• Title/Summary/Keyword: Thyroid fine-needle aspiration

Search Result 148, Processing Time 0.021 seconds

The Diagnostic Accuracy of Fine Needle Aspiration Cytology and the Diagnostic Usefulness of Galectin-3 Immunostaining for the Follicular Variant of Papillary Thyroid Carcinoma (소포성 갑상샘 유두암종의 세침흡인 세포검사의 정확도와 Galectin-3 면역염색의 유용성)

  • Jung, Chan-Kwon;Shin, Jung-Ha;Lee, Hyun-Seung;Lee, Ah-Won;Jung, Eun-Sun;Choi, Yeong-Jin;Lee, Kyo-Young
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.160-163
    • /
    • 2008
  • The cytologic diagnosis of the follicular variant of papillary thyroid carcinoma (FVPTC) has become one of the common causes of false negative diagnoses when performing fine needle aspiration cytology (FNAC) of the thyroid gland. We retrospectively reviewed all the aspirates for which a diagnosis of FVPTC had been made based on the surgically excised specimens, regardless of the cytologic diagnosis. 145 FNACs was performed in 135 patients. The cytologic diagnoses were categorized as 2 unsatisfactory specimens (1.4%), 16 benign (11.0%), 49 atypical (33.8%) and 78 malignant lesions (53.8%). The tumor cells consistently showed significant nuclear overlapping, irregular nuclei and fine chromatin in all cases; however, nuclear grooves and inclusions were scarce. Galectin-3 immunostaining was performed on the cell blocks of 65 cases and this was positive for 45 cases (69.2%). The results of our study demonstrate that the determination of minimal cytologic criteria is needed to raise the sensitivity of detecting FVPTC by FNAC, and galectin-3 immunostaining is useful to make decisions on the surgical treatment of cytologically atypical thyroid nodules.

Morphometric Study on Fine Needle Aspirates from Follicular Adenoma and Follicular Carcinoma of the Thyroid (세침흡인된 갑상선의 여포상 선종과 여포상 암종의 형태계측학적 연구)

  • Chu, Young-Chae;Cha, Hee-Jung;Min, Soo-Kee;Kim, Joon-Mee;Hwang, Tae-Sook
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 1998
  • Fine needle aspiration cytology of "cold" nodules of the thyroid has proved to be of great value in their preoperative diagnosis. Most types of thyroid tumors are readily recognizable from characteristic cellular patterns in the smears of needle aspirates. But follicular neoplasms present some problems because the cytomorphology of the adenomas frequently is same as in carcinoma. For differentiation of benign from malignant follicular neoplasms of the thyroid we tested the usefulness of two objective parameters - nuclear area and perimeter - by morphometry. This study was made on fine needle aspirates from 30 cases with cytologic diagnosis of follicular neoplasm of thyroid. The histologic classification was follicular adenoma in 22 cases and follicular carcinoma in 8 cases. As a reference group we used seven caes with nodular hyperplasia. The smears of aspirates were stained by Papanicolaou method. On each slide 200 randomly selected cells with intact nuclei were measured. The mean value of nuclear area are $25.32{\pm}5.50{\mu}m^2,\;34.08{\pm}7.50{\mu}m^2\;and\;39.97{\pm}6.63{\mu}m^2$ in nodular hyperplasia, follicular adenoma, and follicular carcinoma, respectively. The mean value of perimeter are $19.48{\pm}2.26{\mu}m,\;22.95{\pm}2.65{\mu}m\;and\;24.78{\pm}2.23{\mu}m$ in nodular hyperplasia, follicular adenoma and follicular carcinoma, respectively. The mean nuclear areas and perimeters of cells from follicular adenoma were significantly larger than those from nodular hyperplasia (p<0.05). The mean nuclear areas and perimeters of cells from follicular carcinoma were larger than those from follicular adenoma but the differences are not significant statistically(p>0.05). Therefore, morphometric assessment alone is inadequate to predict malignancy in thyroid aspirates.

