• 제목/요약/키워드: Tightening torque

검색결과 92건 처리시간 0.024초

수종의 임플랜트 시스템의 나사풀림에 관한 연구 (Screw Loosening of Various Implant Systems)

  • 안진수;조인호;임주환;임헌송
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.81-91
    • /
    • 2002
  • Dental implant systems have shown many post-surgical problems and One of the most frequent problem is screw loosening. To reduce screw loosening, a number of methods have been tried and recently fundamental modification of fixture-abutment connection structure was developed and used the most frequently. Former implant system structure, such as Br${\aa}$nemark, had external hex with the height of 0.7 mm and later, fixture with external hex of 1.0 mm height and internal hex structure were developed. In addition, the method of morse taper application was introduced to reduce screw loosening. In this study, the level of screw loosening of each implant systems was compared based on the vibration loosening measurement of abutment screw of each implant systems. Analysis of measured value was performed using 3 kinds of methods, (i) Percentage of average of initial 3 times loosening-torque value(initial loosening value) to tightening-torque of 30 Ncm, (ii) Percentage of loosening-torque value after 200 N strength loaded(experimental value) to initial loosening value and (iii) Percentage of experimental value to 30 Ncm of tightening-torque. Each result of analyses shows the value of initial loosening, loosening by repetitive load and final loosening level. The results of this study were as follows. (1) Percentage of initial loosening value to tightening-torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of internal hex, 0.7 mm external hex, 1.0 mm external hex and internal taper. Value of internal taper showed significant difference with that of 0.7 mm external hex and internal hex (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper. Values of all groups showed statistical significance (p<0.05) except between the groups of 1.0 mm external hex and internal hex. Based on those results, there was no significant difference of loosening-torque by repetitive loading except internal taper. It is supposed that implant system with high resistant capability against initial loosening could be recommended for clinical use. In addition, in case of single implant restoration, 1.0 mm external hex or internal hex could be recommended rather than 0.7 mm external hex, and the use of internal taper would be the most useful way to reduce screw loosening.

내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구 (Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study)

  • 이상운;차민상;이지혜;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.95-103
    • /
    • 2020
  • 목적: 본 연구의 목적은 내부연결 원추형 임플란트의 육각구조 유무가 임플란트 지대주 장축변위와 임플란트 지대주 나사의 풀림토크에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 내부연결 원추형 임플란트를 육각구조를 가진 지대주 그룹(HEX)과 육각구조를 갖지 않는 지대주 그룹(CON)으로 나누고 각 그룹 당 10쌍의 시편을 체결하였다. 지대주 나사를 30 Ncm 조임회전력을 가하여 체결한 뒤 장축변위 및 풀림토크값을 측정하고 250 N 수직적 반복하중을 100,000회 가한 뒤 장축변위 및 풀림토크값을 측정하였다. 각 단계마다 디지털 마이크로미터를 이용하여 임플란트 직경과 수직적 높이를 측정하였고 전자 토크게이지를 이용하여 풀림토크값을 측정하였다. 각 군간의 값의 유의차를 확인하기 위하여 독립 표본 T 검정을 이용하여 통계분석하였다(α = 0.05). 결과: HEX 군은 조임회전력을 가한 뒤 유의하게 높은 장축변위를 나타내였다(P < 0.05). HEX 군과 CON 군은 수직적 반복하중 후 장축변위에 유의한 차이를 보이지 않았다(P = 0.052). HEX 군과 CON 군은 수직적 반복하중 전, 후 풀림토크값 모두 유의한 차이를 보이지 않았다(P = 0.057 and P = 0.138). 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다(P < 0.05). 결론: 내부연결 원추형 임플란트에서 육각구조를 가진 경우 장축 변위가 더 컸으며, 그 외의 연결부 안정성은 유사하였다. 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중 및 조임회전각에 미치는 영향 (Influence of Tungsten Carbide/Carbon Coating on the Preload and Tightening Torque of Implant Abutment Screws)

