• 제목/요약/키워드: Thyroid Ultrasound

검색결과 74건 처리시간 0.022초

Technical Report: A Cost-Effective, Easily Available Tofu Model for Training Residents in Ultrasound-Guided Fine Needle Thyroid Nodule Targeting Punctures

  • Yun-Fei Zhang;Hong Li;Xue-Mei Wang
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.166-170
    • /
    • 2019
  • Objective: To establish a cost-effective and easily available phantom for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures. Materials and Methods: Tofu, drinking straws filled with coupling gel, a urine tube, and 21-gauge needles were used to generate a phantom thyroid with nodules for training. Twelve radiology residents were involved in the study. The puncture success rates were recorded and compared before and after phantom training using the Wilcoxon signed-rank test. Results: On ultrasonography, tofu mimicked the texture of the thyroid. Drinking straws filled with coupling gel mimicked vessels. The urine tube filled with air mimicked the trachea, and 21-gauge needles mimicked small nodules in the transverse section. The entire phantom was similar to the structure of the thyroid and surrounding tissues. The puncture success rates of radiology residents were significantly increased from 34.4 ± 14.2% to 66.7 ± 19.5% after training (p = 0.003). The phantom was constructed in approximately 10 minutes and materials cost less than CNY 10 (approximately $ 1.5) at a local store. Conclusion: The tofu model was cost-effective, easily attainable, and effective for training residents in ultrasound-guided fine needle thyroid nodule targeting punctures in vitro.

Clinical Application of Ultrasound-Guided Thyroid Fine Needle Aspiration Biopsy and Thinprep Cytology Test in Diagnosis of Thyroid Disease

  • Wei, Ying;Lu, Yao;Li, Chenxi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권10호
    • /
    • pp.4689-4692
    • /
    • 2016
  • Purpose: To study the clinical application value of ultrasound guided thyroid fine needle aspiration biopsy and thinprep cytology testing in diagnosis of thyroid disease. Methods: A total of 78 patients with thyroid nodules were enrolled, 34 males and 44 females, aged 33-64 years old with mean age of 47.6 years. All underwent thyroid module fine needle puncture after surgery to assess cell pathology and histopathological features. Results: Sufficient specimens were obtained from all of 78 patients, the cytological results of 73 cases (93.6 %) being consistent with pathological results. While 20 cases (25.6 %) were malignant tumors, 44 (56.4 %) were benign and 9 (11.5 %) were non-tumor lesions. The sensitivity of benign and malignant thyroid nodule by thyroid fine needle puncture was 90.9 %, specificity was 98.1 % and the positive predictive value was 96.3 %. Conclusions: It is demonstrated that ultrasound-guided thyroid fine needle aspiration biopsy and thinprep cytology testing have diagnostic value in clinical application for thyroid disease,showing good diagnostic coincidence rates with histopathological examination. They can thus be regarded as safe and effective for preoperative diagnosis and providing an appropriate basis for selection of surgery.

Shorter Distance Between the Nodule and Capsule has Greater Risk of Cervical Lymph Node Metastasis in Papillary Thyroid Carcinoma

  • Wang, Qiu-Cheng;Cheng, Wen;Wen, Xin;Li, Jie-Bing;Jing, Hui;Nie, Chun-Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권2호
    • /
    • pp.855-860
    • /
    • 2014
  • Background: The purpose of this study was to assess the relationship between different sonographic features of papillary thyroid carcinoma (PTC) on high-frequency ultrasound and cervical lymph node metastasis (CLNM). Materials and Methods: We enrolled 548 patients who underwent initial surgery for PTC between May 2011 and December 2012 in our hospital at diagnosis. The sonographic features of 513 PTC nodules in 513 eligible patients, who had single PTC nodules in their thyroid glands, were retrospectively investigated. All patients with a suspect malignant nodule (d<0.5cm) among multiple nodules were initially diagnosed by fine-needle aspiration biopsy (FNAB) to ascertain if the suspect nodule was PTC. The final diagnosis of all the thyroid nodules and existence of CLNM were based on postoperative pathology. Patients were divided into two groups: a positive group with CLNM (224 nodules) and a negative group without CLNM (289 nodules). The following factors were investigated: gender, age, echogenicity, echotexture, size, shape, location, margin, contour, calcification morphology, distance between the nodule and pre- or post-border of the thyroid capsule, vascularity and the differences between the two groups. Results: Correlation analysis showed that shorter distances between the nodule and pre- or postborder of thyroid capsule resulted in greater risk of CLNM (Spearman correlation coefficient=-0.22, p<0.0001). The significant factors in multivariate analysis were age<45yrs, larger size (d>1cm), "wider than tall" shape, extrathyroid extension and mixed flow (internal and peripheral) (p<0.05, OR=0.406, 2.093, 0.461, 1.610, 1.322). Conclusions: Significant sonographic features of PTC nodules in preoperative high-frequency ultrasound are crucial for predicting CLNM.

