• Title/Summary/Keyword: Timber structure

Search Result 141, Processing Time 0.028 seconds

Basal Area-Stump Diameter Models for Tectona grandis Linn. F. Stands in Omo Forest Reserve, Nigeria

  • Chukwu, Onyekachi;Osho, Johnson S.A.
    • Journal of Forest and Environmental Science
    • /
    • v.34 no.2
    • /
    • pp.119-125
    • /
    • 2018
  • The tropical forests in developing countries are faced with the problem of illegal exploitation of trees. However, dearth of empirical means of expressing the dimensions, structure, quality and quantity of a removed tree has imped conviction of offenders. This study aimed at developing a model that can effectively estimate individual tree basal area (BA) from stump diameter (Ds) for Tectona grandis stands in Omo Forest Reserve, Nigeria, for timber valuation in case of illegal felling. Thirty-six $25m{\times}25m$ temporary sample plots (TSPs) were laid randomly in six age strata; 26, 23, 22, 16, 14, and 12 years specifically. BA, Ds and diameter at breast height were measured in all living T. grandis trees within the 36 TSPs. Least square method was used to convert the counted stumps into harvested stem cross-sectional areas. Six basal area models were fitted and evaluated. The BA-Ds relationship was best described by power model which gave least values of Root mean square error (0.0048), prediction error sum of squares (0.0325) and Akaike information criterion (-15391) with a high adjusted coefficient of determination (0.921). This study revealed that basal area estimation was realistic even when the only information available was stump diameter. The power model was validated using independent data obtained from additional plots and was found to be appropriate for estimating the basal area of Tectona grandis stands in Omo Forest Reserve, Nigeria.

The Ancient Construction Materials and Methods: The Great Wall of China in Jinshanling as a Case Study

  • Yang, Jin;Tan, Fabian Hadipriono;Tan, Adrian
    • Journal of Construction Engineering and Project Management
    • /
    • v.7 no.1
    • /
    • pp.37-49
    • /
    • 2017
  • The Jinshanling section of the Great Wall of China is a series of fortifications in northern China that was constructed for strategic military defenses. This section was first built in the beginning of the Ming Dynasty in AD 1368 and then underwent major construction, reconstruction and renovation during the late Ming Dynasty, approximately in AD 1569. The Jinshanling section is 10.5 km long, a very short section compared with the entire 21,200 km wall. The wall section is located in Luanping County, Hebei province, China. This research paper focuses on the construction methods and materials of the wall and the towers in the area. The research methodology includes site visits, knowledge acquisition of experts and 3D graphic modeling. This study reveals that the materials selected for the structure include rubbles and rammed earth, bricks, stones, timber, and mortar. The erection sequence of the wall and the towers was a bottom-up fashion using various ancient construction techniques, such as the fire-setting rock blasting techniques and the surveying techniques from the Sea Island Mathematical Manual.

Craftsmanship of Non-Educated Constructors in Korean-Style Secondary Station(Gong-So) of Naepo Region (충남 내포지방의 한옥 공소에 나타난 민간 기술자의 현장기법)

  • Park, Kwang-Hyun;Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.3
    • /
    • pp.19-26
    • /
    • 2010
  • This study is aimed to look into the craftsmanship non-educated constructors in Korean-style secondary stations(Gong-So) of Naepo region which is located in the northwestern Chungcheongnam-do. Although the area was persecuted as one of three cradles of Korean Catholicism, Catholic activities flourished there. The 13 cases of Korean-style secondary stations were selected through a survey report list about modern cultural assets of Chungcheongnam-do published in december 2004. This study examined the methods of plan layout and framework of Gong-So to look into craftsmanship of non-educated constructors, the results are as follows; The methods of plan layout are divided into three types according to existence and arrangement of inner column(Nae-Ju); 'Layout with Nae-Ju' is considered as the primary form of Korean-style Gong-So with using regular Nae-Ju. 'Layout with the different position of the center between Nae-Ju and exterior column(Oe-Ju)' and 'layout without Nae-Ju' is appeared in Korean-style Gong-So which is important to assembly and alter function. The methods of framework are appeared variously according to different plan layout for securing worship space. The unusal beam(Chung-Ryang) is used to solve different spans of altar and narthex. When space was formed widely without Nae-Ju, diagonal members and M letter type rafters are used, they are influenced by the technique of western wooden roof truss.

