• 제목/요약/키워드: Time Winding

검색결과 269건 처리시간 0.023초

유기 전압비를 이용한 3권선 변압기 보호계전 알고리즘 (A Three-Winding Transformer Protective Relaying Algorithm Based on the Induced Voltages)

  • 강용철;이병은
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.173-178
    • /
    • 2003
  • This paper proposes a three-winding transformer protective relaying algorithm based on the ratio of the induced voltages (RIV). The RIV of the two windings is the same as the turn ratio for all operating conditions except an internal fault. For a single phase and a three-phase transformer containing the wye-connected windings, the induced voltages of the windings are estimated. For a three-phase transformer containing the delta-connected windings, the induced voltage differences are estimated using the line currents, because the winding currents are practically unavailable. The algorithm can identify the faulted phase and winding if a fault occurs on one phase of a winding. The test results clearly show that the algorithm successfully discriminates internal winding faults from magnetic inrush. The algorithm not only does not require hysteresis data but also can reduce the operating time of a relay.

전압 증가에 따른 자속구속형 고온 초전도 전류제한기의 사고전류 제한 특성 (The Fault Current Limiting Characteristics According to Increase of Voltage in a Flux-Lock Type High-Tc Superconducting Fault Current Limiter)

  • 조용선;박형민;임성훈;박충렬;한병성;최효상;현옥배;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.93-96
    • /
    • 2004
  • In this paper, we analyzed the current limiting characteristics according to increase of source voltage in the flux-lock type high-Tc superconducting fault current limiter (SFCL). The flux-lock type SFCL consisted of two coils, which were wound in parallel each other through an iron core, and high-Tc superconducting (HTSC) element connected with coil 2 in series. The flux-lock type SFCL has the characteristics better in comparison with the resistive type SFCL because the fault current in the flux-lock type SFCL can be divided into two coils by the inductance ratio of coil 1 and coil 2. The fault current limiting operation of the flux-lock type SFCL can be different due to winding direction of the two coils. The winding method where the decrease of linkage flux between two coils in the accident happens is called the subtractive polarity winding and the winding method in case of the increase of linkage flux is called the additive polarity winding. The fault current limiting experiments according to the source voltage were performed for these two winding methods. Through the comparison and the analysis of the experimental data, we confirmed that the quench time was shorter, irrespective of the winding direction as the source voltage increased and that the fault current and the HTSC's resistance increased as the amplitude of the source voltage increased. The additive polarity winding made the fast quench time and the lower resistance of HTSC element in comparison with the subtractive polarity winding. The fault current of the subtractive polarity winding was larger than that of the additive polarity winding. In conclusion, we found that the additive polarity winding reduced the burden of SFCL because the quench time was shorter and the fault current was smaller than those of the subtractive polarity winding.

  • PDF

권선방식에 따른 무유도 권선형 HTS 코일의 퀜치 및 회복 비교특성 (Quench and Recovery Characteristics of Non-Inductively Wound HTS Coils with Various Winding)

  • 조현철;장기성;김영재;최석진;황영진;김원철;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.37-41
    • /
    • 2010
  • To limit fault current in a power system, superconducting fault current limiters (SFCLs) using high temperature superconducting (HTS) coils have been developed by many research groups so far. Non-inductive winding of HTS coils used for SFCLs can be classified into solenoid winding and pancake winding. Each of winding is expected to have different quench and recovery characteristics because the structure of solenoid winding differs from pancake winding's. Therefore it is important to the SFCLs application to investigate characteristics of each winding. In this paper, we deal with quench and recovery characteristics of four kinds of winding : solenoid winding, pancake winding without spacers, and with spacers of 2 and 4 mm thickness. In order to obtain quench and recovery parameters of coils, short circuit tests were performed in liquid nitrogen.

연속공정 시스템에서의 장력의 가변이득 PID 제어 (Variable-Gain PID Control of Longitudinal Tension in Web Transport System)

  • 신기현
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.724-730
    • /
    • 1995
  • Fixed-gain and variable-gain PID control of tension in the winding section of a simple web transport system were evaluated. An open-loop mathematical model for the web transport system was derived and used for the design of the PID controllers. The winding roll radius is a timevarying parameter in the model. The fixed-gain PID controller designed at a particular instant of time could not meet the desired specifications, whereas the variable-gain PID controller could produce accurate tension control in the winding section. An advantage of the variable-gain control is its simplicity. This approach is easy to implement and shows promise for applications where the time-varying parameters are easily measured.

