• 제목/요약/키워드: Tightness evaluation

검색결과 59건 처리시간 0.028초

Evaluation of the Impacts of Stack Effect in High-Rise Buildings

  • Yang, In-Ho;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.91-103
    • /
    • 2003
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impacts on the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal air flow resistance. Therefore the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

현장실험을 통한 공동주택의 실내공기환경 평가 (A Evaluation Study on Indoor Air Quality of the Apartment House through Field Measurement)

  • 박용승;배상환;유복희;홍천화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2003년도 정기총회 및 추계학술대회
    • /
    • pp.83-87
    • /
    • 2003
  • In recent days, IAQ(Indoor Air Quality) is regarded as one of the most important environmental factors as well as thermal and acoustic comfort. Various architectural materials are applied and air-tightness of the building is more strengthening to save energy consumption. This is why the air quality of the newly built houses became worse. In this study, contaminants(CO, CO$_2$, Radon, TVOCs, HCHO) density was measured in a newly built house and evaluation was carried out by ASHRAE and EPA Standards. As a result, CO, CO$_2$, TSP and Radon density of the newly built house was in a range of ASHRAE and EPA Standards, but it turned out TVOCs and HCHO density exceeds almost 3${\sim}$5 times in comparison with that of ASHRAE and EPA Standards.

  • PDF

都市 超高層 住居建築의 室內空氣環境의 評價에 관한 硏究 (A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House)

  • 박미진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.119-125
    • /
    • 2002
  • The concept of dwelling space is tend to be changed not only to have reasonable mobility but also to have high quality of indoor air with psychologicaa satisfaction and comfortable. Moreover, recent constructed buildings have a big problem because of exhausted pollution gas and particles from building materials. More serious problem occurs from its high air tightness reducing the ventilation for saving the energy and superior adiabatic insulators to have high heat efficiency. Indoor air quality in super high-rise dwelling house was investigated by measuring pollutants such as $CO_2,=;CO,\;MO_2,\;R_n,\;TSP,\;PM_{10}$, HCHO, Offensive ordor. Subjective evaluation of residential environment is processed for the inhabitants who live in research space by testing environmental load in accordance with environment morphology, exterior environmental factor and post occupancy correlation and influence of attention.

LNG선박용 내조시스템 소재의 기계적 특성 및 피로강도 평가 (Evaluation of the Fatigue Strength and the Mechanical Properties for Cargo Containment System in LNG Ship)

  • 심희진;김민태;윤인수;김영균;김정규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1-6
    • /
    • 2007
  • The membrane type LNG(Liquefied Natural Gas) cargo containment system is a special design structure for the large deformation behavior at LNG temperature$(-162^{\circ}C)$. The design of membrane is required great confidence so that membrane can plat role in the tightness of flammable fluid storing. LNG cargo containment is loaded and unloaded LNG between twice and five times in a week. During this process, the membrane has large deformation behavior due to the variation of temperature and pressure to the self weight. In this study, the evaluation of the fatigue strength of membrane is very important to determine the design life of LNG storage tank and to evaluate the mechanical properties at the LNG temperature. Also, in the view point of large deformation, the evaluation method is applied conservatively $\epsilon-N_f$ curve of SUS 304L.

  • PDF

멤브레인 복합 방수재의 현장품질 안정성 확보를 위한 시공성 실증 평가 연구 (Constructional Verification Evaluation for Securing the Field Quality of Composite Membrane Waterproofing Material)

  • 김명지;이상욱;김수연;오상근
    • 한국건축시공학회지
    • /
    • 제21권1호
    • /
    • pp.87-95
    • /
    • 2021
  • 본 연구에서는 현재 건설신기술로 지정된 복합계방수공법 7개사(A~G)를 대상으로 KS F 2622:멤브레인 방수층 성능평가 시험방법 중 현장 적용조건과 유사성이 큰 평가항목을 선정하여 평가한 결과, 모든 시험체가 기본 물성평가에서 KS 기준을 상회하는 성능을 확보했음에도 불구하고, 내피로(균열 거동) 시험을 제외한 방수성(수밀성) 시험, 처짐 저항성 시험, 부풂 저항성 시험에서 점착 도막 계열로 이루어진 공법의 접합부와 수직부 등 취약부위의 현장품질 성능을 확보하기 어려운 것으로 확인하였다.