A Study on the Applicability of Bearing Capacity Formulas of Driven Pile by Comparison with the Results of Static Loading Tests (정재하시험 결과를 통한 타입말뚝 지지력 공식의 타당성 분석)

  • Chun, Byung-Sik;Lee, Seung-Beom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.544-551
    • /
    • 2004
  • Piles are structural elements made of steel, concrete or timber, and utilize as pile foundation which is one of deep foundations. Driven pile among them, which drives pile into the ground, is fast-constructable, less expensive and it supplies much bearing capacity. For these reasons, its demand is steady. In this study, by selecting the cases which reached ultimate failure during in-situ static loading tests, bearing capacities acquired from these tests were compared with those computed by existing theories and formula. As the results of the analysis, ultimate bearing capacity computed by theoretic formula were less or similar to those of test results in most cases, but lower ground water level and more dense layer where end of piles were reached remarkably high bearing capacity in theoretical methods. ${\beta}-method$ and Korean structure foundation design standard were sensitive to ground physical properties. Meyerhof metbod and API code were relatively independent from site condition.

  • PDF

A Study on Laminated Furniture for Organic Form and Utility of Fullscale Model (합판 적층재 가구의 유기적 조형을 위한 실물대 모델의 효율성 연구)

  • Kim, Ji-Geon
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.5
    • /
    • pp.319-327
    • /
    • 2008
  • As art of lamination by plywood got to be generally used, it became a suitable material for expressing live curves that were not able to be expressed on wood furniture made of plank and timber, as well as, openwork deep in curved space, heavy quality of material, and changing contour line-looking wave lines with different process angles. As an alternative, it would be good to build a full scale model, since it would provide practice in form-building and it would also provide a chance to correct the form. Less material can be used and reduce the cutting process by Properly trimming models made of soft formal structure such as Styrofoam Iso-pink and adhesive Styrofoam, and separating the layers and using them on shape cutting of plywood with the same thickness. And by attaching the model veneer that was used in shape cutting of the model and using it as a cutting guide, we can reduce the error of work and successively build the planned form. Since this study is about the need of a full scale model for a laminated wood model and an efficient process, this study concentrates more on process.

  • PDF

Characteristics of the Use of the Western Building System with the Change of the Architectural Design in the Japanese Colonial Period - Focused on the Facility Built by Japanese Government-General in 1910s - (일제강점기 양식건축구법(洋式建築構法) 사용의 특징과 계획적 변화 - 1910년대 조선총독부 관립시설을 중심으로 -)

  • Joo, Sang-Hun
    • Journal of architectural history
    • /
    • v.21 no.5
    • /
    • pp.57-68
    • /
    • 2012
  • The purpose of this study is to identify the characteristics of the use of the western building system with the change of the architectural design in the Japanese colonial period focused on the facility built by Joseon Government-General in 1910s. Through the 131 cases of governmental building, the tendency of the use of western building system. After 1910, Japanese Imperialism adopted the western wooden building system which main structure was made with combination of small pieces of timber for building the modern governmental facility because of the political and financial intention. So, all facilities were designed similarly by the structural module and the facade was finished by the feather boarding in the same with the 'sitamitakei-giyohu' in Japan. the functional requirements of each facility was not revealed. Such an western wooden building system was used until 1920s with the change of the facade by the mortar coating. But, in 1920s-1930s, the building system have begun to change. The use of the brick system caused some changes although the planing concept was still lasted. On the other hand, the use of the reinforced concrete led to more changes on the overall scheme.

A Study on the Application of an Environment Friendly Crossing Wood Drain for Easy Forest Road Management (산림관리도로의 생력화를 위한 친환경적 횡단목 배수로의 적용에 관한 연구)

  • Lee Sung-Gie;Lee Kab-Yeon;Kim Jong-Han;Kang Young-Je;Byun Kwang-Ok
    • Journal of Environmental Science International
    • /
    • v.14 no.6
    • /
    • pp.521-524
    • /
    • 2005
  • We introduce a simplified crossing wood drain disperses rain water concentration and is used to protect the road surface from erosion due to flooding over the unpaved road. The efficiency of a simplified crossing wood drain was also investigated. A structure of simplified crossing wood drain can be produced within 10 minutes and installed within 18 minutes. The cost of the this product is 1/5 of that of the existing crossing drain product. The production and installation cost can be reduced according to dexterity. In the context of such applications, the degrees of damage for a rubber pad, which preventing the rain overflow, were varied according to their materials. A type of 8.2mm thick fabric rubber was the most suitable in this study.

