• Title/Summary/Keyword: Time Rate

Search Result 23,678, Processing Time 0.058 seconds

Comparison of Respiratory Mechanics and Gas Exchange Between Pressure-controlled and Volume-controlled Ventilation (압력조절환기법과 용적조절환기법의 호흡역학 몇 가스교환의 비교)

  • Jeong, Seong-Han;Choi, Won-Jun;Lee, Jung-A;Kim, Jin-A;Lee, Mun-Woo;Shin, Hyoung-Shik;Kim, Mi-Kyeong;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.662-673
    • /
    • 1999
  • Background : Pressure-controlled ventilation (PCV) is frequently used recently as the initial mode of mechanical ventilation in the patients with respiratory failure. Theoretically, because of its high initial inspiratory flow, pressure-controlled ventilation has lower peak inspiratory pressure and improved gas exchange than volume-controlled ventilation (VCV). But the data from previous studies showed controversial results about the gas exchange. Moreover, the comparison study between PCV and VCV with various inspiration : expiration time ratios (I : E ratios) is rare. So this study was performed to compare the respiratory mechanics and gas exchange between PCV and VCV with various I : E raitos. Methods : Nine patients receiving mechanical ventilation for respiratory failure were enrolled. They were ventilated by both PCV and VCV with various I : E ratios (1 : 2, 1 : 1.3 and 1.7 : 1). $FiO_2$, tidal volume, respiratory rate and external positive end-expiratory pressure (PEEP) were kept constant throughout the study. After 20 minutes of each ventilation mode, arterial blood gas, airway pressures, expired $CO_2$ were measured. Results : In both PCV and VCV, as the I : E ratio increased, the mean airway pressure was increased, and $PaCO_2$ and physiologic dead space fraction were decreased. But P(A-a)$O_2$ was not changed. In all three different I : E ratios, peak inspiratory pressure was lower during PCV, and mean airway pressure was higher during PCV. But $PaCO_2$ level, physiologic dead space fraction and P(A-a)$O_2$ were not different between PCV and VCV with three different I : E ratios. Conclusion : There was no difference in gas exchange between PCV and VCV under the same tidal volume, frequency and I : E ratio.

  • PDF

A Study on the Double-Wall Greenhouse Filled with Styrene Pellets (입자충전형 이중벽 온실에 관한 연구)

  • 이석건;이종원;이현우
    • Journal of Bio-Environment Control
    • /
    • v.4 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • This study was conducted to develope the automatic insulation system which control inside temperature of the greenhouse. For this purpose, the double- wall greenhouse and system which could automatically supply and discharge styrene pellets were constructed and abrasion of the pellets, blower ability, insulating property, transmittance and shading effect were analyzed by the experiments. The results obtained from this study can be summarized as follows : 1. It took an hour and fifteen minutes to supply and discharge about 2㎥ pellets in the experimental greenhouse. However, it is possible to reduce the operation time by proper selection of the blower and exhaust port, and by proper control of the supply and return pipe. 2. It was founded that the indirect delivery way was more profitable than the direct one in the supply and return of pellets. 3. When the transmittance was measured between 10 a.m. and 3 p.m., the average light transmissivity rate was 67%. 4. In winter nighttime, the inside temperature of the double- wall greenhouse with out the pellets was higher than the outside temperature by 3.4$^{\circ}C$ on an average. However, the inside temperature of the double - wall greenhouse with insulated area 73% was higher than the outside by one 6.6$^{\circ}C$ on an average, and the inside temperature of the greenhouse with insulated area 100% was higher than outside one by 13.5$^{\circ}C$ on an average. Therefore, it was proved that the insulating ability of the double - wall greenhouse in nighttime was excellent. 5. When the outside temperature was 36.9$^{\circ}C$ on an average, the inside temperature of the double- wail greenhouse with insulated area 100% was 3$0^{\circ}C$ on an average. As the inside temperature was lower than the outside one by 7$^{\circ}C$ on an average, we could know that the shading effects of the double- wall greenhouse were excellent in summer daytime.

  • PDF

Influences of Tunnel Covering Materials and Seeding Dates on the Growth and Productivity of Water Spinach (Ipomoea aquatic F.) under Unheated Greenhouse (공심채 무가온 하우스 재배시 터널피복재와 파종시기에 따른 생육과 생산성 비교)