Conventional Ultrasonography and Real Time Ultrasound Elastography in the Differential Diagnosis of Degenerating Cystic Thyroid Nodules Mimicking Malignancy and Papillary Thyroid Carcinomas

  • Wu, Hong-Xun;Zhang, Bing-Jie;Wang, Jun;Zhu, Bei-Lin;Zang, Ya-Ping;Cao, Yue-Long
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.935-940
    • /
    • 2013
  • Background: To evaluate the diagnostic utility of conventional ultrasonography and real time ultrasound elastography in differentiating degenerating cystic thyroid nodules mimicking malignancy from papillary thyroid carcinoma. Methods: We retrospectively analyzed conventional ultrasonographic and elastographic characteristics of 19 degenerating cystic thyroid nodules mimicking malignancy in 19 patients, with 30 surgically confirmed PTCs as controls. Based on size, the nodules had been grouped into less than 10mm (group A) and greater than 10 mm (group B). We evaluated conventional parameters and elasticity pattern. Color-scaled elastograms were graded as to stiffness of nodules using an elasticity pattern from I (soft) to IV (stiff). Results: Degenerating cystic thyroid nodules were similar to PTCs in conventional ultrasonographic findings, but the former frequently showed oval to round in shape (group A, 69.2% vs 18.8%, P=0.017; group B, 66.7% vs 7.14%, P=0.017) and punctuate hyperechoic foci (group A, 61.5% vs 0, P<0.001; group B, 50% vs 0, P<0.001). On real time ultrasound elastography, 7 of 13 degenerating cystic thyroid nodules in group A were pattern I, 5 were pattern II, 1 was pattern III. One degenerating cystic thyroid nodule in group B was pattern II, 5 were pattern III. The area under the curve for elastography was 0.98 in group A (sensitivity 92.3%, specificity 100%, P = 0.002), and 0.88 in group B (sensitivity 16.7%, specificity 100%, P = 0.014). Conclusions: As a dependable imaging technique, elastography helps increase the performance in differential diagnosis of degenerating cystic thyroid nodule and malignancy.

Diagnostic Accuracy of Ultrasonography in Differentiating Benign and Malignant Thyroid Nodules Using Fine Needle Aspiration Cytology as the Reference Standard

  • Alam, Tariq;Khattak, Yasir Jamil;Beg, Madiha;Raouf, Abdul;Azeemuddin, Muhammad;Khan, Asif Alam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권22호
    • /
    • pp.10039-10043
    • /
    • 2014
  • Background: In Pakistan thyroid cancer is responsible for 1.2% cases of all malignant tumors. Ultrasonography (US) is helpful in detecting cancerous thyroid nodules on basis of different features like echogenicity, margins, microcalcifications, size, shape and abnormal neck lymph nodes. We therefore aimed to calculate diagnostic accuracy of ultrasound in detection of carcinoma in thyroid nodules taking fine needle aspiration cytology as the reference standard. Materials and Methods: A cross-sectional analytical study was designed to prospectively collect data from December 2010 till December 2012 from the Department of Radiology in Aga Khan University Hospital, Karachi, Pakistan. A total of 100 patients of both genders were enrolled after informed consent via applying non-probability consecutive sampling technique. Patients referred to Radiology department of Aga Khan University to perform thyroid ultrasound followed by fine-needle aspiration cytology of thyroid nodules were included. They were excluded if proven for thyroid malignancy or if their US or FNAC was conducted outside our institution. Results: The subjects comprised 76 (76%) females and 24 males. Mean age was $41.8{\pm}SD$ 12.3 years. Sensitivity and specificity with 95%CI of ultrasound in differentiating malignant thyroid nodule from benign thyroid nodule calculated to be 91.7% (95%CI, 0.72-0.98) and 78.94% (0.68-0.87) respectively. Reported positive predictive value and negative PV were 57.9% (0.41-0.73) and 96.8% (0.88-0.99) and overall accuracy was 82%. Likelihood ratio (LR) positive was computed to be 4.3 and LR negative was 0.1. Conclusions: Ultrasonography has a high diagnostic accuracy in detecting malignancy in thyroid nodules on the basis of features like echogenicity, margins, micro calcifications and shape.

