• Title/Summary/Keyword: Time Determination

Search Result 2,982, Processing Time 0.041 seconds

Determination of KITSAT-3 Orbital Elements Using GPS Data from a Low-End Receiver (저급 GPS 수신기 데이터를 이용한 우리별 3호의 궤도 요소 결정)

  • Lee, Eun-Sung;Lee, Young-Jae;Jee, Gyu-In;Park, Chan-Gook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.7
    • /
    • pp.123-129
    • /
    • 2002
  • This paper reveals determination of orbital elements of the satellite using GPS data collected by the low-end GPS receiver installed at KITSAT-3 which is a small scientific experimental satellite of Korea and launched in May 1999. An extended Kalman filter is designed for a forward estimation of real-time 3-dimensional position and velocity, and a smoother is used for a backward post-processing estimation of the same states. After finishing estimation of position and velocity, the corresponding orbital elements are estimated. Finally, the result of each orbital element is analyzed.

Evaluation of Analytical Method for Determination of Potassium in Tobacco Leaf (담배 엽 중 칼륨 분석법의 평가)

  • Cho Sung-Eel;Kim Mi-Ju;Kim Sang-Un;Kim Yong-Ha;Min Young-Keun
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.28 no.1
    • /
    • pp.51-57
    • /
    • 2006
  • This study was carried out to improve and evaluate the analytical method for determination of potassium in tobacco leaf by various pre-treatment techniques. The time requirment of various pre-treatments was about 10 hour for dry ashing and 6 hour for microwave digestion and 3 hour for sonication. The results of recover in both pre-treatment techniques, microwave digestion and sonication, is greater than 85 % stably with reproducibility(RSD %) on replicates of less than 3 %. However the mean values for microwave digestion were lower than certified standard value of NlST SRM. Compared to the other pre-treatment techniques, analytical results for sonication technique strictly improved the accuracy and precision. In conclusion, the use of the simple sonication technique seems to be efficient for the determination of potassium in tobacco leaf in consideration for both the accuracy and reproducibility.

Development of ELISA Method for the Determination of Compound K (Compound K 측정을 위한 ELISA법 개발)

  • Ryu, Mina;Li, Hai Guang;Sung, Jong Hwan;Sung, Chung Ki
    • Korean Journal of Pharmacognosy
    • /
    • v.46 no.4
    • /
    • pp.279-282
    • /
    • 2015
  • In order to quantify compound K(CK), anticancer component of Panax ginseng C. A. Meyer, high titer rabbit polyclonal antibodies (pAbs) were raised against a conjugate of CK and bovine serum albumin coupled by a periodate oxidation method. Coating antigen (CK-OVA) was also prepared by the same method with OVA. As a result of optimization of antiserum dilution (2,000 fold), coating antigen ($25{\mu}g/ml$) and other condition (incubation time, temperature and washing method), ELISA method for the determination of CK was established. The measuring range extended from 0.5 ng/ml to 25 ng/ml of CK. The antibodies exhibited minor or even no cross reactivities with protopanaxatriol (1.56%) and other tested ginsenosides, $GRb_1$ (0.11%), $GRg_1$ (0.07%) except protopanaxadiol (87.2%) from the structural similarity. And the antibody showed good correlation (r=0.987) between the assay values obtained by this ELISA method and HPLC. Therefore, the ELISA method could be very useful tools for the determination of CK in biological fluids because of their high sensitivity and specificity.

Mobility Determination of Thin Film a-Si:H and poly-Si

  • Jung, S.M.;Choi, Y.S.;Yi, J.S.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.483-490
    • /
    • 1997
  • Thin film Si has been used in sensors, radiation detectors, and solar cells. The carrier mobility of thin film Si influences the device behavior through its frequency response or time response. Since poly-Si shows the higher mobility value, a-Si:H films on Mo substrate were subjected to various crystallization treatments. Consequently, we need to find an appropriate method in mobility measurement before and after the anneal treatment. This paper investigates the carrier mobility improvement with anneal treatments and summarizes the mobility measurement methods of the a-Si:H and poly-Si film. Various techniques were investigated for the mobility determination such as Hall mobility, HS, TOF, SCLC, TFT, and TCO method. We learned that TFT and TCO method are suitable for the mobility determination of a-Si:H and poly-Si film. The measured mobility was improved by $2{\sim}3$ orders after high temperature anneal above $700^{\circ}C$ and grain boundary passivation using an RF plasma rehydrogenation.

