Purpose: The purpose of this study was to determine how the position of tibial rotation affects peak force and hamstring muscle activation during isometric knee flexion in healthy women. Methods: Seventeen healthy women performed maximum isometric knee flexion at 30˚ with three tibial rotation positions (tibial internal rotation, neutral position, and tibial external rotation). Surface electromyographic (EMG) activity was recorded from the medial hamstring (MH) and lateral hamstring (LH) muscles. The strength of the knee flexor was measured with a load-cell-type strength-measurement sensor. Data were analyzed using one-way repeated analysis of variance. Results: The results showed that MH and LH activities and peak force were significantly different among the three tibial rotation conditions (p < 0.01). The post-hoc comparison revealed that the MH EMG activity in tibial neutral and internal rotation positions were significantly greater than tibial external rotation (p < 0.01). The LH activity in tibial external rotation was significantly greater than the tibial neutral position and internal rotation (p < 0.01). The peak force of the knee flexor was also greater in the external tibial rotation position compared with the tibial neutral and internal rotation positions (p < 0.01). Conclusion: Our findings suggest that hamstring muscle activation could be changed by tibial rotation.
Journal of the Korean Society of Physical Medicine
/
v.12
no.1
/
pp.43-49
/
2017
PURPOSE: This study investigated the relationship among hip adduction angle, tibial rotation, and ITB length during an Ober test to determine the most appropriate position for performing the test. METHODS: The study included thirty-nine asymptomatic participants (23 males, 16 females). Their hip adduction angles were measured using the Ober test during three tibial rotation conditions (internal tibial rotation, external rotation, and neutral position). ITB length was calculated by measuring the position of the patella to lateral femoral condyle using ultrasonography (patella-condyle distance; PCD). RESULTS: The relationship among hip adduction angle, tibial rotation, and ITB length was analyzed under the three conditions using the Pearson correlation. The hip adduction angle of the internal tibial rotation, the external rotation, and the neutral position were significantly related to ITB length. Moreover, the hip adduction angle measured during the internal tibial rotation had the highest correlation with ITB length among the three conditions (r=.58, p<.001). CONCLUSION: Internal tibial rotation caused by the Ober test led to increased iliotibial band (ITB) tension and a decreased adduction angle. These findings support that tibial rotation influences the flexibility of ITB. Therefore, therapists should consider the position of the internal tibial rotation when taking measurements using an Ober test.
This study was performed to investigate the effects of tibial rotation while going up stair on muscle activity of vastus medialis oblique and vastus lateralis, and on patellar displacement. The subjects included 30 people (male: 15; female: 15) who were randomly assigned to the tibial internal-rotation, neutral-rotation, and external-rotation groups. The subjects went up the stair while performing the assigned rotations, and the rotation of the hip and the displacement of the patella were measured using a 3D motion analyzer. In addition, the maximum voluntary isometric contraction (MVIC) of the vastus medialis oblique and vastus lateralis were measured using surface electromyogram. On the tibial internal rotation, the hip rotation significantly appeared in the same direction and so did on the tibial neutral and external rotations(p<.001). Although the MVIC of the vastus medialis oblique and vastus lateralis did not significantly differ by tibial rotation during the stair ascent, the MVIC of the vastus medialis oblique was higher than that of the vastus lateralis during the internal and neutral rotations (p<.05). In addition, during the stair ascent, the displacement of the patella was more significant during the tibial external rotation than during the tibial internal and neutral rotations(p<.001). Thus, patients with patellofemoral pain are required to be considered the effects of tibial rotation for their rehabilitation.
The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.
Background: The tibial tuberosity-trochlear groove (TT-TG) distance is used to determine the necessity of tibial tubercle osteotomy. We conducted this study to determine the extent to which each of the tibial tuberosity lateralization, trochlear groove medialization, and knee rotation angle affects the TT-TG distance in both normal and patella dislocated patients and thereby scrutinize the rationale for tuberosity transfer based on the TT-TG distance. Methods: Retrospective analysis of rotational profile computed tomography was done for patella dislocated and control group patients. Femoral anteversion, tibial torsion, knee rotation angle, tuberosity lateralization, and trochlear groove medialization were assessed in all patients. Relationship of these parameters with the TT-TG distance was investigated to evaluate their effects on the TT-TG distance. Results: We observed that the patellar dislocation group, compared to the control group, had increased TT-TG distance (mean, 19.05 mm vs. 9.02 mm) and greater tuberosity lateralization (mean, 64.1% vs. 60.7%) and tibial external rotation in relation to the femur (mean, $7.9^{\circ}$ vs. $-0.81^{\circ}$). Conclusions: Tuberosity lateralization and knee rotation were factors affecting patellar dislocation. These factors should be considered in addition to the TT-TG distance to determine the need for tibial tubercle osteotomy in patients with patellar dislocation.
Jeong, Youngeun;Jeong, Jaemin;Cho, Cheongwoon;Jeong, SeongMok;Lee, Hae Beom
Journal of Veterinary Clinics
/
v.37
no.4
/
pp.175-179
/
2020
The objective of this study was to determine the effect of osteotomy angle and tibial proximal segment rotation angle on angular and torsional tibial deformities and to assess the trends of these deformities during the rotation of the tibial proximal segment in a center of rotation of angulation (CORA)-based leveling osteotomy (CBLO) by performing computer modeling of the tibia. Four tibias of toy breed dogs with no history of lameness were used in this study. Osteotomies were performed in the proximal tibias at angles of 0°, 10°, 20°, -10°, and -20°, perpendicular to either the proximodistal or craniocaudal tibial axes. The mechanical medial proximal tibial angle (mMPTA) and transcondylar (TC) and distal cranial tibial (CnT) axes were used to measure angular and torsional deformities, respectively. All tibias showed an increase in angular and rotational deformities with an increase in the tibial plateau rotation angle. The tibia with osteotomies performed in the proximodistal and craniocaudal directions showed the highest magnitude of torsional and angular deformities, respectively. The results of this study revealed a tendency of occurrence of angular and torsional deformities with osteotomy performed along the proximodistal and craniocaudal directions in the CBLO.
