• Title/Summary/Keyword: Tilting motor

Search Result 47, Processing Time 0.036 seconds

Example Development of Medical Equipment Applying Power Electronics Technique (전력전자 기술을 응용한 의료장비 개발 사례)

  • 고종선;이태훈;김영일;김규겸;박병림
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.6
    • /
    • pp.524-530
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement and skeletal muscle contract. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for- stimulation with horizontal, vortical and 3D patterns. The Off-vortical axis rotator is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

The Experimental Study for the Balanced Restoration on the part of Spinal Skeletal Muscles in Low Back Pain Patients - By Acupuncture Stimuli Model of Limb Skeletal Muscle - (요통환자의 척주골격근 균형회복을 위한 실증적 연구 - 사지골격근의 침 자극모형을 중심으로 -)

  • Moon, Sang-Eun;Lee, Cheon-Bok
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.907-915
    • /
    • 2001
  • The purpose of this study is to effectively treat low back pain for the out patients who have been treated at the oriental hospital. Sorting the low back pain patients into four types based on scapular and ilium tilting hyper/hypo mobility characteristics, it has used several kinds of acupuncture stimuli on the 4 motor points of limb skeletal muscles, analyzing the acupuncture treatment on the 12 acupuncture points with which oriental hospitals has given to the low back pain patients and comparing with this effect. It has been analyzed how effectively the acupuncture stimuli has been contributed to the low back pain patients who suffered from skeletal muscles of spinal limb thorax abdominal and spinal skeletal system. The results are as follows. 1. There has been changes after treatment in both the control and experimental groups for low back pain patients, but the latter has been more increased in changes than the former. 2. There were much effects on the balanced restorations for spinal skeletal muscle in both the control group and experimental one, but on terms of restoration degree, the degree of the experimental group was higher than that of the control group. 3. Both the contrastive treatment and the experimental one have been contributed to the balanced restoration for all of the limb thorax abdominal muscles, but there were a few differences in terms of the way for restoration and the effects for improvement according to body types. 4. On both the control and the experimental group, spinal skeletal system has been restored with balance, but the experimental group has been higher effective on the balanced restoration than the one of the control group. Considering these results both the control and the experimental treatments have been contributed to the balanced restorations for all of low back pain patients who were suffering from skeletal muscles of spinal limb thorax abdominal and spinal skeletal system, but the contribution degree for the experimental group has been higher than that of the control group.

  • PDF

Example Development of Medical equipment applying Power Electronics Technique (전력전자 기술을 응용한 의료장비 개발 사례)

  • Ko Jongsun;Lee Taehoon;Kim Yongil;Kim Gyugyeom;Park Byungrim;Kim Minsun
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.661-664
    • /
    • 2002
  • A control of the body posture and movement is maintained by the vestibular system, vision, and proprioceptors. Afferent signals from those receptors are transmitted to the vestibular nuclear complex, and the efferent signals from the vestibular nuclear complex control the eye movement. The postural disturbance caused by loss of the vestibular function results in nausea, vomiting, vertigo and loss of craving for life. The purpose of this study is to develop a off-vertical rotatory system for evaluating the function of semicircular canals and otolith organs, selectively, and visual stimulation system for stimulation with horizontal, vertical and 3D patterns. The Off-vertical axis rotator which stimulates semicircular canals and otolith organs selectively is composed of a comportable chair, a DC servo-motor with reducer and a tilting table controlled by PMSM. And a double feedback loop system containing a velocity feedback loop and a position feedback loop is applied to the servo controlled rotatory chair system. Horizontal, vertical, and 3D patterns of the visual stimulation for applying head mounted display are developed. And wireless portable systems for optokinetic stimulation and recording system of the eye movement is also constructed. The Gain, phase, and symmetry is obtained from analysis of the eye movement induced by vestibular and visual stimulation. Detailed data were described.

  • PDF

Design of Embedded Electrical Power Control Unit for Personal Electrical Vehicle (1인승 전기차량의 임베디드 전동제어장치 설계)

  • Shin, Kyoo-Jae;Cha, Hyun-Rok
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.282-290
    • /
    • 2014
  • This paper presents the design of embedded electrical power control unit for Personal Electrical Vehicle(PEV). The embedded unit is designed using PIC18F8720 processor, 16Mb flash ROM, 32Mb SDRAM and signal condition circuits. The proposed PEV consists of 4KW in-wheel Brushless DC Motor(BLDCM), 3 phase voltage source inverter with the $180^{\circ}$ conduction space vector PWM method, PID speed controller and the embedded control unit. The PEV has mechanical manufacture of inverse 3 wheel system, which is applied by the in-wheel BLDCM and steering mechanism with tilting function. Also, the performances of the proposed embedded electrical power control unit are verified through the lab experiment and road driving test of PEV.