  • PDF

Fine Needle Aspiration Cytology of the Hyalinizing Trabecular Adenoma of the Thyroid Gland - A Case Report - (갑상선 유리질 소주형 선종의 세침흡인 세포학적 소견 - 1예 보고 -)

  • Kim, Seong-Ho;Paik, Seung-Sam;Park, Moon-Hyang
    • The Korean Journal of Cytopathology
    • /
    • v.10 no.2
    • /
    • pp.175-178
    • /
    • 1999
  • Hyalinizing trabecular adenoma is an uncommon benign thyroid tumor that is recently described in the literature. This tumor is easily confused with medullary carcinoma on surgical specimens and with papillay carcinoma on cytologic specimens. Herein we report the cytologic characteristics of a case of histologically proven hyalinizing trabecular adenoma of the thyroid gland. Cytologically, the aspirate showed trabecular or individually dispersed polygonal cells with finely stippled chromatin pattern, nuclear grooves, and eosinophilic nuclear pseudoinclusions. No colloid materials were noted in the background.

  • PDF

Technical Report: A Cost-Effective, Easily Available Tofu Model for Training Residents in Ultrasound-Guided Fine Needle Thyroid Nodule Targeting Punctures

  • Yun-Fei Zhang;Hong Li;Xue-Mei Wang
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.166-170
    • /
    • 2019
  • Objective: To establish a cost-effective and easily available phantom for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures. Materials and Methods: Tofu, drinking straws filled with coupling gel, a urine tube, and 21-gauge needles were used to generate a phantom thyroid with nodules for training. Twelve radiology residents were involved in the study. The puncture success rates were recorded and compared before and after phantom training using the Wilcoxon signed-rank test. Results: On ultrasonography, tofu mimicked the texture of the thyroid. Drinking straws filled with coupling gel mimicked vessels. The urine tube filled with air mimicked the trachea, and 21-gauge needles mimicked small nodules in the transverse section. The entire phantom was similar to the structure of the thyroid and surrounding tissues. The puncture success rates of radiology residents were significantly increased from 34.4 ± 14.2% to 66.7 ± 19.5% after training (p = 0.003). The phantom was constructed in approximately 10 minutes and materials cost less than CNY 10 (approximately $ 1.5) at a local store. Conclusion: The tofu model was cost-effective, easily attainable, and effective for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures in vitro.

The Usefulness of Immunocytochemistry of CD56 in Determining Malignancy from Indeterminate Thyroid Fine-Needle Aspiration Cytology

  • Cha, Hyunseo;Pyo, Ju Yeon;Hong, Soon Won
    • Journal of Pathology and Translational Medicine
    • /
    • v.52 no.6
    • /
    • pp.404-410
    • /
    • 2018
  • Background: Fine-needle aspiration cytology serves as a safe, economical tool in evaluating thyroid nodules. However, about 30% of the samples are categorized as indeterminate. Hence, many immunocytochemistry markers have been studied, but there has not been a single outstanding marker. We studied the efficacy of CD56 with human bone marrow endothelial cell marker-1 (HBME-1) in diagnosis in the Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) category III. Methods: We reviewed ThinPrep liquid-based cytology (LBC) samples with Papanicolaou stain from July 1 to December 31, 2016 (2,195 cases) and selected TBSRTC category III cases (n=363). Twenty-six cases were histologically confirmed as benign (six cases, 23%) or malignant (20 cases, 77%); we stained 26 LBC slides with HBME-1 and CD56 through the cell transfer method. For evaluation of reactivity of immunocytochemistry, we chose atypical follicular cell clusters. Results: CD56 was not reactive in 18 of 20 cases (90%) of malignant nodules and showed cytoplasmic positivity in five of six cases (83%) of benign nodules. CD56 showed high sensitivity (90.0%) and relatively low specificity (83.3%) in detecting malignancy (p=.004). HBME-1 was reactive in 17 of 20 cases (85%) of malignant nodules and was not reactive in five of six cases (83%) of benign nodules. HBME-1 showed slightly lower sensitivity (85.0%) than CD56. The specificity in detecting malignancy by HBME-1 was similar to that of CD56 (83.3%, p=.008). CD56 and HBME-1 tests combined showed lower sensitivity (75.0% vs 90%) and higher specificity (93.8% vs 83.3%) in detecting malignancy compared to using CD56 alone. Conclusions: Using CD56 alone showed relatively low specificity despite high sensitivity for detecting malignancy. Combining CD56 with HBME-1 could increase the specificity. Thus, we suggest that CD56 could be a useful preoperative marker for differential diagnosis of TBSRTC category III samples.