  • 신현모;조욱;정창모
    • 구강회복응용과학지
    • /
    • 제25권1호
    • /
    • pp.53-59
    • /
    • 2009
  • 본 연구는 external butt joint 연결 형태를 가진 임플랜트 시스템에서 티타늄 합금 나사와 텅스텐 카바이드와 탄소로 코팅한 나사의 압축력 및 조임 회전각 측정을 통해 동일한 전하중을 얻는 데 있어 코팅나사 사용이 갖는 임상적 효율성을 간접적으로 비교해 보고자 하였다. 본 연구에서는 Osstem Implant의 US II 시스템 고정체(${\phi}=4mm$)와 Cemented abutment를 사용하여 티타늄 합금(Ta) 지대주 나사 및 텅스텐 카바이드와 탄소로 표면 처리한(WC/CTa) 지대주 나사에 30Ncm의 조임 회전력을 적용한 후 압축력 및 조임 회전각을 측정하였다. 다음 WC/CTa 지대주 나사에서 측정된 압축력의 평균값을 계산하고 이를 Ta 지대주 나사에 적용하여 동일한 압축력이 가해질 때의 조임 회전력 값을 측정하였다. 그리고 실험결과 측정된 조임 회전력의 평균값을 Ta 나사에 적용한 후 조임 회전각을 측정하여 비교해 본 결과 다음과 같은 결론을 얻었다. 30Ncm의 조임 회전력에서 텅스텐 카바이드/탄소 코팅 나사가 티타늄 합금 나사보다 압축력과 회전각이 더 높게 나타났다. 텅스텐 카바이드/탄소 코팅 나사에 30Ncm의 조임 회전력을 적용하여 발생한 압축력을 얻기 위해서는 티타늄 합금 나사의 경우 55.6Ncm의 조임 회전력이 필요하였으며, 회전각에는 두 나사 간에 차이가 없었다.

고력볼트 시공환경에 따른 토크계수와 체결축력에 관한 실험적 연구 (Experimental Study on the Torque Coefficient and Clamping Force of High Strength Bolts Subjected to Environmental Parameters)

  • 이현주;나환선;김강석;김진호;김진만
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.43-53
    • /
    • 2008
  • 현재 국내에서 현장 체결공법으로 채용하고 있는 토크관리법은 토크계수를 근거로 해서 간접적으로 도입축력을 제어하는 방법이기 때문에 현장에서의 토크계수 관리가 상당히 중요하다. 따라서 본 연구에서는 현장 시공시 볼트보관방법 및 현장관리에서 일반적으로 발생할 수 있는 주요 환경 요인 중 수분 침투, 녹 발생, 외기노출, 와셔의 오용 등 다양한 실험변수로 계획하여 토크계수의 변화에 따른 도입축력의 차이를 확인하기 위하여 실험을 수행했다. 실험에 사용된 볼트는 육각 고력볼트, TS 고력볼트, 아연피막처리 육각 고력볼트, ASTM A490 고력볼트로서 4종류로 구분하여 수행되었고, 각 볼트별로 시공환경에 따른 체결특성을 비교 분석하였다.

볼트 체결에 의한 직선운동베어링 레일 변형에 관한 연구 (A Study on the Deflection of Rail by Bolt Tightening)

  • 김태범;이상조;김익수;이위로
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.794-797
    • /
    • 2001
  • The basic design of today s rolling linear guides with rails is outlined in a French patent from 1932, it was not until the early 1970s that linear guides were commercialized. Progress with the numerical control of machine tools led to higher speed and accuracy of machines that exposed limitations of conventional sliding guides in terms of durability and response capability. As a result, rolling guides, having better high-speed performance and greater compatibility with electronics, began to be used widely. This paper examined theoretically and experimentally the influence of rail bolt tightening on the motion accuracy of linear guides. The rail of a linear guide is tightened and fixed to the base component by bolts. Naturally, the rail is an elastic body and the compression force generated by tightening the volts causes its deflection. Compromising motion accuracy, the rail deforms wavily in a longitudinal direction corresponding to the bolt pitch. The relation between rail position and deflection(sinking) amount caused by bolt tightening was analyzed through FEM analysis in this paper.

  • PDF

치과용 임플랜트에서 지대주 나사의 길이 및 반복 조임 횟수가 지대주 나사의 풀림에 미치는 영향 (THE INFLUENCE OF ABUTMENT SCREW LENGTH AND REPEATED TIGHTENING ON SCREW LOOSENING IN DENIAL IMPLANT)

  • 최진호;양재호;조원표;이재봉
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.432-442
    • /
    • 2006
  • Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF

3본 나사 유지형 임플란트 보철물의 고정 방식에 따른 임플란트 고정체 치경부에 발생하는 변형율 비교분석 (Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses)

  • 김상범;이두형;이청희
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.321-327
    • /
    • 2020
  • 목적: 본 연구의 목적은 3본 나사 유지형 임플란트 보철물의 나사 고정 방식에 따른 치경부에 발생하는 변형율을 측정하고 비교하기 위함이다. 재료 및 방법: 2가지 종류의 임플란트(외부연결방식, 내부연결방식)를 각각 2개씩 4개 임플란트 고정체 경부에 스트레인 게이지를 부착한 후, 각 종류의 아크릴릭 레진 모형 2개를 제작하였다. CAD-CAM을 이용하여 hex 및 nonhex 지대주를 제작하였고,(EH, ENH, IH& INH 군) 나사-시멘트 유지보철 개념으로 보철물을 비귀금속으로 제작하였다. 각 지대주를 10 Ncm 토크로 고정한 후, 보철물을 합착하였다. 나사를 3가지의 다른 방법으로 30 Ncm까지 고정한 다음, 5분 후 변형율을 측정한 후 평균비교 및 군간 상호작용을 평가하였다 (α = .05). 결과: 외부연결방식 군은 내부연결방식 군에 비하여 유의하게 낮은 변형율을 나타냈으며, EH군이 ENH군보다 유의하게 낮은 변형율을 나타내었으나 (P < .05), 나사 고정 방법에 따른 차이는 없었다 (P > .05). IH군이 INH군에 비하여 유의하게 높은 변형율을 나타내었으며 IH군에서만 나사 고정 방법에 따라서도 차이가 있었다 (P < .05). 결론: 나사 유지형 임플란트 보철물에서는 외부연결방식인 경우에는 큰 영향이 없으나, 내부연결방식에서는 보다 큰 변형율이 발생하고 나사 고정 방법도 영향을 주는 것으로 나타났다.

Rotational tolerances of a titanium abutment in the as-received condition and after screw tightening in a conical implant connection

  • Prisco, Rosario;Troiano, Giuseppe;Laino, Luigi;Zhurakivska, Khrystyna
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권6호
    • /
    • pp.343-350
    • /
    • 2021
  • PURPOSE. The success of an implant-prosthetic rehabilitation is influenced by good implant health and an excellent implant-prosthetic coupling. The stability of implant-prosthetic connection is influenced by the rotational tolerance between anti-rotational features on the implant and those on the prosthetic component. The aim of this study is to investigate the rotational tolerance of a conical connection implant system and its titanium abutment counterpart, in various conditions. MATERIAL AND METHODS. 10 preparable titanium abutments, having zero-degree angulation (MegaGen, Daegu, Korea) with an internal 5-degree conical connection, and 10 implants (MegaGen, Daegu, Korea) were used. Rotational tolerance between the connection of implant and titanium abutments was measured through the use of a tridimensional optics measuring system (Quick Scope QS250Z, Mitutoyo, Kawasaki, Japan) in the as-received condition (Time 0), after securing with a titanium screw tightening at 35 Ncm (Time 1), after tightening 4 times at 35 Ncm (Time 2), after tightening one more time at 45 Ncm (Time 3), and after tightening another 4 times at 45 Ncm (Time 4). RESULTS. The group "Time 0" had the lowest values of rotational freedom (0.22 ± 0.76 degrees), followed by the group Time 1 (0.46 ± 0.83 degrees), the group Time 2 (1.01 ± 0.20 degrees), the group Time 3 (1.30 ± 0.85 degrees), and the group Time 4 (1.49 ± 0.17 degrees). CONCLUSION. The rotational tolerance of a conical connection is low in the "as received" condition but increases with repetitive tightening and with application of a torque greater than 35 Ncm.