First Remote Operation of the High Voltage Electron Microscope Newly Installed in KBSI (초고전압 투과전자현미경의 원격시범운영)

  • Kim, Young-Min;Kim, Jin-Gyu;Kim, Youn-Joong;Hur, Man-Hoi;Kwon, Kyung-Hoon
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.13-21
    • /
    • 2004
  • The high voltage electron microscope (HVEM) newly installed in KBSI is an advanced transmission electron microscope capable of atomic resolution (${\leq}1.2{\AA}$ point-to-point resolution) together with high titling function (${\pm}60^{\circ}$), which are suitable to do 3-dimensional atomic imaging of a specimen. In addition, the instrument can be controlled by remote operation system, named as 'FasTEM' for the HVEM, which is favorable to overcome some environmental obstacles resulting from the direct operation. The FasTEM remote operation system has been established between the headquarter of KBSI in Daejeon and the Seoul branch. The server system in the headquarter has been connected with a portable client console system in the Seoul branch using an advanced internet resource, 'KOREN' of 155 Mbps grade. Most of the HVEM functions essential to do remote operation are available on the portable client console. The experiment to acquire the high resolution image of [001] Au has been achieved by excellent transmission of control signals and communication with the HVEM. Real-time reaction like direct operation, such as controls of the illumination and projection parameters, acquisition and adjustment of each detector signal, and electrical steering of each motor-driven system has been realized in remote site. It is positively anticipated that the first remote operation of HVEM in conjunction with IT infraengineering plays a important role in constructing the network based e-Science Grid in Korea for national user s facilities.

Study on Design of Advanced Smart Postural Change Device for Supine Posture Control (와상체위제어를 위한 스마트 고기능 자세변환기의 설계에 관한 연구)

  • Park, Seung Hwan;Jung, Jin Taek;Sim, Woo Jung;Kim, Yung Sear
    • 재활복지
    • /
    • v.18 no.4
    • /
    • pp.221-235
    • /
    • 2014
  • Recently, the frequency of stroke disease is increased due to the rapid aging population, and is contributed to the major occurrence factors of the posteriori acquired disability. This study is about an postural change device for the control of supine posture which is an assisted equipment using in daily rehabilitation process for overcoming the disability by the aftereffects of the stoke disease. In this paper, the existing domestic and Japan postural appliances is examined and its comparison and categorization is performed according to its functions and purposes. Here, in order to control the supine posture state, the design method for advanced multi functional system is proposed, which is devised to have an unified mattress control operations of combining the bedsore prevention tube with the supine posture tilting tube. And also, in addition of an smart function, it is designed to enable to perform an RF functions such as the monitoring of the present device state, the alteration of the basic position and the control of alternative floating and supine posture. This system control hardware consists of three main parts : the sensor detection part, the motor driving /control part, and the system control part for bluetooth communication. In results, we confirmed that the system designed by this research is possible to make it practical as an advanced smart postural change device combined by IoT technology in the application field of the recent IT technology.

Development and Tree-Dimensional Kinematic Analysis of the Dual Chamber-based Drinking Aid for Stroke Patients: A Prospective Pilot Study (이중 체임버 구조가 내장된 뇌졸중 환자용 컵의 개발과 3차원 동작분석을 통한 운동 형상학적 유용성 검증: 전향적 예비연구)

  • Heo, Seo Yoon;Kim, Kyeong-Mi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.180-190
    • /
    • 2016
  • This prospective pilot clinical trial mainly focuses on developing dual chamber-based assistive cups which are suitable for stroke patients who have struggled with using there affected arms. It is unable to provide motor and sensory enhancement during drinking activities and to examine the feasibility of the devices for acute phase, even for chronic stroke survivors. The stroke patients(n=16; male=8, female=8), in this trial, were provided informed consent to the investigation. All the individuals participated in 1 weeks of training for using cups, randomized over dedicated dual chamber based assistive cups(DC) or placebo-cups(PC) training. All the participants were assessed within 1 week before and after the intervention period. 3-dimensional motion analysis, sEMG(surface electromyography) and 3-dimensional trunk movement were assessed. The result presents DC data group compared with PC showed, they needed lesser ROM(range of motion) at the phase of drinking in shoulder movements and lesser muscle activities on upper trapezius, deltoid middle fiber and triceps brachii muscles, lesser tilting movement on front and back side in drinking phase, the differences were statistically significant(p<.05). Dual chamber-based assistive cup could be one of efficient way to complete ADLs(activities of daily living), especially drinking tasks, and these evidence data may contribute to determine certain rehabilitation policies related to assistive devise usage.