  • Uhm, Mi Jeong;Kwon, Sung Whan;Song, Young Ju
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.349-355
    • /
    • 2014
  • This study was performed to evaluate influences of tunnel covering materials and seeding dates on the growth and productivity of water spinach (Ipomoea aquatic F.) cultured early in unheated greenhouse. During tunnel installation period, from March 5 to April 30 and from October 11 to November 10, air and soil temperature in tunnel covered with polyethylene film (PEF) had risen $2.0-2.4^{\circ}C$ and $0.9-1.0^{\circ}C$, respectively, compared to those in non-tunnel (NT). Air and soil temperature in tunnel with illite non-fabric (INF) also had risen $1.6-1.8^{\circ}C$ and $0.6-0.8^{\circ}C$, respectively. Especially, it showed greater effects of the rise at low temperature time zones of the day. In plots of seeding on March 15 in tunnel covered with PEF or INF, temperature during emergence period, emergence days and rate were similar to plot seeding on April 5 in NT. There were two more harvesting in plots of seeding on March 5 or March 15 in tunnel, and increasing of total yield by 22.5-25.7% compared to plot of seeding on April 5 in NT. But there was observed no significant differences between PEF and INF. Whereas PEF was necessary to be removed at midday sometimes because it had risk of high temperature injury, INF was not necessary. All above suggest that it was suitable to sow seed on the middle of March in tunnel covered with INF, for early culture of water spinach in unheated greenhouse.

Effects of Strength Recognition on the Intent of Start-up after Retirement: To the Office Workers (강점인식이 은퇴 후 창업의도에 미치는 영향: 직장인을 대상으로)

  • Park, Hye sung;Park, Woojin;Yun, Bae byung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.1
    • /
    • pp.143-150
    • /
    • 2020
  • This research is intended to identify how office worker's recognition of strength affects the intention of starting a business when it is used as a medium for utilizing strength. The survey period was conducted for two months from January 17, 2019 to March 8, 2019. In order to achieve the object of this study, a significant number of employees have been collected nationwide, and 287 office workers were analyzed after collecting 300 questionaires, excluding 13 office workers who were not sincere. The significant data were analyzed by utilizing the structural equation and technical statistics and by verifying the conformity of structural model and measurement model and by investigating the relationship between variables. The results of this study are summarized as follows: First, employee's perception of strength has been found to have a significant effect on the utilizing of strength. Second, the use of workers' strengths has been found to have a significant effect on the intention of starting a business. Third, it has been confirmed that in the relationship between the employee's perception of strength and intention to start a business, the recognition of strength has a significant effect on the intention of starting a business only through the use of strength. Most office workers are nervous about the future and make various plans. The time to live after retirement is getting longer and jobs and working hours are shrinking at an alarming rate. According to the analysis on the status of small business owners in the mid-term of 2017 data, the average monthly operating profit of small business owners across the country is decreasing over the years, and most start-ups are subsistence-type start-ups, and they decide to start their own businesses because they have no other choice than start-ups. As the number of small business owners suffering from financial difficulties has increased since the financial crisis and insecurity of job is pushing those with financial difficulties after retirement to the battleground of the start-up market, the result of this research suggest that the workers need to recognize their own strength and enhance the importance of utilizing the strength.

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Immune responses of hepatitis B vaccination among very low birth weight infant (극소 저출생체중아의 영아기 B형 간염 항체 생성률 조사)

  • Kim, Young-Deuk;Han, Myung-Ki;Kim, Ai-Rhan E.;Kim, Ki-Soo;Pi, Soo-Young
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.8
    • /
    • pp.857-863
    • /
    • 2006
  • Purpose : To evaluate the immunogenicity of hepatitis B vaccine among very low birth weight infants(VLBWI) who were vaccinated at 0, 1, 6 months of chronological age and to determine the factors associated with antibody formations. Methods : A total of 243 VLBWI admitted to Seoul and Gangneung Asan Medical Center neonatal intensive care units from 1997 to 2004 were included. Of 243, 13 infants were born to HBs Ag positive mother. All infants were given DNA recombinant vaccine at 0, 1, and 6 months of chronological age. Infants born to HBs Ag positive mothers received hepatitis B immunoglobulin at birth and a total of 4 doses of vaccinations. An antibody level over 10 mIU/mL, tested at 3-4 months after last vaccination, was regarded as a positive seroconversion. Results : The seroconversion rates were 84.4 percent and 84.5 percent for VLBWI and extremely low birth weight infants(ELBWI), respectively. Of 28 seronegative infants who were given revaccinations, 60.7 percent seroconverted, resulting in 95.3 percent, 97.5 percent seroconversion rates for VLBWI and ELBWI, respectively. 76.9 percent of infants born to HBsAg positive mothers seroconverted and none became hepatitis B carriers. Factors such as gestational age, sex, various neonatal illness, and kinds of vaccinations did not influence the formation of the hepatits B antibody, however, the higher the weight at time of first vacciation yielded better seroconversion rate. Conclusion : Revaccination of seronegative VLBWI after 3 doses of hepatitis B vaccinaton is very effective. Therefore, testing the immune status after the hepatitis B vaccination, a practice not routinely done, is highly recommended.