갑상선 탄성 초음파 검사 시 칼라 오버레이 패턴의 유용성 (Usefulness of Color-overlay Pattern of Thyroid Elastic Ultrasonography)

  • 박지연;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.341-346
    • /
    • 2022
  • The color overlay pattern of thyroid shear wave elastography applied in this study distinguishes benign and malignant nodules based on the optimal cut-off value of 74.2 kPa. From august 2021 to september 2021, thyroid ultrasound and elastography were performed on 57 patients with thyroid lesions using an ultrasound device RS85 prestige (Samsung Medison, Korea) and a 2-14 MHz linear transducer. In addition, the results of classification by K-TIRADS for each thyroid nodule and the results of classification by color overlay pattern according to the kPa value of acoustic ultrasound were compared and analyzed. In the color overlay pattern, the results classified as 40 people from dark blue to light blue and 17 people from green to red were similar to the K-TIRADS category results, which were classified as 42 benign and 15 malignant. Between blue and light blue, benign, and between green and red, malignant. If the shear wave elastography method is applied before the fine-needle aspiration cytology of the thyroid nodule is performed, the differential diagnosis of thyroid tissue from benign and malignant can be predicted in advance, and it will help to reduce unnecessary invasive tests.

Correlation of Contrast-Enhanced Ultrasonographic Features with Microvessel Density in Papillary Thyroid Carcinomas

  • Zhou, Qi;Jiang, Jue;Shang, Xu;Zhang, Hong-Li;Ma, Wen-Qi;Xu, Yong-Bo;Wang, Hua;Li, Miao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7449-7452
    • /
    • 2014
  • Background: The purpose of this study was to investigate the correlation of contrast-enhanced ultrasonographic (CEUS) features with microvessel density (MVD) in papillary thyroid carcinomas (PTCs). Materials and Methods: Contrast-enhanced ultrasonography (CEUS) was performed in 62 patients (17 men and 45 women) with PTC. Tomtec software was applied to analyze the time intensity curve of CEUS. Immunohistochemistry was performed to evaluate the level of MVD in papillary thyroid carcinoma. Then the relationship between quantitative feature and the level of MVD was analyzed using SPSS 16.0 software. Results: The mean peak intensity of PTC tissues was lower than that of peripheral thyroid parenchyma ($61.9{\pm}11.8%$ vs 100%, p<0.05). The MVDs of CD34 and CD31 antibodies staining were $38.0{\pm}6.1$ and $37.9{\pm}5.1$ respectively in 62 PTC samples. A significantly positive correlation was observed between peak intensity and MVD in PTC tissues ($P_{CD34}$<0.01, $r_{CD34}$=0.838, $P_{CD31}$<0.01, $r_{CD31}$=0.837). Conclusions: The peak intensity in CEUS could reflect the MVD in PTC tissues. Therefore, quantification of CEUS seems to be helpful for assessment of MVD in PTC tissues.

GLCM과 인공신경망을 이용한 미만성 갑상샘 질환 초음파 영상 분류 (Ultrasound Image Classification of Diffuse Thyroid Disease using GLCM and Artificial Neural Network)

  • 엄상희;남재현;예수영
    • 한국정보통신학회논문지
    • /
    • 제26권7호
    • /
    • pp.956-962
    • /
    • 2022
  • 미만성 갑상샘 질환은 그 진단 기준이 모호하고 숙련자의 주관적인 진단에 따라 오류가 많이 발생한다. 초음파 영상에 영상처리기술을 적용하고 정량적 데이터를 추출하여 컴퓨터 보조 진단 시스템에 적용하게 되면 보다 정확하고 정략적인 진단이 가능하다. 본 논문에서는 갑상샘 질환 환자를 정상, 경도, 중등도로 분류된 초음파 영상에 GLCM 알고리즘을 적용하여 19개의 파라미터를 추출하였다. 이들 파라미터를 이용하여 인공신경망을 적용하여 미만성 갑상샘 초음파 영상을 분류하여 최종 96.9%의 분류율을 얻었다. 본 연구의 결과를 이용하여 갑상샘 질환의 진단에 있어 육안 판독에 따른 오류를 감소시키고, 미만성 갑상샘 질환 진단의 2차적인 수단으로 활용 가능할 것으로 기대된다.