계자제어에 의한 동기전동기의 난조방지 (Hunting Protection of Synchronous Motor by Field Control)

  • 한송엽
    • 전기의세계
    • /
    • 제20권2호
    • /
    • pp.19-26
    • /
    • 1971
  • To proteting hunting of synchronus motor a new one which has two field windings is designed. One is main field winding excited constantly and the other is control field winding excited only during the load of motor changes. The oscillation of the motor is controlled by increasing or decreasing the control field excitation. To determine the optimal field excitation the Pontryagin's minimum principle is applied. Also this paper gives the optimal trajectories of the motor and it's transition time. This motor has some of better properties than the old motor with damper winding. These phroperties are (1) there is no hunting (2) the transient stability is improved (3) transition time is very short.

  • PDF

면취기 시스템에 있어서 부하의 관성모멘트에 따른 가변 PID 일정 장력제어의 기초연구 (A Basic Study on the constant Tension control with variable PID as a function of inertia moment in the winding roll System)

  • 허진;전홍배;김철한;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.654-657
    • /
    • 2000
  • In the winding system, the constant tension control is too important. In this study, we've used a variable PID system as a function of a radius of winding roll. As a result, it was possible to measure a winding roll radius in the real time by making a mathematical model for measuring a winding roll radius. Finally, we've compared PID parameters as a function of winding roll radius after getting PID parameters in terms of the Ziegler & Nichols(ZN) method.

  • PDF

해석 시간 저감을 위한 전기 권선의 FEM 등가 권선법 (A Study on FEM Equivalent Winding Method for Reducing Analysis Time)

  • 박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.835-840
    • /
    • 2023
  • 2D FEM은 3D FEM에 비하여 모델 및 조건을 간소화하여 해석할 수 있다. 하지만 코일의 조건에 대하여는 실제 코일의 인입과 반출을 순차적으로 구성하여 해석 조건에 입력하는 경우가 많다. 본 논문은 다수의 슬롯을 가지더라도 하나의 FEM Coil로 구성한 등가 권선법을 적용하여 코일 조건의 단순화 및 해석 시간의 단축을 나타내고 권선형 마그네틱 기어에 적용하여 결과의 일치성을 보인다.

자속구속형 고온초전도 사고전류 제한기의 사고제거 후 회복특성 (Recovery Characteristics of a Flux-lock Type HTSC Fault Current Limiter after Fault Removal)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.812-815
    • /
    • 2007
  • To apply the superconducting fault current limiter(SFCL) into a power system, the analysis for its recovery characteristics as well as the consideration for its cooperation with other protecting machine such as a circuit breaker is required. The recovery characteristics of the flux-lock type SFCL like its current limiting characteristics are dependent on the winding direction of two coils. In this paper, the experiments of the current limiting and the recovery characteristics of the flux-lock type SFCL with YBCO thin film were performed. From the analysis on the experimental results due to the winding direction of two coils, the limited fault current in case of the additive polarity winding was observed to be lower than that for the case of the subtractive polarity winding. In addition, the recovery time was found to be faster in case of the additive polarity winding compared to the subtractive polarity winding.

생분해성 랩 와인딩 기계의 장력제어를 위한 모델링 (Modeling for Tension Control of the Bio-Wrap Winding Machine)

  • 박우철;김해성;김동일;양성모;기창두
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1901-1905
    • /
    • 2005
  • This Paper describes the mathematical modeling and control of the tension and the speed of moving Bio-wrap in a wrap winding machine. In winding process, important control specifications include the regulation of wrap tension and velocity. In this research, a tension and velocity model has been developed for winding processes. A prototype winding system has been constructed, and the controller has been implemented in a real time PC-based environment. The tension control system is modeled a MIMO of the two-input and four-output system. The performance of the modeled system has been evaluated via simulation using MATLAB and experiments.

  • PDF

고정자권선의 절연열화 특성분석 (Analysis of the Insulation aging for the stator winding)

  • 오봉근;최교남;한창동;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF