Confinement Effects of Reinforced Concrete Tied Columns (철근콘크리트 띠철근 기둥의 구속효과)

  • 왕성근;한범석;이희수;신성우;반병열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.29-34
    • /
    • 2001
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$120mm) were fabricated to simulate similarly an actual structural members size. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were studied in this research program.

  • PDF

The Empirical Study on the Relationship between Innovation Type and Network Configuration of IT SMEs (중소 IT기업의 혁신유형별 네트워크 형태에 대한 실증 연구)

  • Kim, Sun-Woo;Lee, Jang-Jae;Lee, Chul-Woo
    • Journal of the Korean association of regional geographers
    • /
    • v.12 no.6
    • /
    • pp.693-703
    • /
    • 2006
  • Keeping the balance between exploration of new possibilities and exploitation of existing certainties in organizational innovation is getting its significance as business environments become more turbulent This paper focused on the relationship between two different types of innovation and network configuration. For this purpose, we conducted the empirical studies of 168 IT SMEs located in Gyeongbuk. For this analysis, we defined two innovation types as exploratory innovation and exploitative innovation. Also, we considered network scope and strength of tie as network configuration. The results showed that the exploratory innovation had sparse network of network scope and weak tie of strength. On the contrary the exploitative innovation had dense network and strong tie.

  • PDF

Optimal Division Model Configuration Plan According to 6 Divisions 3 Ties in Korea Distribution System (국내 배전계통의 6분할 3연계 최적분할 모델 구성방안)

  • Lee, Dae-Dong;Son, Sung-Hwan;Ha, Bok-Nam;Hyun, Dong-Seok;Kim, Young-Dal
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.428-433
    • /
    • 2010
  • According as economy grows, demand for power increases and satisfaction of customer about electricity quality is rising. There is in trend that investment expense by continuously increased supply of electric power equipment is on the increase continuously, but management efficiency improvement through curtailment of supply of electric power equipment investment expense through efficient operation is required rather than to increase investment. In this study, reconsidered about 6 divisions 3 ties that is distribution line basis configuration of Daejeon Geumsan area and analyzed division and tie present condition of truthful distribution System. Examined problem analyzing average division number, tie number and tie switch number, searched about most suitable division that consider load. Hereafter, I wish to take advantage of analysis result in most suitable division and tie of truthful distribution system for power failure section reduction and investment expense curtailment.

Convergence Technique Study of Model Tie Rod End by Configuration through Simulation Analysis (시뮬레이션 해석을 통한 형상 별 타이로드 엔드 모델의 융합 기술 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.1
    • /
    • pp.161-166
    • /
    • 2016
  • Deformation, stress and fatigue life due to the configuration of tie rod end are investigated in this study. Tie rod ends with the total three kinds of configurations are modelled with three dimensions through CATIA program and the simulation analysis is carried out with the ANSYS finite element analysis program. There are the models of A, B and C by the configuration of the rod end. As this study result, maximum deformation, maximum equivalent stress and maximum fatigue life of A type model are shown to be 0.0614mm, 160.27MPa and 336,930cycles respectively. And maximum deformation, maximum equivalent stress and maximum fatigue life of B type model are shown to be 0.0648mm, 90.889MPa and 1,171,000cycles respectively. Maximum deformation, maximum equivalent stree and maximum fatigue life of C type model are also shown to be 0.0402mm, 84.794MPa and 20,000,000cycles respectively. The durability of the models of tie rod ends through the values of this result could be estimated and the data for the design and development of more improved tie rod end could be secured. And it is possible to be grafted onto the convergence technique at design and be shown as the esthetic sense.

Structural Durability Analysis of Tie Rod (타이로드의 구조적 내구성 해석)

  • Han, Moon-Sik;Cho, Jae-Ung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.68-75
    • /
    • 2012
  • This study aims at the structural analysis of vibration and fatigue according to the tie rod configuration. The maximum displacement amplitude is happened at 156Hz by harmonic vibration analysis, this tie rod model can be broken as the weakest state. Among the cases of nonuniform fatigue loads, 'SAE bracket history' with the severest change of load becomes most unstable but 'Sine wave' becomes most stable. In case of 'Sine wave' with the average stress of 0MPa and the amplitude stress of 570MPa, the possibility of maximum damage becomes 70%. This stress state can be shown with 140 times more than the damage possibility of 'SAE bracket history' or 'SAE transmission'. The structural result of this study can be effectively utilized with the design on tie rod by investigating prevention and durability against its damage.

Nonlinear finite element model of the beam-to-column connection for precast concrete frames with high ratio of the continuity tie bars

  • Sergio A. Coelho;Sergio A. Coelho
    • Computers and Concrete
    • /
    • v.31 no.1
    • /
    • pp.53-69
    • /
    • 2023
  • The rotational stiffness of a semi-rigid beam-to-column connection plays an important role in the reduction of the second-order effects in the precast concrete skeletal frames. The aim of this study is to present a detailed nonlinear finite element study to reproduce the experimental response of a semi-rigid precast beam-to-column connection composed by corbel, dowel bar and continuity tie bars available in the literature. A parametric study was carried using four arrangements of the reinforcing tie bars in the connection, including high ratio of the continuity tie bars passing around the column in the cast-in-place concrete. The results from the parametric study were compared to analytical equations proposed to evaluate the secant rotational stiffness of beam-to-column connections. The good agreement with the experimental results was obtained, demonstrating that the finite element model can accurately predict the structural behaviour of the beam-to-column connection despite its complex geometric configuration. The secant rotational stiffness of the connection was good evaluated by the analytical model available in the literature for ratio of the continuity tie bars of up to 0.69%. Precast beam-to-column connection with a ratio of the continuity tie bars higher than 1.4% had the secant stiffness overestimated. Therefore, an adjustment coefficient for the effective depth of the crack at the end of the beam was proposed for the analytical model, which is a function of the ratio of the continuity tie bars.