EVALUATION OF TIGHTNESS OF PROXIMAL TOOTH CONTACT IN PERMANENT DENTITION

  • Kim, Kyoung-Hwa;Jung, Jae-Hyun;Kim, Hee-Jung;Chung, Chae-Heon;Oh, Sang-Ho
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.553-560
    • /
    • 2008
  • STATEMENT OF PROBLEM: Proximal contact plays an important role in the stability and maintenance of the integrity of the dental arches. However, it is difficult to evaluate quantitatively the tightness of proximal tooth contact (TPTC). PURPOSE: The aim of this study was to measure the TPTC in permanent dentition. MATERIAL AND METHODS: Ten young adult volunteers with healthy dentition participated in this experiment. The TPTC between the teeth of both the maxilla and the mandible was measured at rest state by a novel device which records the TPTC by pulling of a stainless steel strip (0.03 mm thick) using the electric motor. One-way ANOVA test was used to compare the values in all measured area. When a statistically significant difference was calculated, Bonferroni correction was applied. Independent samples t-test was used to compare the values in male and female. RESULTS: The lowest TPTC and the highest TPTC was measured between the lower central incisors (0.87 ${\pm}$ 0.20 N), and between the lower left first molar and second molar (1.99 ${\pm}$ 0.68 N), respectively. All TPTC per quadrant demonstrated a similar pattern of a continuous increased gradient in an anterior-posterior direction. There are no significant difference between the maxilla and mandible. CONCLUSION: The TPTC was measured quantitatively by a novel device and decreased progressively in a posterior-anterior direction.

폐암의 임상적 고찰 (Clinical Evaluation of the Lung Cancer)

  • 최순호
    • Journal of Chest Surgery
    • /
    • 제11권1호
    • /
    • pp.26-34
    • /
    • 1978
  • We observed 82 cases of primary lung cancer clinically and statistically, which had been experienced at the dept. of thoracic surgery, Chonnam University Hospital, during the period of 13 years from 1964 to 1967. The results obtained were as follows: Peak incidence of age was from 5th decade to 6th decade, and the ratio of male to female was 3: 1. The frequency of lung cancer was higher in the heavy smoker than in the lighter smoker, and undifferentiated carcinoma showed low resectability in spite of the shorter clinical duration. Major symptoms were coughing and chest tightness & pain, especially coughing was initial symptom in the majority of patients. Of the 82 cases, operation was performed in the 32 cases [39%], but resection was possible in the 22 cases [27%]. The delaying factors led patients to an inoperable stage were physician’s misdiagnosis of bronchogenic carcinoma due to non-specific symptoms and signs of the patients, old age patients were dependence on herb medicine, and poor economical condition of the patients in our region especially. Basic conditions of treatment in lung cancer were early detection & early surgery, so, chest P-A would be checked per 3 to 6 months interval associated with sputum cytology in the smoker over 45 age routinely.

  • PDF

근육 불균형에 관한 연구 (A Study of Muscular Imbalance)

  • 배성수;김병조
    • The Journal of Korean Physical Therapy
    • /
    • 제13권3호
    • /
    • pp.821-828
    • /
    • 2001
  • Muscle imbalance describes the situation in which some muscles become inhibited and weak, which others become tight, losing their extensibility. Muscle imbalance develops mainly between tightness and inhibition. Although muscle imbalance involves the whole body, the imbalance is more evident or starts to develop gradually and predictably in the pelvic region, where we speak about the pelvic or distal crossed syndrome, and the shoulder girdle. neck region, associated with a proximal or shoulder girdle crossed syndrome. Evaluation of muscle imbalance in a patient can be from location of the line of gravity in relation to the trunk.

  • PDF

내적 충돌 증후군 (Internal Impingement of the Shoulder)

  • 김양수
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2007년도 제5차 연수강좌
    • /
    • pp.153-161
    • /
    • 2007
  • 견관절의 ABER position에서 posterosuperior rotator cuff 가 posterior glenoid에 contact 하여 internal impingement가 일어나는 현상은 운동선수가 아닌 일반인에게도 발생하는 physiologic phenomenon이며 과도한 반복 동작으로 인하여 증상이 발현한다. Internal impingement는 증상이 모호할 뿐만 아니라 견관절 내 여러 병소가 함께 존재하기 때문에 각각의 pathology에 대한 자세하고 정확한 evaluation이 필수적이다. 아직 controversy가 있지만 internal impingement의 pathologic factors로서는 anterior capsular laxity (true anterior laxity), posteroinferior capsular tightness (pseudo anterior laxity)와 이로 인한 glenohumeral internal rotation deficit (GIRD), 그리고 SICK scapula syndrome (scapular dyskinesis) 등으로 요약할 수 있다. 진단은 주로 병력 청취와 신체 검사로 내려지며 ultrasonogram, MRA등으로 확진한다. Sleeper stretching exercise 등과 같은 보존적 치료에 반응이 좋지만 6개월간의 재활 치료에도 호전이 없다면 증상과 직접 관련된 주 병소(appropriate pathology)를 찾아 이에 대한 적절한 수술이 이루어져야 한다.

  • PDF

고층건물에서의 연돌효과 시뮬레이션 (Simulation of the Stack Effect in High-Rise Builbings)

  • 양인호;여명석;조재훈;김광우
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.456-467
    • /
    • 2002
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impact of the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal airflow resistance, so the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.