A Study on The Chinese Traditional Wood-joints Applied to Furniture Design of Shelf - Focusing on One-room - (중국의 전통가구에 나타난 짜임기법이 적용된 원룸용 모듈형 가구디자인 개발)

  • Qin, Lu;Kim, Chung Ho
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.2
    • /
    • pp.95-102
    • /
    • 2017
  • In the process of changing from modern society to contemporary society, innovation of various fields is considered as important with rapid social change and one of the consequences of this changing movement is the innovation of living space. In this paper, based on this motive, we will study a modular shelf that can create a private space, and serve function like role of partition that delimits space in the one-room. Modular shelves can provide openness, closeness, and autonomy to individual spaces in a one-room space without space divisions. In a small one-room for residential purpose, it is able to function effectively to show the atmosphere of personal space and display small items reflecting personal taste in addition to the function of storing books and items. In addition, a modular shelves considering disassembly and movement are proposed in order to take advantage of one-room that can make different space configurations as needed. It is aim to suggest a basic modular shelves structure that used traditional Chinese wood-joints during which techniques was sturdy while reducing the use of timber. Futhermore, the purpose of this study is to study the design of shelf furniture that can add individuality.

Termite Resistance of Impregnated Jabon Wood (Anthocephalus Cadamba Miq.) with Combined Impregnant Agents

  • Arsyad, Wa Ode Muliastuty;Basri, Efrida;Hendra, Djeni;Trisatya, Deazy Rachmi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.451-458
    • /
    • 2019
  • Jabon (Anthocephalus cadamba Miq.) is a fast-growing species that exhibits a lower natural resistance than that exhibited by the timber sourced from natural forests. Jabon's resistance to termite attack can be improved by impregnating its wood structure with poisonous organic materials. This study examined jabon's resistance to termite attack when impregnated with wood vinegar and an animal adhesive. The wood specimens were impregnated using sengon wood vinegar and an animal adhesive (8% and 10%, respectively) using a vacuum pressure machine. The specimens were tested for their resistance to subterranean and dry-wood termites according to Indonesian National Standard (SNI 7207-2014). The results denoted that jabon impregnated with wood vinegar and an animal adhesive concentration of at least 8% with the addition of 4% borate was effective to resist termite attacks. The impregnated jabon exhibited a lower weight loss and higher termite mortality when compared with those exhibited by the control specimens. Thus, the resistance class improved from class IV to class I.

Load Bearing Capacity of CLT - Concrete Connections with Inclined Screws (경사못이 적용된 CLT-콘크리트 접합부의 하중전달능력)

  • Kim, Kyung-Tae;Kim, Jong-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.3-13
    • /
    • 2018
  • Load bearing capacity of dowel type fasteners loaded perpendicular to the shear plane is determined based on Johansen's yield theory (Johansen, 1949). In case of inclined screws whose axis is no longer perpendicular, the ultimate load of connection increases because of additional axial withdrawal capacity. To calculate load bearing capacity for inclined screws, KBC2016 and Eurocode5 provide design equations using the combination of two effects; axial and bending strength. Although their equations have been validated for a long time, there is still minimal information how to apply them for concrete-CLT joints. Since there are not many test data available, engineers have to make certain assumptions and thus results may look inconsistent in practice. In this paper, authors would like to describe the current approach and assumptions indicated by KBC2016 and Eurocode 5 and how they match the experimental results in terms of shear strength of CLT-concrete connections. To fulfill the objective, several push-out tests were performed on nine different test specimens. Each specimen has different penetration angles and depths. By analyzing load-displacement curves, the maximum shear strength, stiffness, and ductility were obtained. Shear strength values were compared with the current design codes and theoretical equations proposed in this paper. Observations on stiffness and ductility were briefly discussed.