  • PDF

Determination and Preconcentration of Copper(Ⅱ) after Adsorption of Its Cupferron Complex onto Benzophenone

  • Lee, Taik-Jin;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.6
    • /
    • pp.861-865
    • /
    • 2002
  • A sensitive method for the determination of trace copper(II) after the preconcentration by adsorbing its cupferron complex onto microcrystalline benzophenone was developed.Several experimental conditions such as the pH of sample solution,concentration of cupferron, amount of benzophenone and atirring time were optimized. Trace compper(II) in 100mL solution was chelated with $3.0\;{\times}\;10^3$ M cupferron at pH 5.0. After 0.20g benzophenone, The benzophenone adsorbing Cu-cupferron complex was filtered and then Cu-cupferron complex was desorbed in 10 mL ethanol. Copper was determined by a flame atomic absorption spectrophotomethry. The interfering effects of diverse concomitant ions were investigated. Fe(III) interfered seriously with, but the interference by Fe(III) was completely eliminated by adjusting the concentration of copferron to $5.0\;{\times}\;10^3$ M. The detection limit of this method was 8.6${\times}$10 M(5.5 ngmL$^1$). Recoveries of 97% and 96% were obtained for Cu(II) in a stream water and a brass sample, respectively. Based on the results from the experiment. this proposed technique could be applied to the determination of copper(II) in real samples.

Attitude Determination GPS/INS Integrated Navigation System with FDI Algorithm for a UAV

  • Oh Sang Heon;Hwang Dong-Hwan;Park Chansik;Lee Sang Jeong;Kim Se Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.8
    • /
    • pp.1529-1543
    • /
    • 2005
  • Recently an unmanned aerial vehicle (UAV) has been widely used for military and civil applications. The role of a navigation system in the UAV is to provide navigation data to the flight control computer (FCC) for guidance and control. Since performance of the FCC is highly reliant on the navigation data, a fault in the navigation system may lead to a disastrous failure of the whole UAV. Therefore, the navigation system should possess a fault detection and isolation (FDI) algorithm. This paper proposes an attitude determination GPS/INS integrated navigation system with an FDI algorithm for a UAV. Hardware for the proposed navigation system has been developed. The developed hardware comprises a commercial inertial measurement unit (IMU) and the integrated navigation package (INP) which includes an attitude determination GPS (ADGPS) receiver and a navigation computer unit (NCU). The navigation algorithm was implemented in a real-time operating system with a multi-tasking structure. To evaluate performance of the proposed navigation system, a flight test has been performed using a small aircraft. The test results show that the proposed navigation system can give accurate navigation results even in a high dynamic environment.

Determination of Total Phenolic Compounds from Korean Red Ginseng, and Their Extraction Conditions (고려홍삼의 총 페놀성환의 정량 및 그 추출조건)

  • 이종원;도재호;이성계;양재원
    • Journal of Ginseng Research
    • /
    • v.24 no.2
    • /
    • pp.64-67
    • /
    • 2000
  • This study was carried out to investigate the possible determination of total phenolic compounds by Folin-Denis method from Panax ginseng C.A. Meyer and their extraction conditions. It was possible to apply the method for determination of total phenolic compounds from Korean red ginseng. But 3 kinds of amino acids such as tyrosine, cystein and tryptophan, and 3 kinds of vitamins such as ascorbic acid, pyridoxin HCI and thiamine HCI affected strongly the colorization by the method. Effective alcoholic solvent for the extraction was 60% ethanol, appropriate extraction temperature, time and times were 40-80。C, 1-2 hours and 3 times, respectively.