The center of rotation of angulation-based leveling osteotomy (CBLO) has been introduced for the stabilization of cranial cruciate ligament rupture (CCLR) in small-breed dogs. This technique can be applied to the tibia without damaging its tuberosity. Although different designs of CBLO plates are available, tibial plateau leveling osteotomy (TPLO) plates have been still used for stabilization during CBLO. To the best of our knowledge, no studies have reported the effects of TPLO plates on the postoperative limb alignment after CBLO. Therefore, the present study (January 2020 to February 2021) aimed to compare the postoperative outcomes (postoperative tibial plateau angle [TPA] and tibial alignment) in patients receiving CBLO and TPLO plates during CBLO. Paired stifle joints (n = 16) were obtained from eight toy-breed cadaver dogs (mean weight, 4.4 kg) that underwent CBLO. The joints were randomly assigned to receive the CBLO (CBLO group) or TPLO plates (TPLO group). Pre-and postoperative radiographs were obtained, and the dissected tibiae were evaluated. The following postoperative parameters were compared to evaluate the surgical outcome: TPA, osteotomy location, mechanical medial proximal tibia angle, inter-segment gap, and tibial plateau translation. No significant differences were found in the postoperative alignment between the two groups. Therefore, TPLO plates may be considered as a viable alternative in toy-breed dogs undergoing CBLO.
Purpose: The purpose of this study was to examine EMG activities and VMO/VL ratio of the vastus medialis oblique, vastus lateralis, and rectus femoris during squat exercise (knee angle: 15, 45, and 60 degrees; tibial rotation: internal rotation, neutral, and external rotation). Methods: Twelve subjects performed squat exercise at each knee angle and tibial rotation while electromyographic (EMG) activity was collected. Statistical analysis consisted of two-way repeated measures analysis of variance with post hoc analysis. Results: There were significant main effects of knee angles and foot positions and interaction effect on EMG activities of vastus medialis oblique and vastus lateralis. VMO/VL ratios were significantly different by tibial rotations and there was an interaction effect. A neutral position produced significantly more VMO/VL activity ratio than that from internally rotated position and externally rotated position at 60 degrees. Conclusion: Considering the interaction effects for EMG activity across quadriceps muscles tested, the 60 degrees knee angle with a neutral foot position may provide the most effective condition for patients with acute patellofemoral syndrome.
Background: The hamstring muscles in the lower extremity are highly important for knee joint stability and can be classified into medial and lateral hamstrings according to the anatomical position, which have some different functions. To measure the strength of the individual hamstring muscles, manual muscle testing is clinically performed by dividing rotation postures into internal and external postures. However, this has no sufficient scientific background. Objects: This study aimed to test the difference that the tibial rotation would cause in the muscle activity of the medial and lateral hamstrings. Methods: The muscle activities of the biceps femoris, semitendinosus, and semimembranosus were measured in a total of three different postures (neutral position and internal and external rotations) with 3 replications. During the maximal isometric contraction, resistance was constantly provided by the string attached to the strap, not by manual resistance of the examiner. Before and after electromyography measurements, the participants underwent hamstring flexibility measurement using the active knee extension test in the supine position on the treatment table. Results: The semitendinosus had a 12.56% reduction in muscle activity in external rotation as compared with that in neutral position. The biceps femoris and semimembranosus showed reduced muscle activities in both external and internal rotations as compared with those in neutral position. Only the women showed significant decreases in the comparison between pre and post-active knee extension. Conclusion: Only the semitendinosus muscle was consistent with the anatomical speculation. However, the reduction in the muscle activity of the semitendinosus as compared with that in neutral position was only 12.56%, the clinical value of which may be difficult to justify.
Journal of the Korean Society of Physical Medicine
/
v.13
no.2
/
pp.33-41
/
2018
PURPOSE: Femur and tibia alignment in the knee joint is important to the biomechanics of lower limb movement. The purpose of this study was to compare vastus medialis oblique (VMO) and vastus lateralis electromyographic muscle activities according to tibial rotation taping methods. METHODS: Twenty-nine healthy subjects (13 males and 16 females) in the 20s, without knee joint-related diseases or disorders, participated in our study. After identifying each subject's dominant foot, the maximal voluntary isometric contraction (MVIC) was determined using a manual muscle tester. The activity of each target muscle was measured at 50% MVIC in isometric muscle contraction and at a $30^{\circ}$ knee flexion position before and after applying internal and external rotation taping by the Mulligan concept and in the neutral position. Non-elastic tape was used to stabilize the tibia rotation position. RESULTS: In the males, VMO muscle activity was significantly increased in the tibia internal rotation position ($47.2{\pm}14.6$, $mean{\pm}SD$) than in the neutral position ($39.3{\pm}14.9$) (p<.05). CONCLUSION: The results of this study indicate that when applying tibia internal rotation taping in healthy males, VMO muscle activity significantly increases during isometric extension of the knee. Therefore, this study provides a basis for selecting the appropriate taping method, in consideration of the available treatments in clinical practice for patients with knee problems.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.