• Title/Summary/Keyword: Time Spacing

Search Result 446, Processing Time 0.026 seconds

The Fast Correlative Vector Direction Finder Conversion (직접 변환을 이용한 고속 상관형 벡터 방향탐지기)

  • Park, Cheol-Sun;Kim, Dae-Young
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.12 s.354
    • /
    • pp.16-23
    • /
    • 2006
  • This paper presents the development of the fast Direction Finder using direct conversion method, which can intercept for short pulse signal of less' than 1 msec. in RF Down Converter, and CVDF(Correlative Vector Direction Finding) algorithm, which estimates DoA (Direction of Arrival). The configuration and characteristics of direction finder using 5-channel equi-spaced circular array antenna are presented and the direct conversion techniques for removing tuning time using I/Q demodulator are described. The CRLB of our model is derived, the principles of 2 kind of CVDF algorithm are explained and their characteristics are compared with CRLB w.r.t the number of samples and spacing ratio. The RF Down Converter prototype using direct conversion method is manufactured, the 2 kind of CVDF algorithm are applied and their performance are analyzed. Finally it is confirmed the LSE based CVDF algorithm is better than correlation-coefficient based except for ambiguity protection capabilities.

A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society (18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색)

  • Chung, Jung-Nam
    • Journal of architectural history
    • /
    • v.27 no.3
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

Review of Contraceptive Distribution Strategy for the Korean National Family Planning Program (정부가족계획사업의 피임보급전략에 관한 소고)

  • 조남훈;장영식
    • Korea journal of population studies
    • /
    • v.5 no.1
    • /
    • pp.117-132
    • /
    • 1982
  • During the period of 1962 through 1981, a total of 11. 7 million cummulative acceptors have received contraceptive services under the national family planning program. The number of annual acceptors have steadly increased from 151, 200 in 1963 to 842, 200 in 1975, and since then it has maintained the range of 600, 000 to 800, 000 acceptors per year. From the beginning of the program, the IUD had been the principal method of contraception provided by the government program until 1976, at which time the government made female sterilization services available thorough the introduction of the laparoscopy method. The popularity of female sterilization has increased very rapidly during the last few years. Out of 614, 200 program acceptors in 1981, the proportion of female sterilization and IUD acceptors were virtually the same(26.8% and 27.2% respectively). Considering various anticipated problems such as a large proportion of contraceptive users for the fertility termination and the high discontinuation rates of IUD and other traditional method, the government has emphasized the distribution of female sterilization and deemphasized condom and pill contraceptives since 1978. However, the recent service statistics has revealed that the acceptance rate of female sterilization has steadly declined since 1979. Thus, the purpose of this analysis is to review the current government policy on contraceptive distribution with emphasis of female sterilization by estimating the prospect of sterilization acceptablilty. According to the Fifth Five-Year Plan for Family Planning Program(1982-1986) the annual average target of sterilization was set up to secure 230, 000 acceptors by the government sector during the period. If the sterilization target is to be met as planned, about 80 percent of exposed women aged 30-44 will be remained as sterilized women in 1985. This means the the high acceptance rate of sterilization shown in the past years can not be expected, unless the acceptors' age of sterilization is drastically lowered below 30 years. Accordingly, the current policy on contraceptive distribution with emphasis on sterilization should be gradually changed to encourage target population to use contraceptives for birth spacing by increasing access to such contraceptives as IUDs, pills, and condoms, and to improve continuation rates through better program management system including target setting, acceptors' follow-up, supervision, and evaluation system.

  • PDF

Sound Transmission Loss Measurement for Sound Isolation Sheets by Two-Microphone Impedance Tube Method (두 개의 마이크로폰의 부착된 임피던스관법을 이용한 차음시트의 음향투과손실 측정)

  • Lee, Dong-Hoon;Yong, Ho-Taek;Lee, Seung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.63-72
    • /
    • 2002
  • The main objective of this study is to propose a practical two-microphone impedance tube method to measure the sound transmission loss for flexible sound isolation sheets without the use of the time-consuming and expensive reverberation room. This method was based on the sound decomposition theory developed by Seybert using the spectral density functions of the incident and reflected sound waves. In order to verify the validity of the experimental results, the measured sound transmission losses from the proposed method were compared with the measured data from the reverberation room method and the calculated data from the theory satisfying the mass law of sound isolation material. The resulted trends of the sound transmission losses versus frequencies for several different sound isolation sheets were almost same for each other and agreed quite well in both methods except at some low frequency region. From the experimental results, it was found that the accuracy of sound isolation capability obtained by two-microphone impedance tube method depends upon the microphone spacing, the distance from the first microphone to the test sample surface and the test sample location.

