detection method and for high speed sampling, the equivalent time sampling technique using the integrated DLL(delay locked loop) and 4 bit ADC. The digitally synthesized UWB impulse generator with low power consumption is also designed. The designed IR-UWB RFIC is implemented on $0.18{\mu}m$ CMOS technology. The receiver's sensitivity is -85.7 dBm and the current consumption of receiver and transmitter is 32 mA and 25.5 mA respectively at 1.8 V supply.

A New Prediction Method for Scintillation Expression

  • Chutchavong, Vanvisa;Nakasuwan, Jintana;Sangaroon, Ornlarp;Jenchitrapongvej, Kanok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2082-2086
    • /
    • 2003
  • This paper presents the analysis of satellite received signal by focus on the new prediction method for amplitude scintillation expression. A predict method based in the relationship of standard deviation values and the peak to peak values of amplitude scintillation in various of time period and various of sampling rate of signal variation. The principal techniques finding, the proper sampling rate and time interval, for the best expression method. The experiment has been performed in Bangkok of Thailand, at King Mongkut's Institute of Technology, Ladkrabang, data collected in C-Band and Ku-Band on high elevation angles. The result of analysis shows the relationship between two methods is given by ${\sigma}_x={\alpha}(P-P)+{\beta}$. The value of ${\alpha}$ depends on sampling rate by closely with three-minute maximum time interval.

  • PDF

Improved Group Acceptance Sampling Plan for Dagum Distribution under Percentiles Lifetime

  • Aslam, Muhammad;Shoaib, Muhammad;Khan, Hina
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.4
    • /
    • pp.403-411
    • /
    • 2011
  • This paper deals with a group acceptance sampling plan for time truncated tests which are based on the total number of failures from the whole group assuming that the life time of an item follows the Dagum (inverse Burr) distribution. This study is developed when a multiple number of items as a group can be tested simultaneously in a tester. The minimum number of groups required for a given group size and acceptance number is determined such that the producer and consumer risks are satisfied simultaneously at the specified quality level, while the termination time and the number of testers are specified. Comparisons are made between the proposed plan and the existing plan on the basis of size of the groups. Two real examples are provided.

Development and Comparisons of Bayesian Acceptance Sampling Plans for the Exponential Lifetime Distribution (지수 수명분포에 대한 Bayesian 합격판정 샘플링계획의 개발 및 비교에 관한 연구)

  • Jeong, Hyun-Seok;Jin, Hwi-Chul;Yum, Bong-Jin
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.20 no.1
    • /
    • pp.15-25
    • /
    • 1994
  • The Bayesian approach to reliability acceptance sampling has several advantages over the non-Bayesian approach. For instance, the former usually requires less amount of testing time and smaller sample sizes than the latter. In this article, a Bayesian acceptance sampling plan(ASP) based on a failure-free period life test is developed under the assumption of exponential lifetime distribution, and is compared with the corresponding Bayesian hybrid ASP in terms of the expected completion time. It is found that the proposed ASP tends to have a smaller expected completion time than the Bayesian hybrid ASP as the prior assessment of the reliability of a lot becomes optimistic, and vice versa. Tables of failure-free period Bayesian ASP's are also included.

  • PDF

Design of Membership Ranges for Robust Control of Variable Speed Drive Refrigeration Cycle Based on Fuzzy Logic (가변속 냉동사이클의 강인제어를 위한 퍼지로직의 멤버십함수 범위 설계)

  • Jeong, Seok-Kwon
    • Journal of Power System Engineering
    • /
    • v.22 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • This paper focuses on systematic design about the membership ranges of the main design factors such as control error, control error rate, and sampling time for the fuzzy logic control of the variable speed drive refrigeration cycle. The upper and the lowest limit of the membership ranges are set up from the data of static characteristics obtained by experiments. Three kinds of membership ranges on the control error and the control error rate are tested by experiments. Especially, an effect of sampling time on control performance is also investigated in the same way. Experimental data showed the control error rate and the sampling time strongly effected on the control performance of the refrigeration cycle with a variable speed drive.

Controling the Healthy Worker Effect in Occupational Epidemiology

  • Kim, Jin-Heum;Nam, Chung-Mo
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2002.11a
    • /
    • pp.197-201
    • /
    • 2002
  • The healthy worker effect is an important issue in occupational epidemiology. We proposed a new statistical method to test the relationship between exposure and time to death in the presence of the healthy worker effect. In this study, we considered the healthy worker hire effect to operate as a confounder and the healthy worker survival effect to operate as a confounder and an intermediate variable. The basic idea of the proposed method reflects the length bias-sampling caused by changing one's employment status. Simulation studies were also carried out to compare the proposed method with the Cox proportional hazards models. According to our simulation studies, both the proposed test and the test based on the Cox model having the change of the employment status as a time-dependent covariate seem to be satisfactory at an upper 5% significance level. The Cox models, however, are inadequate with the change, if any, of the employment status as time-independent covariate. The proposed test is superior in power to the test based on the Cox model including the time-dependent employment status.

  • PDF

Correction of TDC Position for Engine Output Measuring in Marine Diesel Engines (선박용 디젤엔진의 출력산정을 위한 TDC 위치보정에 관한 연구)

  • Jung, Kyun-Sik;Choi, Jun-Young;Jeong, Eun-Seok;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.459-466
    • /
    • 2012
  • The accurate engine output is basically one of important factors for the analysis of engine performance. Nowadays in-cylinder pressure analysis in internal combustion engine is also an indispensable tool for engine research and development, environment regulation and maintenance of engine. Here, it is essential more than anything else to find the correct TDC(Top Dead Center) position for the accuracy of engine output for diesel engine. Therefore this study is to analyze affecting factors to TDC position in 2-stroke large low speed engine and to suggest new method for determining correct TDC position. In the previous paper, it was mentioned that the accuracy of engine output is influenced by the determination of exact TDC position, and that 'Angle based sampling' method is better than 'Time based sampling' method in terms of precision. It was confirmed that there is 'Loss of angle', which is a difference between compression pressure peak and real TDC caused by heat loss and blow by of gas leakage. Consequently we invented new method, called "An improved method of time based sampling", which can obtain the correct engine output. The results by this method with compensating loss of angle was shown the same result by the 'Angle based sampling' method in encoder setting cylinder. This study is to suggest the new measuring method of exact engine output, and to examnine the reliance on the outcome.

Analysis and Compensation of Current Sampling Error in Discontinuous PWM Inverter for AC Drive (교류 전동기 구동용 불연속 PWM 인버터의 전류 샘플링 오차 해석 및 보상)

  • Song, Seung-Ho;Son, Yo-Chan;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.517-522
    • /
    • 1999
  • This paper addresses the issue of current sampling in a high performance AC drive system fed by a discontinuous PWM inverter. The effect of the sampling error due to the measurement delay produced by an input stage low pass filter and an A/D converter is described in the case of discontinuous PWM. To compensate for the sampling error, a method to estimate the delay time of the whole measurement system based on the measured current is proposed and its effectiveness is verified by experimental results. The proposed algorithm can automatically estimate the system delay introduced by the low pass filter and the A/D converter at the commissioning stage. By delaying the current sampling by the estimated value, experimental results indicate that more than 50% reduction of current ripple can be achieved.

  • PDF