A Study of Usefulness of Fine Needle Aspiration Cytology of the Thyroid Lesions (갑상선 병변의 세침흡인 세포검사의 유용성에 관한 연구)

  • Kwon, Kye-Hyun;Jin, So-Young;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.111-121
    • /
    • 1996
  • Fine needle aspiration cytology(FNAC) is preferred because of simplicity, safety, and reliability in the evaluation of patients with thyroid nodule or hyperplasia. However, there are a few limitations such as false-negative or false-positive cases and non-diagnostic material. To evaluate the usefulness of FNAC in thyroid lesions, we reviewed 704 FNAC cases of thyroid nodules from 1988 to 1994 at Soonchunhyang University Hospital. The results are as follows. 1. Among 704 FNAC cases of thyroid gland, 571(81.1%) cases were benign, 12(1.7%) were suspicious, 71(10.1%) were malignancy, and 50(7.1%) were material insufficiency. The cytologic diagnoses of the benign lesions included 168 cases of follicular neoplasm, 139 cases of adenomatous goiter, 162 cases of follicular lesion such as follicular neoplasm or adenomatous goiter, 61 cases of Hashimoto's thyroiditis, 13 cases of subacute thyroiditis, and 28 cases of colloidal nodule or benign nodule. The malignant lesions included 68 cases of papillary carcinona, two medullary carcinomas and a case of metastatic colon cancer. 2. The average number of cytologic smear slides was $4.12{\pm}1.81$ in material insufficiency and $5.63{\pm}1.79$ in diagnostic cases. This difference was statistically significant(p<0.00001). 3. Histological assessment of 150 cases revealed 2 false negative and 1 false positive cases. The false negative cases were a case of marked sclerosis in papillary carcinoma and an occult case of papillary carcinoma. The false positive case resulted from pseudo-ground glass nuclei due to marked dry artifact. 4. Comparison between the FNAC and the histologic diagnosis revealed that FNAC had a sensitivity of 93.5%, a specificity of 99.2%, a false negative rate of 6.6%, a false positive rate of 0.8%, and an overall diagnostic accuracy of 98.0%. Therefore, FNAC of thyroid gland is a very reliable diagnostic method with excellent accuracy rate.

  • PDF

Ultrasound Score to Select Subcentimeter-sized Thyroid Nodules Requiring Ultrasound-guided Fine Needle Aspiration Biopsy in Eastern China

  • Cheng, Pu;Chen, En-Dong;Zheng, Hua-Min;He, Qiu-Xiang;Li, Quan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4689-4692
    • /
    • 2013
  • Ultrasound-guided fine needle aspiration biopsy (FNAB) is a costly diagnostic item with a low yield in identifying the tiny proportion of nodules that actually represent malignant disease. Our aim through this study was to obtain an ultrasound (US) score for selecting subcentimeter-sized thyroid nodules requiring FNAB in eastern China. Some 248 patients for a total of 270 thyroid nodules less than 1 cm in diameter underwent FNAB and subsequent surgery from January 2006 to March 2012 at our hospital. The clinicopathological and US data from all the nodules were analyzed retrospectively. An US score was developed on the basis of independent predictive factors for malignancy. Irregular shape, hypoechogenicity, no well-defined margin, presence of calcifications and ratio between antero-posterior and transversal diameters (AP/TR) ${\geq}1$ were independent predictive factors for malignancy on logistic regression analysis. US score were statistically significant, with ${\leq}2$ favoring benignancy with an 80.3% sensitivity and a 72.7% specificity. US score is useful for differentiating between malignant and benign subcentimeter-sized thyroid nodules. We suggest FNAB for nodules when the US score is higher than 2.