Study on the Development of Reinforced Earth Retaining Wall (보강옹벽개발연구)

  • 유용환
    • Geotechnical Engineering
    • /
    • v.2 no.3
    • /
    • pp.51-66
    • /
    • 1986
  • The design of fabric reinforced retaining wall structure was discussed in this article. It was confirmed that the reinforced retaining earth wall which was designed by new theoretical formulae developed this time was stable structurally and economically. The plastic fabric filter which was placed in layers behind the facing element reduced the lateral earth pressure on the wall elements in comparison with a conventional retaining earth walls. The reinforcing characteristics of earth wall was governed by the spacing of fabric layers, effective length of fabrics, particle distribution and compaction, and thus it is essential that, in the construction field, the reinforcing strips should be selected in order to develop the maximum friction forces bet.eon soil and fabric filters. The maximum tensile stress developed from the reinforcing strips was appeared at a little far distance from the back of skin element and it was not well agreed with the Rankine's theory but distributed well as a symmetrical shape against the point of the maximum tensile stress. The total length of the different layers should be sufficient so that the tension in the fabric strip could be transferred to the backfill material. Also the total stability of reinforced earth wall should be checked with respect to a failure surface which extended blond the different lathers.

  • PDF

Discharge and Ozone Generation Characteristics by Permittivity of Dielectric Material installed in Water Surface Discharge (수표면 방전에 투입된 유전체의 유전율에 따른 방전 및 오존발생특성)

  • 박승록;김진규;김형표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.56-63
    • /
    • 2003
  • A silent type ozone generator using water surface has been studied and improved its ozone generation characteristics by installing dielectric heads in the just under the surface of the wale- At this time, different permittivitis of dielectric beads were used to change the discharge condition of water surface. The current-voltage characteristics and characteristics of ozone generation quantity of the test system were investigated and discharge photos of glass beads were observed The height of Taylor cone may be the cause of the discharge bridge to decrease the ozone generation on the discharge spacing. In this study, the hight of Taylor cone could be controlled greatly by installing dielectric beads just under the water surface. Therefore a higher ozone generation also could be obtained. As the permittivity of dielectric material increased. discharge starting voltage was advanced and maximum 110 ppmy of ozone was generated by using the ferroelectric ball.

Development of a Path Generation and Tracking Algorithm for a Korean Auto-guidance Tillage Tractor

  • Han, Xiong-Zhe;Kim, Hak-Jin;Moon, Hee-Chang;Woo, Hoon-Je;Kim, Jung-Hun;Kim, Young-Joo
    • Journal of Biosystems Engineering
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: Path planning and tracking algorithms applicable to various agricultural operations, such as tillage, planting, and spraying, are needed to generate steering angles for auto-guidance tractors to track a point ahead on the path. An optimal coverage path algorithm can enable a vehicle to effectively travel across a field by following a sequence of parallel paths with fixed spacing. This study proposes a path generation and tracking algorithm for an auto-guided Korean tractor with a tillage implement that generates a path with C-type turns and follows the generated path in a paddy field. A mathematical model was developed to generate a waypoint path for a tractor in a field. This waypoint path generation model was based on minimum tractor turning radius, waypoint intervals and LBOs (Limit of Boundary Offsets). At each location, the steering angle was calculated by comparing the waypoint angle and heading angle of the tractor. A path following program was developed with Labview-CVI to automatically read the waypoints and generate steering angles for the tractor to proceed to the next waypoint. A feasibility test of the developed program for real-time path tracking was performed with a mobile platform traveling on flat ground. The test results showed that the developed algorithm generated the desired path and steering angles with acceptable accuracy.