  • PDF

Quantitative Determination of Doxifluridine and 5-FU in Monkey Serum Using LC/MS/MS (LC/MS/MS를 이용한 원숭이 혈액에서의 Doxifluridine과 대사체 5-FU 동시분석법 개발 및 Validation)

  • Woo, Young-Ah;Kim, Ghee-Hwan;Kim, Won;Lee, Jong-Hwa;Jeong, Eun-Ju;Kim, Jin-Ho;Park, Kui-Lea;Kim, Choong-Yong
    • YAKHAK HOEJI
    • /
    • v.51 no.3
    • /
    • pp.174-178
    • /
    • 2007
  • A reverse-phase high performance liquid chromatography method with electrospray ionization and detection by mass spectrometry is described for the simultaneous determination of doxifluridine and its active metabolite 5-flu-orouracil (5-FU) in monkey serum. The method has greater sensitivity and simpler process than previous published methods with good accuracy and precision. A proper liquid/liquid extraction was used to extract simultaneously doxifluridine and 5-FU which has considerable difference in the polarity. Extracts were analyzed using LC/MS/MS providing a short analysis time within 5 min. The lower limit of quantification was validated at 10.0 ng/ml of serum for both doxifluridine and 5-FU. Accuracy and precision of quality control (QC) samples for both analytes met FDA Guidance criteria of ±15% for average QC accuracy with coefficients of variation less than 15%. The method will be applicable for preclinical studies and bioequivalence studies.

Implementation of User Posture Correction Application using Kinect (키넥트를 이용한 사용자 자세 교정 어플리케이션 구현)

  • Kim, Hyeon-Woo;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.275-276
    • /
    • 2016
  • In this paper, we were implemented the application to induce correct posture by recognizing the incorrect posture of the user. Implemented system uses kinect sensors to determine the user's position information, it has been developed posture determination algorithm that can determine the four wrong posture and correct posture. In addition to PC in order to improve the user convenience and accessibility, to implement real-time monitoring application that can determine the user's position in the smartphone. For the system of performance evaluation of and promote the attitude determination experiment to target the five college students, the experimental results sensitivity and specificity of it it was found that the attitude determination performance is excellent at 0.956.

  • PDF

Polymeric Membrane and Solid Contact Electrodes Based on Schiff Base Complexes of Co(III) for Potentiometric Determination of Perchlorate Ions

  • Soleymanpour, Ahmad;Hanifi, Abdolghafoor;Kyanfar, Ali Hossein
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.9
    • /
    • pp.1774-1780
    • /
    • 2008
  • New PVC based polymeric membrane electrodes (PME) and coated glassy carbon electrodes (CGCE) based on synthesized Schiff base complexes of Co(III); [Co(Salen)$(PBu_3)_2$]$ClO_4$, [Co($Me_2$Salen)$(PBu_3)_2$]$ClO_4$, [Co(Salen)$(PBu_3)H_2O$]$ClO_4$; as anion carriers for potentiometric determination of $ClO_4\;^-$were studied. The PME and also CGCE electrodes prepared with [Co(Me2Salen)$(PBu_3)_2$]$ClO_4$ showed excellent response characteristics to perchlorate ions. The electrodes exhibited Nernstian responses to $ClO_4\;^-$ ions over a wide concentration range with low detection limits ($1.0 {\times} 10^{-6}\;mol\;L^{-1}$ for PME and $9.0 {\times} 10^{-7}\;mol\;L^{-1}$ for CGCE). The electrodes possess fast response time, satisfactory reproducibility, appropriate lifetime and, most importantly, good selectivity toward $ClO_4\;^-$ relative to a variety of other common inorganic anions. The potentiometric response of the electrodes is independent of the pH in the pH range 2.5-8.5. The proposed sensors were used in potentiometric determination of perchlorate ions in mineral water and urine samples. The interaction of the ionophore with perchlorate ions was shown by UV/Vis spectroscopy.