다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구 (Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique)

  • 김동욱;최유성;조인호
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.343-358
    • /
    • 2011
  • 임플랜트 치료가 보편화되고, 다양한 형태와 재료의 상부 구조물이 보급되었다. 그리고 실패에 대한 보고도 다양하며, 그 중 지대나사의 풀림현상이 가장 흔하다고 지적되고 있다. 본 연구는 외부연결구조와 내부연결구조 임플랜트에 의해 지지되는 상부 구조물을 나사로 연결할 때, 세 가지 나사조임순서와 두 가지 나사조임방법에 따른 나사의 풀림 토크값을 비교하여 나사조임순서와 나사조임방법이 서로 다른 연결구조에 따라 나사풀림현상에 미치는 영향을 알아보고자 하였다. 완전 무치악 하악모형을 자가중합형 아크릴릭 레진으로 제작하고 이공간 부위에 중심간 거리가 약 15 mm 되도록 네 개의 임플랜트 고정체 유사체를 고정한 후 바 타입으로 납형 형성하여 상부 구조물을 주조 제작하였다. 상부 구조물과 정확한 적합이 되는 주모형을 제작한 후 연결 인상법으로 외부연결구조, 내부연결구조를 가지는 연구모형을 각각 5개씩 제작하였다. 각 모형에서 각 나사의 풀림 토크값을 가장 왼쪽에 조여지는 나사를 1번 나사로 하고 가장 오른쪽의 나사를 4번 나사로 명명하였다. 먼저, 나사조임순서의 영향을 알아보기 위해 1-2-3-4, 2-3-1-4, 2-4-3-1의 순서로 15 Ncm의 힘으로 조이고, 다시 같은 순서로 최종 조임토크값인 30 Ncm까지 조인 후 (2-step 방법) 각 나사의 풀림 토크값을 측정하였다. 또한 나사조임방법의 영향을 알아보기 위해 2-3-1-4의 순서로 한 번에 최종 조임토크값인 30 Ncm까지 조인 후 (1-step 방법) 각 나사의 풀림 토크값을 측정하여 같은 순서 (2-3-1-4)의 2-step 방법과 비교하였다. 세 가지 나사조임순서에 따른 나사의 풀림 토크값은 외부연결구조에서 2-3-1-4군이 2-4-3-1군보다 유의하게 낮았다 (p<0.05). 그리고 내부연결구조에서도 2-3-1-4군이 2-4-3-1군과 1-2-3-4군보다 유의하게 낮았다 (p<0.05). 또한 나사조임순서와 무관하게 몇 번째 조여진 나사인지에 따른 풀림 토크값을 비교해 본 결과, 외부연결구조에서는 처음에 조여진 나사가 두 번째 조여진 나사보다 유의하게 높았으나 (p<0.05), 내부연결구조에서는 처음에 조여진 나사에서부터 마지막에 조여진 나사 간에 차이가 없었다. 그리고 두 가지 나사조임방법 간에는 외부연결구조와 내부연결구조 모두에서 통계학적으로 유의한 차이가 없었다. 연결구조에 대한 비교에서 외부연결구조와 내부연결구조의 풀림 토크값은 각각 16.27 Ncm, 14.25 Ncm 였으며, 통계적으로 유의한 차이가 나타났다 (p<0.05). 다수 임플랜트에 의해 지지되는 상부 구조물을 나사로 연결할 때, 나사조임순서에 따라 차이가 있었으며, 가운데부터 조인 경우에서 풀림 토크값이 낮았고, 연결구조 간에도 차이가 있었다. 풀림 토크값에 미치는 요인에 대해 좀 더 상세히 분석할 필요가 있으며, 하중 조건에서의 부가적인 연구가 필요할 것으로 사료된다.