Identification of Guided-Wave Modes in Pipings of Power Plants by using Air-coupled Transducer (Air-coupled 트런스듀서를 이용한 발전설비 배관에서의 유도초음파 모드 규명)

  • Park, Ik-Keun;Kim, Hyun-Mook;Kim, Yong-Kwon;Song, Won-Joon;Cho, Yong-Sang;Jhang, Kyung-Young;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.341-347
    • /
    • 2004
  • In order to inspect the piping effectively, one of the important components in the facility of power plants, the ultrasonic guided wave was generated by a tomb transducer and was received in a non-contact fashion by using an air-coupled transducer. The guided wave modes that ran be generated by the comb transducer in piping are predicted from the theoretical dispersion curves and the element spacing of a comb transducer. Moreover, to receive the specific modes, the receiving angle of the air-coupled transducer is calculated from Snell's law between the phase velocities of guided waves and the sound velocity of air. The guided wave modes obtained in experiments are identified from the result of time-frequency analysis such as wavelet transform and two-dimensional fast Fourier transform.

Dynamic behavior of SRC columns with built-in cross-shaped steels subjected to lateral impact

  • Liu, Yanhua;Zeng, Lei;Liu, Changjun;Mo, Jinxu;Chen, Buqing
    • Structural Engineering and Mechanics
    • /
    • v.76 no.4
    • /
    • pp.465-477
    • /
    • 2020
  • This paper presents an investigation on the dynamic behavior of SRC columns with built-in cross-shaped steels under impact load. Seven 1/2 scaled SRC specimens were subjected to low-speed impact by a gravity drop hammer test system. Three main parameters, including the lateral impact height, the axial compression ratios and the stirrup spacing, were considered in the response analysis of the specimens. The failure mode, deformation, the absorbed energy of columns, as well as impact loads are discussed. The results are mainly characterized by bending-shear failure, meanwhile specimens can maintain an acceptable integrity. More than 33% of the input impact energy is dissipated, which demonstrates its excellent impact resistance. As the impact height increases, the flexural cracks and shear cracks observed on the surface of specimens were denser and wider. The recorded time-history of impact force and mid-span displacement confirmed the three stages of relative movement between the hammer and the column. Additionally, the displacements had a notable delay compared to the rapid changes observed in the measured impact load. The deflection of the mid-span did not exceed 5.90mm while the impact load reached peak value. The impact resistance of the specimen can be improved by proper design for stirrup ratios and increasing the axial load. However, the cracking and spalling of the concrete cover at the impact point was obvious with the increasing in stiffness.

Experimental study on seismic behavior of reinforced concrete column retrofitted with prestressed steel strips

  • Zhang, Bo;Yang, Yong;Wei, Yuan-feng;Liu, Ru-yue;Ding, Chu;Zhang, Ke-qiang
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1139-1155
    • /
    • 2015
  • In this study, a new retrofitting method for improving the seismic performance of reinforced concrete column was presented, in which prestressed steel strips were utilized as retrofitting stuff to confine the reinforced concrete column transversely. In order to figure out the seismic performance of concrete column specimen retrofitted by such prestressed steel strips methods, a series of quasi-static tests of five retrofitted specimens and two unconfined column specimen which acted as control specimens were conducted. Based on the test results, the seismic performance including the failure modes, hysteresis performance, ductility performance, energy dissipation and stiffness degradation of all these specimens were fully investigated and analyzed. And furthermore the influences of some key parameters such as the axial force ratios, shear span ratios and steel strips spacing on seismic performance of those retrofitted reinforced concrete column specimens were also studied. It was shown that the prestressed steel strips provided large transverse confining effect on reinforced concrete column specimens, which resulted in improving the shearing bearing capacity, ductility performance, deformation capacity and energy dissipation performance of retrofitted specimens effectively. In comparison to the specimen which was retrofitted by the carbon fiber reinforced plastics (CFRP) strips method, the seismic performance of the specimens retrofitted by the prestressed steel strips was a bit better, and with much less cost both in material and labor. From this research results, it can be concluded that this new retrofitting method is really useful and has significant advantages both in saving money and time over some other retrofitting methods.