A Study on the Manufacture of Aluminum Tie-Rod End by Casting/Forging Process (주조/단조 기술을 이용한 알루미늄 타이로드 엔드 제조에 관한 연구)

  • Kim, Hyo-Ryang;Seo, Myung-Kyu;You, Min-Su;Bae, Won-Byong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.180-185
    • /
    • 2002
  • Aluminum casting/forging process is used to produce an aluminum tie-rod end for the steering system of automobiles. Firstly, casting experiments were carried out to get a good preform for forging the tie-rod end. In the casting experiment, the effects of additives, Ti+B, Zr, Sr, and Mg, on the mechanical properties and the microstructure of a cast preform were investigated. And a finite element analysis was performed to determine an optimal configuration of the cast preform. Lastly, a forging experiment was carried out to make the final product of aluminum tie-rod end by using the above cast preform. In the casting experiments, when 0.2% Ti+B and 0.25% Zr were simultaneously added into molten Al-Si alloy, the highest values of tensile strength and elongation of the cast preform were obtained. When 0.04% Sr were added into the molten aluminum alloy, the finest silicon-structure was observed in the cast preform. The highest hardness was obtained when 0.2% Mg was added. In the forging experiment, It was confirmed that the optimal configuration of a cast preform predicted by FE analysis was very useful. The hardness of a cast/forged product using designed preform was superior to that of required specification.

Strength enhancement in confined concrete with consideration of flexural flexibilities of ties

  • Teerawong, J.;Lukkunaprasit, P.;Senjuntichai, T.
    • Structural Engineering and Mechanics
    • /
    • v.18 no.2
    • /
    • pp.151-166
    • /
    • 2004
  • The interaction between concrete core expansion and deformation of perimeter ties has been known to have a significant effect on the effective confinement of rectangular reinforced concrete (RC) tied columns. This interaction produces passive confining pressure to the concrete core. Most existing models for determining the response of RC tied columns do not directly account for the influence of flexural stiffness of the ties and the variation of confining stress along the column height. This study presents a procedure for determining the confined compressive strength of RC square columns confined by rectilinear ties with various tie configurations considering directly the influence of flexural flexibility of the ties and the variation of confining stress along the vertical direction. The concept of area compatibility is employed to ensure compatibility of the concrete core and steel hoop in a global sense. The proposed procedure yields satisfactory predictions of confined strengths compared with experimental results, and the influence of tie flexibility, tie configuration and degree of confinement can be well captured.

Section Voltage Calculation while a Loop Operation by Tie-Switch Close in a Distribution Management System (배전운영 시스템에서 상시개방 연계 스위치 투입에 의한 루프 운전 중 구간전압 계산 방법)

  • Seo, Jeong-Soo;Lim, Il-Hyung;Park, Jong-Ho;Shin, Yonh-Hak;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.397-403
    • /
    • 2016
  • Generally, an electrical distribution configuration is a radial system with one-way current in a distribution management system (DMS). All feeders in a DMS have tie-switches to make radial system. Sometimes, DMS should change a tie-switch for operation. In that case, the tie-switch has to be closed first; then a switch is opened as another tie-switch in order to prevent blackout for customers. At the moment when the tie-switch is closed, distribution system is operated in a loop state, not radial. Before the loop operation, DMS operator has to check any expected events for stable distribution system operation; and the most important event is a mis-operation of a protection relay. In addition, DMS operator should check voltage profile violation but a calculation method of section voltages had not been used. Thus, this paper proposes a calculation method of section voltages at a loop operation in a DMS. The proposed calculation algorithm is verified by Matlap Simulink.

A simplified framework for estimation of deformation pattern in deep excavations

  • Abdollah Tabaroei;Reza Jamshidi Chenari
    • Geomechanics and Engineering
    • /
    • v.37 no.1
    • /
    • pp.31-48
    • /
    • 2024
  • To stabilize the excavations in urban area, soil anchorage is among the very common methods in geotechnical engineering. A more efficient deformation analysis can potentially lead to cost-effective and safer designs. To this end, a total of 116 three-dimensional (3D) finite element (FE) models of a deep excavation supported by tie-back wall system were analyzed in this study. An initial validation was conducted through examination of the results against the Texas A&M excavation cases. After the validation step, an extensive parametric study was carried out to cover significant design parameters of tie-back wall system in deep excavations. The numerical results indicated that the maximum horizontal displacement values of the wall (δhm) and maximum surface settlement (δvm) increase by an increase in the value of ground anchors inclination relative to the horizon. Additionally, a change in the wall embedment depth was found to be contributing more to δvm than to δhm. Based on the 3D FE analysis results, two simple equations are proposed to estimate excavation deformations for different scenarios in which the geometric configuration parameters are taken into account. The model proposed in this study can help the engineers to have a better understanding of the behavior of such systems.