Measuring Water Content Characteristics by Using Frequency Domain Reflectometry Sensor in Coconut Coir Substrate (FDR(Frequency Domain Reflectometry)센서를 이용한 코코넛 코이어 배지내 수분특성 측정)

  • Park, Sung Tae;Jung, Geum Hyang;Yoo, Hyung Joo;Choi, Eun-Young;Choi, Ki-Young;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • This experiment has investigated suitable methods to improve precision water content monitoring of coconut coir substrates to control irrigation by frequency domain reflectometry(FDR) sensors. Specifically, water content changes and variations were observed at different sensing distances and positions from the irrigation dripper location, and different spaces between the FDR sensors with or without noise filters. Commercial coconut coir substrates containing different ratios of dust and chips(10:0, 7:3, 5:5, 3:7) were used. On the upper side and the side of the substrates, a FDR sensor was used at 5, 10, 20, 30cm distances respectively from the irrigation dripper point, and water content was measured by time after the irrigation. In the glass beads, sensors were installed with or without noise filtering. Closer sensing distance had a higher water content increasing rate, regardless of different coir substrate ratios. There were no differencies of water content increasing rates in 10:0 and 3:7 substrates between the upper side and the side. Whereas, 7:3 and 5:5 substrates showed higher increasing rates on the upper side measurements. Substrates with higher ratios of chip(3:7) had lower increasing rates than others. And, with noise filters, the exatitude of measurement was improved because the variation and deviation were reduced. Therefore, in coconut coir with FDR sensors, an efficient water content measurment to control irrigations can be achieved by installing sensors closer to an irrigation point and upper side of substrates with noise filters.

Artificial Mutation for Silkworm Molecular Breeding Using Gene Scissors (유전자 가위의 이용과 누에 분자 육종을 위한 인위적 돌연변이 유발)

  • Hong, Jeong Won;Jeong, Chan Young;Yu, Jeong Hee;Kim, Su-Bae;Kang, Sang Kuk;Kim, Seong-Wan;Kim, Nam-Suk;Kim, Kee Young;Park, Jong Woo
    • Journal of Life Science
    • /
    • v.30 no.8
    • /
    • pp.701-707
    • /
    • 2020
  • Gene editing technology using the clustered regularly interspaced short palindromic repeat (CRISPR) and the CRISPR associated protein (Cas)9 has been highly anticipated in developing breeding techniques. In this study, we discuss gene scissors as a tool for silkworm molecular breeding through analysis of Bombyx mori Kynurenine 3-Monooxygenase (BmKMO) gene editing using the CRISPR/Cas9 system and analysis of generational transmission through mutagenesis and selective crossing. The nucleotide sequence of the BmKMO gene was analyzed, and three guide RNAs (gRNAs) were prepared. Each synthesized gRNA was combined with Cas9 protein and then analyzed by T7 endonuclease I after introduction into the BM-N silkworm cell line. To edit the silkworm gene, K1P gRNA and Cas9 complexes were subsequently microinjected into the silkworm embryos; the hatching rate was 18% and the incidence of mutation was 60%. The gene mutation was verified in the heterozygous G0 generation, but no phenotypic change was observed. In homozygotes generated by self-crossing, a mutant phenotype was observed. These results suggest that silkworm molecular breeding using the CRISPR/Cas9 system is possible and could be an effective way of shortening the time required.

On the Determinants of Health Care Utilization of the Physically Disabled (지체장애인의 의료이용에 영향을 미치는 요인)

  • Kim, Keon-Yeop;Lee, Young-Sook;Park, Ki-Soo;Son, Jae-Hee;Kam, Sin;Chun, Byung-Yeol;Park, Jae-Yong;Yeh, Min-Hae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.2 s.61
    • /
    • pp.323-334
    • /
    • 1998
  • To investigate determinants of health care utilization of the physically disabled over 20 years old in age living in Taegu city, a self-administered questionnaire survey was carried out for 337 disabled persons with chronic illness from April to July, 1997. Health care utilization .ate was 81.9%(69.1% for hospital or clinic and 12.8% for pharmacy). Marital status, job, health concern, and response to illness showed statistically significant relationship with health care utilization(p<0.05). By path analysis, job, economic status, medical security type and response to illness had a significant direct effect on health care utilization(p<0.05), however, health concern and regular source of care had an indirect effect. The reasons of no health utilization were due to economic problem(31.1%), no symptom(18.0%), inconvenience to seek care or no accompanying persons to be helped(14.8%), unseriousness of the severity of the illness(14.8%), too busy to be treated or no free time(8.2%), hopeless prognosis to be treated(6.6%) in order. In conclusion, it is recommended that the program for expanding medicaid, improving socioeconomic status by getting a job and health education to increase the health concern toward physically disabled should be implemented to increase health care utilization rate.

  • PDF

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF