• Title/Summary/Keyword: Time Rate

Search Result 23,545, Processing Time 0.044 seconds

The Effects of Drying Conditions on the Germination Properties of Rapeseed (유채종자의 건조조건에 따른 발아특성)

  • Duc, Le Anh;Han, Jae-Woong
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.30-36
    • /
    • 2009
  • This study was performed to determine the effect of drying conditions on the germination properties of rapeseed after seeds were dried under different drying conditions: $40^{\circ}C$, $50^{\circ}C$, or $60^{\circ}C$ in combination with 30%, 45%, or 60% relative humidity. As analytic results, drying conditions had significant effects (P-value < 0.001) and drying temperature was considered as the main factor on the germination properties of rapeseed. When drying temperature increased or relative humidity decreased, the vigor rate and germination rate decreased, the median germination time increased. The maximum values of vigor rate and germination rate were 90% and 95.44%, and their minimum values were 60.17 and 75%, respectively. To ensure the standard germination rate of 85%. The appropriate drying zone was determined and the drying temperature should be less than $51.0^{\circ}C$, $54.5^{\circ}C$ and $58.7^{\circ}C$ at 30%, 45% and 60% RH, respectively. The values for median germination time varied from 2 to 4 days. The predicted models of germination rate, vigor rate, and median germination time were determined.

EFFECT OF LIGHT INTENSITY ON THE POLYMERIZATION RATE OF COMPOSITE RESIN USING REAL-TIME MEASUREMENT OF VOLUMETRIC CHANCE (광조사 강도가 복합레진의 중합반응속도에 미치는 영향에 관한 실시간 체적측정법을 이용한 연구)

  • La, Sung-Ho;Lee, In-Bog;Kim, Chang-Keun;Cho, Byeong-Hoon;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.135-141
    • /
    • 2002
  • Objectives : The aim of this study is to evaluate the effect of light intensity variation on the polymerization rate of composite resin using IB system (the experimental equipment designed by Dr. IB Lee) by which real-time volumetric change of composite can be measured. Methods : Three commercial composite resins [Z100(Z1), AeliteFil(AF), SureFil(SF)] were photopolymerized with Variable Intensity Polymerizer unit (Bisco, U.S.A.) under the variable light intensity (75/150/225/300/375/450mW$^2$) during 20 sec. Polymerization shrinkage of samples was detected continuously by IB system during 110 sec and the rate of polymerization shrinkage was obtained by its shrinkage data. Peak time(P.T.) showing the maximum rate of polymerization shrinkage was used to compare the polymerization rate. Results : Peak time decreased with increasing light intensity(p<0.05). Maximum rate of polymerization shrinkage increased with increasing light intensity(p<0.05). Statistical analysis revealed a significant positive correlation between peak time and inverse square root of the light intensity (AF:R=0.965, Zl:R=0.974, SF:R=0.927). Statistical analysis revealed a significant negative correlation between the maximum rate of polymerization shrinkage and peak time(AF:R=-0.933, Zl:R=-0.892, SF:R=-0.883), and a significant positive correlation between the maximum rate of polymerization shrinkage and square root of the light intensity (AF:R=0.988, Zl:R=0.974, SF:R=0.946). Discussion and Conclusions : The polymerization rate of composite resins used in this study was proportional to the square root of light intensity Maximum rate of polymerization shrinkage as well as peak time can be used to compare the polymerization rate. Real-time volume method using IB system can be a simple alternative method to obtain the polymerization rate of composite resins.

A Method for Determining Dead Times of a G.M. Defector as a Function of the Count Rate

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 1971
  • A method for determining dead times of a G.M. detector as a function of the count rate has been investigated using the Mn$^{56}$ radioactive sample. The formula, (equation omitted), seems to be useful for determining a relation between the dead time and the count rate. Here (equation omitted)(N$_1$) is the dead time for the count rate N$_1$, N$_1$is the count rate at time zero, Nt is the count rate at time t, λ is the radioactive decay constant of the sample used, and t is the time between the first and second runs. When all the counting data were corrected for the dead times evaluated with this formula and then a variation of these corrected counting data with rime was observed, the results showed quite a good agreement with the published data for the radioactive decay of Mn$^{56}$ . Besides, it appears that the dead time decreases as the count rate increases in a dead time-to-count rate relation obtained by the same formula.

  • PDF

Ballistocardiographical Heart Rate Measurement Using Head Mounted 6-axis Accelerometer (머리 착용형 6축 가속도계를 사용한 심탄도 심박수 측정)

  • Jinman Kim;Joongjin Kook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.33-37
    • /
    • 2024
  • Recently, wearable virtual reality devices are widely used. These instruments include a 3-axis accelerometer. User's heart rate information in virtual reality contents can be useful for measuring user experience. In this paper, we propose a method to measure the heart rate through a 3-axis accelerometer based on the principle of ballistocardiography without additional sensors. The angular velocity was successively measured in a time series by the 3-axis accelerometer mounted to the head. The frequency of the maximum magnitude is determined as the heart rate through frequency transform and band pass filtering of the time series signal. For verification, the heart rate calculated from photoplethysmography sensors acquired at the same time was compared as ground-truth. In the virtual reality, the user's heart rate information can be extracted without additional heart rate sensor, and the emotional state and fatigue can be measured.

  • PDF

A study on the Enhancement for Minimum Connecting Time of Incheon International Airport (인천국제공항의 MCT 향상을 통한 환승율 제고의 탐색적 연구)

  • Lee, Kang-Suk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.4
    • /
    • pp.117-130
    • /
    • 2007
  • Incheon International Airport has handled 3,054,485 transfer passengers (11.9% transfer rate) and 950,441 transfer cargo(44.2% transfer rate)recorded in 2005. Comparing to 30-40% transfer passenger rate which are competition hub airports in northeast Asia, transfer passenger rate of Incheon International Airport is lower. Above all, We think that Minimum Connecting Time(MCT) which is relating factors with transfer rate need to be monitored to make up for the weak points in the current Incheon internationalairport system. Minimum Connecting Time is defined the legally minimum time necessary to change planes at a given airport. and Transfers represent 35% of the total passenger volume at Vienna International Airport in Europe, which underscores our function as a major international hub. Vienna is rated priority in reservation systems because of our excellent minimum connecting time, and that increases the sale of tickets through our airport. In 2004 the total number of transfer passengers rose 18% to 5,089,624. Short routes, a one roof concept and an outstanding logistics system make Vienna an ideal airport for transfers. This transfer-friendly one roof concept will also form the basis for the new VlE-Skylink Terminal. In case of Japan, Star Alliance has also implemented its so called "Move under one roof"concept at the new Centrair airport. All member carriers are located in the same part of the termina1, sharing check-in counters and ticketing facilities. Star Alliance member carriers can now offer customersa reduced average minimum connecting time of one hour, for transfers between international and domestic. The research purpose of the Study on the Enhancement for Minimum Connecting Time of Incheon International Airport is to increase transfer rate of passenger and cargo of Incheon International Airport at Northeast Asia through this paper.

  • PDF

Performance of a Biofilter for Odor Removal during Manure Composting

  • Park, K.J.;Hong, J.H.;Choi, M.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.59-64
    • /
    • 2002
  • Odor generated during composting of livestock manure is mainly due to ammonia emission. Biofiltration is a desirable method to control composting odor. This study was conducted to analyze the efficiency of using fresh compost as a biofilter. A mixture of cattle manure and recycled compost was composted in a bin equipped with a suction-type blower. The exhaust gas was filtered through the fresh compost. Residence time was controlled by the flow rate of exhaust gas and the depth of filtering materials. At the aeration rate of 30 L/min(experiment I), ammonia reduction rate varied from 100% to -15% for biofilter A(residence time 56.5 s) and almost 100% for biofilter B(residence time 113 s). At the aeration rate of 30 L/min, the cumulative ammonia reduction rate was 80.5% for biofilter A and 99.9% for biofilter B. At the aeration rate of 50 L/min(experiment II), the lowest reduction rate showed a negative value of -350% on the 8th and 9th day for biofilter A(residence time 33.9 5), and 50% on the loth day for biofilter B(residence time 67.8s). At the aeration rate of 50 L/min, the cumulative ammonia reduction rate was 82.5% fur biofilter A and 97.4% for biofilter B. Filtering efficiency was influenced by residence time. The moisture content(MC) and total nitrogen(T-N) of the filtering material were increased by absorbing moisture and ammonia included in the exhaust gas, while pH was decreased and total carbon(T-C) remained unchanged during the filtering operation.

  • PDF

Evaluation of Operation Characteristics with Aeration Time in Intermittent Aeration Membrane Bioreactor (간헐포기 MBR공정에서 포기시간에 따른 운전특성 평가)

  • Lim, Bong-Su;Choi, Bong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.353-359
    • /
    • 2005
  • This study was conducted to evaluate the operation characteristics with aeration time in intermittent aeration membrane bioreactor. The BOD removal efficiency rate of this process was over than 97% regardless of aeration on/off time. To get over than 82% of nitrogen removal efficiency rate, aeration off time needs more than 70 minutes in reactor. Specific denitrfication rate was 2.68 mg $NO_3-N/gMv/hr$ in 40/80 min aeration on/off time, was 2.6 times more than 60/60 min, and 1.4 times more than 50/70 min in 6,300 mg/L of MLSS concentration. Specific nitrification rate was 1.96 mg $NH_4-N/gMv/hr$ in 50/70 min, was 1.4 times more than 40/80 min, but it was effectded little upon nitrification. Microbial activity was effected little according to aeration on/off time, oxygen demend was reduced according to aeration off time increased and microbial concentration increased. The longer aeration off time become, the higher Extraceller Pollymeric Substance (EPS), 50/70 min and 40/80 min in aeration on/off time was increased 1.6 times and 2.7 times, respectively more than 60/60 min because of increase of operation pressure.