Usefulness of Color-overlay Pattern of Thyroid Elastic Ultrasonography (갑상선 탄성 초음파 검사 시 칼라 오버레이 패턴의 유용성)

  • Park, Ji-Yeon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.341-346
    • /
    • 2022
  • The color overlay pattern of thyroid shear wave elastography applied in this study distinguishes benign and malignant nodules based on the optimal cut-off value of 74.2 kPa. From august 2021 to september 2021, thyroid ultrasound and elastography were performed on 57 patients with thyroid lesions using an ultrasound device RS85 prestige (Samsung Medison, Korea) and a 2-14 MHz linear transducer. In addition, the results of classification by K-TIRADS for each thyroid nodule and the results of classification by color overlay pattern according to the kPa value of acoustic ultrasound were compared and analyzed. In the color overlay pattern, the results classified as 40 people from dark blue to light blue and 17 people from green to red were similar to the K-TIRADS category results, which were classified as 42 benign and 15 malignant. Between blue and light blue, benign, and between green and red, malignant. If the shear wave elastography method is applied before the fine-needle aspiration cytology of the thyroid nodule is performed, the differential diagnosis of thyroid tissue from benign and malignant can be predicted in advance, and it will help to reduce unnecessary invasive tests.

Correlation and Accuracy Between Fine Needle Aspiration Cytology of Thyroid Lesions and Histopathologic Diagnosis -Analysis of 322 Histopathologically Confirmed Cases - (갑상샘 세침흡인 세포검사와 조직검사의 진단 일치율 및 정확도 분석 -조직학적으로 확진된 322 예에 대한 분석-)

  • Koo, Ja-Seung;Jung, Woo-Hee;Yang, Seok-Woo;Hong, Soon-Won
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.144-151
    • /
    • 2008
  • Fine needle aspiration (FNA) cytology is the decisive test in the pre-operative diagnostics of thyroid nodules. Here we share our institutional experience about thyroid aspiration and give suggestions for suspicious cytology results. Three hundred twenty-two cases in 270 patients (mean age 47.4 years, 243 women and 27 men) who underwent thyroidectomy were reviewed. Among the 322 cases, the FNA diagnosis of "positive for malignancy" was 87 cases (27.0%), "suggestive of malignancy" 30 cases (9.3%), "suspicious for malignancy" 61 cases (18.9%), "negative for malignancy" 102 cases (31.7%), and "unsatisfactory smear" 42 cases (13.0%). Eighty seven cases (100%) out of "positive for malignancy", 29 cases (96.7%) out of "suggestive of malignancy", and 39 cases (64.0%) out of "suspicious for malignancy" were papillary carcinoma (148 cases, 95.5%), or follicular carcinoma (2 cases, 1.3%), or metastatic carcinoma (1 case, 0.6%). Seventeen patients who had only negative or unsatisfactory cytology underwent thyroidectomy and nine cases (52.9%) were papillary carcinoma. We suggest that: the cytology diagnosis of "suggestive of malignancy" could be regarded as "positive for malignancy", the cytology diagnosis of "suspicious of malignancy" should be carefully correlated with clinico-radiologic manifestation, and even a negative or unsatisfactory smear should be carefully followed up.

Metastatic Melanoma Mimicking a Papillary Carcinoma of the Thyroid in Fine Needle Aspiration Cytology -A Case Report- (갑상샘 유두암을 닮은 전이성 흑색종의 세침 흡인 세포 소견 -1예 보고-)

  • Hong, Young-Ok;Suh, Jae-Hee;Cha, Hee-Jeong;Choi, Hye-Jeong;Kim, Young-Min
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.161-164
    • /
    • 2007
  • Metastasis to the thyroid gland is very rare in clinical practice. We recently encountered a 65-year-old woman who presented with a large thyroid nodule that mimicked the cytologic features of a papillary thyroid carcinoma on fine needle aspiration biopsy (FNAB). Although initially diagnosed as a papillary thyroid carcinoma, a thorough clinical work-up revealed multiple lesions in the bones, liver, and nasal cavity, which were confirmed as metastases of a malignant melanoma. Despite a thorough physical examination, however, the primary skin lesion could not be identified. Although FNAB shows a high degree of accuracy in diagnosing primary thyroid tumors, it is less accurate in diagnosing metastases to the thyroid gland. A thorough clinical history with appropriate immunohistochemical staining assays is necessary for the accurate diagnosis of metastatic malignant melanoma.