A Clinical Evaluation of the Tumor Volume Doubling Time in Primary Bronchogenic Carcinoma (폐암환자에서 본 Tumor Doubling Time 의 임상적 의의)

  • 홍기우;이홍균
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.15-22
    • /
    • 1973
  • The definition of cancer, its diagnosis and its prognosis all depend upon description of growth. To the layman a synonym for cancer is a "growth". There are no quantitative terms for the description of growth or growth rate in clinical use. There has been no attempt to assign values that would define "rapidly" or "slowly" growing. Estimates of growth potentiality are implied in the descriptive phrases "poorly differentiated" or "well differentiated", "highly malignant" or "low grade malignancy". and in systems of grading. These qualifying terms represent a personal impression, clinically useful in prognosis, but relative in nature. They do not lend themselves to uniform application or precise measurement for purpose of comparison. Growth is related to size and time. The volume of tumor depends upon the duration of the period of growth and the rate of growth. If the interval and change in volume are known. the average growth rate can be determined. If the growth rate is determined, and assumed to be constant., the duration of a given tumor and the time of inception can be estimated. The commonest concept of the origin of cancer is that as a result of a mutation involving a single cell, succeeding divisions of cells establish a colony with the characteristics recognizable as cancer. If the growth rate of the hypothetical tumor were constant it could be described in terms of "tumor volume doubling time". In the department of thoracic surgery of St. Mary hospital in Catholic Medical College, a clinical evaluation for the growth rate, degree of malignancy, resectability and prognosis was done on a total 24 cases of primary bronchogenic carcinoma which contour was significant on the chest X-ray film as possible estimating the tumor volume doubling time. The following results were obtained: 1. In the cases of 6.0cm or more in diameter of minor size at operation the resectability rate was lower and in the cases of 60 days or more in the tumor or volume doubling time the resectability rate was higher. 2. If differentiation of cancer cells was lower graded in tissue pathology, the tumor volume was shorter and the resectability rate was lower. 3. The tumor volume doubling time of the primary bronchogenic carcinoma occured more over 60 years of age was slightly shorter than under 60 years of age. 4. The tumor size at operation was more important to evaluate the survival time and prognosis than the tumor volume doubling time because the tumor growth was not always constant, we presume.mor volume doubling time because the tumor growth was not always constant, we presume.

  • PDF

Precedence Analysis of Traffic Safety Facilities Installation for Traffic Accidents (교통안전시설 설치의 교통사고 발생에 대한 선행성 분석)

  • Joo, Il-Yeob
    • Korean Security Journal
    • /
    • no.55
    • /
    • pp.31-55
    • /
    • 2018
  • The purpose of this study is to analyze the precedence analysis of traffic safety facilities installation for traffic accidents. The main results were as follows. First, the precedence of the number of traffic safety signs installation for the number of traffic accident is follows. The number of traffic safety signs[total number] (time precedent 1), the number of traffic safety signs[attention] (time precedent 7), the number of traffic safety signs[regulation] (time precedent 7), the number of traffic safety signs[indication] (time precedent 4) precede the number of traffic accidents as negative(-) relationship. Second, the number of traffic signal equipments[pedestrian lamp] (time precedent 2) precedes the number of traffic accidents as negative(-) relationship. Third, the precedence of the increase/decrease rate of traffic safety facilities installation for the increase/decrease rate of traffic accident is follows. The increase/decrease rate of traffic safety signs[total number] (time precedent 1), the increase/decrease rate of traffic safety signs[attention] (time precedent 1), the increase/decrease rate of traffic safety signs[indication] (time precedent 1), the increase/decrease rate of traffic safety signs[auxiliary] (time precedent 1) precede the increase/decrease rate of traffic accidents as negative(-) relationship. Fourth, the increase/decrease rate of traffic signal equipments[pedestrian lamp] (time precedent 0) accompanies the increase/decrease rate of traffic accidents as positive (+) relationship.

Multivariate Mean Inactivity Time Functions with Reliability Applications

  • Kayid, M.
    • International Journal of Reliability and Applications
    • /
    • v.7 no.2
    • /
    • pp.127-140
    • /
    • 2006
  • AIn this paper we introduce and study a multivariate notions of mean inactivity time (MIT) functions. Basic properties of these functions are derived and their relationship to the multivariate conditional reversed hazard rate functions is studied. A partial ordering, called MIT ordering, of non-negative random vectors is introduced and its basic properties are presented. Its relationship to reversed hazard rate ordering is pointed out. Finally, using the MIT ordering, a bivariate and multivariate notions of IMIT (increasing mean inactivity time) class is introduced and studied.

  • PDF